• Title/Summary/Keyword: Lower Operating Temperature

Search Result 339, Processing Time 0.022 seconds

Variation of Operating Clearance Depending on Cooling Methods of High-Speed Roller Bearings for Aerospace Applications (항공용 고속 롤러베어링의 냉각 방식에 따른 작동간극 변화)

  • Jisu Park
    • Tribology and Lubricants
    • /
    • v.39 no.4
    • /
    • pp.123-132
    • /
    • 2023
  • In this study, the expansion, stress, and operating clearance of bearing elements during operation are observed using the inner/outer ring temperature test data of a 3.0×106 DN-class roller bearing. The operating clearance characteristics of inner-/outer-ring cooling (IORC) bearings are compared to those of inner-ring cooling (IRC) bearings. For IRC bearings, the thermal expansion of the outer ring is the most important factor in clearance variation. As a result, the operating clearance is less than the initial clearance of 61 ㎛, and the operating clearance decreases to 0.5 ㎛ at 25,500 rpm. Conversely, the temperature of the outer ring of IORC bearings is lower than that of IRC bearings, so the operating clearance is kept smaller. When the coolant flow rate to the outer ring is approximately 1.5 to 2.0 L/min, the temperature difference between the inner and outer rings is minimized and the operating clearance is maintained at a significantly lower level than IRC bearings. Small operating clearances are expected to be effective in reducing cage slip and skid damage in roller bearings. The results and analysis procedures of this study can be utilized to design of bearing clearance, lubricant flow rate, and assembled interference in the early design stage of aerospace roller bearings.

Evaluation of Heat Transfer Characteristics of PV Module with Different Backsheet (백시트 종류에 따른 태양전지 모듈의 방열 특성 평가)

  • Bae, Soohyun;Oh, Wonwook;Kang, Yoonmook;Lee, Hae-Seok;Kim, Donghwan
    • Current Photovoltaic Research
    • /
    • v.6 no.2
    • /
    • pp.39-42
    • /
    • 2018
  • When the PV module is illuminated in a high temperature region, solar cells are also exposed to the high temperature external environment. The operating temperature of the solar cell inside the module is increased, which causes the power drops. Various efforts have been made to reduce the operating temperature and compensate the power of solar cells according to the outdoor temperature such as installing of a cooling system. Researches have been also reported to lower the operating temperature of solar cells by improving the heat dissipation properties of the backsheet. In this study, we conducted a test to measure the internal temperature of each module components and the external temperature when the light was irradiated according to the surrounding temperature. Backsheets with different thermal conductivities were compared in the test. Finally, in order to explain the temperature difference between the solar cell and the outside of the module, we proposed an evaluation method of the heat transfer characteristics of photovoltaic modules with different backsheet.

Chemical Beam Deposition of $MgF_2$ Thin Films (화학선 증착법에 의한 $MgF_2$ 박막제조)

  • 박보현;백성기
    • Journal of the Korean Ceramic Society
    • /
    • v.33 no.3
    • /
    • pp.299-306
    • /
    • 1996
  • We invesgated the fesibility of thin films deposition by pyrolysis of metalorganic precursors using chemical beam deposition (CBD) process. We attempted to understand the effects of deposition variables such as substrate temperature operating pressure effusion cell temperature and H2 partial pressure on the properties of MgF2 grown by CBD. Mg(tfac)2 was used as a precursor. MgF2 thin films were always grown in an amorphous state and crystallized bypost-annealing. he higher the substrate temperature and the lower the operating pressure the less the impurities I the deposited MgF2 thin films. H2 gas has to be supplied for the pyrolitic reaction of Mg(tfac)2 decomposition. MgF2 films annealed in H2 have lower C impurity than those annealed in O2. But their crysatllinity was independent of annealing atmosphere. The optimum conditions for the prepara-tion of MgF2 films by CBD process were as following : The substrate temperature 55$0^{\circ}C$ the operating pressure 10-4 torr; effusion cell temperature 21$0^{\circ}C$ the percentage of H2 100% Post-annealing in H2 gas was required to remove residual carbon and to form MgF2 crystalline phase.

