• Title/Summary/Keyword: Luminance Characteristics

Search Result 545, Processing Time 0.026 seconds

Moving Picture Compression using Frame Classification by Luminance Characteristics (명암특성에 따른 프레임 분류를 이용한 동영상 압축기법)

  • Kim, Sang-Hyun
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.4
    • /
    • pp.51-56
    • /
    • 2011
  • This paper proposes an efficient moving picture compression for video sequences with luminance variations. In the proposed algorithm, the luminance variation parameters are estimated and local motions are compensated. To detect the frame required luminance compensation, we employ the frame classification based on the cross entropy between histograms of two successive frames, which can reduce the computational redundancy. Simulation results show that the proposed method yields a higher peak signal to noise ratio (PSNR) than that of the conventional methods, with a low computational load, when the video scene contains large luminance variations.

Performance Analysis of Laboratory and Field Luminance for Phosphorescent Line Marking and Preliminary Study of Luminance Analysis Using Digital Images (축광노면표시의 실내 및 현장 휘도 성능분석과 디지털이미지를 이용한 휘도분석 사전연구)

  • Kim, Sang Tae;Lee, Yong Mun;Kim, Heung Rae;Choi, Kee Choo
    • International Journal of Highway Engineering
    • /
    • v.18 no.6
    • /
    • pp.145-152
    • /
    • 2016
  • OBJECTIVES : Visibility at night can be improved by using retroreflection for short distances and phosphorescent line markings for long distances. In this study, we analyzed the characteristics of the phosphorescent line marking through a laboratory luminance test. Field performance analysis was performed through tests conducted on the road. We also examined the luminance measurement methods using the digital image obtained during the phosphorescent visibility evaluation. METHODS : In this study, the laboratory luminance test of the phosphorescent line marking was conducted using seven specimens to characterize the luminance changes according to the type of the glass beads, the thickness of the phosphorescent line marking, and the brightness and irradiation time of the light source. Phosphorescent and general line markings were made at 150 m to investigate the field luminance performance. A preliminary review of the luminance measurement methods was made using a digital image from a digital single-lens reflex (DSLR) camera. The measured luminance ratio of the general and the phosphorescent line markings was compared with the calculated luminance ratio using luminance analysis. RESULTS : Through the laboratory luminance test, it was seen that the change in luminance, which corresponds to the brightness of the light source, appears large but the influence of the thickness and irradiation time is low. The field performance test of the phosphorescent line marking conducted on the road involved measuring the luminance on the day the marking was made and 7 days after the marking was made. The luminance was found to be $190mcd/m^2$ at 30 min after sunset and approximately $10-12mcd/m^2$ 4h after sunset. The results of the luminance test were captured using a digital image for each time group. The luminance ratio of the phosphorescent line marking, when compared to that of the general line marking, showed a similar trend within a 13% maximum error. Additionally, when this luminance ratio is compared to the direct field measurement, it could be confirmed that the luminance ratio, as captured in the digital image, showed a similar tendency. CONCLUSIONS : 1) The change in luminance corresponding to the brightness of the light source is significant in comparison with that corresponding to the thickness and the irradiation time. In addition, the results of the field test for the phosphorescent line marking satisfied the phosphorescent fire protection standard. 2) We examined the validity of the luminance measurement method using a digital image and we concluded that the change in the luminance ratio shows a similar tendency in both the cases. The results can form the basis for luminance measurement methodology for the construction and maintenance of phosphorescent line markings.

Effect of Address Discharge Characteristics by Selective Reset Method in AC Plasma Display Panel (교류형 플라즈마 디스플레이에서 선택적 초기화 방법에 의한 기입 방전 특성의 영향)

  • Cho, Byung-Gwon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.12
    • /
    • pp.1004-1008
    • /
    • 2012
  • The effect of address discharge characteristics by selective reset method is investigated to prevent the weakness of address discharge in the middle of a TV-field without increase of the black luminance. To reduce black luminance in AC PDP usually, the first subfield during one TV frame adopted the conventional rising ramp-reset waveform, whereas the other subfields adopted the subsidiary reset waveform without rising ramp type. As the wall charge for the address discharge was accumulated by only the rising ramp waveform during the first reset period, the wall charge on three electrodes was disappeared as time passed and the address discharge would be weakened in the rear subfields. To prevent a reduction of the address discharge characteristics without decrease the black luminance, the modified rising ramp reset waveform was adopted only in the sixth subfield. As a result, a modified driving method could improve the address discharge characteristics compared with selective reset driving scheme with almost the same black luminance.

