• 제목/요약/키워드: Low-voltage ride-through

검색결과 45건 처리시간 0.029초

전원사고 시 3상 계통연계 인버터의 전원 전압 고속 검출 방법 (High Speed Grid Voltage Detection Method for 3 Phase Grid-Connected Inverter during Grid Faults)

  • 최형진;송승호;정승기;최주엽;최익
    • 한국태양에너지학회 논문집
    • /
    • 제29권5호
    • /
    • pp.65-72
    • /
    • 2009
  • The new method is proposed to improve high speed detection of grid voltage phase and magnitude during a voltage dip due to a grid faults. Usually, A LPF(Low Pass Filter) is used in the feedback loop of PLL (Phase Locked Loop) system because the measured grid voltage contains harmonic distortions and sensor noises. so, a new design method of the loop gain of the PI -type controller in the PLL system is proposed with the consideration of the dynamics of the LPF. As a result, a better transient response can be obtained with the proposed design method. The LPF frequency and PI controller gain are designed in coordination according to the steady state and dynamic performance requirement. This paper shows the feasibility and the usefulness of the proposed methods through the computer simulation and the lab-scale experiments.

전원 전압 불평형시 계통연계형 인버터의 유효전력 리플 억제를 위한 듀얼 전류제어기 구현과 출력 전력의 실시간 제한 알고리즘 (Implementation of Dual Current Controller and Realtime Power Limiting Algorithm in Grid-connected Inverter during Unbalanced Voltage Conditions)

  • 송승호;김정재
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제55권1호
    • /
    • pp.54-60
    • /
    • 2006
  • A power limiting algorithm is proposed for stable operation of grid-connected inverter in case of grid voltage unbalance considering the operation limit of inverter. During the voltage unbalance the control performance of Inverter. is degraded and the output power contains 120Hz ripple due to the negative sequence of voltage. In this paper, conventional dual sequence current controller is implemented to solve these problems using separated control of positive and negative sequence. Especially the maximum power limit which guarantees the maximum rated current of the inverter is automatically calculated as the instant grid voltage changes. As soon as the voltage recovers the proposed algorithm can return to the normal power control mode accomplishing low voltage ride through. Proposed algorithm is verifed using PSCAD/EMTDC simulations and tested experimentally at 4.4kW wind turbine simulator set-up.

초퍼저항 및 de-loading 협조제어를 통한 해상풍력 연계용 HVDC시스템 DC전압 상승 억제 방안 (DC Voltage Build-Up Suppression Scheme of HVDC System for Offshore Wind Farm Connection using Chopper Resistor and de-loading)

  • 이형진;강병욱;김재철
    • 전기학회논문지
    • /
    • 제66권5호
    • /
    • pp.750-756
    • /
    • 2017
  • This paper presents a method for DC voltage control of HVDC system connection of offshore wind farms. In the event of fault in AC grid, HVDC system need to meet LVRT regulations. When HVDC system meet LVRT regulation, unbalance is caused between power input and power output for DC link. Therefore, LVRT regulation lead to DC voltage increase of HVDC system. To control the DC voltage increase, the chopper resistor can be suggested. In this paper, DC voltage suppression is proposed using chopper resistor and de-loading. The effectiveness of the chopper resistor was verified using PSCAD/EMTDC.

자속 추종을 통한 DFIG 시스템의 LVRT 기법 (LVRT Scheme for Doubly Fed Induction Generator Systems Based on Flux Tracking Method)

  • 박선영;전영환;이동명
    • 전기학회논문지
    • /
    • 제62권8호
    • /
    • pp.1059-1065
    • /
    • 2013
  • Doubly Fed Induction Generator(DFIG) systems occupy the largest proportion of worldwide wind energy generation market. DFIG systems are very sensitive to grid disturbances especially to voltage dips due to the structure of the stator connected to grid. In the past, when a grid fault occurs generators are separated from grid(trip method) in order to protect the systems. Nowadays, due to the growing penetration level of wind power, many countries have made some requirements that wind turbines are required to have Low Voltage Ride Through(LVRT) capability during grid faults. In this paper, a flux tracking LVRT control strategy based on system modeling equations is proposed. The validity of the proposed strategy is verified through computer simulations.

ESS PCS의 LVRT 실증시험에 대한 연구 (Experimental Results for LVRT of an ESS PCS)

  • 윤선재;박기우;홍진욱;김희중;김영근
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2019년도 전력전자학술대회
    • /
    • pp.549-550
    • /
    • 2019
  • 각국의 계통연계 규정에서는 계통연계 인버터에 대한 계통 안정도 기여(Grid support)를 필수로 규정하고 있다. 그 중에는 계통의 저압 이상 발생 시 계통연계 인버터가 Fault를 발생하지 않고 계통과의 동기를 유지하며 지속 동작하는 Low Voltage Ride-Through(LVRT) 기능과 저압 이상에 대한 계통 기여를 위한 무효 주입 기능이 있다. 본 논문에서는 해당 기능들을 국내 LVRT 실증 단지에서 2MW ESS PCS를 통해 수행한 결과에 대해 서술한다.

