• Title/Summary/Keyword: Lower semi-continuous

Search Result 45, Processing Time 0.024 seconds

Characteristics of Visibility Impairment by Semi-Continuous Optical and Chemical Property Monitoring of Aerosols in Seoul (에어로졸의 광학 및 화학 특성 준실시간 모니터링을 통한 서울지역 시정 감쇄 분석)

  • Park, Jong-Sung;Park, Seung-Myung;Song, In-Ho;Shin, Hye-Jung;Hong, You-Deog
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.31 no.4
    • /
    • pp.319-329
    • /
    • 2015
  • The characteristics of aerosol light extinction were investigated by comparing measured and calculated extinction coefficient to understand the contribution of air pollutants on visibility impairment for data during 4 months (Jan~ April), 2014. The integrated nephelometer and aethalometer system were installed to measure the scattering and absorption coefficients of aerosol as well as BAM 1020, MARGA, semi-continuous OCEC analyzer, and online-XRF to calculate the extinction coefficient. The IMPROVE_2005 equation was used to determine the contributions of different chemical components on visibility impairment in $PM_{2.5}$ and $PM_{10}$ due to highest correlation with measured data. Sulfate, nitrate, and organic mass by carbon (OMC) of fine aerosol were the major contributors affecting on visibility impairment. Total contributions to light extinction were calculated as $631.0Mm^{-1}$ for the worst-case and $64.4Mm^{-1}$ for the best-case. The concentrations of aerosol component for the worst-case were 38.4 times and 45.5 times larger than those of the best-case for $(NH_4)_2SO_4$ and $NH_4NO_3$, respectively. At lower visibility condition, in which extinction coefficient was higher than $400Mm^{-1}$, extinction coefficient varied according to the relative humidity variation regardless of $PM_{2.5}$.

Evaluation of Sampling Methodology for the Measurement of Polycyclic Aromatic Hydrocarbons in the Atmosphere (대기 중 다환방향족 탄화수소의 측정을 위한 시료포집방법의 비교평가)

  • 백성옥;최진수
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.14 no.1
    • /
    • pp.43-62
    • /
    • 1998
  • This study was carried out to investigate the influence of different sampling methods on the measured concentrations of polycyclic aromatic hydrocarbons (PAH) both in the vapor and particulate phases, and to evaluate the effects of ambient temperature and sampling duration on the losses of PAH associated with particle samples due to volatilization. The experimental protocol of this study is consisted of two parts. The first part is related to the comparison of PAH concentrations measured by 4 different sampling systems, each of which involves different sampling principles for comparison purposes, including a medium-volume sampler with XAD-2 adsorbent, a high-volume sampler with polyurethane foam (PUF), two identical low-volume samplers: one with XAD-2 and the other with PUF, respectively. The second part of this study is to quantitatively estimate the losses of particulate PAH samples by volatilization during sampling, using two identical low-volume samplers: one was used for changing the filters every 3 hrs, 6 hrs, 12 hrs, and 24 hrs sampling, while the other was maintained for continuous 48 hours sampling without changing the filter. The concentrations of volatile PAH including 2-3 rings appeared to be significantly affected by the type of adsorbent. Measured levels of these lower-molecular weight PAH by XAD-2 adsorbent were much higher than those by PUF for both high-volume and low-volume sampling. PUF was found to give rise to unknown components that interfered with the PAH analysis, even after extensive clean-up. In addition, the retention efficiency of PUF for lower molecular weight PAH was subject to a large variation, being significantly influenced by sampling conditions such as ambient temperature. However, the effect of sampling methods with different adsorbents on the measured levels of semi-volatile compounds including 4 rings PAH such as fluoranthene, pyrene, BaA and chrysene, was not so much significant as more volatile PAH compounds. It was also clear from this study that volatilization losses of the semi-volatile PAH collected on the filters were inevitably occurred during prolonged sampling, and hence the results obtained from conventional sampling methods may not be expected to yield an accurate distribution of PAH between the vapor and particulate phases.

