• Title/Summary/Keyword: Low-flow

Search Result 6,290, Processing Time 0.039 seconds

Flow inside the Droplet in AC Electrowetting (AC 전기습윤에서 액적 내부의 유동)

  • Ko, Sung-Hee;Kang, Kwan-Hyoung
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2995-2996
    • /
    • 2007
  • We found that there exists a flow inside a droplet in AC electrowetting, which is distinct from DC electrowetting. In order to investigate the origin of the flow inside the droplet, we performed an experiment and numerical simulation. It is conjecture, based on the results of the experiment and numerical simulation, the flow is caused by the so called induced-charge electroosmosis at high frequencies, and by droplet oscillation at low frequencies.

  • PDF

Measurement of optical flow using horn and anandan techniques (Horn과 Anandan기법을 이용한 Optical flow 측정)

  • 송석진;남기곤;이장명
    • Proceedings of the IEEK Conference
    • /
    • 1998.06a
    • /
    • pp.685-688
    • /
    • 1998
  • Measurement of optical flow is a core problem of matching through the analysis of image sequences. In this paper, horn's and anandan's techniques are analyzed to derive a better technique for matching. Experimental results show that Horn's technique has low accuracy in measuring the velocity of optical flow while anandan's technique has poor performaance for diverging images. Based upon this observation, a new technique for the measurement of optical flow is proposed.

  • PDF

A Preconditioning Method for Two-Phase Flows with Cavitation

  • Shin B.R.;Yamamoto S.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.181-182
    • /
    • 2003
  • A preconditioned numerical method for gas-liquid to-phase flow is applied to solve cavitating flow. The present method employs a density based finite-difference method of dual time-stepping integration procedure and Roe's flux difference splitting approximation with MUSCL-TVD scheme. A homogeneous equilibrium cavitation model is used. The method permits simple treatment of the whole gas-liquid two-phase flow field including wave propagation, large density changes and incompressible flow characteristics at low Mach number. By this method, two-dimensional internal flows through a venturi tuve and decelerating cascades are computed and discussed.

  • PDF

EXAMPLES OF REDUCED ORDER MODELLING FOR A 3D BACKWARD FACING STEP FLOW USING POD TECHNIQUE (POD를 사용한 3차원 후향계단 유동장 분석 예제)

  • Lee, K.S.;Lee, E.S.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2010.05a
    • /
    • pp.40-42
    • /
    • 2010
  • Unsteady CFD results of the backward facing step (BFS) flow field is reconstructed by the low-dimenstional modes using the POD (Proper Orthogonal Decomposition) technique. Flow responses to the blowing or suction with various frequencies and amplitudes applied at the edge of the BFS can also be analysed using the same technique. The present technique can be effectively applied to the feedback flow control device.

  • PDF

Experimental Study on the Flow Characteristics in a Low Speed Research Compressor (연구용 저속 축류압축기의 내부 유동 특성에 관한 실험적 연구)

  • Park, Tae-Choon;Han, Jung-Youp;Kang, Shin-Hyoung
    • The KSFM Journal of Fluid Machinery
    • /
    • v.11 no.6
    • /
    • pp.54-63
    • /
    • 2008
  • A study on the flow characteristics in a 4-stage axial compressor and the behavior of rotating stall was experimentally performed at the third-stage rotor and stator rows in order to investigate its performance and instability of the compression system. The pressure losses generated due to the leakage flow at a tip clearance and a shroud seal clearance and the wake flow near the trailing edge of a blade were taken into consideration to estimate the causes of performance drop of the low speed research compressor(LSRC) in Seoul national university. In addition, the measurement of rotating stall was conducted with hot-wire probes and the existence and propagation of stall cell could be confirmed through fast Fourier transform and cross-correlation analysis.

