• 제목/요약/키워드: Lower attachments

검색결과 20건 처리시간 0.02초

Effect of implant- and occlusal load location on stress distribution in Locator attachments of mandibular overdenture. A finite element study

  • Alvarez-Arenal, Angel;Gonzalez-Gonzalez, Ignacio;deLlanos-Lanchares, Hector;Martin-Fernandez, Elena;Brizuela-Velasco, Aritza;Ellacuria-Echebarria, Joseba
    • The Journal of Advanced Prosthodontics
    • /
    • 제9권5호
    • /
    • pp.371-380
    • /
    • 2017
  • PURPOSE. The aim of this study is to evaluate and compare the stress distribution in Locator attachments in mandibular two-implant overdentures according to implant locations and different loading conditions. MATERIALS AND METHODS. Four three-dimensional finite element models were created, simulating two osseointegrated implants in the mandible to support two Locator attachments and an overdenture. The models simulated an overdenture with implants located in the position of the level of lateral incisors, canines, second premolars, and crossed implant. A 150 N vertical unilateral and bilateral load was applied at different locations and 40 N was also applied when combined with anterior load at the midline. Data for von Mises stresses in the abutment (matrix) of the attachment and the plastic insert (patrix) of the attachment were produced numerically, color-coded, and compared between the models for attachments and loading conditions. RESULTS. Regardless of the load, the greatest stress values were recorded in the overdenture attachments with implants at lateral incisor locations. In all models and load conditions, the attachment abutment (matrix) withstood a much greater stress than the insert plastic (patrix). Regardless of the model, when a unilateral load was applied, the load side Locator attachments recorded a much higher stress compared to the contralateral side. However, with load bilateral posterior alone or combined at midline load, the stress distribution was more symmetrical. The stress is distributed primarily in the occlusal and lateral surface of the insert plastic patrix and threadless area of the abutment (matrix). CONCLUSION. The overdenture model with lateral incisor level implants is the worst design in terms of biomechanical environment for the attachment components. The bilateral load in general favors a more uniform stress distribution in both attachments compared to a much greater stress registered with unilateral load in the load side attachments. Regardless of the implant positions and the occlusal load application site, the stress transferred to the insert plastic is much lower than that registered in the abutment.

Evaluation of two interforaminal implants and implant-assisted removable dentures on stress distribution: an in vitro study

  • Bilhan, Selda Arat;Geckili, Onur;Cilingir, Altug;Bozdag, Ergun;Bilhan, Hakan
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제45권4호
    • /
    • pp.199-206
    • /
    • 2019
  • Objectives: In mandibular edentulism, the treatment option with a two-interforaminal implant-retained bridge and a removable partial denture is rarely evaluated in literature. The aim of this in vitro study was to evaluate the stress distribution of this treatment option by comparing it with traditional treatment options with interforaminal implants in the edentulous mandible. Materials and Methods: Two interforaminal implants were placed in a formalin-fixed cadaver mandible, and overdentures with three different types of attachments were fabricated: (1) two ball attachments and an overdenture, (2) a Dolder bar and an overdenture, and (3) screw-retained two-implant inter-canine porcelain fused to a metal bridge and an implant-assisted removable denture (IARD) with precision attachments. Three biting conditions were generated for each denture type, and the strains were documented under vertical loading of 100 N. Results: The calculated strain values from measured strains in all measurement sites and loading conditions for the screw-retained two-implant intercanine porcelain fused to a metal bridge and a cast framework partial denture with precision attachments situation were lower than in the other scenarios (P<0.05). Conclusion: Within the limitations of the present study, it can be concluded that an IARD may be a reasonable and valuable alternative to ball attachments or a bar in two interforaminal implants, especially when the patients prefer to be able to show their teeth even when they take out their removable dentures.

