• Title/Summary/Keyword: Lower Active-bridge

Search Result 20, Processing Time 0.023 seconds

A Control Method to Improve Power Conversion Efficiency of Three-level NPC-Based Dual Active Bridge Converter (Three-Level NPC-Based Dual Active Bridge Converter의 도통손실 절감을 위한 새로운 스위칭 방법)

  • Lee, Jun-Young;Choi, Hyun-Jun;Kim, Ju-Yong;Jun, Jee-Hoon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.22 no.2
    • /
    • pp.150-158
    • /
    • 2017
  • This study proposes a new pulse-width modulation switching pattern for the low conduction loss of a three-level neutral point clamped (NPC)-based dual-active bridge (DAB) converter. The operational principle for a bidirectional power conversion is a phase-shift modulation. The conventional switching method of the three-level NPC-based DAB converter shows a symmetric switching pattern. This method has a disadvantage of high root-mean-square (RMS) value of the coupling inductor current, which leads to high conduction loss. The proposed switching method shows an asymmetrical pattern, which can reduce the RMS value of the inductor current with lower conduction loss than that of the conventional method. The performance of the proposed asymmetrical switching method is theoretically analyzed and practically verified using simulation and experiment.

Buffeting Responses of Concrete Cable-stayed Bridge Considering Turbulent Characteristics of Bridge Site (현장 풍속 특성을 반영한 콘크리트 사장교의 버페팅 응답)

  • Kim, Sung-Ho;Yhim, Sung Soon;Kwon, Soon-Duck
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.2A
    • /
    • pp.97-104
    • /
    • 2011
  • This study presents the aerodynamic admittance function of bridge girder under turbulent flow generated from wind velocity spectrum measured at bridge site. Three dimensional buffeting analysis of concrete cable-stayed bridge were performed considering aerodynamic admittance functions obtained from four different methods. It is revealed from the analysis that vertical buffeting responses considering proper aerodynamic admittance functions were just half of that neglecting aerodynamic admittance function. Grid turbulence was found to relatively lower the aerodynamic admittance function at low frequency range, and to underestimate the buffeting wind forces. It is recommended to use the aerodynamic admittance function evaluated from flutter derivatives or measured at active turbulence in order to properly predict the buffeting responses of bridges.

Effect of Trunk Inclination Angles on Trunk Muscle Activity and Subjective Difficulties During Supine Bridge Exercise with a Suspension Device

  • Kim, Jwa-Jun;Park, Se-Yeon
    • PNF and Movement
    • /
    • v.18 no.3
    • /
    • pp.315-321
    • /
    • 2020
  • Purpose: Recent studies have indicated that applying different inclination angles and suspension devices could be a useful way of performing exercises that include the co-activation of the trunk muscles. Present study was to examine the influences of changes in the inclination angle during trunk muscle activity while engaging in a bridge exercise with a suspension device. Methods: 18 healthy, physically active male volunteers completed three trunk inclination angles (15°, 30°, and 45°) for bridge exercise variations. The surface electromyography responses of the rectus abdominis, internal oblique (IO), erector spinae (ES), and rectus femoris (RF), as well as the subjective difficulty (Borg RPE score), were investigated during these bridge exercises. Results: The bridge with a 45° inclination angle suspension significantly increased the muscular activities of the RA and RF and increased the Borg RPE scores (p<0.05). The bridge with a 15° suspension significantly elevated the ES activities when compared to the other conditions. Conclusion: The present study demonstrated that a higher inclination angle could not activate the overall trunk muscles during the bridge exercise. The RA and RF produced greater activation during the bridge exercise with the higher inclination angle. On the other hand, the activities of the erector spine were greater during the bridge exercise with the lower inclination angle. The present study suggests that applying a low trunk inclination angle for the supine bridge exercise is suitable for activating the erector spine muscles.

