• Title/Summary/Keyword: Low-frequency range

Search Result 1,815, Processing Time 0.029 seconds

A Laboratory Study on Low Frequency Noise Assessment based on Noise Acceptability Limits (소음 수응 한계(Noise Acceptability Limits)를 고려한 저주파 소음평가에 대한 실험적 연구)

  • Hong, Seung-Ki;Kim, Jae-Hwan;Kim, Kyu-Tae;Lee, Soo-Gab
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.127-131
    • /
    • 2007
  • A laboratory study on low frequency noise assessment was carried out to determine the acceptability limits in the frequency range between 20 and 200 Hz. The acceptability limits were tested in the anechoic chamber to minimize the background noise. A total of 30 test subjects, who were aged between 19 to 33 years, participated in this study. They were exposed to various stimuli for about 1 hour by supra-aural earphone. The experiment consisted of two listening sessions; hearing threshold and the acceptability limits session. The results showed that the trend of the acceptability limits curve was approximately equal to C-weighting curve which had been found to be superior to A-weighting curve in low frequency noise assessment.

  • PDF

Measurement of Dispersion Relation of Plasma Wave (플라즈마 파동의 분산관계 측정에 관한 연구)

  • Jeong, Jung-Hyeon;Lee, Jong-Gyu
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.33 no.3
    • /
    • pp.248-258
    • /
    • 1997
  • The analytical solutions of the Fraunhofer Diffraction(FD) theory and the principle for measurement of the dispersion relation of plasma wave is presented. Especially, the method for measurement of low-frequency wave is discussed. The wavenumbers of the density fluctuations are obtained from the curve fitting between the expremental FD profile and theoretical one for each frequency component. In measurement of the wavenumber of the low -frequency region, the information of the wavenumber is easily obtained from the ratio of the intensity at = 0 to the intensity at =0.5. The millimeter wave FD apparatus was designed to measure low-frequency density fluctuations. The determined wavenumbers are in the range of =0.1~ 1.0cm. Thus, the millimeter wave FD method was shown to be useful for the measurement of low-frequency density fluctuations, which are impossible to be measured by using a convention. Thomson scattering. The obtained dispersion relations will be useful information for plasma waves.

  • PDF

Investigation of Low-Frequency Characteristics of Four-Switch Three-Phase Inverter

  • Yuan, Qingwei;Cheng, Chong;Zhao, Rongxiang
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.4
    • /
    • pp.1471-1483
    • /
    • 2017
  • The low-frequency characteristics of four-switch three-phase (FSTP) inverter are investigated in this paper. Firstly, a general space vector pulse width modulation (SVPWM) directly involved the neutral point voltage of DC-link is proposed, where no sector identifications and trigonometric function calculations are needed. Subsequently, to suppress the DC offset in the neutral point voltage, the relationship between the neutral point voltage and the ${\beta}-axis$ component of the load current is derived, and then a new neutral point voltage control scheme is proposed where no low pass filter is adopted. Finally, the relationship between the load power factor and the maximum linear modulation index of the FSTP inverter is revealed. Since the operational region for the FSTP inverter in low frequency is reduced by the enlarged amplitude of the neutral point voltage, a linear modulation range enlargement scheme is proposed. A permanent magnet synchronous motor with preset rotary speed serves as the low-frequency load of the FSTP inverter. Experimental results verify that the new neutral point voltage control scheme is effective in the deviation suppression of the neutral point voltage, and the proposed scheme is able to provide a larger linear operational region in low frequency.

Design and Implementation of Medical Compound Stimulator Using Low/High Frequency and Cooling Stimulation (저주파/고주파와 냉자극을 이용한 의료용 조합 자극기의 설계 및 구현)