Comparison of retentive force and wear pattern of Locator® and ADD-TOC attachments combined with CAD-CAM milled bar

  • Chae, Sung-Ki;Cho, Won-Tak;Choi, Jae-Won;Bae, Eun-Bin;Bae, Ji-Hyeon;Bae, Gang-Ho;Huh, Jung-Bo
    • The Journal of Advanced Prosthodontics
    • /
    • 제14권1호
    • /
    • pp.12-21
    • /
    • 2022
  • PURPOSE. The purpose of this study was to investigate changes in retention and wear pattern of Locator® and ADD-TOC attachments on a digital milled bar by performing chewing simulation and repeated insertion/removal of prostheses in fully edentulous models. MATERIALS AND METHODS. Locator (Locator®; Zest Anchors Inc., Escondido, CA, USA) was selected as the control group and ADD-TOC (ADD-TOC; PNUAdd Co., Ltd., Busan, Republic of Korea) as the experimental group. A CAD-CAM milled bar was mounted on a master model and 3 threaded holes for connecting a bar attachment was formed using a tap. Locator and ADD-TOC attachments were then attached to the milled bar. Simulated mastication and repeated insertion/removal were performed over 400,000 cyclic loadings and 1,080 insertions/removals, respectively. Wear patterns on deformed attachment were investigated by field emission scanning electron microscopy. RESULTS. For the ADD-TOC attachments, chewing simulation and repeated insertion/removal resulted in a mean initial retentive force of 24.43 ± 4.89 N, which were significantly lower than that of the Locator attachment, 34.33 ± 8.25 N (P < .05). Amounts of retention loss relative to baseline for the Locator and ADD-TOC attachments were 21.74 ± 7.07 and 8.98 ± 5.76 N (P < .05). CONCLUSION. CAD-CAM milled bar with the ADD-TOC attachment had a lower initial retentive force than the Locator attachment. However, the ADD-TOC attachment might be suitable for long-term use as it showed less deformation and had a higher retentive force after simulated mastication and insertion/removal repetitions.

CSP 를 이용한 정밀부착형 국부의치에 관한 임상적 연구 (A Clinical Study on CSP Attachment Partial Denture)

  • 김광남
    • 대한치과보철학회지
    • /
    • 제19권1호
    • /
    • pp.7-16
    • /
    • 1981
  • The technology of precision attachments has developed at such a pace that from a very few T-shaped attachments and bar attachments from the years 1915 to 1935 since removable bridge utilizing a T-shaped intracoronal attachment was constructed by Dr. Herman E.S. Chayes in 1906. There are now more than 120 models of the most diversified designs, ready made or laboratory fashioned. In 1971, 126 attachments were listed and classified by Mensor in his E M Attachment Selector. This selector consists of five charts giving specifications as to type, vertical dimensions, application, type of resilience, size of movement, type of retention and type of material and alloy. Thus the E M Attachment Selector is a useful guide for dentists to choose the attachment for his patients. But dentists should apply the attachment in each patient's case according to an accurate diagnosis and treatment plan. This paper is a case report of removable partial dentures utilizing CSP, PD and Bar attachment on a patient who needed full mouth reconstruction. Patient has right first, second molar and left first molar on the upper arch and also left first molar, first premolar and right canine on the lower arch. (Fig. 5)All remaining teeth are relatively healthy in their supporting tissues. On upper arch, ring shape CSP attachment was designed on left first molar and modified ring shape CSP attachment was designed on right first and second molar as the direct retainer of the removable partial denture. Full palatal coverage was used as the major connector in this case. (Fig. 23) On lower arch, author first splinted with a fixed bridge between left first molar and second premolar and a splint bar between left second premolar and right canine. (Fig. 11) A lower removable partial denture in which was designed with an Aker clasp on the left first molar and a PD attachment on .the right canine was constructed. (Fig. 17) This denture could get additional support from anterior splint bar. After both removable partial dentures were delivered to the patient (Fig. 26), author evaluated function of the dentures and supporting structures of the abutment teeth by means of clinical and X-ray examinations for eighteen months. According to the examination data author came to the conclusion that the prognosis of this case was excellent.

