• 제목/요약/키워드: Low-spin

검색결과 462건 처리시간 0.024초

원통 내 스핀업 유동에서의 관성진동에 관한 수치해석적 연구 (Numerical Study on Inertial Oscillations in the Spin-up of Fluid in a Circular Cylinder)

  • 서용권
    • 한국해양공학회지
    • /
    • 제15권3호
    • /
    • pp.9-19
    • /
    • 2001
  • In this paper we present the aspect of inertial oscillation typically observed in the spin-up of fluids at low Rossby numbers in a circular cylinder. Numerical computations for the quasi three-dimensional equation as well as one-dimensional equation are performed to estimate the predictability of the one-dimensional equation with Ekman pumping/suction models. It is assumed that the discrepancy between the two results may be attributed to the inertial oscillation The detailed analysis to the numerical results reveals that the axial plane is dominated by a comparatively strong oscillatory flows caused by the inertial oscillation. In view of the fact that the time-averaged flow field however agrees to the Taylor-Proudman theorem, it is recommended that further analysis is needed to obtain an improved one-dimensional model like the Reynolds-averaged Navier-Stokes equation for turbulent flows.

  • PDF

GaOOH 선구체의 스핀코팅에 의한 GaN 박막의 성장 (Growth of GaN Thin-Film from Spin Coated GaOOH Precursor)

  • 이재범;김선태
    • 한국재료학회지
    • /
    • 제17권1호
    • /
    • pp.1-5
    • /
    • 2007
  • GaN thin fan were grown by spin coated colloidal GaOOH precursor. Polycrystalline GaNs with crystalline size of $10{\sim}100nm$ were grown on $SiO_2$ substrate. The shape of crystallite above $900^{\circ}C$ had the hexagonal plate and column type. X-ray diffraction patterns for them correspond to those of the hexagonal wurtzite GaN. With increasing droplets. i.e, thickness of deposited layers, XRD intensity increased. PL (photoluminescence) spectrum consisted with an weak near band-edge emission at 3.45 eV and a broad donor-acceptor emission band at 3.32 eV. From the low temperature PL measurement on GaN grown at $800^{\circ}C$ that the shallow donor-acceptor recombination induced emission was more intense than the near band-edge excitonic emission.

Detection of Magnetic Nanoparticles and Fe-hemoglobin inside Red Blood Cells by Using a Highly Sensitive Spin Valve Device

  • Park, Sang-Hyun;Soh, Kwang-Sup;Hwang, Do-Guwn;Rhee, Jang-Roh;Lee, Sang-Suk
    • Journal of Magnetics
    • /
    • 제13권1호
    • /
    • pp.30-33
    • /
    • 2008
  • A highly sensitive, giant magnetoresistance-spin valve (GMR-SV) biosensing device with high linearity and very low hysteresis was fabricated by photolithography. The detection of magnetic nanoparticles and Fe-hemoglobin inside red blood cells using the GMR-SV biosensing device was investigated. When a sensing current of 1 mA was applied to the current electrode in the patterned active devices with an area of $2{\times}6{\mu}m^2$, the output signals were about 13.35 mV. The signal from even one drop of human blood and nanoparticles in distilled water was sufficient for their detection and analysis.

스핀 스프레이 페라이트 플레이팅법으로 제작한 NixZnyFe3-x-yO4 박막의 결정학적 및 자기적 특성 (Structural and Magnetic Properties of NixZnyFe3-x-yO4 Films Prepared by Spin-Spray Ferrite Plating Method)

  • 김명호;장경욱
    • 전기학회논문지P
    • /
    • 제51권2호
    • /
    • pp.82-86
    • /
    • 2002
  • A series of $Ni_xZn_yFe_{3-x-y}O_4$ films were prepared by spin-spray ferrite plating on glass substrates from aqueous solution at $90[^{\circ}C]$. The magnetic properties in terms of contents of Ni and Zn in the plated films are presented. All the films are polycrystalline with spinel structure. At x+y=0.58, the film presents preferential orientation. As composition of y in the films increases grain size and void in the films increases, while saturation magnetization and coercive force of the films decrease.

Derivation of Cubic and Hexagonal Mesoporous Silica Films by Spin-coating

  • Pan, Jia-Hong;Lee, Wan-In
    • Bulletin of the Korean Chemical Society
    • /
    • 제26권3호
    • /
    • pp.418-422
    • /
    • 2005
  • By introducing spin-coating method to the evaporation induced self-assembly (EISA) process, a simple and reproducible route in controlling the mesophase of silica thin films has been developed for the first time in this work. When a comparatively solvent-rich Si-sol (The atomic ratio of TEOS : F127 : HCl : $H_2O$ : EtOH = 1 : 0.006 : 0.2 : 9.2 : 30) was used as coating solution, the mesophase of resultant silica films was selectively controlled by adjusting the spin-on speed. The cubic mesophase has been obtained from the coating at a low rpm, such as 600 rpm, while the 2-D hexagonal mesophase is formed at a high rpm, such as 2,500 rpm. At a medium coating speed, a mixture of cubic and hexagonal mesophase has been found in the fabricated films. The present results confirm that the evaporation rate of volatile components at initial step is critical for the determination of mesopore structures during the EISA process.