  • PDF

Expansion of Operating Range and Reduction of Engine out Emission in Low Temperature Diesel Combustion with Boosting (과급을 이용한 저온 디젤 연소의 운전영역 확장 및 배기 배출물 저감)

  • Shim, Eui-Joon;Han, Sang-Wook;Jang, Jin-Young;Park, Jung-Seo;Bae, Choong-Sik
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.17 no.5
    • /
    • pp.31-38
    • /
    • 2009
  • Supercharging system was adopted to investigate the influence of boost pressure on operating range and exhaust emissions by using a supercharger at low temperature diesel combustion (LTC) condition in a 5-cylinder 2.7 L direct injection diesel engine. The experimental parameters such as injection quantity, injection timing, injection pressure and exhaust gas recirculation (EGR) rate were varied to find maximum operating range in LTC condition. As a result of adopting increased boost pressure in LTC, wider operating range was achieved compared with naturally aspirated condition due to increased mixing intensity. Increased boost pressure resulted in lower hydrocarbon (HC) and carbon monoxide (CO) emissions due to increased swirl rate and mixing intensity, which induced complete combustion. Moreover, increased boost pressure in LTC resulted in much lower soot emissions compared with high speed direct injection (HSDI) condition.

An Experimental Study on Characteristics of Cooler by Oil Pressure for Decreasing Heat Load in Cold Storage (냉동창고 내 열부하 감소를 위한 유압 구동식 냉각기의 특성에 관한 실험적 연구)

  • Kim, Jae-Dol
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.33 no.8
    • /
    • pp.1116-1122
    • /
    • 2009
  • As a result of this study, we reached the following conclusions. With appropriate setting of oil pressure and flow rate, it operated same rotation speed with existing cooler by electrical transmission. In initial operation, a temperature of a cold storage is lower rapidly. As an internal temperature of a cold storage is lower, a decreasing rate of temperature is lower. As a result of comparing the both type, the cooler of oil pressure type showed the following results. The decreasing rate of temperature was more faster and shorter operating time was more shorter than existing cooler of electric type. The actual case of a cold storage, the cooler of oil pressure type can prevent quality deterioration and decrease power consumption. As an internal temperature of a cold storage is lower, power consumption increased rapidly, the oil pressure type showed lower power consumption. COP of two of these types decreased continuously as the internal temperature of a cold storage being reach setting temperature, and that of oil pressure type showed higher amount about 25%. As a setting temperature is lower, the number of refrigerator's operating times are less and operating time is longer, so power consumption is increased in the maintenance of a cold storage's internal temperature, power consumption of hydraulic type showed lower amount about 21~25% in two of these types.

Optimal Operation Condition of Spray Drying Sorber for Simultaneous Removal of Acidic and Organic Gaseous Pollutants (산성 및 유기성 가스의 동시제거를 위한 준건식 세정시스템의 적정 운전 조건)

  • 백경렬;구자공
    • Journal of Environmental Science International
    • /
    • v.10 no.1
    • /
    • pp.59-64
    • /
    • 2001
  • The effect of major operating parameters in spray drying sorber(=SDS) for automatic control for the simultaneous removal of acidic and organic gaseous pollutants from solid waste incinerator was performed. The field experiment was carried out in pilot scale test for the quantification of major operating parameters of hydrophilic and the hydrophobic pollutants. The removal efficiencies of $SO_2$and HCI in the 5wt% slurry condition were being increased with the increase of the stoichiometric ration which is the molecular ratio of lime to the pollutant concentration, and with the decrease of inflow flue gas temperature in the pilot SDS reactor. The removal efficiency along the height of spray drying sorber was closely related to the temperature profile, and more than 90% of total removal efficiency was achieved in an absorption region. For the removal of acidic gas the optimum operating condition considering the economics and a stable operation is the 5wt% of slurry concentration, 1.2 of stoichiometric ratio and 25$0^{\circ}C$ of inflow flue gas temperature. For the organic gases of benzene and toluene the removal efficiencies were 20-60% which is much lower than that of acidic gas. The best removal efficiency was obtained at 1.5 of stoichiometric ratio and 25$0^{\circ}C$ of inflow flue gas temperature. The organic\`s removal efficiency along the height of spray drying sorber was quite different from that of acidic gas, that is, more than 60% of the total removal efficiency for benzene and 90% of the total removal for toluene were achieved in the dried adsorption region, which was formed at the lower or exit part of the reactor.