  • PDF

Development of an Automated Diffusion Scrubber-Conductometry System for Measuring Atmospheric Ammonia

  • Lee, Bo-Kyoung;Lee, Chong-Keun;Lee, Dong-Soo
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.6
    • /
    • pp.2039-2044
    • /
    • 2011
  • A semi-continuous and automated method for quantifying atmospheric ammonia at the parts per billion level has been developed. The instrument consists of a high efficiency diffusion scrubber, an electrolytic on-line anion exchange device, and a conductivity detector. Water soluble gases in sampled air diffuse through the porous membrane and are absorbed in an absorbing solution. Interferences are eliminated by using an anion exchange devises. The electrical conductivity of the solution is measured without chromatographic separation. The collection efficiency was over 99%. Over the 0-200 ppbv concentration range, the calibration was linear with $r^2$ = 0.99. The lower limit of detection was 0.09 ppbv. A parallel analysis of Seoul air over several days using this method and a diffusion scrubber coupled to an ion chromatography system showed acceptable agreement, $r^2$ = 0.940 (n = 686). This method can be applied for ambient air monitoring of ammonia.

EXISTENCE THEOREMS FOR FIXED FUZZY POINTS WITH CLOSED α-CUT SETS IN COMPLETE METRIC SPACES

  • Cho, Yeol-Je;Petrot, Narin
    • Communications of the Korean Mathematical Society
    • /
    • v.26 no.1
    • /
    • pp.115-124
    • /
    • 2011
  • In this paper, some fuzzy fixed point theorems for fuzzy mappings are established by considering the nonempty closed $\alpha$-cut sets. Some importance observations are also discussed. Our results clearly extend, generalize and improve the corresponding results in the literatures, which have given most of their attention to the class of fuzzy sets with nonempty compact or closed and bounded $\alpha$-cut sets.

Manufacture of Aluminum Alloy Rheology Materials Using Spiral Stirring Equipment (나선형 기계 교반 장치를 이용한 Al 합금 레오로지 소재의 제조)

  • Bae, J.W.;Han, S.H.;Kang, C.G.
    • Transactions of Materials Processing
    • /
    • v.17 no.1
    • /
    • pp.9-12
    • /
    • 2008
  • Recently, industries and academic institutes have been interested in the rheology forming technology for light weight materials. However, this rheocasting process has advantages such as the high initial investment cost and the lower mechanical properties than thixocasting. In this study, the continuous fabrication of rheological material with a spiral stirring equipment(mechanical stirring system) was newly devised to overcome the disadvantages of rheocasting process. The experimental parameters were stirring time($0{\sim}1200sec$), stirring velocity ($0{\sim}100rpm$) and stirring temperature($650{\sim}680^{\circ}C$). The optimal conditions for fabricated rheological material of A6061 alloy were stirring time at 300sec, stirring velocity at 60rpm and stirring temperature at $650^{\circ}C$. At these results, the equivalent diameter was $45{\sim}65{\mu}m$, mean roundness was $1.4{\sim}1.6$ and Vickers hardness was 60Hv.

SOME BEST PROXIMITY POINT RESULTS OF SEVERAL 𝛼-𝜓 INTERPOLATIVE PROXIMAL CONTRACTIONS

  • Deng, Jia;Liu, Xiao-lan;Sun, Yan;Rathour, Laxmi
    • Nonlinear Functional Analysis and Applications
    • /
    • v.27 no.3
    • /
    • pp.533-551
    • /
    • 2022
  • In this paper, we introduce several types 𝛼-𝜓 interpolative proximal contractions and provide some sufficient conditions to prove the existence of best proximity points for these contractions in metric spaces. In the case of proximal contraction of the first kind, these metric spaces are not necessarily complete. Meanwhile, some new results can derive from our results. Finally, some examples are provided to show the validity of our results.

Thermophilic Sewage Sludge Digestion by Anaerobic Sequencing Batch Reactor (고온 협기성 연속회분식 공정에 의한 도시하수슬러지 소화)

  • 허준무;박종안;이종화;손부순;장봉기
    • Journal of environmental and Sanitary engineering
    • /
    • v.14 no.3
    • /
    • pp.130-138
    • /
    • 1999
  • The feasibility of municipal sewage sludge digestion was investigated by using thermophilic anaerobic sequencing batch reactor(ASBR). One-day settle time was enough for the high performance of solid-liquid separation. The conversion of semi-continuous mode to sequencing batch mode is easily achieved without any adverse effects, although the large amount of sludge equal to the volume ratio of 0.3~06 to reactor volume was added in the feed step of the start-up. The ASBRs had higher conversion capability of organics to biogas than the control reactor. Gas yields of the ASBRs were increased by the average of 50% over the control reactor across a range of hydraulic retention time(HRT)s from 10days to 5days. The thermophilic reactors showed higher gas production than mesophilic reactor. Removal efficiencies of organic matter exceeded 80% on the basis of supernatants, except that at the reactor. Solid-liquid separation was essential in the performance of the ASBR, especially, at the lower HFT. The ASBRs were highly efficient in the retention of activated biomass within the reactor. thus compensating for increased equivalent organic loading rate through increased solids retention times followed by the increased solids, while maintaining shorter HRTs.