스핀스레이법 의한 $Fe{3-X}-Ni_XO_4$ 페라이트 박막의 제작과 그 특성 (The Properties and Manufacturing of $Fe{3-X}-Ni_XO_4$Films by Spin-Spray Ferrite Method)

  • 김명호;장경욱;부정기
    • 한국전기전자재료학회논문지
    • /
    • 제11권8호
    • /
    • pp.652-657
    • /
    • 1998
  • We have performed spin-spray ferrite plating of $Fe{_3}{-X}-Ni_XO_4$(X=0.17~0.26) films in the temperature region $T=80~95[^{\circ}C]$. A reaction solution and an oxidizing solution were supplied to a reaction chamber by supply pump. The solubility limit of Ni increases as the substrate temperature increase, from X=0.17 at $80[^{\circ}C]$ to X=0.26 at $95[^{\circ}C]$. All the films are polycrystalline with no preferential orientation, and the magnetization exhibits no definite anisotropy. Grain size in the films increases as X increases, reaching $0.87[\mu{m}]$ at X=0.26.

  • PDF

Correlation between Structures and Magnetism in Iron: Ferromagnetism and Antiferromagnetism

  • Lee, Dong-Kook;Hong, Soon-Cheol
    • Journal of Magnetics
    • /
    • 제12권2호
    • /
    • pp.68-71
    • /
    • 2007
  • Even a pure bulk Fe has a complicated magnetic phase and its magnetism is still needed to be clarified. In this study we investigated the magnetism of bcc and fcc bulk Fe with total energy calculations as functions of atomic volume. The full-potential linearized augmented plane wave method was adopted within a generalized gradient approximation. The ground state of bulk Fe is confirmed to be of ferromagnetic (FM) bcc. For fcc structured Fe an antiferromagnetic (AFM) state is more stable compared to FM states which exist as low spin and high spin states. The stable AFM states were found to accompany a tetragonal distortion, while the FM states remained in a cubic symmetry. At an expanded lattice constant a high spin FM state was calculated to be able to be stabilized with significant enhanced magnetic moment compared to the value of the ground state, bcc FM.

스핀 스프레이법으로 PC 기판에 제작한 산화아연 박막의 특성 (Property of Spin-sprayed ZnO Film on PC Substrate)

  • 홍정수;;;박용서;김경환
    • 반도체디스플레이기술학회지
    • /
    • 제17권3호
    • /
    • pp.27-30
    • /
    • 2018
  • In this study, ZnO film was deposited on polycarbonate substrate by spin-spray method at low substrate temperature of $85^{\circ}C$. Surface morphology of ZnO films was changed by adding citrate from rod to dense structure. As-deposited ZnO film indicated high transmittance above 80%. In case of the resistivity, as-deposited ZnO film had high resistivity due to the existence of organic substance in the film. However, organic substance was removed and resistivity was decreased to $3.9{\times}10^{-2}{\Omega}{\cdot}cm$, after UV irradiation.

고속회전시험기를 활용한 가스터빈 동익의 내구성 시험 (Spin Testing for the Endurance Verification of Gas Turbine Blades)

  • 이두영;김두수;손태하;구재량
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제4권1호
    • /
    • pp.19-24
    • /
    • 2018
  • 가스터빈 동익에 대한 지속적인 국산화 개발이 추진되어, 국내 정밀 주조 기술을 향상시키고, 동익의 유지 보수 비용을 낮추는 등의 직간접적인 긍정적 효과를 가져왔지만, 여전히 국산화 개발품이 발전소에서 안정적인 실사용이 가능한지에 대한 우려가 존재한다. 향상된 소재와 주조기술을 바탕으로 조직학적, 기계적 성질에서 충분한 품질을 확보하였더라도, 개발품을 대상으로 다양한 신뢰성 검증이 요구되는 이유이다. 고속회전시험기는 로터, 디스크 등의 회전체에 원심력을 가하여, 이에 따른 제품의 특성을 분석하기 위한 시험장비로 일반적으로 과속도시험을 통한 최종적인 품질검사에 주로 사용된다. 본 논문에서는 전력연구원에 구축된 고속회전시험기를 활용한 가스터빈 동익에 대한 과속도시험을 포함한 저주기피로시험 사례를 중심으로 신뢰성 시험 및 평가 결과를 기술하였다.

Ni(II)-$N_4$ 착이온의 낮은 스핀상태 ($D_{4h}$)와 높은 스핀상태 ($O_h$)간의 평형 ($N_4$ : 2,12-dimethyl-3,7,11,17-tetraazabicyclo-11,3,1-heptadeca-1(17),2,11,13,15-pentaene) (Equilibria between Low-spin State ($D_{4h}$) and High-spin State ($O_h$) of the Ni(II)-$N_4$ Complex Ion ($N_4$ : 2,12-dimethyl-3,7,11,17-tetraazabicyclo-11,3,1-heptadeca-1(17),2,11,13,15-pentaene))

  • 박유철;변종철;유만수
    • 대한화학회지
    • /
    • 제33권6호
    • /
    • pp.607-613
    • /
    • 1989
  • 물, 아세토니트릴, 아세톤 및 니트로메탄에서 Ni(II)-tetraamine 착물(tetraamine=2.12-dimethyl-3,7,11,17-tetraazabicyclo-11,3,1-heptadeca-1(17)2,11,13,15-pentaene)의 화학평형을 분광광도법을 이용하여 각각 관찰하였다. Ni(II)-tetraamine 착이온의 낮은 스핀($D_{4h}$) 구조와 높은 스핀($O_h$)구조간의 평형이 물, 아세토니트릴, 아세톤 용액에서는 나타났지만 니트로메탄 용액에서 나타나지 않았다. 평형상수와 반응엔탈피 및 반응엔트로피는 착물의 전자스펙트럼에 대한온도의 영향을 분석하므로써 결정하였다. $O_h$ 구조인 triplet 화학종의 형성은 발열과정으로 나타났었다. $D_{4h}$$O_h$간의 평형에 대한 용매와 전해질의 영향은 용매의 유전상수와 반응엔트로피로 설명할 수 있었다.

  • PDF