• Title/Summary/Keyword: Low-cost solution

검색결과 666건 처리시간 0.031초

Module solution with Integrated Shunt for GPI, General Purpose Inverter: Shunt embedded Econo module

  • Kim, Simon
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2017년도 전력전자학술대회
    • /
    • pp.596-597
    • /
    • 2017
  • For General Purpose Inverter dedicated in Motor drive, this market is blood market due to low market price. So, developing engineer must consider the cost reduction plan and do action. This inverter always needs to measure current and shunt solution can be one of cost reduction solution.

  • PDF

액제 정밀계량장치를 이용한 액제 자동조제 시스템개발 (Development of Automatic Nutrient-Solution Control System Using a Low -Cost and Precise Liquid Metering Device)

  • 류관희;홍순호;이규철;이정훈;황호준
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 1997년도 하계 학술대회 논문집
    • /
    • pp.89-98
    • /
    • 1997
  • This study was conducted to develop an automatic nutrient-solution control system for small-scale growers. The nutrient-solution control system consisted of a low-cost and precise metering device and a personal computer. The system controlled electric conductivity(EC) and pH of nutrient-solution based on the time-based feedback control method with the information about temperature, EC, and pH of the nutrient-soIution. The performance of the nutrient-solution control system was evaluated through the control of EC and pH while compared with those of commercial nutrient-solution control system. Also an experimental cultivation of tomato was conducted to verify and to improve the developed system. Results of this study were as follows. 1. An automatic nutrient-solution control system based on a low-cost and precise metering device was developed. 2. The developed system controlled EC and pH within $\pm$0.05 mS/cm and $\pm$0.2 pH full scale error respectively at $24^{/circ}C$. 3. When using the commercial system, the controlled values of EC and pH of the 500l of water were 1.29 mS/cm and 6.1 pH for the setting points of 1.4 mS/cm and 6.0 pH respectively at $22^{/circ}C$. 4. The developed nutrient-solution control system showed $\pm$0.05 mS/cm of deviation from the setting EC value over the experimental cultivation period. 5. The deviation from the average values of Ca and Mg mass content in the several nutrient-solution were 0.5% and 1.8% respectively.

  • PDF

저에너지 공동주택 구현을 위한 요소기술 선정 기법에 관한 연구 (Energy Saving Design Method with the Consideration of the Initial Cost for Apartment Houses)

  • 손원득;이종일;윤대원;이건호;송두삼
    • 한국태양에너지학회 논문집
    • /
    • 제34권2호
    • /
    • pp.24-31
    • /
    • 2014
  • So many energy saving strategies to realize the low energy house are proposed in these days. Even if the energy saving performances are similar between the strategies, the costs are in abroad ranges. Therefore, the application of the energy saving strategies should be based upon two considerations; one is energy saving performance and the other is the cost. In this study, the decision making method for application of the passive design technologies in the design stage of the low energy apartment house are suggested. By utilizing the result of this study, practitioners can make an effective design alternatives which solve the conflicted values; energy saving and cost.

Application of eddy current technique for the non-contact sensing of low concentration of electrolytic solution

  • Ismail, Abu Bakar Md.;Shida, Katsunor
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1997년도 한국자동제어학술회의논문집; 한국전력공사 서울연수원; 17-18 Oct. 1997
    • /
    • pp.1310-1313
    • /
    • 1997
  • Application of eddy current sensing principle for the non-contact estimation of very low concentration of electrolytic solution is presented in this paper. for this application, a new, simple, low-cost, low-power structure for the eddy current sensor is proposed. By measuring the eddy current produced in the conducting electrolytic solution, the concentration is estimated. Therefore, the unknown concentration can be estimated comparing with the database which is prepared as the relation between the change in inductance and various concentrations of electrolytic solution. The concentration, as low as l ppm of the solutioin can be detected by this sensor. It was tested on various low concentration solutions of NaCl. It shows distinct response for various concentrations.

