• 제목/요약/키워드: Luminance Analysis

검색결과 195건 처리시간 0.027초

HDR이미지를 이용한 공동주택 외부조명의 휘도 분석 (Luminance Analysis of the Apartment Exterior Lighting using HDR Images)

  • 홍승대;신은주
    • 한국디지털건축인테리어학회논문집
    • /
    • 제12권2호
    • /
    • pp.33-38
    • /
    • 2012
  • The purpose of luminance measurement in lighting design of urban scale is to prevent light trespass and light pollution, caused by over-bright. Specially, the illumination of road, tunnel and sports complex as urban infrastructure is measured by international standard for illuminance and luminance. It has been used the spot luminance meter and the image photometer to define the characteristics of qualitative and quantitative in exterior lighting. This study introduced the concept of HDR Image, procedure of HDR Image creation and analysis. Applications of HDR Image, particularly within the apartment building exterior lighting design analysis, have been demonstrated. The procedure proposed in this study is a affordable method that is useful for the assessment of luminance distribution in the scene with electric light. It also provides a measurement capability with the high resolution luminance data within a large field of view efficiently and quickly, which is not possible to achieve with a luminance meter.

축광노면표시의 실내 및 현장 휘도 성능분석과 디지털이미지를 이용한 휘도분석 사전연구 (Performance Analysis of Laboratory and Field Luminance for Phosphorescent Line Marking and Preliminary Study of Luminance Analysis Using Digital Images)

  • 김상태;이용문;김흥래;최기주
    • 한국도로학회논문집
    • /
    • 제18권6호
    • /
    • pp.145-152
    • /
    • 2016
  • OBJECTIVES : Visibility at night can be improved by using retroreflection for short distances and phosphorescent line markings for long distances. In this study, we analyzed the characteristics of the phosphorescent line marking through a laboratory luminance test. Field performance analysis was performed through tests conducted on the road. We also examined the luminance measurement methods using the digital image obtained during the phosphorescent visibility evaluation. METHODS : In this study, the laboratory luminance test of the phosphorescent line marking was conducted using seven specimens to characterize the luminance changes according to the type of the glass beads, the thickness of the phosphorescent line marking, and the brightness and irradiation time of the light source. Phosphorescent and general line markings were made at 150 m to investigate the field luminance performance. A preliminary review of the luminance measurement methods was made using a digital image from a digital single-lens reflex (DSLR) camera. The measured luminance ratio of the general and the phosphorescent line markings was compared with the calculated luminance ratio using luminance analysis. RESULTS : Through the laboratory luminance test, it was seen that the change in luminance, which corresponds to the brightness of the light source, appears large but the influence of the thickness and irradiation time is low. The field performance test of the phosphorescent line marking conducted on the road involved measuring the luminance on the day the marking was made and 7 days after the marking was made. The luminance was found to be $190mcd/m^2$ at 30 min after sunset and approximately $10-12mcd/m^2$ 4h after sunset. The results of the luminance test were captured using a digital image for each time group. The luminance ratio of the phosphorescent line marking, when compared to that of the general line marking, showed a similar trend within a 13% maximum error. Additionally, when this luminance ratio is compared to the direct field measurement, it could be confirmed that the luminance ratio, as captured in the digital image, showed a similar tendency. CONCLUSIONS : 1) The change in luminance corresponding to the brightness of the light source is significant in comparison with that corresponding to the thickness and the irradiation time. In addition, the results of the field test for the phosphorescent line marking satisfied the phosphorescent fire protection standard. 2) We examined the validity of the luminance measurement method using a digital image and we concluded that the change in the luminance ratio shows a similar tendency in both the cases. The results can form the basis for luminance measurement methodology for the construction and maintenance of phosphorescent line markings.

Empirical Equations for the Analysis of the Time Dependence of the Luminance Properties of LCD Panels and Backlights for TV Applications

  • Ryu, Jin-Sun;Kim, Su-Jin;Park, Seung-Mi;Ko, Jea-Hyeon
    • Journal of Information Display
    • /
    • 제11권2호
    • /
    • pp.39-44
    • /
    • 2010
  • The time dependences of the luminance properties of 55-inch CCFL and LED backlights and 32-inch FFL backlights with LCD panels were investigated during the warm-up time from the cold start. The long-term luminance maintenance curve of a standard CCFL was examined in a time window up to 5000 hours. These two time dependences are important characteristics from the viewpoint of initial picture quality and lifetime reliability, respectively. Empirical equations were suggested for the analysis of the time dependence of these luminance data. These approaches are expected to be helpful in predicting the luminance properties of backlights based on the luminance data obtained in a limited time window.