  • Yoon, Wan-Oh;Kang, Suk-Youb;Jung, Jin-Ha;Choi, Sang-Bang
    • Journal of Biomedical Engineering Research
    • /
    • v.29 no.1
    • /
    • pp.82-87
    • /
    • 2008
  • In this paper, the study was carried out to design and implement the medical compound stimulator based on the preexisting individual medical stimulators with Low frequency, High frequency and cooling stimulation. The proposed equipment is designed to compound all the functions including a cooling stimulation with a range of $0{\sim}20^{\circ}C$ and the verified low and high frequencies of 250Hz, 500Hz, 1KHz and 1MHz respectively from the previous clinical experiment with a consideration of its credibility and efficiency. Also, it was constructed by using a new technique, thermoelectricity semiconductor with a consideration of miniaturization and stability. In accordance with patients' treatment purpose, the hand piece of low frequency/cooling stimulation and High frequency/cooling stimulation were separately designed for convenience. The frequency, accuracy and other factors of implemented medical compound stimulator was satisfied according to its measurement. It was also tested by Korean Testing Laboratory (KTL) for its stability and efficacy and it confirmed that the medical compound stimulator is suitable for use as it fits in with the medical equipment standards.

An Experimental Study on the Absorption Property of Slit Absorbers with Composite Details

  • Jeong, Dae-Up;Joo, Moon-Ki
    • The Journal of the Acoustical Society of Korea
    • /
    • v.21 no.2E
    • /
    • pp.81-90
    • /
    • 2002
  • Single absorbing materials and Helmholtz resonators have limited absorption characteristics over limited frequency ranges due to their structures and properties. Porous materials are highly absorptive for mid and high frequency ranges, while they have little sound absorption for low frequency sounds. Helmholtz resonators are generally used to absorb sound energy for a specified frequency range. Hence they have limited capability in controlling the overall acoustic properties of a space. Not much has been known about useful finishing materials which have enough rigidity and absorption over broad frequency range, in spite of wide demands from acoustic designers and consultants. The present work measured and analyzed absorption characteristics of a slit absorber by varying surface materials, depths of air gap, dimensions of slat and slit widths. It was found that the narrower the slit width, the larger the absorptions over the wide frequency ranges and the pattern was dependent on the presence of porous material. Narrower slat's width tend to increase the slit absorber's absorption more or less. Absorption coefficients at low frequency ranges were dramatically improved (from 0.23 to 0.56) by increasing air gap when porous materials were present.

Influence of a Warm Eddy on Low-frequency Sound Propagation in the East Sea (동해에서 저주파 음파전파에 미치는 난수성 소용돌이의 영향)

  • Kim, Bong-Chae;Choi, Bok-Kyoung;Kim, Byoung-Nam
    • Ocean and Polar Research
    • /
    • v.34 no.3
    • /
    • pp.325-335
    • /
    • 2012
  • It is well known that sound waves in the sea propagates under the influence of sea surface and bottom roughness, the sound speed profile, the water depth, and the density of sea floor sediment. In particular, an abrupt change of sound speed with depth can greatly affect sound propagation through an eddy. Eddies are frequently generated in the East Sea near the Korean Peninsula. A warm eddy with diameter of about 150 km is often observed, and the sound speed profile is greatly changed within about 400 m of water depth at the center by the eddy around the Ulleung Basin in the East Sea. The characteristics of low-frequency sound propagation across a warm eddy are investigated by a sound propagation model in order to understand the influence of warm eddies. The acoustic rays and propagation losses are calculated by a range-dependent acoustic model in conditions where the eddy is both present and absent. We found that low-frequency sound propagation is affected by the warm eddy, and that the phenomena dominate the upper ocean within 800 m of water depth. The propagation losses of a 100 Hz frequency are variable within ${\pm}15$ dB with depth and range by the warm eddy. Such variations are more pronounced at the deep source near the sound channel axis than the shallow source. Furthermore, low-frequency sound propagation from the eddy center to the eddy edge is more affected by the warm eddy than sound propagation from the eddy edge to the eddy center.

Effects of the Vestibular Caloric Stimulation with Ice Water on the Autonomic Nervous System

  • Kim, Chungyoo;Kang, Jongho
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.4 no.3
    • /
    • pp.27-30
    • /
    • 2016
  • PURPOSE : The effect of the vestibular caloric stimulation with ice water on the autonomic nervous system was investigated using pulse oximetry. METHOD : Thirty-four healthy men and women were subject to a 2-minute vestibular caloric stimulation with ice water, and autonomic nervous activities (low frequency, high frequency, and total power) were measured before and after the vestibular caloric stimulation. Data were analyzed separately for men and women. RESULT : Low frequency, high frequency, and total power in the men and low frequency in the women were statistically significantly higher after vestibular caloric stimulation. High frequency and total power in the women were higher but not significantly different after vestibular caloric stimulation. CONCLUSION : Vestibular caloric stimulation with ice water increases autonomic nervous activities, with the variation being within the normal range. The test can be considered safe for use.

