• Title/Summary/Keyword: Low-noise housing

Search Result 56, Processing Time 0.029 seconds

A Study on the Squeal Noise Instability Analysis on Caliper Brake (캘리퍼 브레이크 스퀼 소음의 불안정성 해석에 관한 연구)

  • Lee, Junghwan;Kim, Seonghwan
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.11
    • /
    • pp.957-965
    • /
    • 2013
  • This paper deals with analytical methods for low frequency and high frequency brake squeal noise on brake-rear caliper. In order to improve low frequency and high frequency squeal noise, we take survey caliper bracket shape parameters and housing shape parameters. Besides, using the combination of bracket and housing parameter were surveyed. Thus, using the combination of bracket Alt_05 and housing Alt_45 specifications, instability analysis and brake dynamo test were carried out. Based upon the two models, low and high frequency squeal noise of base model were improved. But, for 6.0 kHz frequency noise, which is not improved, it needs to additionally study on instability analysis and combination of the other brake components.

A Case Study on Noise Reduction Effect of Two-layer Porous Asphalt Pavement in an Urban Area (도심지 내 복층 저소음포장 설치에 따른 소음저감 사례연구)

  • Jung, Jong-Seo;Sohn, Jeong-Rak;Lee, Soo-Hyoung;Yang, Hong-Seok
    • International Journal of Highway Engineering
    • /
    • v.18 no.5
    • /
    • pp.49-56
    • /
    • 2016
  • PURPOSES : In this study, noise reduction effect of a two-layer porous asphalt pavement was investigated through site measurement and computer simulation. METHODS : To examine noise reduction effect, a 3 km long quiet pavement was installed by removing previous normal pavement, which had a rather low porosity. The studied site was a high-rise apartment building surrounded by the quiet pavement and Seoul ring road with heavy traffic volume, indicating relatively high background noise. RESULTS : The measurement result before and after installing the quiet pavement showed a noise reduction effect of 4.3 dB(A) at a distance of 7.5 m from the road. After validating the accuracy of simulation using SoundPLAN, the reduction in SPL(sound pressure level) at the facades by the quiet pavement was predicted by considering five different road conditions generating traffic noise from each road or in the combination of the quiet pavement and Seoul ring road. In the case of no noise from Seoul ring road, noise reduction at the facades was 4.2 dB(A) on average for 702 housing units. With background noise from Seoul ring road, however, the average SPL decreased to 2.0 dB(A). Regarding subjective response of noise, the number of housing units with a noise reduction of over 3 dB(A) was 229 out of 706 units (approximately 32%). For 77 housing units, the noise reduction was between 1~3 dB(A), while it was less than 1 dB(A) for 400 housing units. CONCLUSIONS : The overall result indicates that the quiet pavement is useful to reduce noise evenly at low and high floors compared to noise barriers, especially in the urban situation where background noise is low.

A Study on the Structure Improvement of Bracket Housing for Structural Noise and Vibration Reduction in Hydraulic Breaker (유압 브레이커의 구조 소음.진동 저감을 위한 브래킷 하우징의 구조 개선에 관한 연구)

  • Kim, Bong-Suk;Kim, Min-Gi;Byun, Dong-Woo;Lee, Seong-Min;Lee, Soo-Hun
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.23 no.11 s.188
    • /
    • pp.108-115
    • /
    • 2006
  • A hydraulic breaker is widely utilized for many civil engineering areas for the purpose of destroying objects such as rocks, concrete, or road. However, since the high-level noise and vibration by a hydraulic breaker is one of the major sources of environmental noise and recently the environmental regulations on construction equipments are also getting more strengthened, in order to solve such problems, it is certainly necessary to design and develop a hydraulic breaker with low noise and low vibration. This research is to understand the noise characteristics through the noise test and acoustic analysis of the bracket housing in a hydraulic breaker and to identify the element part to be modified based on the result of the element contribution analysis. An improved breaker model including X-typed rib shows the result of low-noise level within target frequency band compared with a commercial breaker model.

