• Title/Summary/Keyword: Low-power System

Search Result 5,542, Processing Time 0.032 seconds

Liquid LPG Spray Characteristics With Injection Pressure Variation;Comparison with Diesel Spray (분사압력변화에 따른 액체 LPG 분무특성;디젤분무와의 비교)

  • Lim, Hee-Sung;Park, Kweon-Ha
    • 한국연소학회:학술대회논문집
    • /
    • 1999.10a
    • /
    • pp.21-26
    • /
    • 1999
  • Liquefied petroleum gas(LPG) has been used as motor fuel due to its low emissions and low cost. The fuel feeding system has been improved with stringent requirement for exhaust emissions. LPG carburation system was firstly introduced, then the system changed into a gas injection system controlled precisely, but those gas feeding system has a limitation on improving power output. In order to improve an engine performance, a multi-point port injection system was introduced recently, and a liquid direct injection system into a cylinder was suggested as a next generation system to maximize a fuel economy as well as a power. This study addresses the analysis of the LPG spray from diesel injectors. The spray images are visualized and compared with diesel sprays in a wide injection pressure range. The photographs show much wider dispersion of LPG sprays.

  • PDF

Trend of low voltage and high current Technology for DC-DC Converters (저전압대전류(低電壓大電流) DC-DC 컨버터 기술동향(技術動向))

  • Suzuki, Shotaro
    • Proceedings of the KIEE Conference
    • /
    • 2002.11d
    • /
    • pp.3-11
    • /
    • 2002
  • This paper presents the trend of low voltage and high current technology for DC-DC converters. It can be said that the output voltage of the on-board power supply has been rapidly moving forward a low voltage in proportion to the minuteness of the semiconductors. As for as its speed is concerned, the change of the market situation seems to be faster than that of R&D for the low voltage and high current products put out by power supply manufacturers. Here, the present situation and the trend of non-isolated type step-down DC-DC converter and isolated type DC-DC converter called "Brick" will be taken up mainly from the fellowing point of view. -low voltage and high current keeping up with the current demand for the latest telecommunication networks and broadband. -build-up of the total solution for dispersion system power supply. In this paper, an explanation is given to mainly concerning to the newest products in the supplier's position.

  • PDF

Improvement of Power Generation through Energy Harvesting Technology in Low Sunlight Section (낮은 일조량 구간에서 에너지 하베스팅 기술을 통한 발전량 향상)

  • Yoon, Yongho
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.22 no.3
    • /
    • pp.201-206
    • /
    • 2022
  • Energy harvesting is a concept introduced in 1954 by Bell Labs in the US while conducting research on solar cells that convert sunlight into energy. Such energy harvesting technology is a technology that collects wasted or unused energy in daily life and recycles it as electric power. In particular In the case of a photovoltaic power generation system, energy harvesting can be applied by storing electricity generated by using a battery to reduce power consumption generated by the inverter in the form of loss of power generation in cloudy weather compared to sunny days. Therefore, in this paper, energy harvesting technology is applied in the low sunlight section such as sunrise, sunset, and cloudy weather to improve the amount of power generation by recovering the power that is below the minimum operating voltage of the inverter and dissipated. Accordingly, the research contents were verified through the development of systems and algorithms according to the amount of solar power generation and the development of systems and algorithms using low power generated in sunset, sunrise, and other environments.

Study on the Variation of Reactive Power When Applying the Passive Filter (수동형 필터 적용시 무효전력의 변화에 관한 연구)

  • Kim, Ji-Myeong;Kim, Jong-Gyeum
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.9
    • /
    • pp.1626-1631
    • /
    • 2016
  • Generally, the low-voltage customer has been used with a linear load and nonlinear load in the 3-phase 4-wire distribution system. Linear load has usually configured the resistance and inductance, current phase is slower than the voltage phase, so power factor is low. It is required for the power factor correction device prior to the phase of the current than the voltage. The capacitor is connected in parallel to the load in order to ensure a low power factor. Power converter such as an inverter is a typical non-linear load. Non-linear load generates harmonic currents in the energy conversion process. Many electrical equipment may be adversely affected by the harmonic current. There, passive or active filter have been used to reduce these harmonics current. Passive filter consisting of inductor and capacitor generates a reactive power. According to the combination of filter inductor and capacitor, reactive power can be adjusted. In this paper, we analyzed how the combination of inductor and capacitor affects the overall power factor by simulation and measurement.

A Case Study on the Chungsong Pumped-storage power station Construction (청송 양수발전소 시공사례)

  • Hong, Chang-Soo;Lee, Hyun-Koo;Do, Jong-Youl
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.10a
    • /
    • pp.169-178
    • /
    • 2006
  • The pumped-storage power system is the one of the hydroelectric power systems, generating electricity with hydraulic head difference. In this system, the electricity is produced during the hours of peak demand by using water that has been pumped into an upper reservoir from a lower reservoir during the hours of low demand. Generally, the system consists of an under-ground power house and tunnels such as the headrace, pressure, and tailrace tunnels. The Chungsong pumped-storage power station is the sixth one In the pumped-storage power station in Korea. Both the regional self-government and the population of chungsong -Goon had made a great effort to draw this power station construction into this area. The proposed Chungsong pumped-power station construction project was accepted by the central government as a part of the national electricity plan for the first time in Korea.