Effects of turbulent boundary layer thickness on flow around a low-rise rectangular prism

  • Kim, Kyung Chun;Ji, Ho Seong;Seong, Seung Hak
    • Wind and Structures
    • /
    • v.8 no.6
    • /
    • pp.455-467
    • /
    • 2005
  • The effects of upstream velocity profiles on the flow around a low-rise rectangular prism submerged in a turbulent boundary layer have been investigated. Three different boundary layer profiles are generated, which are characterized by boundary layer height, displacement thickness, and momentum thickness. Flow characteristics variations caused by the different layers such as those in turbulent kinetic energy distribution and locations of re-circulating cavities and reattachment points have been precisely measured by using a PIV (Particle Image Velocimetry) technique. Observations were made in a boundary layer wind tunnel at $Re_H$=7900, based on a model height of 40 mm and a free stream velocity of 3 m/s with 15 - 20% turbulence intensity.

Power Flow Study of Low-Voltage DC Micro-Grid and Control of Energy Storage System in the Grid

  • Kim, Dong-Eok
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.2
    • /
    • pp.549-558
    • /
    • 2017
  • DC distribution has several differences compared to AC distribution. DC distribution has a higher efficiency than AC distribution when distributing electricity at the same voltage level. Accordingly, power can be transferred further with low-voltage DC. In addition, power flow in a DC grid system is produced by only a voltage difference in magnitude. Owing to these differences, operation of a DC grid system significantly differs from that of an AC system. In this paper, the power flow problem in a bipolar-type DC grid with unbalanced load conditions is organized and solved. Control strategy of energy storage system on a slow time scale with power references obtained by solving an optimization problem regarding the DC grid is then proposed. The proposed strategy is verified with computer simulations.

Compressor Performance with Variation of Diffuser Vane Angle (디퓨저 베인각의 변화에 따른 압축기 성능 특성)

  • Shin, Y. H.;Kim, K. H.;Bae, M. H,;Kim, J. H.
    • The KSFM Journal of Fluid Machinery
    • /
    • v.3 no.2 s.7
    • /
    • pp.36-43
    • /
    • 2000
  • This study presents the centrifugal compressor performance for three different vane stagger angles and wall pressure distribution within vaned diffuser channels, and is also discussed about the stability with respect to the compressor components. As the vane stagger angle decreases, the flow rate for the stall onset decreases, and higher pressure can be obtained at the low flow rate region, however, the effective operation range of the compressor decreases because of the blockage effect of the diffuser vane. Low pressure pocket within the vaned diffuser channel moves from the pressure side of leading edge to the suction side as the flow rate decreases. The compressor system stability mainly depends on that of the diffuser.

  • PDF

Numerical Study of Important Factors for a Vortex Shedder using Automated Design Cycle

  • Nyein, Su Myat;Xu, He
    • International Journal of Fluid Machinery and Systems
    • /
    • v.8 no.3
    • /
    • pp.124-131
    • /
    • 2015
  • The good performance of a vortex shedder is defined by strong and stable vortex generated under the condition of most linearity in Strouhal number and low power loss. In this paper, the flow past a bluff body of circular cylinder with a slit normal to the flow has been analyzed focusing on drag coefficient, linearity of Strouhal number and flow resistance (K-factor). The ANSYS/FLUENT package is used for flow simulation and the integration method of computational code to iSIGHT platform is employed for automated design cycle. This study results the design with (0.20~0.267) blockage ratio and 0.10 slit ratio as the best shedder for vortex flowmeter and this results are in well agreement with the experiment. As the combination of GAMBIT, FLUENT, and iSIGHT substitutes the design parameters automatically according to the input data, this method designs effectively the vortex shedder with less design cycle time and low manufacturing cost eliminating the human intervention bottleneck.

Study of Hydraulic Modeling in South Han River by HEC-RAS (HEC-RAS를 이용한 남한강 수계의 수리모델링에 관한 연구)

  • Chang, In-Soo;Park, Ki-Bum
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.8 no.4
    • /
    • pp.213-220
    • /
    • 2005
  • The Youngwal 1, Youngwal 2 and Youngchun gaging stations are observed flood flow and low flow during Mar. 2004~Oct. 2004. They are observed water stages and flow velocities for flood and low flow. The observed data are used to derived rating curve and equations. The HEC-RAS model is applied for hydraulic modeling in gauging stations. The model is designed to perform one-dimensional hydraulic calculations for an river improvement plan in a full network of natural and constructed channels, and is comprised of a graphical user interface(GUI), separate hydraulic analysis components, data storage and management capabilities, graphics and reporting facilities.

  • PDF