비선형 저레이놀즈수 κ-ε 난류모델에 따른 정사각형 덕트내 완전 발달된 난류유동 예측 (Prediction of Fully Developed Turbulent Flow in a Square Duct with Nonlinear Low-Reynolds-Number κ-ε Models)

  • 명현국
    • 대한기계학회논문집B
    • /
    • 제27권6호
    • /
    • pp.821-827
    • /
    • 2003
  • Fully developed turbulent flow in a square duct is numerically predicted with two nonlinear low-Reynolds-number ${\kappa}-{\varepsilon}$ models. Typical predicted quantities such as axial and secondary velocities, turbulent kinetic energy and Reynolds stresses are compared in detail with each other. It is found that the nonlinear low-Reynolds-number ${\kappa}-{\varepsilon}$ model adopted in a commercial code is unable to predict accurately duct flows involving turbulence-driven secondary motion with the prediction level of secondary flows one order less than that of the experiment.

저속풍동실험 및 유동해석을 통한 고속전철 판토그라프의 유동소음 해석 (Prediction of Aeroacoustics Noise of Pantograph via Low Speed Wind Tunnel Test and Flow Simulation)

  • 조운기;이종수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 추계학술대회논문집 II
    • /
    • pp.1207-1214
    • /
    • 2001
  • The paper deals with the computational approach in analysis and design of pantograph panhead strips of high-speed railway in aerodynamic and aeroacoustic concerns. Pantograph is an equipment such that the electric power is supplied from catenary system to train. Due to the nature of complexity in high-speed fluid flow, turbulence and downstream vortices result in the instability in the aerodynamic contact between panhead strips and catenary system, and consequently generate the considerable levels of flow-induced sound. In this paper, based on the preceding low speed wind-tunnel test and simulations, the aerodynamic and aeroacoustic characteristics in low speed are analyzed.

  • PDF

재생펌프의 누설 유동 및 내부 유동에 관한 연구 (Study on the Leakage Flow and the Flow Analysis of Regenerative Pump)

  • 심창열;강신형
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.593-596
    • /
    • 2002
  • Flows in a regenerative pump were calculated for several flow-rates, using the CFX-Tascflow. The calculated results show the vortex structure in the impeller and side channel. The predicted performance shows considerable discrepancy form the measured values for low flow rates. Main source of the difference is the leakage flow of pump strongly affecting the performance of pump. A simple correlation was proposed using calculated leakage flows through the parametric calculations of the simplified passage.

  • PDF

A Behavior of the Diffuser Rotating Stall in a Low Specific Speed Mixed-Flow Pump

  • Miyabe, Masahiro;Furukawa, Akinori;Maeda, Hideaki;Umeki, Isamu;Jittani, Yoshinori
    • International Journal of Fluid Machinery and Systems
    • /
    • 제2권1호
    • /
    • pp.31-39
    • /
    • 2009
  • The flow instability in a low specific speed mixed-flow pump, having a positive slope of head-flow characteristics was investigated. Based on the static pressure measurements, it was found that a rotating stall in the vaned diffuser occurs at about 65% flow rate of best efficiency point (BEP). A dynamic Particle Image Velocimetry (DPIV) measurement and the numerical simulations were conducted in order to investigate the flow fields. As a result, the diffuser rotating stall was simulated even by Computational Fluid Dynamics (CFD) and the calculated periodic flow patterns agree well with the measured ones by DPIV. It is clarified that a periodical large scaled backflow, generated at the leading edge of the suction surface of the diffuser vane, causes the instability. Furthermore, the growth of the strong vortex at the leading edge of the diffuser vane induces the strong backflow from the diffuser outlet to the inlet. The scale of one stall cell is covered over four-passages in total thirteen vane-passages.

감조하천에서 조위 및 유량조건에 따른 역류 분석 (Analysis of Flow Reversal by Tidal Elevation and Discharge Conditions in a Tidal River)

  • 송창근;김형준;이동섭
    • 한국안전학회지
    • /
    • 제29권6호
    • /
    • pp.104-110
    • /
    • 2014
  • The Han River is the only waterway in Korea where estuary is not blocked by dykes so that tidal water is flowing in and out through the tidal reach. The extreme tidal range in the Yellow Sea causes an intense flood current, stretching over horizontal extents of tens of kilometers into the rivers. To elucidate the flow reversal by discharge conditions and transient tidal level in the Han river, numerical simulations were conducted under 7 boundary conditions for two days with 10 minute time step. As the flow conditions changed from low discharge and high tidal difference to high discharge and low tidal difference, the flow reversals became weaker and the velocity of forward flow direction became higher due to the increased flow momentums and decreased tidal differences. In the case of normal flow, the maximum reverse velocity was 0.4 m/s, which was equivalent to the maximum forward velocity. In addition, the pattern of the development and decay of forward and reverse flow was presented.

선형터빈 케스케이드 통로내의 2차 유동과 손실에 관한 연구 (The Experimental Investigation of the Secondary Flow and Losses Within the Plane Turbine Cascade Passage)

  • 이기백;양장식;나종문
    • 대한기계학회논문집
    • /
    • 제19권3호
    • /
    • pp.784-795
    • /
    • 1995
  • This paper represents the results of the experiments of the three-dimensional flow and the aerodynamic loss caused by the three-dimensional flow within the plane bucket blades. To research the secondary flow and the aerodynamic loss, the large-scale plane bucket blade of lst-stage in the low pressure steam turbine is made of FRP. The detailed investigation of the secondary flow and the aerodynamic loss using 5-hole pressure probe within turbine cascade has been carried out in the low speed wind tunnel. The limiting streamlines of the suction and endwall surface have been visualized by the oil film method. The flow visualization of the secondary flow has been performed by the laser light sheet technique and image processing system. By using the method mentioned above, it is possible to observe the evolution of the pitchwise mass-averaged flow deviation angle and total pressure loss coefficient, the secondary flow, and the aerodynamic loss through the cascade.