  • PDF

A Class E Power Oscillator for 6.78-MHz Wireless Power Transfer System

  • Yang, Jong-Ryul
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.1
    • /
    • pp.220-225
    • /
    • 2018
  • A class E power oscillator is demonstrated for 6.78-MHz wireless power transfer system. The oscillator is designed with a class E power amplifier to use an LC feedback network with a high-Q inductor between the input and the output. Multiple capacitors are used to minimize the variation of the oscillation frequency by capacitance tolerance. The gate and drain bias voltages with opposite characteristics to make the frequency shift of the oscillator are connected in a resistance distribution circuit located at the output of the low drop-out regulator and supplied bias voltages for class E operation. The measured output of the class E power oscillator, realized using the co-simulation, shows 9.2 W transmitted power, 6.98 MHz frequency and 86.5% transmission efficiency at the condition with 20 V $V_{DS}$ and 2.4 V $V_{GS}$.

New MPPT Control Strategy for Two-Stage Grid-Connected Photovoltaic Power Conditioning System

  • Bae, Hyun-Su;Park, Joung-Hu;Cho, Bo-Hyung;Yu, Gwon-Jong
    • Journal of Power Electronics
    • /
    • v.7 no.2
    • /
    • pp.174-180
    • /
    • 2007
  • In this paper, a simple control method for two-stage utility grid-connected photovoltaic power conditioning systems (PCS) is proposed. This approach enables maximum power point (MPP) tracking control with post-stage inverter current information instead of calculating solar array power, which significantly simplifies the controller and the sensor. Furthermore, there is no feedback loop in the pre-stage converter to control the solar array voltage or current because the MPP tracker drives the converter switch duty cycle. This simple PCS control strategy can reduce the cost and size, and can be utilized with a low cost digital processor. For verification of the proposed control strategy, a 2.5kW two-stage photovoltaic grid-connected PCS hardware which consists of a boost converter cascaded with a single-phase inverter was built and tested.

Log Count Rate Circuits for Checking Electronic Cards in Low Frequency Band Reactor Power Monitoring (저주파수대의 원자로 출력신호 점검을 위한 대수 카운트레이트 회로)

  • Kim, Jong-ho;Che, Gyu-shik
    • Journal of Advanced Navigation Technology
    • /
    • v.24 no.6
    • /
    • pp.557-565
    • /
    • 2020
  • In order for thermal degradationIn, excore nuclear flux monitoring system, as a monitoring and signal processing methodology of reactor power, monitors neutron pulses generated during nuclear fission as frequency status, and converts them into DC voltage, and then log values resultantly. The methods realy applied in the nuclear power plant are to construct combination of counters and flip-flops, or diodes and capacitors up to now. These methodes are reliable for relative high frequencies, while not credible for reasonable low frequencies or extreme low values. Therefore, we developed the circuit that converts frequencies into DC voltages, into and into log DC values in the wide range from low Hz to several hundred high kHz. We proved their validities through testing them using real data used in nuclear power plant and analyzed their results. And, these methods will be used to measure the neutron level of excore nuclear flux monitoring system in nuclear power plant.

Wake-Up Receiver System Design Using the DGS Rectenna (DGS Rectenna를 이용한 Wake-Up 수신기 시스템 설계)

  • Choi, Tae-Min;Lee, Seok-Jae;Lee, Hee-Jong;Lim, Jong-Sik;Ahn, Dal;Han, Sang-Min
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.3
    • /
    • pp.377-383
    • /
    • 2012
  • In this paper, a new design of a planar rectenna system and its application to a wake-up receiver operating for incoming signal with a specified frequency are proposed for low-power sensor system applications. The planar and integrable rectenna system is designed with DGSs(Defected Ground Structures) at 2.4 GHz. The DGSs reject harmonic components of 4.8 and 7.2 GHz and eliminate 2.4 GHz fundamental frequency for DC-path filtering. The rectenna system has been evaluated for the conversion output voltages, and applied to the switching of a power supply at the low-power sensor receivers. The proposed system has been evaluated for the wake-up performance by testing a lownoise amplifier operation. From the experimental results, the proposed receiver system presents excellent operation performances.

Implementation of Self Diagnostics Low-power Embedded Linux System using Telematics (텔레매틱스을 통한 자가진단 저전력 임베디드 리눅스 시스템 구현)

  • Ju, Jae-han
    • Journal of Advanced Navigation Technology
    • /
    • v.21 no.3
    • /
    • pp.300-305
    • /
    • 2017
  • It is necessary to establish a system suitable for the driving vehicle so that it can effectively search for and modify various data anywhere and anytime by effectively linking communication with the computer system in the running vehicle and to control the equipment properly for smooth operation on a limited platform do. Also, vehicle CAN communication is used to extract system engine information, and data is transmitted using ZigBee for this information transmission. Therefore, OBD-II protocol, which is provided by the vehicle itself, is used for vehicle CAN to obtain vehicle status information and exhaust gas using various sensor information of the vehicle and O2 sensor value, and transmits it to the ZigBee main control system. In this study, we implemented a system that can reduce the battery load damage to the maximum by reducing the power consumption to the maximum, and to monitor the internal state of the vehicle through ZigBee communication with the embedded system for low power vehicles.