Prediction of Noise & Vibration Effect of Agricultural Tractor Transmission at Design Stage

  • Kim, Jung-Hun;Kang, Young-Sun
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1996.06c
    • /
    • pp.354-358
    • /
    • 1996
  • At design stage of the TRXI agricultural tractor transmission (New product of TongYang Moolsan Co., Ltd), the noise and vibration of the transmission were analyzed theoretically for the optimal design of the transmission . For this analysis, the finite element model was developed using a commercial computer software, ANSYS. The noise and vibration of the TRXI transmission housing were predicted by the modal analysis. Natural frequency of the TRXI transmission housing was ranged from 12.53Hz(1st mode ) to 30.05Hz(5th mode). The fifth mode took place at the bearing metal in the area of rear transmission housing and was very close to the gear mesh frequency (30.5Hz) of low rang gear at the low creep shifting . Based on the results , the bearing metal of the range shift housing was reenforced with the rib at design stage.

  • PDF

A Study on the Quality Improvement of Housing Environment in Low-Income Families of Daejeon Area (대전지역 저소득층 주거환경의 질적인 개선에 관한 연구)

  • 이정희
    • Journal of the Korean Home Economics Association
    • /
    • v.28 no.2
    • /
    • pp.57-72
    • /
    • 1990
  • The purpose of this study were ; (1) to analyze the relationship between actual housing condition and housing satisfaction with socio-demographic and housing characteristics of respondents and (2) to present the device on the quality of housing environment in low-income families. The sample was a proportional, stratified, random sample of 299 low-income families in Deajeon. The major findings were as follows: 1) The wholey, actual housing conditions were not good; especially the worst conditions appeared exterior walls, roof, kitchen, bath and toilet, heating, noise, recreation facilities as play-ground. 2) Actual housing condition has been found to be related to income, tenure(rent or own), persons/room. In the relation of the socio-demographic and housing characteristics, actual housing condition, housing satisfaction, income and persons/room were found to be a significant explanatory variable in actual housing condition. And actual housing condition ws appeared to be the strongest variable in housing satisfaction. 3) Housing of the low-income families should be improved physical aspects of the environment and be reflected in need of the occupant that based on the social-welfare housing concept.

  • PDF

Noise Identification and Control of 2-Pole Squirrel Cage Motor for Industrial Compressor (2극 컴프레셔용 전동기의 소음특성 규명 및 저감)

  • 주원호;임종욱;김동해
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.709-712
    • /
    • 2003
  • Recently, high noise problem was experienced during the development of 2-pole squirrel cage motor for industrial compressor. In order to firstly identify the noise characteristics, a variety of measurements were carried out. It was found out that high noise was dominated by linear and nonlinear slot noise components. For the development of low noise indusrial motor, the air gap between rotor and stator in the motor was firstly enlarged. Secondly, it was also modified for the cooling housing to have high absorption features. Consequencely, low noise 2-pole motor having the noise level of less 80㏈(A) was developed. In this paper, a series of noise identification and control process for this motor are introduced.

  • PDF

Empirical Analysis of Airplane Route for Reduction of Aircraft Noise at Gimhae International Airport (김해국제공항 항공기 소음 저감을 위한 비행기항적실증분석)

  • Kim, Bong-Ki;Lee, Seung-Won
    • Journal of Environmental Science International
    • /
    • v.30 no.3
    • /
    • pp.257-266
    • /
    • 2021
  • This study explored measures to reduce noise applicable to Gimhae international airport centering on densely packed housing areas. Especially, as for measures to relieve noise damage on the densely packed housing areas in Gimhae-si, the noise reduction effect is expected to be doubled if the west runway (36L/18R) is used as the preferred runway for the 36 direction takeoff, as well as if the flight bypasses the densely packed housing areas by means of sophisticated navigation using the area navigation (RNAV) procedure based on performance-based navigation (PBN). Takeoff toward the south connects the flight path to the South Sea which has comparatively low noise impact, relieving noise damage on the densely packed housing areas (apartment complexes in Naeoe-dong of Gimhae-si, etc.) near the northern end of the runway. The operation of the runway displaced threshold is currently being implemented on the west runway (36L/18R) of Gimhae international airport. It has been found that swing landing in spring and summer when the wind blows from the south has a noise reduction effect on the noise sensitive areas at the side and end of the west runway (Gangdong-dong and Jukdong-dong of Gangseo-gu and Buram-dong of Gimhae-si, etc.).