개방된 챔버 입구에서 작동하는 소형 프로펠러 팬 주위의 난류유동해석 (Numerical analysis of turbulent flow around a small propeller fan operating at the inlet of open chamber)

  • 오건제;강신형
    • 대한기계학회논문집B
    • /
    • 제21권12호
    • /
    • pp.1586-1594
    • /
    • 1997
  • Performance characteristics of a small propeller fan are numerically investigated solving the continuity and Reynolds-averaged Navier-Stokes equations. The Reynolds stresses for turbulent transport are modelled using a k-.epsilon. turbulence model. The present numerical procedure is constructed using the Finite Volume Method with the SIMPLE algorithms. The performance parameters obtained from the calculations are compared with the measured values for the various flow rates. A performance test of the fan shows different characteristics between a radial type at small flow rates and an axial type at large flow rates. Comparisons between the predictions and the measurements show that the predicted results are in good agreement with the measured values and reasonably reproduce the sharp variations of the power and head coefficient around a flow coefficient .PHI.=0.3. These comparisons indicate that the present numerical method is capable of resolving the performance characteristics with reasonable accuracy. At low flow rates, it is found that the flow enters the fan in an axial direction and is discharged radially outward at the tip which happens in the centrifugal fan. The centrifugal effect makes a significant difference in the characteristics of a fan at the low and high values of flow coefficient.

임펠러 출구각 및 리어가이더 형상 변화에 따른 횡류홴의 성능 특성 (Performance Characteristics of a Cross-Flow Fan with Various Impeller Outlet Angles and Rearguiders)

  • 김형섭;김동원;윤태석;박성관;김윤제
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.851-856
    • /
    • 2003
  • A cross-flow fan consists of an impeller, a stabilizer and a rearguider. When it applied for an air conditioner, an evaporator should be added. It relatively makes high dynamic pressure at low speed because a working fluid passes through an impeller blade twice and blades have a forward curved shape. Therefore, the performance of a cross-flow fan is influenced 25% by the impeller, 60% by the rearguider and the stabilizer, 15% by the heat exchanger. At the low flow rate, there are a rapid pressure head reduction, a noise increase and an unsteady flow against a stabilizer and a rearguider. Moreover, the reciprocal relation between the impeller and the flow passage is the important factor for performance improvement of the cross-flow tan because each parameter is independent. The performance characteristics in the cross-flow fan are graphically depicted with various impeller outlet angles and rearguiders.

  • PDF

도공액의 보수성에 관한연구(제4보)- 알칼리 반응형 보수.유동성 개량제의 합성 - (A study on the Water Retention of Coating Colors(IV)-Synthesis of Alkali Sensitive Water Retention and Rheology Modifiers-)

  • 이용규;엄기용
    • 펄프종이기술
    • /
    • 제29권3호
    • /
    • pp.17-25
    • /
    • 1997
  • Natural water-soluble polymers such as starch, casein and carboxy methyl cellulose(CMC) have been limited in their uses. However, the proper water retention of coating colors can not be obtained without addition of these polymers. Furthermore, the coating runnability and the physical properties of coated paper were not also satisfied. Therefore, the objective of this study was to synthesize the water retention and flow modifiers which can improve the water retention and flow properties of coating colors. We have measured physical properties of flow modifiers and coating colors which included flow modifiers. The viscosity of flow modifiers was very low at acid pH, and rapidly increased at about pH 7, and gradually reached to equilibrium at alkali pH. Such an increase comes from the molecular weight of flow modifiers and the amount of acrylic and methacrylic acids. The viscosity of coating color containing the flow modifiers was lower than that containing CMC. However, both of them had little difference in water retention. The water-phase viscosity of synthetic modifier containing coating color was either higher or similar compared to that of CMC containing coating color. The high shear viscosity of coating colors was low. Therefore, it can be concluded that the synthetic flow modifiers are very useful for improvement of flow properties and water retentions.

  • PDF

수리실험을 이용한 지하유입시설 유입구 형상에 따른 수리학적 특성 분석 (Study of Hydraulic Characteristics with the Shape of the Intake of an Underground Inflow Facility using Hydraulic Experiments)

  • 성호제;박인환;이동섭
    • 한국안전학회지
    • /
    • 제33권4호
    • /
    • pp.119-126
    • /
    • 2018
  • In recent years, as flood damage caused by heavy rains increased, the great-depth tunnel using urban underground space is emerging as a countermeasure of urban inundation. The great-depth tunnel is used to reduce urban inundation by using the underground space. The drainage efficiency of great-depth tunnel depends on the intake design, which leads to increase discharge into the underground space. The spiral intake and the tangential intake are commonly used for the inlet facility. The spiral intake creates a vortex flow along the drop shaft and reduces an energy of the flow by the wall friction. In the tangential intake, flow simply falls down into the drop shaft, and the design is simple to construct compared to the spiral intake. In the case of the spiral intake, the water level at the drop shaft entrance is risen due to the chocking induced by the flowrate increase. The drainage efficiency of the tangential intake decreases because the flow is not sufficiently accelerated under low flow conditions. Therefore, to compensate disadvantages of the previously suggested intake design, the multi-stage intake was developed which can stably withdraw water even under a low flow rate below the design flow rate. The hydraulic characteristics in the multi-stage intake were analyzed by changing the flow rate to compare the drainage performance according to the intake design. From the measurements, the drainage efficiency was improved in both the low and high flow rate conditions when the multi-stage inlet was employed.