• Title/Summary/Keyword: Luminaire Control

Search Result 22, Processing Time 0.015 seconds

Building Energy Savings due to Incorporated Daylight-Glazing Systems (통합 채광시스템의 건물 냉난방 에너지 성능평가)

  • Kim, Jeong-Tai;Ahn, Hyun-Tae;Kim, Gon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.6
    • /
    • pp.1-8
    • /
    • 2005
  • The quantity of light available for a space can be translated in term of the amount of energy savings through a process of a building energy simulation. To get significant energy savings in general illumination, the electric lighting system must be incorporated with a daylight - activated dimmer control. A prototype configuration of an once interior has been established and the integration between the building envelope and lighting and HVAC systems is evaluated based on computer modeling of a lighting control facility. First of all, an energy-efficient luminaire system is designed and the lighting analysis program, Lumen-Micro 2000 predicts the optimal layout of a conventional fluorescent lighting future to meet the designed lighting level and calculates unit power density, which translates the demanded met of electric lighting energy. A dimming control system integrated with the contribution of daylighting has been applied to the operating of the artificial lighting. Annual cooling load due to lighting and the projecting saving amount of cooling load due to daylighting under overcast diffuse sky m evaluated by computer software ENER-Win. In brief, the results from building energy simulation with measured daylight illumination levels and the performance of lighting control system indicate that daylighting can save over 70 percent of the required energy for general illumination in the perimeter zones through the year A 25[%] of electric energy for cooling and almost all off heating energy may be saved by dimming and turning off the luminaires in the perimeter zones.

Study on Sensitivity of Variables of the Experiment to Evaluate Discomfort Glare of Interior Artificial Illumination (건축실내 인공조명의 불쾌글레어 평가실험에 적용된 실험변수의 민감도 분석에 관한 연구)

  • Lee, Jin-Sook;Kim, Won-Do;Kim, Chang-Soon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.1
    • /
    • pp.24-32
    • /
    • 2008
  • The ultimate purpose of the study is to develop a discomfort glare forecasting formula that can be practically used in Korea in order to effectively forecast discomfort glare considering the optical characteristics of the Koreans. The study was to examine the relations between discomfort glare and the variables such as luminance, background luminance, solid angle, luminous area and louver. To this end, experiments were conducted in a mock-up office that emulates the lighting environment of an ordinary office. The study was conducted by four steps as follow. First, previous studies on discomfort glare rating to define and rate discomfort glare were analyzed and modified to be applied to the experiments of this study. Second, experiment variables, variable scope, evaluation objects and evaluation points were determined after review on existing discomfort glare evaluation experimental formulas. Third, experiments were conducted in a mock-up office to be able to control variables. Finally, sensitivity of experiment variables were analyzed through examination of the relation between discomfort glare and the variables such as luminance, solid angle, louver, luminous area and subject's position. The result showed that the most influential variables on discomfort glare of an artificial light source is luminance and louver, luminous area and subject's position(solid angle) followed.