  • PDF

Development of a Low-cost Metering Device for Automatic Mixing of Nutrient-Solution

  • Ryu, K.H.;Lee, K.C.;Lee, J.H.
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 1996년도 International Conference on Agricultural Machinery Engineering Proceedings
    • /
    • pp.1117-1125
    • /
    • 1996
  • A low-cost and precise metering device, which is suitable to automatic mixing of nutrient-solution for hydroponic culture, was developed for small-scale growers. The metering accuracy of the metering device developed was compared with commercial metering pumps. The mixing performance through the control of EC and pH was also evaluated. The accuracy of the metering device in terms of the full -scale error was $\pm$0.3% , which was much better compared to $\pm$2.45% and $\pm$1.38% for the two types of commercial metering pumps. The mixing system of nutrient-solution with the metering device showed a satisfactory control performance with the accuracies of $\pm$0.05mS/cm and$\pm$0.2pH for EC and pH, respectively.

  • PDF

In-camera VFX implementation study using short-throw projector (focused on low-cost solution)

  • Li, Penghui;Kim, Ki-Hong;Lee, David-Junesok
    • International Journal of Internet, Broadcasting and Communication
    • /
    • 제14권2호
    • /
    • pp.10-16
    • /
    • 2022
  • As an important part of virtual production, In-camera VFX is the process of shooting actual objects and virtual three-dimensional backgrounds in real-time through computer graphics technology and display technology, and obtaining the final film. In the In-camera VFX process, there are currently only two types of medium used to undertake background imaging, LED wall and chroma key screen. Among them, the In-camera VFX based on LED wall realizes background imaging through LED display technology. Although the imaging quality is guaranteed, the high cost of LED wall increases the cost of virtual production. The In-camera VFX based on chroma key screen, the background imaging is realized by real-time keying technology. Although the price is low, due to the limitation of real-time keying technology and lighting conditions, the usability of the final picture is not high. The short-throw projection technology can compress the projection distance to within 1 meter and get a relatively large picture, which solves the problem of traditional projection technology that must leaving a certain space between screen and the projector, and its price is relatively cheap compared to the LED wall. Therefore, in the In-camera VFX process, short-throw projection technology can be tried to project backgrounds. This paper will analyze the principle of short-throw projection technology and the existing In-camera VFX solutions, and through the comparison experiments, propose a low-cost solution that uses short-throw projectors to project virtual backgrounds and realize the In-camera VFX process.

Ring-VCO를 이용한 멀티밴드 GPS 수신기용 PLL 설계 (A Ring VCO Based PLL for Low-Cost, Low-Power Multi-Band GPS Receiver)

  • 김윤진;소병성;고진호;박근형
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 하계학술대회 논문집 Vol.9
    • /
    • pp.533-534
    • /
    • 2008
  • This paper presents a multi-phase ring VCO for low-cost, low-power GPS receiver. In the RF band used in GPS, L1 band is now in commercial-use and L2,L5 are predicting to be commercial-use soon. Thus Wide band PLL and Cost-effective IC solutions are required for future multi-band GPS receiver that received three types band at once. A new PLL architecture for multi-band GPS application is proposed. Ring VCO is even smaller than LC-VCO and a good alternative for low-cost solution. Proposed multi-phase ring VCO offers wide frequency range covering L1, L2, and L5 band, 20% reduction of area, 23% reduction of PLL power and can generate I/Q without extra I/Q generator.

  • PDF

퍼지제어를 이용한 양액 자동공급 시스템 개발 (Development of an Automatic Nutrient-Solution Supply System Using Fuzzy Control)