A New Mode Changable Asymmetric Full Bridge DC/DC Converter having 0 ~ 100 % Duty Ratio (0 ~ 100 % 시비율을 갖는 새로운 모드 가변형 비대칭 풀 브리지 DC/DC 컨버터)

  • Shin, Yong-Saeng;Roh, Chung-Wook;Hong, Sung-Soo;Han, Sang-Kyoo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.15 no.2
    • /
    • pp.103-110
    • /
    • 2010
  • In this paper, a new mode changeable asymmetric full bridge dc/dc converter is proposed to solve the freewheeling current problem of the conventional zero voltage switching(ZVS) phase shift full bridge(PSFB) dc/dc converter of low output voltage and high output current applications. The proposed converter is operated as an asymmetric full bridge converter when the duty cycle is less than 50% and active clamp full bridge converter when the duty cycle is greater than 50%. As a result, since its freewheeling current is eliminated, the conduction loss is lower than that of the conventional ZVS PSFB dc/dc converter. Moreover, ZVS of all power switches can be ensured along a wide load ranges and output current ripple is very small. Therefore, high efficiency of the proposed converter can be achieved. Especially since its operation mode is changed to the active clamp full bridge converter during hold up time and can be operated with 50~100% duty ratio, it can produce the stable output voltage along wide input voltage range. The operational principles, theoretical analysis and design considerations are presented. To confirm the operation, validity and features of the proposed converter, experimental results from a 1.2kW($400V_{dc}/12V_{dc}$) prototype are presented.

A Novel type of High-Frequency Transformer Linked Soft-Switching PWM DC-DC Power Converter for Large Current Applications

  • Morimoto Keiki;Ahmed Nabil A.;Lee Hyun-Woo;Nakaoka Mutsuo
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.2
    • /
    • pp.216-225
    • /
    • 2006
  • This paper presents a new circuit topology of DC busline switch and snubbing capacitor-assisted full-bridge soft-switching PWM inverter type DC-DC power converter with a high frequency link for low voltage large current applications as DC feeding systems, telecommunication power plants, automotive DC bus converters, plasma generator, electro plating plants, fuel cell interfaced power conditioner and arc welding power supplies. The proposed power converter circuit is based upon a voltage source-fed H type full-bridge high frequency PWM inverter with a high frequency transformer link. The conventional type high frequency inverter circuit is modified by adding a single power semiconductor switching device in series with DC rail and snubbing lossless capacitor in parallel with the inverter bridge legs. All the active power switches in the full-bridge inverter arms and DC busline can achieve ZVS/ZVT turn-off and ZCS turn-on commutation operation. Therefore, the total switching losses at turn-off and turn-on switching transitions of these power semiconductor devices can be reduced even in the high switching frequency bands ranging from 20 kHz to 100 kHz. The switching frequency of this DC-DC power converter using IGBT power modules is selected to be 60 kHz. It is proved experimentally by the power loss analysis that the more the switching frequency increases, the more the proposed DC-DC converter can achieve high performance, lighter in weight, lower power losses and miniaturization in size as compared to the conventional hard switching one. The principle of operation, operation modes, practical and inherent effectiveness of this novel DC-DC power converter topology is proved for a low voltage and large current DC-DC power supplies of arc welder applications in industry.

Analysis of the Behaviors of Continuous parts in Continuous PSC Girders Bridges (PSC 연속 거더교의 연속화부 거동에 관한 해석적 연구)

  • 구민서;김훈희;정영도
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2002.10a
    • /
    • pp.404-411
    • /
    • 2002
  • The PSC 2-span-continuous-bridge by Up-Down Method on construction process is used for this research. It is measured the strain of lower-steel-plate at continuous section on the active range of negative moment at the stage of introducing compressive stress to bottom-plate and compared with results of structural analysis. On the basis of these results, it is confirmed the introduced compressive stress tか bottom-plate. The object of this research is presenting the degree of continuity at the stage of lifting up process.

  • PDF

Boundary Current Mode Operated Bridgeless Boost Converter for Power Factor Correction (역률개선을 위해 경계전류모드로 동작하는 브리지리스 부스트 컨버터)

  • Yu Byung-Gyu;Lee Sung-Se;Han Sang-Kyu;Moon Gun-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2003.11a
    • /
    • pp.90-94
    • /
    • 2003
  • Recently, many nations have released standard such as IEC 1000-3-2 and IEEE 519 which impose a limit on the harmonic current drawn by equipment connected to AC line in order to prevent the distortion of an AC line. Among the wide variety of active methods for improving power factor and harmonic distortion, the boost converter is very effective because it has a continuous line current , small choke filter and high power factor. In high power application, however, the bridge diode loss in the boost converter has made the efficiency lower and the temperature of the board higher. A new approach without bridge diode to make the same characteristics of the conventional boost converter has also been developed. This paper present the comparisons between the continuous current mode(CCM) operated conventional boost converter and the boundary current mode(BCM) operated the bridgeless boost converter for high efficiency and high power factor.

