• 제목/요약/키워드: Low-dose

검색결과 2,892건 처리시간 0.029초

흡연과 낮은 방사선 피폭량이 Lymphocyte DNA 손상에 미치는 영향 (The Influence of Smoking and Low Dose Radiation Exposure to the Damage of the Lymphocyte DNA)

  • 신현길;김윤주;권은혜;육진영;최수용
    • Environmental Analysis Health and Toxicology
    • /
    • 제18권4호
    • /
    • pp.237-242
    • /
    • 2003
  • Single cell gel electrophoresis (SCGE) was used to the experiment with the variation on the amount of smoking and low dose radiation exposure to find how much the Lymphocyte DNA was damaged, and especially for whom smoke a lot(about 20 or more than 20 cigarettes a day) it was found to be highly damaged. While, the damage of 'not more than 20 cigarettes a day' was found to be not so much significant as like for whom smoke about or more than 20 cigarettes a day And, according to the different amount of the radiation exposure, the Lymphocyte DNA was found to be considerably damaged for 0-13m Sv (P<0.01), it was not able to prove the relationship between the DNA damage and the radiation exposure.

수술 후 갑상선기능저하가 동반된 고도비만환자의 펜터민염산염/토피라메이트의 저용량 오프라벨 사용 (Low-Dose Off-Label Use of Phentermine/Topiramate in the Individual with Morbid Obesity and Postoperative Hypothyroidism)

  • 박정하
    • 비만대사연구학술지
    • /
    • 제1권1호
    • /
    • pp.43-45
    • /
    • 2022
  • Intensive lifestyle modifications and anti-obesity medications are essential for obesity treatment. Antiobesity medications should be selected according to the patient's comorbidities, symptoms, and preferences. This case report describes the treatment of a morbidly obese patient with a history of depression, who complained of tingling and numbness after total thyroidectomy for papillary thyroid cancer. Very low-dose controlled-release phentermine/topiramate was prescribed and intensive lifestyle modifications were encouraged. As a result, the patient effectively lost weight and reached a near-normal weight without adverse drug effects. This implies that even an off-label anti-obesity medication low dose may be better for some patients, and the most important factor in obesity treatment is patient-tailored treatment.

흉부 CT촬영에서 저선량 프로토콜의 선량과 화질: 표준선량 프로토콜과 비교 (Radiation Dose and Image Quality of Low-dose Protocol in Chest CT: Comparison of Standard-dose Protocol)

  • 이원정;안봉선;박영선
    • Journal of Radiation Protection and Research
    • /
    • 제37권2호
    • /
    • pp.84-89
    • /
    • 2012
  • 임상에서 사용하고 있는 흉부 CT촬영의 저선량 프로토콜과 표준선량 프로토콜 간의 선량과 화질을 비교 분석하였다. 흉부 저선량 프로토콜(120 kVp, 30 mAs)과 표준선량 프로토콜(120 kVp, 180 mAs)로 촬영($Brilliance^{TM}$ CT 16slice, PHILIPS)한 61명의 조영제를 사용하지 않은 영상에서 기관 분기부 위치의 종격동 영상을 본 연구를 위해 사용하였다. 상행대동맥과 가시아래근에서 CT number와 잡음을 측정하였고, Back-ground 잡음을 측정하여 신호대잡음비(signal-to-noise ratio. SNR)와 대조도잡음비(contrast-to-noise ratio, CNR)를 구하였다. 두부 아크릴 팬텀을 이용하여 선량을 측정하였고, 워터 팬텀으로 얻은 영상에서 CT number와 잡음을 측정하였다. 모든 측정은 3회 실시하여 평균값을 SPSS 프로그램(version 14.0)으로 분석하였고, 그래프는 시그마 플롯 프로그램(version10.0)을 사용하였다. 결과: 상행대동맥과 가시아래근에서 저선량 프로토콜 영상이 표준선량 프로토콜 영상 보다 유의하게 높은 잡음을 보였고, SNR과 CNR은 유의하게 낮았다. 두 영상에서 비만지수에 대한 잡음은 양의 관련성을 보였지만, SNR과 CNR은 음의 관련성을 보였다. 팬텀 결과에서 저선량 프로토콜의 선량이 표준선량 프로토콜 보다 유의하게 낮았지만(0.35 mGy vs. 1.95 mGy, p=0.008), 잡음은 저선량 프로토콜에서 유의하게 높았다(p=0.029). 저선량 프로토콜이 표준선량 프로토콜 보다 유의하게 낮은 선량을 보였지만, 화질 평가도 유의하게 낮은 결과를 보임으로서 임상에서 사용하는 저선량 프로토콜의 노출 선량은 화질을 고려하여 상향 조정할 필요가 있다.