Anechoic Chamber Design using Broadband Compact Absorber (패널형 흡음재를 이용한 무향실의 설계)

  • ;;Peter Brandstatt;Helmut V. Fuchs
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.393-396
    • /
    • 2003
  • Conventional method for designing and installing anechoic chambers is to utilize porous wedges for the sound absorbers. As cutoff frequency lowers down such as 63Hz or 50Hz, the corresponding long wedges diminish the free field area of the chamber. In this study, a new broadband compact absorber(BCA) is introduced which absorbs acoustic energy down to 50Hz. Most prominent is that it measures only 250mm thick. A freely vibrating panel between the non-fibrous absorbers allows tuned absorption at the low frequency region in addition to the high frequency absorption resulted from the conventional absorber installed at the front. Standing waves at low frequency range are suppressed as the BCA modules which are tuned to the corresponding modes absorb sound energy effectively, resulting in anechoic condition. Not only the low frequency performances, but the high frequency absorption is measured to meet adequate conditions for the anechoic chamber. Realized BCA chambers are presented.

  • PDF

Magnetoelectric Characteristics on Layered Ni-PZT-Ni, Co, Fe Composites for Magnetic Field Sensor (자기센서용 Ni-PZT-Ni, Co, Fe 적층구조 소자의 ME 특성)

  • Ryu, Ji-Goo;Jeon, Seong-Jeub
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.28 no.2
    • /
    • pp.92-98
    • /
    • 2015
  • The magnetoelectric characteristics on layered Ni-PZT-Ni, Co, Fe composites by epoxy bonding for magnetic field sensor were investigated in the low-frequency range. The ME coefficient of Ni-PZT-Ni, Ni-PZT-Co and Ni-PZT-Fe composites reaches a maximum of $200mV/cm{\cdot}Oe$ at $H_{dc}=110$ Oe, $106mV/cm{\cdot}Oe$ at $H_{dc}=90$ Oe and $87mV/cm{\cdot}Oe$ at $H_{dc}=160$ Oe, respectively. A trend of ME charateristics on Ni-PZT-Co, Ni-PZT-Fe composites was similar to that of Ni-PZT-Ni composites. The ME output voltage shows linearly proportional to ac field $H_{ac}$ and is about 0~150 mV at $H_{ac}$=0~7 Oe and f=110 Hz in the typical Ni-PZT-Ni sample. The frequency shift effect due to the load resistance $R_L$ shows that the frequency range for magnetic field sensor application can be modulated with appropriate load resistance $R_L$. This sample will allow for a low-magnetic ac field sensor in the low-frequency (near f=110 Hz).

Dielectric loss of silicone oils for insulation due to the increase of viscosity (점도증가에 따른 절연용 실리콘유의 유전손실)

  • 이용우;조경순;김왕곤;홍진웅
    • Electrical & Electronic Materials
    • /
    • v.8 no.5
    • /
    • pp.587-593
    • /
    • 1995
  • Silicone oils used insulating substances exhibit the both of organic and inorganic properties, and it has many superior characteristics such as the high thermal resistance and low thermal oxidation level when compared to other insulation oils. In order to investigate the dielectric loss due to the increase of viscosity, silicone oils of viscosity 1, 2, 5[cSt] had been chosen as the specimen and experiment has been performed in the temperature range of -70[.deg. C] - 65[.deg. C] and frequency range of 30 - 1*10$\^$5/[Hz]. As a result, the linear decrease of loss at low frequency region in high temperature was due to the influence of applying frequency, whereas the increase of loss at high frequency region was contributed by electrode's resistance. And increasing viscosity, the activation energy increased from 3.77[kcal/mole] to 7.21[kcal/mole]. The dipole moment of specimen was become clear 1.48 - 2.26[debyel in high temperature region(5 - 65[.deg. C]) and 1.05 - 1.80[debye] in low temperature region (-70 - -25[.deg. C])respectively.

  • PDF