  • PDF

A Study on Efficiency and Characteristic of Zero Voltage Switched Half-Bridge Converter and Forward Converter (영전압 스위칭 하프브리지 컨버터와 포워드 컨버터의 효율 및 특성에 관한 연구)

  • Seo, J.K.;Kim, Y.;Baek, S.H.;Kwon, S.D.
    • Proceedings of the KIEE Conference
    • /
    • 1998.11a
    • /
    • pp.147-149
    • /
    • 1998
  • In this paper, zero voltage switched half bridge converter and an active-clamped, zero voltage switched forward converter equipped with self-driven synchronous rectifier is designed and investigated for high efficiency BC-DC converter. A synchronous rectifier is has a lower conduction power loss than shottky diode rectifier. The purpose of this paper is to investigate the effect of parasitic inductance in a synchronous rectifier of DC-DC converters and examine overall efficiency of zero voltage switched DC-DC converters.

  • PDF

Level Number Effect on Performance of a Novel Series Active Power Filter Based on Multilevel Inverter

  • Karaarslan, Korhan;Arifoglu, Birol;Beser, Ersoy;Camur, Sabri
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.2
    • /
    • pp.711-721
    • /
    • 2018
  • This paper presents a single-phase asymmetric half-bridge cascaded multilevel inverter based series active power filter (SAPF) for harmonic voltage compensation. The effect of level number on performance of the proposed SAPF is examined in terms of total harmonic distortion (THD) and system efficiency. Besides, the relationship between the level number and the number of switching device are compared with the other multilevel inverter topologies used in APF applications. The paper is also aimed to demonstrate the capability of the SAPF for compensating harmonic voltages alone, without using a passive power filter (PPF). To obtain the required output voltage, a new switching algorithm is developed. The proposed SAPF with levels of 7, 15 and 31 is used in both simulation and experimental studies and the harmonic voltages of the load connected to the point of common coupling (PCC) is compensated under two different loading conditions. Furthermore, very high system efficiency values such as 98.74% and 96.84% are measured in the experimental studies and all THD values are brought into compliance with the IEEE-519 Standard. As a result, by increasing the level number of the inverter, lower THD values can be obtained even under high harmonic distortion levels while system efficiency almost remains the same.

Dual Mode Phase-Shifted ZVS-PWM Series Load Resonant High-Frequency Inverter for Induction Heating Super Heated Steamer

  • Hisayuki Sugimura;Hidekazu Muraoka;Tarek Ahmed;Srawouth Chandhaket;Eiji Hiraki;Mutsuo Nakaoka;Lee, Hyun-Woo
    • Journal of Power Electronics
    • /
    • v.4 no.3
    • /
    • pp.138-151
    • /
    • 2004
  • In this paper, a constant frequency phase shifting PWM-controlled voltage source full bridge-type series load resonant high-frequency inverter using the $4^{th}$ generation IGBT power modules is presented for innovative consumer electromagnetic induction heating applications, such as a hot water producer, steamer and super heated steamer. The bridge arm side link passive capacitive snubbers in parallel with each power semiconductor device and AC load side linked active edge inductive snubber-assisted series load resonant tank soft switching inverter with a constant frequency phase shifted PWM control scheme is evaluated and discussed on the basis of the simulation and experimental results. It is proved from a practical point of view that the series load resonant and edge resonant hybrid high-frequency inverter topology, what is called, DE class type, including the variable-power variable-frequency regulation function can expand zero voltage soft switching commutation area even under low output power setting ranges, which is more suitable and acceptable for newly developed induction heated dual pack fluid heaters. Furthermore, even the lower output power regulation mode of this high-frequency load resonant tank inverter circuit is verified so that this inverter can achieve ZVS with the aid of the single auxiliary inductor snubber.