A study on the safety LED lamp using internal control gear as the alternative type of fluorescent lamp (형광램프 대체 컨버터 내장형 LED램프의 안전성 확보방안)

  • Ko, Jae-jun;Kim, Chung-hyeok
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.3
    • /
    • pp.30-38
    • /
    • 2015
  • As products using LEDs are developed actively, also there has been large request for LED products that can replace traditional lamps like fluorescent lamps and metal halide lamps. But so far there is no proper standard that manufacturer can use and test it. As a result manufacturer can't develop retrofit LED lamps and sell it even they have technology. In this study, by analyzing control gear for fluorescent lamp that is currently used in market which is magnetic or electronic ballast, I'd like to develop proper test method by investigating compatibility between all-type control gear and LED retrofit products.

Analysis of Luminous Quantity Changes by the Dimming Control of the LED Lamp (조광제어에 의한 LED램프의 광특성 변화 분석)

  • Jang, In-Hyun;Kim, Yu-Sin;Choi, An-Seop
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.10
    • /
    • pp.13-20
    • /
    • 2010
  • Until now, dimmable fluorescent luminaires has been widely used for dimming systems, and LED is currently attracting attentions as a alternative lamp due to environmental problem issues. LED, one of eco-friendly high efficiency lamp, has advantage that dimming is easy than fluorescent luminaire. But there have been not enough research on technical development and application for LED dimming. Therefore, to analyze luminous quantity of dimmable LED, the illuminance, color temperature, luminance, and current were measured in the whole range of dimming. In the results of this study, the dimmable LED of various types showed a similar trend in the changed luminous quantity by dimming.

A Study on the Optical Characteristics of LED Lamp as Alternative Type of FPL Lamp (FPL형광램프 대체형 LED램프의 조도특성에 관한 연구)

  • Ko, Jae-jun;Kim, Chung-hyeok
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.10
    • /
    • pp.1-6
    • /
    • 2015
  • As lamps using LEDs are developed actively, also there have been large request for LED lamps that can replace traditional lamps like fluorescent lamps and metal halide lamps. But so far there are no proper standards that manufacturer can use and test their lamps. As a result of this, manufacturers are not only unable to develop LED lamps but also sell it even though they have technology. In this study, It is proposed that proper test method by investigating compatibility between all-type control gear and LED lamps by analyzing control gear for fluorescent lamp such as magnetic or electronic ballast that is currently used in the market.

A Study on Light Collector and Luminaire Design using Microstructured Film (미세 필름을 이용한 집광 및 조명장치 연구)

  • Jeong, Hak-Geun;Jung, Bong-Man;Han, Su-Bin;Lee, Euy-Jun
    • KIEAE Journal
    • /
    • v.2 no.1
    • /
    • pp.49-54
    • /
    • 2002
  • Solar daylighting system provides free and comfort lighting, but its cost has been key issue due to difficult design and control of the heavy light collecting system. One of the solutions for the heavy design issues would be using a light framed film such fresnel and prism lens. Prism light guide luminaires have for some time been used to distribute light when it is desirable to have remote light sources. These systems are helpful when it is desirable to have fewer light sources, and/or to position light sources in places where lamp maintenance is easier, or electrical hazard is reduced. This proposed prototype system consists of light collector, light transformer and light pipe.

Study on the Development of LED streetlight control system using GPS satellite communication and Arduino (GPS 위성통신과 아두이노를 이용한 에너지 절약형 LED 가로등 제어 시스템 개발에 관한 연구)

  • Lee, Wan-Bum
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.4
    • /
    • pp.632-637
    • /
    • 2016
  • A streetlight control system was developed using information technology and LED lights for efficient management and energy savings. The proposed system can control the power usage of an LED streetlight luminaire using GPS satellite communication and an Arduino with a built-in microprocessor. A control circuit was designed to control the current using GPS, a control unit, transistor, resistor, and constant-current supply circuit. The circuit was validated through experiments with normal operation. Using GPS, the control system extracts accurate time and location information according to the season, and it controls the current supplied to the LED streetlight according to the extracted time. Power consumption was reduced by more than 11%. The control system could reduce accidents caused by conventional lighting systems used to save energy, and it could improve the inefficient management of energy by preserving constant brightness of a streetlight at times and in areas that have less traffic.

Dimming Control of the LED Luminaire Emergency Exit Sign Operation using a Hybrid Super Capacitor of DC-DC Convertor (하이브리드 슈퍼커패시터 DC-DC 컨버터를 이용한 LED 비상 유도등 동작 디밍 제어)

  • Hwang, Lark-Hoon;Kim, Jin-Sun;Na, Yong-Ju
    • Journal of Advanced Navigation Technology
    • /
    • v.21 no.3
    • /
    • pp.220-229
    • /
    • 2017
  • In this paper, To take advantage a variety of DC power as the boost DC-DC converter design specifications through the inductor L and capacitor C through PSPICE to calculate the best estimate of the value. Boost DC-DC converter with a switch device using IRF840 and reverse recovery time Schottky diodes with excellent with constant current controller using D10SC6M and resistance can be configured to considering the Power LED Module was driven by the production. Converter's switching frequency is 50 kHz, the first Duty Rate was made to increase gradually depending on the value of the detection were, 10 % in the output voltage. As a result, the simulated Boost Power LED driver characteristics is in comparison with the design specifications, 5% or less as the error was approximated. Finally, when input 15 V were offered, a stable output 24 V were obtained. and Dimming Control through the adjustment of brightness and current consumption were possible.