Determination of Optimal Mixing Ratio of Phosphorescent Pigment to Develop Phosphorescent Paint for Road Line Marking (도로의 축광차선 도료 개발을 위한 축광안료 최적 배합비 산정에 관한 연구)

  • Lee, Yong Mun;Kim, Sang Tae;Kim, Heung Rae
    • International Journal of Highway Engineering
    • /
    • v.17 no.5
    • /
    • pp.67-73
    • /
    • 2015
  • PURPOSES : This study was conducted to derive the optimum mixing ratio of phosphorescent pigment for the development of phosphorescent line marking. METHODS: In this study, we utilized a literature review and case study methodology, to describe the domestic and foreign state of practice for the production and mixing of phosphorescent pigment for use in line marking. The optimal mixing ratio was derived by comparing the reduction in luminance over time for the various phosphorescent pigment mixing ratios identified in the literature. In addition, performance and construction characteristics were analyzed using field testing techniques. RESULTS : The results were as follows: 1) the results of the luminance performance standards tests showed that all of the phosphorescence test specimens satisfied the phosphorescent fire protection standard. As the phosphorescent pigment mixing ratio increased, the luminance value increased, 2) the luminance reduction rate was minimum at the mixing ratio of 50%. However, when compared to a mixing ratio 40%, a small difference was recorded, the luminance reduction rate from the mixing ratio of 40% is judged as being converged. Therefore, in view of the economic efficiency, it was determined that the optimal mixing ratio was 40%, 3) as a result of construction on the field, a mixing ratio of 40% was found to have a higher luminance value than the general line marking for up to three hours after sunset, 4) it was found that the phosphorescent line markings without glass beads spraying had a higher luminance value than the phosphorescent line markings with glass beads spraying. CONCLUSIONS : Through the results of the basic experiments of the line markings obtained by blending a phosphorescent pigment, the results could be applied to play an important role in the development of phosphorescent line marking paint technology and in establishing application planning for on-site construction characteristics.

The effect of Gas Mixture Ratio on Discharge Characteristics of an AC PDP Cell

  • Lee, Hae-June;Lee, D.K.;Choi, J.H.;Cho, Y.S.;Park, H.D.;Lee, H.J.;Park, C.H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07a
    • /
    • pp.171-174
    • /
    • 2005
  • Experimental measurements are reported and compared with the results of a two-dimensional fluid simulation for the investigation of the discharge characteristics regarding the change of the mixture ratio of Ne-Xe-He noble gases. The increase of Xe contents results in the increases of luminance and luminous efficiency while it also results in the increase of the breakdown voltage and the discharge time lag. The addition of He gas increases the brightness and the luminance efficiency. When Xe partial pressure is low, the luminance efficiency increases with the amount of He at the same total pressure. When Xe partial pressure is high, however, the luminance efficiency has a maximum value when the partial pressure of He is about 10% of the total pressure for a standard AC PDP cell with Xe fraction of $10{\sim}30%$.

  • PDF

A Study on the Sustain Discharge Characteristics as the Voltage of Address Electrode of AC-Plasma Display (교류형 플라즈마 디스플레이의 Address 전극의 전압에 따른 Sustain 방전 특성 연구)

  • Shin, Jae-Hwa;Choi, Hoon-Young;Lee, Seok-Hyun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.52 no.2
    • /
    • pp.61-67
    • /
    • 2003
  • To improve the luminance and luminous efficiency of a surface-discharge alternate current plasma display panel, we analyzed the sustain discharge characteristics as the voltage of the address electrode In the study. As the results, when the address voltage is a half of the sustain voltage in the sustain period, the luminance and luminance efficiency are the highest. The luminance efficiency increased about 16.2%~20.8% compared with the conventional type.

Relationships Between Impurity Gas and Luminance/Discharge Characteristics of AC PDP

  • Heo, Jeong-Eun;Lee, Sung-Hyun;Kim, Young-Kee;Shin, Jooh-Hong;Yoo, Choong-Hee;Park, Chung-Hoo
    • Journal of Information Display
    • /
    • v.2 no.4
    • /
    • pp.29-33
    • /
    • 2001
  • The luminance and discharge characteristics of an AC PDP may be significantly affected by a small amount of impurity gas in working gas. Impurity gases such as $O_2$, O , C and $H_2$ can be mixed in the manufacturing and lor discharge processes. In this paper, a small amount of impurity gas in AC PDP are introduced intertimally and the relationship between the amount of impurity gas and the luminance/discharge characteristics are investigated. The luminous efficiency decreased seriously with the increase in the partial pressure of impurity gases, especially in $H_2$, $O_2$ and $CO_2$, Under the condition of the impurity gas ratio of 2x $10^{-3}$ for Ar, $N_2$, $H_2$, $CO_2$ and $O_2$, the luminous efficiency decreased to about 8%, 8%, 32%, 36% and 50%, respectively.