  • PDF

A Calculation Method for the Nonlinear Crowbar Circuit of DFIG Wind Generation based on Frequency Domain Analysis

  • Luo, Hao;Lin, Mingyao;Cao, Yang;Guo, Wei;Hao, Li;Wang, Peng
    • Journal of Power Electronics
    • /
    • 제16권5호
    • /
    • pp.1884-1893
    • /
    • 2016
  • The ride-through control of a doubly-fed induction generator (DFIG) for the voltage sags on wind farms utilizing crowbar circuits by which the rotor side converter (RSC) is disabled has being reported in many literatures. An analysis and calculation of the transient current when the RSC is switched off are of significance for carrying out the low voltage ride through (LVRT) of a DFIG. The mathematical derivation is highlighted in this paper. The zero-state and zero-input responses of the transient current in the frequency domain through a Laplace transformation are investigated, and the transient components in the time domain are achieved. With the characteristics worked out from the linear resolving without modeling simplification, the selection of the resistance in the linear crowbar circuit and the value conversion from a linear circuit to a nonlinear one is proposed to setup the attenuation rate. In terms of grid code requirements, the theoretical analysis for the time constant of the transient components attenuation insures the controllability when the excitation of the RSC is resumed and it guarantees the reserved time for the response of the reactive power compensation. Simulations are executed in MATLAB/SIMPOWER and experiments are carried out to validate the theoretical analysis. They indicate that the calculation method is effective for selection of the resistance in a crowbar circuit for LVRT operations.

회전체 진동 데이터의 AC/DC 성분 데이터 획득 및 분석 장치 (An Acquisition and Analysis Equipment of Dynamic/Static Data on a Rotating Vibration)

  • 이정석;유등열;이철
    • 디지털산업정보학회논문지
    • /
    • 제5권4호
    • /
    • pp.127-137
    • /
    • 2009
  • This paper is proposed that in-output Digital module is acquired a vibration signal of a rotating machinery by Data Acquisition System. The module is designed to get ride of nose through low pass filter on the vibration signal from sensors and set the gain value for being able to sampling AC to DC, and also the sampled data by sampler and the conversed data by DIP/FPGA is supplied to the analyzer for analysis at a software tool. The DIP(Digital Signal Processor) of the Digital input/output Board makes Average voltage, Peak to Peak voltage, RMS(Root Mean Square) and Gap voltage, also FFT(Fast Fourier Transform) for rotating vibration diagnosis.

LPN(Low Pass Notch) PLL 기법을 활용한 계통연계형 PCS에서의 LVRT 알고리즘 구현 (Implementation of LVRT algorithm of Grid-Connected PCS with Low Pass Notch PLL Technique)

  • 신동설;이경준;김희제;이종필;김태진;유동욱
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2014년도 전력전자학술대회 논문집
    • /
    • pp.516-517
    • /
    • 2014
  • 태양광과 풍력발전 등 분산전원의 대용량 발전이 기존 계통에 미치는 영향이 커짐에 따라, 계통 전압의 안정적인 유지를 위해 필요한 지원이 계통에 연계되는 분산전원들에게 요구되고 있다. 특히나 Low Voltage Ride Through (LVRT) 시에는 계통에서 탈락되지 않는 것은 물론이고, 계통전압 회복을 돕기위해 무효전력을 주입해야 한다. 이러한 사고 상황에서 계통에서 탈락되지 않고 계속적인 계통지원을 위해서는 빠르고 정확한 위상 추종이 필수적이다. 본 논문은 고조파에 강인하고 응답특성이 우수한 Low Pass Notch (LPN) PLL 기법을 LVRT에 적용하여 이의 우수함을 확인한다.

  • PDF

풍력발전용 PMSG 계통연계 컨버터 직류 링크 전압제어 알고리즘 (DC-link Voltage Control Algorithm of PMSG Grid Connected Converter for Wind Power System)

  • 이헌수;조영표;유지윤
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2012년도 추계학술대회 논문집
    • /
    • pp.11-12
    • /
    • 2012
  • 최근 풍력 발전이 시스템이 전체 전력망에서 차지하는 비중이 커짐에 따라 세계 각국에서는 LVRT(Low Voltage Ride Through) 규정을 제정하여 계통 연계된 풍력 발전 시스템이 전력망의 안정화에 부정적 영향을 미치지 않도록 하고 있다. 계통 전압 사고 상황에서 LVRT 규정을 만족 시키게 되면 발전기에서 발생된 유효전력과 계통으로 전달되는 유효전력 사이의 불균형으로 직류 링크전압이 상승하게 된다. 본 논문은 이러한 상황에서 계통연계 컨버터의 직류 링크전압을 일정하게 제어하는 알고리즘을 제안한다.

  • PDF

풍력 수용 한계량 향상을 위한 발전기 무효전력 평활화 제어 기법 (Generator Control Method for Reactive Power Smoothing to increase Wind Power Penetration)

  • 최윤혁;이환익;이병준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.197-198
    • /
    • 2015
  • As the global to increase the wind power penetration in the power system, grid-integration standards have been proposed for the stable integration of the large-scale wind farm. Particularly, the low voltage ride through function has been emphasized, as it relates to the voltage and reactive power control of the wind turbine and the rest generators. This paper proposes the non-wind power generator control method in order to improve the wind power penetration. To prove the effectiveness of the proposed strategy, the simulation study is implemented in the Jeju power system. It can improve the wind power penetration by the effective control of the control generators.

  • PDF