도로터널의 경계부 순응휘도 측정 및 분석 (Measurement and Analysis of Adaptation Luminance in the Threshold Zone of the Road Tunnel)

  • 한종성;이민욱;김훈
    • 조명전기설비학회논문지
    • /
    • 제26권1호
    • /
    • pp.1-7
    • /
    • 2012
  • As the standard lighting required in the threshold zone of a road tunnel is determined by the enough contrast. Lighting design, therefore, must be determined by the calculation method of threshold luminance based on the adaptation luminance of the driver approaching the tunnel. The veiling luminance and the luminance in the access zone were measured at different time and in different weather using the veiling luminance method, a kind of perceived contrast methods, and the L20 method when the range of vision was 20 degrees. On the basis of the measured data each threshold luminance was calculated and its results were analyzed.

휘도맵의 작성을 위한 HDRI 생성 도구의 신뢰도에 관한 연구 (A Study of HDR Software Reliability for the Luminance Map Creation)

  • 홍승대
    • 한국디지털건축인테리어학회논문집
    • /
    • 제12권3호
    • /
    • pp.81-89
    • /
    • 2012
  • Luminance is the most important quantity in lighting design and illuminating engineering. There are three methods for measuring luminance; using a conventional luminance meter, through the illuminance measurement and subsequent calculations and using digital imaging photometer. Recently, HDRI(High Dynamic Range Imaging) technique introduces a new method of capturing luminance values in a lighting environment. The radiance maps from HDRI are commonly used as visual environment maps for lighting analysis applications. For the HDRI, HDR software is needed to create HDR image. Currently, there is number of HDR software available. The purpose of this paper is to investigate whether a luminance map can be accurately captured by the various types of HDR software which include HDR Shop and Photoshop. To accomplish this goal a set of experiments was conducted. In order to assess the luminance values of the HDR image from HDR software, the values had to be compared to the ones obtained with conventional methods of luminance measurement.

휘도맵의 작성을 위한 HDRI 획득에 있어서 EV의 범위 (An EV Range in HDRI Acquisition as a Luminance Map Creation)

  • 홍승대
    • 조명전기설비학회논문지
    • /
    • 제24권10호
    • /
    • pp.5-12
    • /
    • 2010
  • The purpose of this study is to present the EV range in HDRI acquisition process to create luminance map. The proposed method in this study is to capture the scene at EV ${\pm}0$ that is the longest exposure points and reference point in the scene. With this reference point, sets of 25 LDRI test case were taken manually at ${\pm}2$ EV using the aperture-priority manual mode. The 25 HDRIs were created using Adobe Photoshop. The HDRIs were then imported Radiance lighting simulation program to be analyzed into falsecolor. The analysis results of the 25 HDRIs test case are 50[%] of the all tested case have a margin of error of 10[%]. In case of f/5.6, the luminance map generated with HDRI were similar to the spot luminance meter. As a result, the EV range to reduce error of luminance map generated with HDRI is EV $+2{\sim}{\pm}0{\sim}-10$.

측정 위치를 고려한 영상기반 휘도측정시스템에 관한 연구 (A Study on the Image-Based Luminance Measurement System Using the Measuring Position)

  • 선은혜;김용태
    • 한국지능시스템학회논문지
    • /
    • 제24권4호
    • /
    • pp.424-429
    • /
    • 2014
  • 본 논문에서는 발광광고물의 휘도를 측정하는 영상기반 휘도측정시스템을 제안한다. 제안하는 휘도측정시스템은 DSLR 카메라의 영상을 이용하여 점휘도계의 효율성과 면휘도계의 휴대성 및 경제성의 단점을 보완하며, 대상의 전체적인 휘도를 측정하는 시스템으로 영상을 입력받아 휘도분석 알고리즘을 통해 실시간으로 휘도값이 출력되도록 설계하였다. 측정 대상인 발광광고물은 설치 위치, 크기, 모양이 다양하며, 발광광고물의 휘도는 측정 거리, 각도, 색 등 다양한 조건에 따라 측정값이 달라진다. 따라서 정확한 휘도를 측정하기 위하여 측정대상물과의 거리에 따른 휘도값의 변화를 측정하였고, 측정 거리가 증가하면 휘도값이 변화하는 것을 고찰하였다. 실험을 통하여 측정 위치와 휘도값의 연관성을 수식으로 나타내었고, 제안한 방법을 평가하기 위해 점휘도계를 이용한 측정값과 비교 실험을 진행하였다.