  • PDF

Attachment를 이용한 후방연장 국소의치에 의한 압력분산에 관한 3차원 유한요소분석 (A THREE DIMENSIONAL FINITE ELEMENT STRESS ANALYSIS ON THE FORCE DISTRIBUTION BY DISTAL EXTENSION PARTIAL DENTURES EMPLOYING ATTACHMENTS)

  • 신상완;안원준;정연진;이영수;심광섭;유광희
    • 대한치과보철학회지
    • /
    • 제36권6호
    • /
    • pp.878-887
    • /
    • 1998
  • Although attachments have been utilized for a retainer of removable prostheses during several decades, there is little information on the force distribution by the attachments. This study was undertaken to evaluate the stress patterns developed by partial dentures employing rigid attachments on the supporting structures. Four types of the mandibular removable partial dentures were designed depending upon the position of the rigid attachment and the existency of lingual bracing. Under 100N of vertical and 25N of lateral loads on the 1st and 2nd lower molar of partial denture, stress distribution patterns and displacement were analysed with three dimensional finite element method by ANSYS version 5.3. 1. The highest stresses were concentrated on the distal alveolar crest of posterior abutment and the second stresses on the apical region of posterior abutment in the models. 2. The greatest displacement were shown on the distal alveolar crest of posterior abutment and the second displacement on the distal alveolar crest of anterior abutment in the models. 3. There was little difference between the models with intraoral attachment and those with extracoronal attachment. 4. There was little difference between the models with and without the lingual bracing.

  • PDF

각종(各種) 충전제(充塡劑)를 배합(配合)한 천연(天然)고무의 가황체(加黃體)의 특성(特性)에 관(關)한 연구(硏究)(II)(가황특성(加黃特性) 및 물리적성질(物理的性質)) (A Study on Vulcanization Characteristics and Physical Properties for the Filler Compounded NR Vulcanizates.(II))

  • 최재운;홍청석;허동섭
    • Elastomers and Composites
    • /
    • 제20권1호
    • /
    • pp.13-24
    • /
    • 1985
  • It is generally agreed that strong linkages exist between rubber chains and reinforcing filler particles. The purpose of this study is to examine the effect of rubber-filler attachments on the various mechanical properties of the rubber. In particular, the modulus and strength will be altered by these attachments. For this study, the curing properties are examined by means of ODR (Oscillating Disk Rheometer), the physical properties by means of Instrong. The results of this study can be summarized as follows. In the ODR test, the carbon black filled stock has shorter scorch time than gum stock and, the silica and clay filled stock has longer scorch time than gum stock. In the modulus, ten sile and swelling properties, the vulcanizates filled with carbon black had higher those values than inorganic filler loaded NR vulcanizates, but the rebound rate showed that the silica filled NR vulcanizates was lower than other inorganic filler contained NR vulcanizates and the ISAF filled NR vulcanizates was lower than other carbon block contained NR vulcanizates.

  • PDF

Effects of a tunnel ventilation system within the tie-stall barn environment upon the productivity of dairy cattle during the winter season

  • Sarentonglaga, Borjigin;Sugiyama, Tatsuhiro;Fukumori, Rika;Nagao, Yoshikazu
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제32권5호
    • /
    • pp.748-756
    • /
    • 2019
  • Objective: The objective of this study was to examine the effect of using a tunnel ventilation system within the dairy barn environment upon the productivity of dairy cows during the winter season. Methods: The study was performed at the University Farm, Faculty of Agriculture, Utsunomiya University. Twenty-one Holstein dairy cows (5 heifers and 16 multiparous) were enclosed in a stall barn. Unventilated (UV) and tunnel-ventilated (TV) was operated by turns every other week, and a number of key parameters were measured in the barn, including tunnel ventilation output, temperature, relative humidity, gas concentrations (oxygen [$O_2$], carbon dioxide [$CO_2$], and ammonia [$NH_3$]). Also, skin and rectal temperature, respiratory rate, blood gas concentrations, and bacterial count were measured from nipple attachments on ten cows. The amount of fodder left uneaten, and general components and somatic cell count of the milk were measured. Results: As for our dairy barn environment, air temperature dropped significantly with the passage of time with TV. Humidity was significantly higher with TV at 0600 h compared to UV, while $CO_2$ and $NH_3$ concentrations with UV were significantly higher than with TV at 0000 h and 0600 h. Skin temperature was significantly lower with TV compared to UV at 0000 h and 0600 h. Respiratory rate was also significantly lower at 0600 h with TV than with UV. Bacterial count for the nipple attachments was significantly lower with TV than with UV at 0600 h. The amount of leftover fodder was significantly less with TV in comparison with UV. Conclusion: Our results suggest that a TV system in the winter barn results in environmental improvements, such as reductions in unfavorable gas concentrations and bacterial growth. Consequently, it is expected that barns utilizing a TV system will be beneficial for both animal health and production.