  • PDF

Analytical approaches to the charging process of stratified thermal storage tanks with variable inlet temperature (변온유입 성층축열조의 충전과정에 대한 해석적 접근)

  • Yoo, Hoseon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.1
    • /
    • pp.43-54
    • /
    • 1997
  • This paper presents an approximate analytical solution to a two-region one-dimensional model for the charging process of stratified thermal storage tanks with variable inlet temperature in the presence of momentum-induced mixing. Based on the superposition principle, an arbitrary-varying inlet temperature is decomposed into inherent discontinuous steps and continuous intervals approximated as a finite number of piecewise linear functions. This approximation allows the temperature of the upper perfectly-mixed layer to be expressed in terms of constant, linear and exponential functions with respect to time. Applying the Laplace transform technique to the model equation for the lower thermocline layer subject to each of three representative interfacial conditions yields compact-form solutions, a linear combination of which constitutes the final temperature profile. A systematic method for deriving solutions to the plug-flow problem having polynomial-type boundary conditions is also established. The effect of adiabatic exit boundary on solution behaviors proves to be negligible under the actual working conditions, which justifies the assumption of semi-infinite domain introduced in the solution procedure. Finally, the approximate solution is validated by comparing it with an exact solution obtained for a specific variation of inlet temperature. Excellent agreements between them suffice to show the necessity and utility of this work.

  • PDF

Morphological and Physiological Characteristics of Acclimated Liriodendron tulipifera Tree Produced by Several Types of In Vitro Germination Culture (백합나무 체세포배 기내발아 방식에 따른 순화묘의 형태적 및 생리적 특성)

  • An, Chan Hoon;Yi, Jae Seon;Moon, Heung Kyu;Kim, Yong Wook
    • Journal of Korean Society of Forest Science
    • /
    • v.101 no.1
    • /
    • pp.158-162
    • /
    • 2012
  • The acclimatization of in vitro propagated plants is an important step to produce vigorous plants for clonal forestry and in vitro micro-environment may affect the growth in ex vitro condition. To monitor in vitro environmental effects on the growth in ex vitro condition, several culture systems such semi-solid medium(SS), temporary immersion bioreactor(TIB) and continuous immersion bioreactor(CIB) culture types were tested to compare for the growth of acclimated plants of Liriodendron tulipifera. Results suggested that morphological characters, stomatal conductance, evapotranspiration and chlorophyll contents of acclimated plants were affected by the different of in vitro culture conditions. CIB type of culture was resulted to the lowest value in the biomass of acclimated plants. Net photosynthsis rate of CIB was the same level as those of SS and TIB. However, stomatal conductance, evapotranspiration and $CO_2$ partial pressure in the intercellular air space were lower than those of SS and TIB. The amounts of chlorophyll a, b and carotenoids were also lower than those of the other two culture systems. TIB, showing a little lower or higher value than SS in many growth character, is recommended rather than CIB to produce healthy yellow poplar plants in ex situ condition.

Comparison of Real Time Water Soluble Organic Carbon Measurements by Two PILS-TOC Analyzers (PILS-TOC를 이용한 실시간 대기 중 수용성 유기탄소 비교 측정)

  • Park, Da-Jeong;Kang, Seokwon;Lee, Taehyoung;Shin, Hye-Jung;Shon, Zang-Ho;Bae, Min-Suk
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.32 no.6
    • /
    • pp.633-641
    • /
    • 2016
  • Two identical Particle Into Liquid Samplers-Total Organic Carbon (PILS-TOC) were operated to measure fine particle Water Soluble Organic Carbon (WSOC) for one week on Feb. in 2016. The dual instrument operations provided validated WSOC concentrations to have a continuous WSOC measurement during the sample analysis period. Both PILS-TOC instruments were operated downstream of an carbon denuder to remove positive adsorption artifacts associated with semi-volatile organic compounds. Comparison of WSOC showed good agreement each other. The linear regression had a coefficient of determination ($r^2$) of 0.92 and a regression slope of 1.01 for the first period. The lower collection efficiency due to lower steam temperature is discussed. In addition, the potential primary source related to WSOC based on the comparison of black carbon (BC) concentrations is explained. The results of good agreement between two PILS-TOC measurements can provide the validation of WSOC cooperations and knowledge regarding the origins of WSOC and their behaviors.