CCFL Backlight characterization using luminance meter and image analysis.

  • Gibour, Veronique;Boher, Pierre;Leroux, Thierry
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2004년도 Asia Display / IMID 04
    • /
    • pp.791-794
    • /
    • 2004
  • In this article, we present a method to measure precisely the performances of direct-lit CCFL backlights using a luminance meter and dedicated image analysis software. The array of CCFL tubes alone can be measured directly and the luminance of each tube can be extracted along its main dimension. So, comparison of the different tubes on the same backlight can be made easily and the performances in terms of backlight uniformity improved. The influence of the diffuser sheet can be probed in the same way and the homogeneity of the entire surface of the backlight can be automatically extracted and quantified.

  • PDF

DSLR를 이용한 야간경관 휘도 측정 기법에 관한 연구 (A Study on luminance Measurement Method of Lightscape using DSLR)

  • 이완수;정강화
    • 조명전기설비학회논문지
    • /
    • 제23권2호
    • /
    • pp.10-17
    • /
    • 2009
  • 야간경관에는 수많은 광원(光源)에 의해 다양한 휘도(Luminance)로 나타난다. 휘도를 측정하는데 있어 측정 범위가 한정되어 있다. 기존의 휘도계를 이용한 측정방식은 하나의 점을 통한 점(Point)측정방식이기 때문이다. 야간경관의 휘도를 쉽고 편리하게 정보를 얻고자 휘도 측정에 있어 DSLR 카메라를 이용하게 되었다. 현재 광학의 기술로 인해 디지털 카메라의 활용가치가 매우 크며 쉽게 이미지데이터를 얻을 수 있다. 이러한 디지털 이미지로부터 야간경관의 휘도 분석과 DSLR 카메라의 면(Scene) 측정방식을 통한 휘도 측정 기법에 대해 제안하고자 한다.

LED 조명기구의 조도.휘도분포 특성 분석에 관한 연구 (Study on Analysis of Characteristics of Illuminance and Luminance Distribution of LED Luminaires)

  • 이진숙;김원도;김병수;한원탁
    • 조명전기설비학회논문지
    • /
    • 제22권9호
    • /
    • pp.1-7
    • /
    • 2008
  • 본 연구의 목적은 형광등조명기구와 LED 조명기구와의 물리적 특성을 비교하여 LED조명기구의 기본적인 특성을 분석하는데 있다. 여기서 두가지 조명기구의 균제도 및 휘도분포 측면에서 비교 분석하여 LED조명기구를 건축실내공간에 적용하기 위한 자료를 작성하였다. 연구는 4단계로 나누어 진행하였다. 첫째, 기존의 조명기구와 비교한 LED조명광원의 이론적인 검토를 하였다. 둘째, 연구의 목적에 부합되도록 실험변인을 조절할 수 있는 실물대모형(Mock-up)을 제작하였다. 셋째, 설치된 실물대의형을 이용하여 조명기구별 균제도 휘도분포를 측정하였다. 최종적으로, 기존의 형광등기구와 LED조명기구간의 균제도 휘도분포 특성을 비교분석하였다. 연구결과 LED조명기구가 균제도 0.569로 기존 형광등조명기구의 균제도 0.522보다 높아 균일한 조도분포 특성을 보이고 전반확산이 양호한 것으로 나타났다. 또한 휘도분포를 측정한 결과 LED조명기구가 보다 균일한 휘도분포 특성을 보였고, 벽면의 휘도분포는 형광등조명기구에 의한 최대휘도가 $180.6[cd/m^2]$, LED조명기구는 $155.26[cd/m^2]$로 형광등이 높고, 평균휘도는 형광등조명기구가 $44.32[cd/m^2]$, LED조명기구가 $58.65[cd/m^2]$로 LED조명기구가 높게 나타났다. 이상의 결과로 볼 때, LED조명기구가 형광등조명기구보다 재실자에게 보다 쾌적한 작업환경을 구성할 수 있는 조명이라 판단된다.