Effects of overdenture attachment systems with different working principles on stress transmission: A three-dimensional finite element study

  • Turker, Nurullah;Buyukkaplan, Ulviye Sebnem
    • The Journal of Advanced Prosthodontics
    • /
    • 제12권6호
    • /
    • pp.351-360
    • /
    • 2020
  • PURPOSE. The aim of the present study was to compare the stress distributions on the dental implants, abutments, and bone caused by different overdenture attachment types under functional chewing forces. MATERIALS AND METHODS. The 3D finite element models of the mandible, dental implants, attachment types, and prostheses were prepared. In accordance with a conventional dental implant supported overdenture design, the dental implants were positioned at the bone level in the canine teeth region bilaterally. A total of eight models using eight different attachment systems were used in this study. All the models were loaded to simulate chewing forces generated during the centric relationship (450 N), lateral movement (400 N), protrusive movement (400 N), and also in the presence of a food mass unilaterally (200 N). Stress outputs were obtained as the maximum principal stress and the equivalent von-Mises stress. RESULTS. In all attachment types, higher stress values were observed in the abutments, dental implants, and bone in the magnet attachments in different loading conditions. The highest stress values were observed among the magnet systems in the components of the Titanmagnetics model in all loading conditions (stresses were 15.4, 17.7, and 33.1 MPa on abutment, dental implant, and bone, respectively). The lowest stress value was observed in the models of Zest and O-Ring attachments. CONCLUSION. The results of the present study implied that attachment types permitting rotation and tolerating various angles created lower stresses on the bone, dental implants, and abutments.

Comparative study of prosthetic complications associated with the bar-clip, milled bar, and Locator attachments for implant overdentures: a retrospective study

  • Yoon, Kye-Won;Heo, Ji-Ye;Hwang, Hee-Sung;Kim, Chul-Hoon;Kim, Bok-Joo;Kim, Jung-Han
    • 대한치과의사협회지
    • /
    • 제54권12호
    • /
    • pp.1024-1034
    • /
    • 2016
  • Purpose. The purpose of this study was to compare the type and frequency of prosthetic complications associated with attachment types for implant overdenture. Material and methods. In this retrospective study, 38 patients (mean age, 63.5 years) have been treated with implant overdentures from 2007 to 2014. Ten patients received a bar-clip attachment. Eleven patients had received a milled bar with Locator attachment. Seventeen patients had received a Locator attachment. The mean follow-up period was 36.9 months (range, 15-83 months). The type and frequency of prosthetic complications was recorded. The frequency was analyzed to determine the statistical difference among the 3 different attachments by using one-way ANOVA (${\alpha}=.05$) and Bonferroni post hoc method at a 5% level of significance. Results. The total number of prosthetic complications was higher in the bar-clip attachment (55 events) than in the milled bar with Locator attachment (39 events) and the Locator attachment (34 events). There were no statistically significant differences, and the most common prosthetic complication was the loss of retention. In the bar-clip attachment group, the average frequency of prosthetic complications was 3.0 events per prosthesis during the first year. In the milled bar with Locator attachment and Locator attachment groups, the average frequencies were 1.45 events and 2.35 events, respectively. Statistically significant differences were observed in the frequency of the complication. (p = .043) Conclusions. Compared to the bar-clip attachment, implant overdentures that use milled bars with the Locator attachment have a significantly lower incidence of prosthetic complications in the first year of follow-up after placement.

  • PDF

굴착기 암가 연결핀의 구조해석 (Structural Analysis of Excavator Arm and its Connection Pins)

  • 한문식;조재웅
    • 한국생산제조학회지
    • /
    • 제20권1호
    • /
    • pp.7-12
    • /
    • 2011
  • Hydraulic excavator in digging at the construction machinery is a widely used mechanical device. Excavator attachments are taken with structural load and fatigue during digging under applied reaction. Fatigue analysis is done at joint pin between bucket and arm of front attachment at excavator under the force of hydraulic cylinder in operation. It is analyzed how load can be supported at the lower driving body applied on the bucket. In this study, the deformation of arm and the fatigue result are examined when reaction force is applied on the attachment of excavator.