  • 황호준;류관희;조성인;이규철;김기영
    • Journal of Biosystems Engineering
    • /
    • 제23권4호
    • /
    • pp.365-372
    • /
    • 1998
  • This study was carried out to develop a nutrient-solution mixing-and-supplying system, which used a low-cost metering device instead of expensive metering pumps and a fuzzy logic controller. A low cost and precise overflow-type metering device was developed and evaluated by testing the flow discharge for the automatic nutrient-solution mixing-and-supplying system for snail-scale hydroponic sewers. The fuzzy logic controllers, which could predict and meet the desired values of EC and supply rate of nutrient solution were developed and verified by simulation and experiment. this fuzzy logic controller, whose algorithm consists of four crisp inputs, two crisp outputs and nine rules, was developed to predict the desired value of EC and supply rate of nutrient solution and two crisp inputs, one crisp output and nine rules used to control EC to the desired values. The nutrient-solution mixing-and-supplying system showed satisfactory EC control performance with the maximum overshooting of 0.035 mS/cm and the maximum settling time of 15 minutes in case of increasing 0.7 mS/cm. also, the accuracy of the overflow-type metering device in terms of the full-scale error was 2.29% when using solenoid valve only and 0.2% when using solenoid valve and flow control valve together.

  • PDF

결정질 실리콘 태양전지에 적용하기 위한 도금법으로 형성환 Ni/Cu 전극에 관한 연구 (Investigation of Ni/Cu Contact for Crystalline Silicon Solar Cells)

  • 김범호;최준영;이은주;이수홍
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 춘계학술대회
    • /
    • pp.250-253
    • /
    • 2007
  • An evaporated Ti/Pd/Ag contact system is most widely used to make high-efficiency silicon solar cells, however, the system is not cost effective due to expensive materials and vacuum techniques. Commercial solar cells with screen-printed contacts formed by using Ag paste suffer from a low fill factor and a high shading loss because of high contact resistance and low aspect ratio. Low-cost Ni and Cu metal contacts have been formed by using electroless plating and electroplating techniques to replace the Ti/Pd/Ag and screen-printed Ag contacts. Ni/Cu alloy is plated on a silicon substrate by electro-deposition of the alloy from an acetate electrolyte solution, and nickel-silicide formation at the interface between the silicon and the nickel enhances stability and reduces the contact resistance. It was, therefore, found that nickel-silicide was suitable for high-efficiency solar cell applications. The Ni contact was formed on the front grid pattern by electroless plating followed by anneal ing at $380{\sim}400^{\circ}C$ for $15{\sim}30$ min at $N_{2}$ gas to allow formation of a nickel-silicide in a tube furnace or a rapid thermal processing(RTP) chamber because nickel is transformed to NiSi at $380{\sim}400^{\circ}C$. The Ni plating solution is composed of a mixture of $NiCl_{2}$ as a main nickel source. Cu was electroplated on the Ni layer by using a light induced plating method. The Cu electroplating solution was made up of a commercially available acid sulfate bath and additives to reduce the stress of the copper layer. The Ni/Cu contact was found to be well suited for high-efficiency solar cells and was successfully formed by using electroless plating and electroplating, which are more cost effective than vacuum evaporation. In this paper, we investigated low-cost Ni/Cu contact formation by electroless and electroplating for crystalline silicon solar cells.

  • PDF

Performance Evaluation of the Low-cost, High-precision RTK Device RTAP2U for GPS-based Precise Localization

  • Kim, Hye-In;Kim, Yeong-Guk;Park, Kwan-Dong
    • Journal of Positioning, Navigation, and Timing
    • /
    • 제10권1호
    • /
    • pp.67-73
    • /
    • 2021
  • The need for precise location data is growing across numerous markets, and so is the number of affordable high-precision GPS receivers. In this paper, we validated the performance of RTAP2U, a low-cost high-precision RTK receiver that was recently released. Two positioning modes were tested: static and driving. The static test conducted Zero-Baseline Single-RTK and Network-RTK survey for 57 hours and 51 hours, respectively. For the driving test, Network-RTK survey was conducted using VRS services provided by NGII based on Trimble PIVOT and Geo++ GNSMART. The static test showed about 1 cm horizontal and vertical accuracies, which is very stable considering the test duration longer than 50 hours. The integer ambiguity FIX rate marked a solid 100%. The driving test result also reached a 100% FIX rate. Horizontal and vertical accuracies were better than 2 cm and 3 cm, respectively. Researchers can refer to this paper when considering affordable high-precision GPS receivers as an option.