A Study on the Interregional Relationship of Housing Purchase Price Volatility (지역간 주택매매가격 변동성의 상관관계에 관한 연구)

  • Yoo, Han-Soo
    • Korean Business Review
    • /
    • v.20 no.2
    • /
    • pp.15-27
    • /
    • 2007
  • This paper analyzed the relationship between Housing Purchase Price volatility of Seoul and Housing Purchase Price volatility of local large city. Other studies investigates the effect on the observed volatility Observed volatility consists of fundamental volatility and transitory volatility. Fundamental volatility is caused by information arrival and transitory volatility is caused by noise trading. Fundamental volatility is trend component and is modelled as a random walk with drift. Transitory volatility is cyclical component and is modelled as a stationary process. In contrast to other studies, this study investigates the effect on the fundamental volatility and transitory volatility individually. Observed volatility is estimated by GJR GARCH(1,1) model. We find that GJH GARCH model is superior to GARCH model and good news is more remarkable effect on volatility than bad news. This study decomposes the observed volatility into fundamental volatility and transitory volatility using Kalman filtering method. The findings in this paper is as follows. The correlation between Seoul housing price volatility and Busan housing price volatility is high. But, the correlation between Seoul and Daejeon is low. And the correlation between Daejeon and Busan is low. As a distinguishing feature, the correlation between fundamental volatilities is high in the case of all pairs. But, the correlation between transitory volatilities turns out low. The reason is as follows. When economic information arrives, Seoul, Daejeon, and Busan housing markets, all together, are affected by this information.

  • PDF

The Evaluation on the Noise Environment of the Low-rise Multi-family house in Athens,U,S,A (미국 Athens 지역 저층 공동주택 소음 환경평가에 관한 연구)

  • 곽경숙
    • Journal of the Korean housing association
    • /
    • v.11 no.4
    • /
    • pp.85-96
    • /
    • 2000
  • The purpose of this study was to evaluated noise environment of the low-rise multi-family house in Athens, Georgia. The results of this study can be applied to the prevention of noise when planning multi-family houses, roads and cities in Korea. The subjects of this study were the place of 1m, 10m, 50m, 100m from 4-lane road ofT apartment and 233 residents lived in the low-rise multi-family houses in Athens. The results of this study were as follows. 1. The average noise level at 1m, 10m, 50m and 100m was 55.5dB, 46.7dB, 43.0dB, 43.0dB and 41.2dB respectively from 4-lane road of T apartment. From the view of the standard in this study, the physical noise was good. 2. The results of the residents subjective response on the noise were as follows. The external noise residents felt - that was a noise by operating machines, and traffic noise - ware as 2.57 on average. The noise by the daily activities, the noise of nature are a little as 2.38 on average. They were disturbed a little by the external noise. They felt the solid born sounds(average 2.49) more than airbone sound(average 2.23) by the internal noise. They are suffered worse from noise in summer and they worse from 8-12 oclock due to external noise and 16-20 oclock due to internal noise. Comparing the noise environment of Korean with that of American, I found a meaningful difference of nature and the noise of daily activities of external noise and all internal noise.

  • PDF

A Development of an Intake RCV System for the Low Noise Turbo Engine (터보엔진의 저소음 흡기 RCV 시스템 개발)

  • Lee, Jong-Kyu;Kim, Jae-Heon;Kang, Sang-Kyu;Kang, Koo-Tae
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.20 no.8
    • /
    • pp.734-741
    • /
    • 2010
  • In this paper, an intake RCV system for low noise turbo engine was developed through optimization process of a geometric path of compressor housing and an open rate of recirculation valve. At first, the critical customer requirement from voice of customer was defined and quality function deployment of an intake RCV system was executed. And then, the renovative concept design using pugh matrix method was selected as final concept for satisfaction of requirement. Simultaneously, system analysis was carried by function diagram and fishbone diagram. Next, control factors and levels for the optimal design were performed. And, the optimal design of an intake RCV system was studied using design of experiment. Conclusively, we achieved not only cancellation tip-out noise at the driving condition but also improvement of NVH commodity through optimization process of an intake RCV system, which is optimal configuration of compressor housing and recirculation valve.