• Title/Summary/Keyword: Luminance Level

Search Result 129, Processing Time 0.022 seconds

Light Pollution of Outdoor Lighting in Coastal Area - Focused on Busan City - (해안가 야간경관조명의 빛공해 평가 - 부산시를 중심으로 -)

  • Kong, Hyo-Joo;Kim, Jeong-Tai
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.6
    • /
    • pp.18-26
    • /
    • 2010
  • Outdoor lighting has become a necessary essential part of society for safety and comfortable space. However, inappropriate outdoor lighting leads to energy waste and poor landscape. Outdoor lighting is a very important social element, which enables us to conduct various activities at night in a safe, efficient and comfort way. River Thames in UK, Venice in Italy and Sydney in Australia is a good example of the coastal area. This paper aims to evaluate the light pollution of outdoor lighting in coastal area in Busan city. The Radiant Imaging ProMetric-1400 was used to measure the luminance of Gwangalli Beach, Marine City and Haeundae Beach. Compare to the CIE recommendation level the luminance of the all outdoor lighting were about 2~20 times higher. Outdoor lighting of the building facade luminance level and color should be particularly limited.

Chromatic adaptation model for the variations of the luminance of the same chromaticity illuminants (동일 색도 광원의 휘도 변화에 따른 색 순응 모델)

  • Kim Eun-Su;Jang Soo-Wook;Lee Sung-Hak;Sohng Kyu-lk
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.42 no.4 s.304
    • /
    • pp.31-38
    • /
    • 2005
  • In this paper, we propose the chromatic adaptation models (CAM) for the variations of the luminance levels. A chromatic adaptation model, CAM$\Delta$Y , is proposed according to the change of luminance level under the same illuminants. The proposed model is obtained by the transform the test colors of the high luminance into the corresponding colors of the low luminance. In the proposed model, the optimal coefficients are obtained from the corresponding colors data of the Breneman's experiments. In the experimental results, we confined that the chromaticity errors, $\Delta$u'v', between the predicted colors by the proposed model and the corresponding colors of the Breneman's experiments are 0.004 in u'v' chromaticity coordinates. The prediction performance of the proposed model is excellent because this error is the threshold value that two adjacent color patches can be distinguished. Additionally, we also propose equal-whiteness CCT curves (EWCs) by CAM$\Delta$Y according to the luminance levels of the surround viewing conditions. And the proposed EWCs can be used as the theoretical standard which determines the reference white of the color display devices.

The Effect of Background Grey Levels on the Visual Perception of Displayed Image on CRT Monitor (CRT 모니터의 배경(背景) 계조도(階調度)가 영상의 시각인식(視覺認識)에 미치는 영향)

  • Kim, Jong-Hyo;Park, Kwang-Suk;Min, Byoung-Goo;Lee, Choong-Woong
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1991 no.05
    • /
    • pp.18-21
    • /
    • 1991
  • In this paper, the effect of background grey levels on the visual perception of target image displayed on CRT monitor has been investigated. The purpose of this study is to investigate the efficacy of CRT monitor as a display medium of image information especially in medical imaging field. Three sets of experiments have been performed in this study; the first was to measure the luminance response of CRT monitor and to find the best fitting equation, and the second was the psychophysical experiment measuring the threshold grey level difference between the target image and the background required for visual discrimination for various background grey levels, and the third was to develop a visual model that is predictable of the threshold grey level difference measured in the psychophysical experiment. The result of psycophysical experiment shows that the visual perception performance is significantly degraded in the range of grey levels lower than 50, which is turned out due to the low luminance change of CRT monitor in this range while human eye has been adapted to relatively bright ambient illumination.

  • PDF

Solution-Processed Quantum-Dots Light-Emitting Diodes with PVK/PANI:PSS/PEDOT:PSS Hole Transport Layers

  • Park, Young Ran;Shin, Koo;Hong, Young Joon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.146-146
    • /
    • 2015
  • We report the enhanced performance of poly(N-vinylcarbozole) (PVK)/poly(3,4-ethylenedioxythiophene) polystyrene sulfonate (PEDOT:PSS)-based quantum-dot light-emitting diodes by inserting the polyaniline:poly (p-styrenesulfonic acid) (PANI:PSS) interlayer. The QD-LED with PANI:PSS interlayer exhibited a higher luminance and luminous current efficiency than that without PANI:PSS. Ultraviolet photoelectron spectroscopy results exhibited different electronic energy alignments of QD-LEDs with/without the PANI:PSS interlayer. By inserting the PANI:PSS interlayer, the hole-injection barrier at the QD layer/PVK interface was reduced from 1.45 to 1.23 eV via the energy level down-shift of the PVK layer. The reduced barrier height alleviated the interface carrier charging responsible for the deterioration of the current and luminance efficiency. This suggests that the insertion of PANI:PSS interlayer in QD-LEDs contributed to (i) increase the p-type conductivity and (ii) reduce the hole barrier height of QDs/PVK, which are critical factors leading to improve the efficiency of QD-LEDs.