Predicted Performance of the Integrated Artificial Lighting System in Relation to Daylight Levels (채광시스템과 인공조명설비의 통합기술 및 성능평가연구)

  • Kim, G.;Kim, J.T.
    • Journal of the Korean Solar Energy Society
    • /
    • v.22 no.3
    • /
    • pp.47-56
    • /
    • 2002
  • The office is an excellent candidate for implementing daylighting techniques because of the relatively high electric lighting power densities and long daytime use pattern. The quantity of light available for a space can be translated in term of the amount of energy savings through a process of a building energy simulation. To get significant energy savings in general illumination, the electric lighting system must be incorporated with a daylight - activated dimmer control. A prototype configuration of an office interior has been established and the integration between the building envelope and lighting and HVAC systems is evaluated based on computer modeling of a lighting control facility. First of all, an energy-efficient luminaire system is designed for both a totally open-plan office interior and a partitioned office. A lighting design and analysis program, Lumen-Micro 2000 predicts the optimal layout of a conventional fluorescent lighting fixture to meet the designed lighting level and calculates unit power density, which translates the demanded amount of electric lighting energy. A dimming control system integrated with the contribution of daylighting has been applied to the operating of the artificial lighting. Annual cooling load due to lighting and the projecting saving amount of cooling load due to daylighting under overcast diffuse sky are evaluated by a computer software, ENER-Win. In brief, the results from building energy simulation with measured daylight illumination levels and the performance of lighting control system indicate that daylighting can save over 70 percent of the required energy for general illumination in the perimeter zones through the year. A 25 % of electric energy for cooling may be saved by dimming and turning off the luminaires in the perimeter zones.

Study on Analysis of Characteristics of Illuminance and Luminance Distribution of LED Luminaires (LED 조명기구의 조도.휘도분포 특성 분석에 관한 연구)

  • Lee, Jin-Sook;Kim, Won-Do;Kim, Byoung-Soo;Han, Won-Tak
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.9
    • /
    • pp.1-7
    • /
    • 2008
  • This study is intended to compare physical properties of fluorescent luminaires with ones of LED luminaires so as to analyze fundamental characteristics of LED luminaires. For this, a comparative analysis of uniformity ratio of illuminance and luminance distribution of these two luminaires was made, and materials for applying LED luminaires to interior construction space were prepared. This study was carried out in four stages. First, a theoretical review on LED illumination light source was made compared with the existing luminaires. Second, a mock-up to control experimental variables to meet the objective of this study was manufactured. Third uniformity ratio of illuminance and luminance distribution of each luminaire were measured by using the mock-up. Fourth, a comparative analysis of uniformity ratio of illuminance and characteristics of luminance distribution of the existing fluorescent luminaires and LED ones was made. As a result of the study, the uniformity ratio of illuminance of LED luminaires, 0.559, was higher than one of the existing fluorescent luminaires, 0.522. Namely, it was shown that illuminance distribution of LED luminaires was uniform and global diffuse was good. As a result of measuring luminance distribution, it was found that luminance distribution of LED luminaires was more uniform than one of the existing fluorescent luminaires. The maximum luminance of fluorescent luminaires and LED luminaires over the wall was $180.6[cd/m^2]$ and $155.26[cd/m^2]$ respectively. Namely, the maximum luminance of fluorescent luminaires was higher than one of LED luminaires. The average luminance of fluorescent luminaires and LED luminaires was $44.32[cd/m^2]$ and $58.65[cd/m^2]$. Like this, the average luminance of LED luminaires was higher than one of fluorescent luminaires. Considering these results, it's thought that LED luminaires can give a person in the room a more comfortable working environment than fluorescent luminaires.

Analysis of Performance on Asymmetric LED Lens Design Using Three-Dimensional Free-Form Surface Expression (3차원 자유곡면식을 이용한 LED 비대칭 렌즈 설계 및 성능 비교 분석)

  • Lee, Chang Soo;Lee, Soo Young;Hyun, Dong Hoon
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.26 no.3
    • /
    • pp.328-336
    • /
    • 2017
  • The exit surface of a lens is designed using a three-dimensional free-form expression in order to easily modify a curved surface. This enables the design of numerical values and mathematical things using three-dimensional free-form expression, and enhances precision because it can be fine-tuned via numerical control. The standard of "Classification of Luminaire Light Distribution" for outdoor lighting fixtures by IESNA is adopted in order to examine the correlation between three-dimensional free-form surface expression and lighting performance. The variation of light distribution type and range is analyzed using the values of maximum light intensity and 50% light intensity. The actual tolerance occurs owing to parameters such as the thickness of the lens, the distance between LEDs, and the movement of the center of the incident surface; the effects of changes in these parameters on the performance are compared and analyzed.

A Research to Minimizing the Effect of Voltage Disturbances on Sensitive Electrical and Electronic Equipment (민감한 전기전자기기의 전압외란에 대한 영향 최소화 연구)

  • 윤갑구
    • Journal of the Korean Professional Engineers Association
    • /
    • v.19 no.2
    • /
    • pp.10-20
    • /
    • 1986
  • This paper describes a countermeasure of electric utilities and customer equipment in order to minimize an effect of sensitive electrical and electronic equipment on the voltage disturbances. After being studied, some schemes to solve were discovered. Firstly, in the electric utilities, the reduction of frequency and influence of voltage drop's time are not easy to realize because of the standpoint of effect and economy. Secondly, in the customer equipment, there are some equipment to minimize the voltage disturbances, Such as an UPSs, a noise suppressors and a power conditioners. One of them should be established on the computer control and automated systems, the electromagnetic switch of delay-release type should be adopted on the electromagnetic switch, the controlling circuit should be adopted on the variable speed motors which is being considered a countermeasure for a momentary under-voltage drops, the luminaire adhering a instantaneous restrike device should be adopted on the HID lamp. And also, the scheme of extending a setting time of relay on the undervoltage relay and the forming method of sequence which is automatic reclosing at this time of instantaneous suspension of an electric supply have been studied.

  • PDF