• Title/Summary/Keyword: Lower(net) heating value

Search Result 6, Processing Time 0.018 seconds

The Heat Management of PEM Fuel Cell Stack (운전 조건에 따른 PEMFC 스택 열 관리)

  • Son, Ik-Jae;Lee, Jong-Hyun;Nam, Gi-Young;Ko, Jae-Jun;Ahn, Byung-Ki
    • Journal of Hydrogen and New Energy
    • /
    • v.21 no.3
    • /
    • pp.184-192
    • /
    • 2010
  • PEM fuel cell produces electric power, water and heat by the electrochemical reaction of hydrogen and oxygen. The heating value is dependent on the molar enthalpy of vaporization of product water and the performance loss. In this paper, the heating value of fuel cell stack has been studied under various stack operating temperatures to achieve more efficient heat management. A technology using the molar enthalpy of vaporization of product water is suggested to reduce heat-up time during start-up of a fuel cell vehicle.

Tritium extraction in aluminum metal by heating method without melting

  • Kang, Ki Joon;Byun, Jaehoon;Kim, Hee Reyoung
    • Nuclear Engineering and Technology
    • /
    • v.54 no.2
    • /
    • pp.469-478
    • /
    • 2022
  • Tritium was extracted from tritium-contaminated aluminum samples by heating it in a high-temperature furnace at 200, 300, or 400 ℃ for 15 h. The extracted tritium was analyzed by using a liquid scintillation counter (LSC); the sample thicknesses were 0.4 and 2 mm. The differences in tritium extraction over time were also investigated by cutting aluminum stick samples into several pieces (1, 5, 10, and 15) with the same thickness, and subsequently heating them. The results revealed that there are most of the hydrated material based on tritium on the surface of aluminum. When the temperature was increased from 200 or 300 ℃-400 ℃, there are no large differences in the heating duration required for the radioactivity concentration to be lower than the MDA value. Additionally, at the same thickness, because the surface of aluminum is only contaminated to tritiated water, cutting the aluminum samples into several pieces (5, 10, and 15) did not have a substantial effect on the tritium extraction fraction at any of the applied heating temperatures (200, 300, or 400 ℃). The proportion of each tritium-release materials (aluminum hydrate based on tritium) were investigated via diverse analyses (LSC, XRD, and SEM-EDS).

A Study on the Practical Use of Alternative Energy for Agriculture in Korea (우리나라 농업의 대체에너지 활동 실태에 관한 연구)

  • 홍지형
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.35 no.3
    • /
    • pp.81-90
    • /
    • 1993
  • Groundwater and animal wastes are typical example which are underutilized resources than their value in agriculture. This paper was to investigate the actual patterns of utilization of water curtain for greenhouses and methane gas utilization from swine wastes in a view point of promoting more efficient use of alternative energy. The results from measurements can be summarized as follows : 1.It was estimated that the maximum heating load per l0a was around 23,2804/hr and the heating load at January showed 3.93X 1064 respectively for strawberry greenhouses with insulation by the water curtain. 2.The average heating cost of the greenhouse with water curtain system amounted to about 75,000 Won per l0a. This result suggested that the greater cultivated area provides less heating cost. 3.The operating volume was about 73 percent of the optimum size of the digester. The net available methane gas rates of the produced gas remained close to 62 percent, But the conventional and small size of the digester was maintained at a lower level of around 20 to 29 percent. 4.It appeared that major problems of biogas production system were required to maintain the temperature of the fermentation above ambient temperature and the optimum volume of digester.

  • PDF

Performance and Economic Analysis of Natural Gas/Syngas Fueled 100 MWth Chemical-Looping Combustion Combined Cycle Plant (천연가스/합성가스 이용 100 MWth 매체순환연소 복합발전 플랜트의 성능 및 경제성 평가)

  • Park, Young Cheol;Lee, Tai-yong;Park, Jaehyeon;Ryu, Ho-Jung
    • Korean Chemical Engineering Research
    • /
    • v.47 no.1
    • /
    • pp.65-71
    • /
    • 2009
  • In this study, performance and economic analysis of natural gas/syngas fueled 100 MWth chemical-looping combustion (CLC) combined cycle plant were performed. Net efficiency of both cases was 53~54%, corresponding to previous research. We used Chemical Engineering Plant Cost Index and Guthrie method to evaluate plant cost. For syngas fueled CLC combined cycle plant, the plant cost was higher since lower heating value(LHV) of syngas was lower than that of natural gas and cost of electricity(COE) was also higher since the cost of syngas was higher than that of natural gas. By sensitivity analysis, it was shown that the cost of syngas should be less than 5.3 $/GJ in order to make COE lower than 5.8 ¢/kWh which was COE of natural gas fueled CLC combined cycle plant.