  • PDF

Model of Organic Light Emitting Device Emission Characteristics with Alternating Current Driving Method (교류 구동 방법에 의한 유기전계발광소자 발광 특성의 모델)

  • Seo, Jung Hyun;Ju, Sung Hoo
    • Korean Journal of Materials Research
    • /
    • v.31 no.10
    • /
    • pp.586-591
    • /
    • 2021
  • This paper proposes a mathematical model that can calculate the luminescence characteristics driven by alternating current (AC) power using the current-voltage-luminance (I-V-L) properties of organic light emitting devices (OLED) driven by direct current power. Fluorescent OLEDs are manufactured to verify the model, and I-V-L characteristics driven by DC and AC are measured. The current efficiency of DC driven OLED can be divided into three sections. Region 1 is a section where the recombination efficiency increases as the carrier reaches the emission layer in proportion to the increase of the DC voltage. Region 2 is a section in which the maximum luminous efficiency is stably maintained. Region 3 is a section where the luminous efficiency decreases due to excess carriers. Therefore, the fitting equation is derived by dividing the current density and luminance of the DC driven OLED into three regions, and the current density and luminance of the AC driven OLED are calculated from the fitting equation. As a result, the measured and calculated values of the AC driving I-V-L characteristics show deviations of 4.7% for current density, 2.9 % for luminance, and 1.9 % for luminous efficiency.

Study on Analysis of Characteristics of Illuminance and Luminance Distribution of LED Luminaires (LED 조명기구의 조도.휘도분포 특성 분석에 관한 연구)

  • Lee, Jin-Sook;Kim, Won-Do;Kim, Byoung-Soo;Han, Won-Tak
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.9
    • /
    • pp.1-7
    • /
    • 2008
  • This study is intended to compare physical properties of fluorescent luminaires with ones of LED luminaires so as to analyze fundamental characteristics of LED luminaires. For this, a comparative analysis of uniformity ratio of illuminance and luminance distribution of these two luminaires was made, and materials for applying LED luminaires to interior construction space were prepared. This study was carried out in four stages. First, a theoretical review on LED illumination light source was made compared with the existing luminaires. Second, a mock-up to control experimental variables to meet the objective of this study was manufactured. Third uniformity ratio of illuminance and luminance distribution of each luminaire were measured by using the mock-up. Fourth, a comparative analysis of uniformity ratio of illuminance and characteristics of luminance distribution of the existing fluorescent luminaires and LED ones was made. As a result of the study, the uniformity ratio of illuminance of LED luminaires, 0.559, was higher than one of the existing fluorescent luminaires, 0.522. Namely, it was shown that illuminance distribution of LED luminaires was uniform and global diffuse was good. As a result of measuring luminance distribution, it was found that luminance distribution of LED luminaires was more uniform than one of the existing fluorescent luminaires. The maximum luminance of fluorescent luminaires and LED luminaires over the wall was $180.6[cd/m^2]$ and $155.26[cd/m^2]$ respectively. Namely, the maximum luminance of fluorescent luminaires was higher than one of LED luminaires. The average luminance of fluorescent luminaires and LED luminaires was $44.32[cd/m^2]$ and $58.65[cd/m^2]$. Like this, the average luminance of LED luminaires was higher than one of fluorescent luminaires. Considering these results, it's thought that LED luminaires can give a person in the room a more comfortable working environment than fluorescent luminaires.

The Effect of Working Gas Xex+Ne1-x on the Electro-optical Characteristics of AC PDP (AC PDP의 전기광학적 특성에 미치는 동작 Gas Xex+Ne1-x의 영향)

  • Park, Chung-Hoo;Yoo, Su-Bok;Lee, Don-Kyu;Lee, Hae-June;Lee, Ho-Jun;Kim, Jae-Sung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.1
    • /
    • pp.142-146
    • /
    • 2007
  • Nowadays, itis inevitable trend to use high Xe gas contents for increase luminous efficiency and luminance in plasma display panel. However, the increase of Xe gas contents causes the driving voltage, although the brightness is increase. In this paper, we study the characteristics of electro optical according to Xe gas contents and gas pressure. Electro-optical characteristics were investigated by the discharge voltage, luminance and luminous efficacy measurements, respectively. With some increasing Xe gas contents and pressure, the electro-optical properties increased. However, the characteristics of electro-optical begin to be saturated, when too high increased Xe gas contents and pressure.