우리나라 남동지방(南東地方)의 환경방사선(環境放射線) 선량율(線量率)의 결정(決定)(1980년도(年度)) (Determination of Environmental Radiation Dose Rate in the Southeastern Korea)

  • 노재식;이현덕
    • Journal of Radiation Protection and Research
    • /
    • 제5권1호
    • /
    • pp.1-6
    • /
    • 1980
  • A portable count-ratemeter and a thermoluminescent detector ($CaSO_4:Dy$) have been used to obtain total gamma dose rates at approximately 50 locations during the course of several survey trips in the southeastern Korea. The purposes of these measurement were to provide a future reference data and to establish the approximate range of population exposure to the natural environmental radiation. The natural levels encountered ranged from a low of 14.6 microroentgen per hour to a high of 18.9 microroentgen per hour with a mean of $16.3{\pm}1.0$ microroentgen per hour. Among these results are the relatively high natural dose rate levels in the Masan area and Yangsan-Tongdosa area with the relatively low natural dose rate levels in the Gyeongsan-Cheongdo area and the Samrangjin-Jinyeong-Gimhae area.

  • PDF

두경부암의 근접방사선 치료 (Brachytherapy for Head and Neck Cancer)

  • 류성렬
    • 대한두경부종양학회지
    • /
    • 제7권1호
    • /
    • pp.3-9
    • /
    • 1991
  • Brachytherapy is a method of radiotherapy in advantage to achieve better local control with minimum radiation toxicity in comparison with external irradiation because radiation dose is distributed according to the inverse square low of gamma-ray emitted from the implanted sources. The main characteristics of brachytherapy are delivering of higher dose to target volume shortening of total treatment period and sparing of normal tissue. Recent development of iridium ribbons for low dose rate implant provides improvement of technology of brachytherapy in terms of safety and efficiency. High dose rate method. on the other hand, is effective to avoid unnecessary expoure of medical personnel.

  • PDF

Low-dose radiation therapy for massive chylous leakage after subtotal gastrectomy

  • Kim, Sang-Won;Kim, Jung Hoon
    • Radiation Oncology Journal
    • /
    • 제35권4호
    • /
    • pp.380-384
    • /
    • 2017
  • Massive chylous leakage is a rare postoperative complication that can prolong hospital stay and cause secondary morbidities. Conservative management strategies are the treatment of choice; however, radiation therapy (RT) can be used as an alternative for cases that are refractory to conservative treatment. Herein, we report a 69-year-old female patient who suffered from massive chylous leakage after subtotal gastrectomy. Due to persistent massive chylous leakage, she was scheduled to undergo low-dose RT. Radiation was delivered with a daily dose of 1 Gy, using an anterior-posterior and posterior-anterior beam arrangement. The clinical target volume encompassed the entire lymph node area of the D2 dissection. RT was completed at the total dose of 8 Gy because the amount of chylous leakage declined rapidly. Percutaneous drainage tube was removed after 3 days of RT. The patient did not complain of any symptoms related to massive chylous leakage 2 years after the completion of RT.

악성 종양에 의한 기도폐쇄시 내기관지 근접치료 : 저선량 치료 대 고선량 치료의 비교 (Endobronchial Brachytherapy for Malignant Airway Obstruction: Low Dose Rate Versus High Dose Rate)

  • 조영갑
    • Radiation Oncology Journal
    • /
    • 제14권2호
    • /
    • pp.123-128
    • /
    • 1996
  • 목적 : 악성 종양으로 인해 기도 폐쇄가 온 환자들을 저선량 및 고선량으로 내기관지 근접 치료하였을 경우의 대중치료 효과, 생존율 및 병발증을 비교 검토한다. 대상 및 방법 : 1988년 10월부터 1992년 6월까지 저선량 방법으로 21명, 1992년 8월부터 1994년 4월까지 고선량 방법으로 22명, 총 43명의 환자들에게 내기관지 근접치료를 시행하였다. 총 91회의 치료시, 모두 Fluorocopy하에서 굴절성 Fiberoptlc 내시경을 이용하였으며, 저선량 방법의 21회는 15-30 Gy를 0.75 cm 원경에, 고선량 방법의 64회는 5-7.5 Gy를 Ir-192 선원으로부터 1 Cm 원경에 각각 투사하였다. 결과 : 주관적 및 객관적 치료효과의 분석은 임상재진시 나타난 환자의 증상, 흥부 방사선 사진 및 흥부 단층촬영의 결과로 이루어졌다. 저산량으로 치료한 21명 중 15명의 환자와 고선량으로 치료한 22명 중 19명의 환자들이 주관적 치료효과가 있었음을 보였고, 8명의 저선량 환자와 10명의 고선량 환자가 흥부 방사선 사진과 단층 촬영상에서 객관적 효과가 있었음을 나타냈다. 결론 : 저선량 및 고선량 방사선에 의해 근접치료의 기술은 비교적 간단하며 환자가 별다른 후유증 없이 치료를 잘 받아 드리는 편이다. 이 치료 방법은 여생이 얼마 남지 않은 말기 폐암환자에게 내기관지 협착 내지는 폐쇄가 왔을 때 기관지의 공기소통을 원활히 증진시켜주는 대증치료 방법 이다.

