• 제목/요약/키워드: Low-flow

검색결과 6,290건 처리시간 0.036초

말더듬에서 언제 보툴리늄독소주입술이 효과적인가에 관한 연구 (When the Botulinium Toxin Injection Is Effective in Stutters)

  • 안철민
    • 대한후두음성언어의학회지
    • /
    • 제26권1호
    • /
    • pp.46-50
    • /
    • 2015
  • Background and Objectives:Laryngeal hyperkinetic movements of stuttering patients is similar to that of adductor spasmodic dysphonia. There has been studies on implementing botulinium toxin injections to treat stuttering. However, the opinions on the bouolinium toxin injection's effects on stuttering patients vary. In this study authors aim to figure out when the botulinium toxin injection improves stuttering patients. Materials and Methods:Stuttering patients who could receive botulinium toxin injection participated in this study. Age differences, gender differences, electroglottogrphic test, aerodynamic test in botulinium toxin injection treatment of stuttering were analyzed. Results:The botulinium toxin injection had statistically significant impact on patients who showed low mean air flow rate during aerodynamic study. Conclusion:The botulinium toxin injection could reduce stuttering of patients with low mean air flow rate in aerodynamic study.

  • PDF

SiOC 절연박막 특성에 의존하는 ITO 투명박막의 전기적인 특성과 오믹접합의 효과 (Ohmic Contact Effect and Electrical Characteristics of ITO Thin Film Depending on SiOC Insulator)

  • 오데레사
    • 한국재료학회지
    • /
    • 제25권7호
    • /
    • pp.352-357
    • /
    • 2015
  • To research the characteristics of ITO film depending on a polarity of SiOC, specimens of ITO/SiOC/glass with metal-insulator-substrates (MIS) were prepared using a sputtering system. SiOC film with 17 sccm of oxygen flow rate became a non-polarity with low surface energy. The PL spectra of the ITO films deposited with various argon flow rates on SiOC film as non-polarity were found to lead to similar formations. However, the PL spectra of ITO deposited with various argon flow rates on SiOC with polarity were seen to have various features owing to the chemical reaction between ITO and the polar sites of SiOC. Most ITO/SiOC films non-linearly showed the Schottky contacts and current increased. But the ITO/SiOC film with a low current demonstrated an Ohmic contact.

섭동법을 이용한 만곡 리뷸릿에 관한 이론적 연구 (Perturbation Analysis of a Meandering Rivulet)

  • 김진호;김호영;강병하;이재헌
    • 설비공학논문집
    • /
    • 제13권12호
    • /
    • pp.1196-1204
    • /
    • 2001
  • The rivulet is a narrow stream of liquid flowing down a solid surface. When the rivulet\`s flow rate exceeds a certain limit, it tends to meander exhibiting the instability of its interface. This analysis performs a perturbation analysis of this meandering rivulet assuming an inviscid flow possessing contact angle hysteresis at the contact line. The analysis reveals that the contact angle hysteresis as well as the velocity difference across the inter-face, strongly induces the instability of the liquid interface. Moreover, when the rivulet veto-city is low, it is predicted that the axisymmetric disturbance amplifies more rapidly than the anti-axisymmetric disturbance, which explains the emergence of the droplet flow at the low velocity regime.

  • PDF

Convection in the growth of zinc telluride single crystal by physical vapor transport

  • Kim, Geug-Tae
    • 한국결정성장학회지
    • /
    • 제13권4호
    • /
    • pp.187-198
    • /
    • 2003
  • Zinc selenide (ZnSe) single crystals hold promise for many electro-optics, acousto-optic and green laser generation applications. This material is prepared in closed ampoules by the physical vapor transport (PVT) growth method based on the dissociative sublimation. We investigate the effects of diffusive-convection on the crystal growth rate of ZnSe with a low vapor pressure system in a horizontal configuration. Our results show that for the ratios of partial pressures, s=0.2 and 2.9, the growth rate increases with the Peclet number and the temperature differences between the source and crystal. As the ratio of partial pressures approaches the stoichiometric value of 2, the rate increases. The mass fluk based on one dimensional (1D model) flow for low vapor pressure system fall within the range of the predictions (2D model) obtained by solving the coupled set of conservation equations, which indicates the flow fields would be advective-diffusive. Therefore, the rate and the flow fields are independent of gravity acceleration levels.

유기랭킨사이클과 암모니아-물 랭킨사이클의 열역학적 성능의 비교 해석 (Comparative Thermodynamic Analysis of Organic Rankine Cycle and Ammonia-Water Rankine Cycle)

  • 김경훈;김만회
    • 한국수소및신에너지학회논문집
    • /
    • 제27권5호
    • /
    • pp.597-603
    • /
    • 2016
  • In this paper a comparative thermodynamics analysis is carried out for organic Rankine cycle (ORC) and ammonia-water Rankine cycle (AWRC) utilizing low-grade heat sources. Effects of the working fluid, ammonia concentration, and turbine inlet pressure are systematically investigated on the system performance such as mass flow rate, pressure ratio, turbine-exit volume flow, and net power production as well as the thermal efficiency. Results show that ORC with a proper working fluid shows higher thermal efficiency than AWRC, however, AWRC shows lower mass flow rate of working fluid and lower pressure ratio of expander than ORC.