  • PDF

Analysis of AC losses in HTS coils by temperature variations

  • Kim, Yungil;Lee, Ji-Kwang;Lee, Seyeon;Kim, Woo-Seok;Lee, Siyoung;Choi, Kyeongdal
    • Progress in Superconductivity and Cryogenics
    • /
    • v.20 no.4
    • /
    • pp.50-54
    • /
    • 2018
  • We analyzed the temperature dependency of the AC losses in high temperature superconducting (HTS) coils. In the case of a short sample of an HTS tape, the magnetization loss at 4.2 K could be higher than the one at 77 K for a same transport current. It happens when the perpendicular magnetic field is above a certain magnitude. The AC loss characteristics of solenoidal coils have been analyzed at the temperatures of 65 K and 77 K. They were categorized by the aspect ratios. The operating current of a solenoid was normally set about 70 % of the critical current. An HTS solenoid with the same operating current of 77 K causes larger AC losses at 65 K in the most cases of the HTS solenoids. We also analyzed the AC loss characteristics due to the temperature variations for three types of superconducting magnetic energy storages. Two of them were solenoidal types and the other was toroidal type. The results showed the tendency for the coils to have higher AC losses at lower temperature with the same operating currents and scenarios.

Study on the Operating Characteristics with Load Condition in Hybrid Solar Heating System during Spring Season (봄철 태양열 하이브리드 시스템의 부하조건 변화에 따른 운전특성 연구)

  • Pyo, Jong-Hyun;Kim, Won-Seok;Cho, Hong-Hyun;Ryu, Nam-Jin
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1418-1423
    • /
    • 2009
  • This study describes experimental study on the performance characteristics with load condition in hybrid solar heating system during spring season. The room temperatures, the hot water conditions and the lower part temperatures of heat storage tank were changed to analyze the system performances. As a results, the hot water was significantly affected by the ambient temperature. The indoor setting temperature affected the solar fraction. When the low part temperature of the storage tank increased, the temperature of the hot water rose and the temperature of the hot water in morning was affected by the ambient temperature.

  • PDF

Performance Analysis in Direct Internal Reforming Type of Molten Carbonate Fuel Cell (DIR-MCFC) according to Operating Conditions (직접내부개질형 용융탄산염 연료전지(DIR-MCFC)의 운전 조건에 따른 성능 분석)

  • JUNG, KYU-SEOK;LEE, CHANG-WHAN
    • Journal of Hydrogen and New Energy
    • /
    • v.33 no.4
    • /
    • pp.363-371
    • /
    • 2022
  • In this study, the operation characteristics of the internal reforming type molten carbonate fuel cell (MCFC) were studied using computational fluid dynamics (CFD) analysis according to the steam to carbon ratio (S/C ratio), operating temperature, and gas utilization. From the simulation results, the distribution of gas composition due to the electrochemical reaction and the reforming reaction was predicted. The internal reforming type showed a lower temperature difference than the external reforming type MCFC. As the operating temperature decreased, less hydrogen was produced and the performance of the fuel cell also decreased. As the gas utilization rate decreased, more gas was injected into the same reaction area, and thus the performance of the fuel cell increased.

Study for Synthetic Oil Performance Test Comparing with Mineral Gear oil in an Agitator Gear Box:Power consumption, Temperature, Oil & parts life for the Heavy load gear box in the Phosphoric Acid Plant (뉴스초점 - 광유와 합성유의 에너지 소비량, 온도변화 등의 성능시험 비교 고찰)

  • Lee, Jae Keun
    • Journal of the Korean Professional Engineers Association
    • /
    • v.45 no.6
    • /
    • pp.28-32
    • /
    • 2012
  • Namhae chemical is one of the largest fertilizer manufacturing company in Korea which company has operating 4 unit agitator gear boxes and producing variety kinds of fertilizer production. The gearbox operating temperature of agitator is approximated in $55^{\circ}C{\sim}90^{\circ}C$ and required to keep operating continuous without stopping. The system required high performance oil and longer oil drain interval as limited workforce in maintenance team. It was lubricated by mineral gear oil of ISO VG 320 and also need to change to new oil frequently. Namhae Chemical would expect to keep stable operating condition without shut down and consider, lower cost of operation and equipment protection.

  • PDF