Improvement of lower hybrid current drive systems for high-power and long-pulse operation on EAST

  • M. Wang;L. Liu;L.M. Zhao;M.H. Li ;W.D. Ma;H.C. Hu ;Z.G. Wu;J.Q. Feng ;Y. Yang ;L. Zhu ;M. Chen ;T.A. Zhou;H. Jia;J. Zhang ;L. Cao ;L. Zhang ;R.R. Liang;B.J. Ding ;X.J. Zhang ;J.F. Shan;F.K. Liu ;A. Ekedahl ;M. Goniche ;J. Hillairet;L. Delpech
    • Nuclear Engineering and Technology
    • /
    • v.54 no.11
    • /
    • pp.4102-4110
    • /
    • 2022
  • Aiming at high-power and long-pulse operation up to 1000 s, some improvements have been made for both 2.45 GHz and 4.6 GHz lower hybrid (LH) systems during the recent 5 years. At first, the guard limiters of the LH antennas with graphite tiles were upgraded to tungsten, the most promising material for plasma facing components in nuclear fusion devices. These new guard limiters can operate at a peak power density of 12.9 MW/m2. Strong hot spots were usually observed on the old graphite limiters when 4.6 GHz system operated with power >2.0 MW [B. N. Wan et al., Nucl. Fusion 57 (2017) 102019], leading to a reduction of the maximum power capability. With the new limiters, 4.6 GHz LH system, the main current drive (CD) and electron heating tool for EAST, can be operated with power >2.5 MW routinely. Long-pulse operation up to 100 s with 4.6 GHz LH power of 2.4 MW was achieved in 2021 and the maximal temperature on the guard limiters measured by an infrared (IR) camera was about 540 ℃, much below the permissible value of tungsten material (~1200 ℃). A discharge with a duration of 1056 s was achieved and the 4.6 GHz LH energy injected into the plasma was up to 1.05 GJ. Secondly, the fully-active-multijunction (FAM) launcher of 2.45 GHz system was upgraded to a passive-active-multijunction (PAM), for which the density of optimum coupling was relatively low (below the cut-off value). Good coupling with reflection coefficient ~3% has been achieved with plasma-antenna distance up to 11 cm for the new PAM. Finally, in order to eliminate the effect of ion cyclotron range of frequencies (ICRF) wave on 4.6 GHz LH wave coupling, the location of the ICRF launcher was changed to a port that is located 157.5° toroidally from the 4.6 GHz LH system and is not magnetically connected.

Studies on the Quality Evaluation and Metal Content of Sanitary Canned Kamju Beverage (위생캔으로 제조한 감주 음료의 품질 평가와 금속물질 함량에 관한 연구)

  • 허윤행
    • Journal of environmental and Sanitary engineering
    • /
    • v.15 no.2
    • /
    • pp.18-26
    • /
    • 2000
  • In order to improve the quality of Kamju(sikhae), Korean traditional sweat fermentated rice drink, Kamju made with laboratory fermenting from both covered barley malt and that added to commercial $\alpha-amylase$ and commercial sikhae can were investigated and analyzed ad follows 1. The amylase activities in L-malt(laboraory made malt), C-malt(commercial malt) were 25,065 units, 20,498 units at $60^{\circ}C$ and when heating at $60^{\circ}C$ for one hour their heat stability was getting lower and while at $70^{\circ}C$ after 2 hours both their heat stability was under 21%. 2. The external appearance, of all samples, in beating test, flipper, springer and leaker test were excellent and good valued. On the open test of sample can, head space was 7.9~9.0mm, net weight 247~250g, 432~435g, pH 4.96-5.76, Brix 13.2~14.0 and vacuum degree was 29~35cmHg. 3. The sucrose content of sample 1~5 was 8,57~10.01% highest ammount than sample 6(0.91%) 7(0.43%) and maltose content of sample 1~5 was 0.65~1.41% lower than 6 was 7.91% and 7 was 8,36%. The good traditional flavor texture and saccharides components content of glucose of sample 1~5 was 1.09~1.51, 6(3.86%), 7(3.97%), fructose content of sample 1~5 was 0.45~0.95%, 6(2.76%), 7(2.81%), maltotriose and raffinose of sample 1~5 were 0.04~0.291, 6(0.61%), 7(2.81%), and solid content of sample 1~5(3.1~3.8) was lower than 6(10.25%), 7(10.09%). 4. The result of sensory test as measured as lemone yellow of sample 6 and milky of sample 7, and weetness, flavor, color, traditional texture and sensory value for sample 1~5(3.1~3.8) was lower degree than that for 6(4.5), 7(4.0). 5. Among the heavy metals analyzed from sample cans, tin, iron and lead content for sample 1~5 were 31.95~36.71ppm, 5.84~6.39ppm and 0.075~0.09ppm while their content of sample 6.7, tin, 32.91ppm, 32.87ppm, iron 5.51ppm, 5.41ppm and lead, 0.074ppm, 0.079ppm.

  • PDF