부력 효과의 최소화를 통한 대향류 확산화염 소화거동에 관한 실험적 연구 (Experimental Study on Extinction Behavior in Buoyancy-minimized Counterflow Diffusion Flame)

  • 정용호;박정;권오붕;윤진한;길상인;김영주
    • 한국연소학회지
    • /
    • 제17권4호
    • /
    • pp.38-43
    • /
    • 2012
  • Experimental study was conducted to elucidate flame extinction phenomena in counterflow flame. Using a curtain helium flow significantly reduced buoyancy such that the flame can be positioned at the center between the upper and lower nozzles even at the velocity ratio of 1.0. The curves of critical diluent mole fraction versus global strain rate have C-shapes. The flame oscillation was observed prior to low strain rate flame extinction at both flame conditions with and without minimizing buoyancy force. The results show that, at low strain rate flame, the self-excitation frequency with the order of 1.0 Hz in the case of utilizing pure helium gradually decreases in increase of $N_2$ mole fraction in the curtain flow, meaning that buoyancy suppresses the self-excitation of the outer edge flame.

저조도 환경 감시 영상에서 시공간 패치 프레임을 이용한 이상행동 분류 (Spatiotemporal Patched Frames for Human Abnormal Behavior Classification in Low-Light Environment)

  • ;공성곤
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2023년도 추계학술발표대회
    • /
    • pp.634-636
    • /
    • 2023
  • Surveillance systems play a pivotal role in ensuring the safety and security of various environments, including public spaces, critical infrastructure, and private properties. However, detecting abnormal human behavior in lowlight conditions is a critical yet challenging task due to the inherent limitations of visual data acquisition in such scenarios. This paper introduces a spatiotemporal framework designed to address the unique challenges posed by low-light environments, enhancing the accuracy and efficiency of human abnormality detection in surveillance camera systems. We proposed the pre-processing using lightweight exposure correction, patched frames pose estimation, and optical flow to extract the human behavior flow through t-seconds of frames. After that, we train the estimated-action-flow into autoencoder for abnormal behavior classification to get normal loss as metrics decision for normal/abnormal behavior.

Breast Ultrasound Microvascular Imaging and Radiogenomics

  • Ah Young Park;Bo Kyoung Seo;Mi-Ryung Han
    • Korean Journal of Radiology
    • /
    • 제22권5호
    • /
    • pp.677-687
    • /
    • 2021
  • Microvascular ultrasound (US) techniques are advanced Doppler techniques that provide high sensitivity and spatial resolution for detailed visualization of low-flow vessels. Microvascular US imaging can be applied to breast lesion evaluation with or without US contrast agents. Microvascular US imaging without a contrast agent uses a sophisticated wall filtering system to selectively obtain low-flow Doppler signals from overlapped artifacts. Microvascular US imaging with second-generation contrast agents amplifies flow signals and makes them last longer, which facilitates hemodynamic evaluation of breast lesions. In this review article, we will introduce various microvascular US techniques, explain their clinical applications in breast cancer diagnosis and radiologic-histopathologic correlation, and provide a summary of a recent radiogenomic study using microvascular US.

혼류 펌프의 성능 해석 (Performance prediction of mixed-flow pumps)

  • 오형우;윤의수;정명균;하진수
    • 대한기계학회논문집B
    • /
    • 제22권1호
    • /
    • pp.70-78
    • /
    • 1998
  • The present study has tested semi-empirical loss models for a reliable performance prediction of mixed-flow pumps with four different specific speeds. In order to improve the predictive capabilities, this paper recommends a new internal loss model and a modified parasitic loss model. The prediction method presented here is also compared with that based on two-dimensional cascade theory. Predicted performance curves by the proposed set of loss models agree fairly well with experimental data for a variety of mixed-flow pumps in the normal operating range, but further studies considering 'droop-like' head performance characteristic due to flow reversal in mixed-flow impellers at low flow range near shut-off head are needed.

설계인자 변경에 따른 버터플라이 밸브 유동 특성에 관한 연구 (CHARACTERISTIC OF BUTTERFLY VALVE FLOW WITH DIFFERENT DESIGN FACTORS)

  • 이종욱;최훈기;유근종
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2009년 추계학술대회논문집
    • /
    • pp.170-176
    • /
    • 2009
  • Flow control butterfly valve(FCBV) is known to have difficulty in controlling flow rate along valve opening due to its high flow rate. In low opening condition, the butterfly valve also has some shortcomings such as noise, vibration and erosion which are mostly caused by cavitation effects. Therefore, the FCBV requires proper remedies to reduce cavitation effects and to improve flow control performance. Numerical analysis is applied to FCBV flow to find effects of design factors such as seat diameter and valve opening rate. Cases with 3 different sizes of seat diameter and various valve opening rate are selected for the numerical analysis. From the analysis results, it is found that the FCBV with small seat diameter shows better pressure loss performance and reduced cavitation effects.

  • PDF