  • PDF

The Effect of Background Grey Levels on the Visual Perception of Displayed Image on CRT Monitor (CRT 모니터의 배경계조도가 영상의 시각인식에 미치는 영향)

  • 김종효;박광석
    • Journal of Biomedical Engineering Research
    • /
    • v.14 no.1
    • /
    • pp.63-72
    • /
    • 1993
  • In this paper, the effect of background grey levels on the visual perception of target image displayed on CRT monitor has been investigated. The purpose of this study is to investigate the efficacy of CRT monitor as a display medium of image Information especially in medical imaging field. Tllree sets of experiments have been performed in this study : the first was to measure the luminance response of CRT monitor and to find the best fitting equation, and the second was the psychophysical experiment measuring the threshold grey level differences between the target image and the background required for visual discrimination (or various background grey levels, and the third was to develop a visual model that is predictable of the threshold grey level difference measured in the psychophysical experiment. The result of psycophysical experiment shows that the visual perception performance is significantly degraded in the range of grey levels lower than 50, which is turned out due to she low luminance change of CRT monitor in this range while human eye has been adapted lo relatively bright ambient illumination. And it Is also shown in the simulation study using the developed visual model that the dominant factor degrading the visual performance is the reflected light from the monitor surface by ambient light in general illumination condition.

  • PDF

A Study of the Daylighting Performance in Obstructed Office Building in Urban Area (오피스 건물에서 인접건물이 자연채광 성능에 미치는 영향)

  • Park, Woong-Kyu;Ki, Hyun-Joo;Jeong, Chan-Woul;Song, Doo-Sam
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.5
    • /
    • pp.101-108
    • /
    • 2014
  • The performance of the daylighting in buildings depends on building site and shape. As an energy saving design strategy, daylighting is a key issue in green building design. In this paper, the influence of the adjacent or obstructed building on daylighting performance of the office building in urban area was analyzed. A typical office building about 20 storeys with obstructed buildings has been modeled and simulated using Radiance. The parametric simulations have been performed to analyze the influence of the daylighting performance (illuminance, luminance) of the analyzed office. The results show that the possibility of the glare was decreased when the obstructed building is located in south, also the illuminance level was significantly decreased. When the obstructed building is located in north, the changes of the illuminance level and luminance possibility were somewhat small compared to the unobstructed condition. The daylighting performance of the analyzed building was most affected by the obstructed building in winter season.

Design and Installations of Road Lighting for Arterial Roads to Provide the Optimal Values of Light Technical Parameters (야간의 도로조명 상황에서 최적의 도로조명기준을 나타낼 수 있는 가로등의 설계와 배치에 관한 연구)

  • 김기혁
    • Journal of Korean Society of Transportation
    • /
    • v.9 no.2
    • /
    • pp.41-56
    • /
    • 1991
  • The aim of this research is designing road lighting installations(arrangement, mounting height spacing and overhang) which produce a certain level and distribution of luminance together with minimal glare. These can be varied over a limited range for a given luminance and road surface to achieve the required installation performance. In Korea there are no code of practice which lays down recommended performance criteria (Lavg, Uo, Ul, G, TI) with practical design guidance on how to achieve them. In case study design rules and current installation of road lighting in daegu city are analysed. The core of research are suggesting a new performance criteria and providing a set of table giving the maximum lognitudinal spacing between successive luminaires. The result of this research prescribes the combination of height and spacing for various road widths and arrangements which will achieve a specified minimum performance on straigt roads for particular luminaire and a particular road surf-ace.

  • PDF

Electro-luminescence Characteristics of Nano-Structural Thin Film (나노구조 박막의 EL 특성)

  • Choi, Yong-Sung;Cho, Jang-Hoon;Song, Jin-Won;Lee, Kyung-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.274-275
    • /
    • 2006
  • A new thin film materials can be built up at the molecular level, and the relationship between these artificial structures and the properties of materials can be explored. In this paper, in order to confirm the application possibility to the molecular electronic device of the organic materials, we have investigated electro-luminescent (EL) characteristics of organic EL device using $Alq_3$, PBD as emitting material. Current and luminance can be seen that express a similar relativity in voltage and could know that luminance is expressing current relativity.

  • PDF

A Perceived Contrast Compensation Method Adaptive to Surround Luminance Variation for Mobile Phones

  • Yang, Cheng;Zhang, Jianqi;Zhao, Xiaoming
    • Journal of the Optical Society of Korea
    • /
    • v.18 no.6
    • /
    • pp.809-817
    • /
    • 2014
  • The loss in contrast-discrimination ability of the human visual system under high ambient illumination level can cause image quality degradation in mobile phones. In this paper, we propose a perceived contrast compensation method by processing the original displayed image. With consideration that the perceived contrast significantly varies across the image, this method extracts the local band contrast from the original image; it then compensates these contrast components to counteract the perceived contrast degradation. Experimental results demonstrate that this method can maintain most contrast details even in high ambient illumination levels.

Characteristics of CaS:Eu,S electroluminescent devices (CaS:Eu,S 전계발광소자의 특성)

  • 조제철;유용택
    • Electrical & Electronic Materials
    • /
    • v.8 no.6
    • /
    • pp.752-758
    • /
    • 1995
  • Red emitting CaS:Eu,S electroluminescent(EL) device prepared at 550.deg. C by an electron-beam evaporation technique, demonstrated luminance of 175cd/m$\^$2/ and efficiency of 0.311m/W with 3kHz drive. Luminance was increased with the increase of applied voltage and frequency. From the results of the PL spectrum and the EL spectrum, the CaS:Eu, S device showed emission peak near 640nm resulted from the transition of EU$\^$2+/ 4f$\^$6/5d.rarw.4f$\^$7/. The capacitance of the phosphor layer from the Sawyer-Tower circuit was 10.5nF/cm$\^$2/.

  • PDF