Application of eddy current technique for the non-contact sensing of low concentration of electrolytic solution
- Ismail, Abu Bakar Md. (Department of Electrical Engineering, Saga University) ;
- Shida, Katsunor (Department of Electrical Engineering, Saga University)
- Published : 1997.10.01
Abstract
Application of eddy current sensing principle for the non-contact estimation of very low concentration of electrolytic solution is presented in this paper. for this application, a new, simple, low-cost, low-power structure for the eddy current sensor is proposed. By measuring the eddy current produced in the conducting electrolytic solution, the concentration is estimated. Therefore, the unknown concentration can be estimated comparing with the database which is prepared as the relation between the change in inductance and various concentrations of electrolytic solution. The concentration, as low as l ppm of the solutioin can be detected by this sensor. It was tested on various low concentration solutions of NaCl. It shows distinct response for various concentrations.