  • PDF

Effect of Low Magnetic Field on Dose Distribution in the SABR Plans for Liver Cancer

  • Son, Jaeman;Chun, Minsoo;An, Hyun Joon;Kang, Seong-Hee;Chie, Eui Kyu;Yoon, Jeongmin;Choi, Chang Heon;Park, Jong Min;Kim, Jung-in
    • 한국의학물리학회지:의학물리
    • /
    • 제29권2호
    • /
    • pp.47-52
    • /
    • 2018
  • To investigate the effect of low magnetic field on dose distribution in SABR plans for liver cancer, we calculated and evaluated the dose distribution to each organ with and without magnetic fields. Ten patients received a 50 Gy dose in five fractions using the $ViewRay^{(R)}$ treatment planning system. For planning target volume (PTV), the results were analyzed in the point minimum ($D_{min}$), maximum ($D_{max}$), mean dose ($D_{mean}$) and volume receiving at least 90% ($V_{90%}$), 95% ($V_{95%}$), and 100% ($V_{100%}$) of the prescription dose, respectively. For organs at risk (OARs), the duodenum and stomach were analyzed with $D_{0.5cc}$ and $D_{2cc}$, and the remained liver except for PTV was analyzed with $D_{mean}$, $D_{max}$, and $D_{min}$. Both inner and outer shells were analyzed with the point $D_{min}$, $D_{max}$, and $D_{mean}$, respectively. For PTV, the maximum change in volume due to the presence or absence of the low magnetic field showed a percentage difference of up to $0.67{\pm}0.60%$. In OAR analysis, there is no significant difference for the magnetic field. In both shell structure analyses, although there are no major changes in dose distribution, the largest value of deviation for $D_{max}$ in the outer shell is $2.12{\pm}2.67Gy$. The effect of low magnetic field on dose distribution by a Co-60 beam was not significantly observed within the body, but the dose deposition was only appreciable outside the body.

인터벤션 시 방사선조사 조건에 따른 선량감소 : 면적선량과 영상화질 변화를 중심으로 (Dose Reduction According to the Exposure Condition in Intervention Procedure : Focus on the Change of Dose Area and Image Quality)

  • 황준호;정구민;김현수;강병삼;이경배
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제40권3호
    • /
    • pp.393-400
    • /
    • 2017
  • 본 연구는 NEMA Phantom을 사용하여 관전류량 변화에 따른 면적선량과 영상화질의 분석을 통해 선량을 감소할 수 있는 방법을 제시하고자 하였다. 인터벤션의 특성상 중요한 화질평가 항목인 공간 분해능, 저 대조도 분해능과 함께 신호 대 잡음비(Signal to Noise Ratio; SNR), 대조도 대 잡음비(Contrast to Noise Ratio; CNR)를 평가기준으로 하였고, 관전압은 80 kVp로 고정하고, 관전류량을 20, 30, 40, 50 mAs로 변화시켜 면적선량과 영상화질을 비교분석하였다. 그 결과 관전압을 고정한 상태에서 면적선량은 조건이 증가함에 따라 $1,066mGycm^2$에서 $6,160mGycm^2$으로 약 6배까지 증가하였고, 공간분해능과 저 대조도 분해능은 20 mAs, 30 mAs에서 평가기준보다 높게 관찰되었으나 40 mAs는 공간 분해능, 50 mAs에서는 공간 분해능과 저 대조도 분해능이 평가기준 이하로 관찰되었다. 또한 SNR과 CNR은 30 mAs까지는 증가하다 40 mAs에서 다소 증가하기는 하였으나 이전과 큰 차이가 없었고, 50 mAs에서는 감소하는 경향을 보였다. 결론적으로 관전류의 과잉노출로 피폭선량이 증가하고, 공간 분해능, 저 대조도 분해능, SNR, CNR 모든 영역에서 영상화질이 저하된다는 것을 알 수 있었고, 적절한 관전류량의 설정으로 인터벤션에서 피폭선량을 줄이고 영상화질을 충분히 개선할 수 있다는 것을 알 수 있었다.

A review of two theories of motion sickness and their implications for tall building motion sway

  • Walton, D.;Lamb, S.;Kwok, Kenny C.S.
    • Wind and Structures
    • /
    • 제14권6호
    • /
    • pp.499-515
    • /
    • 2011
  • Low-frequency building vibration is known to induce symptoms of motion sickness in some occupants. This paper examines how the adoption of a theory of motion sickness, in conjunction with a dose-response model might inform the real-world problem of managing and designing standards for tall building motion sway. Building designers require an understanding of human responses to low-dosage motion that is not adequately considered by research into motion sickness. The traditional framework of Sensory Conflict Theory is contrasted with Postural Instability Theory. The most severe responses to motion (i.e., vomiting) are not experienced by occupants of wind-excited buildings. It is predicted that typical response sets to low-dosage motion (sleepiness and fatigue), which has not previously been measured in occupants of tall-buildings, are experienced by building occupants. These low-dose symptoms may either be masked from observation by the activity of occupants or misattributed to the demands of a typical working day. An investigation of the real-world relationship between building motion and the observation of low-dose motion sickness symptoms and a degradation of workplace performance would quantify these effects and reveal whether a greater focus on designing for occupant comfort is needed.