• Title/Summary/Keyword: Low-contrast Image

Search Result 449, Processing Time 0.03 seconds

Investigation of light stimulated mouse brain activation in high magnetic field fMRI using image segmentation methods

  • Kim, Wook;Woo, Sang-Keun;Kang, Joo Hyun;Lim, Sang Moo
    • Journal of the Korea Society of Computer and Information
    • /
    • v.21 no.12
    • /
    • pp.11-18
    • /
    • 2016
  • Magnetic resonance image (MRI) is widely used in brain research field and medical image. Especially, non-invasive brain activation acquired image technique, which is functional magnetic resonance image (fMRI) is used in brain study. In this study, we investigate brain activation occurred by LED light stimulation. For investigate of brain activation in experimental small animal, we used high magnetic field 9.4T MRI. Experimental small animal is Balb/c mouse, method of fMRI is using echo planar image (EPI). EPI method spend more less time than any other MRI method. For this reason, however, EPI data has low contrast. Due to the low contrast, image pre-processing is very hard and inaccuracy. In this study, we planned the study protocol, which is called block design in fMRI research field. The block designed has 8 LED light stimulation session and 8 rest session. All block is consist of 6 EPI images and acquired 1 slice of EPI image is 16 second. During the light session, we occurred LED light stimulation for 1 minutes 36 seconds. During the rest session, we do not occurred light stimulation and remain the light off state for 1 minutes 36 seconds. This session repeat the all over the EPI scan time, so the total spend time of EPI scan has almost 26 minutes. After acquired EPI data, we performed the analysis of this image data. In this study, we analysis of EPI data using statistical parametric map (SPM) software and performed image pre-processing such as realignment, co-registration, normalization, smoothing of EPI data. The pre-processing of fMRI data have to segmented using this software. However this method has 3 different method which is Gaussian nonparametric, warped modulate, and tissue probability map. In this study we performed the this 3 different method and compared how they can change the result of fMRI analysis results. The result of this study show that LED light stimulation was activate superior colliculus region in mouse brain. And the most higher activated value of segmentation method was using tissue probability map. this study may help to improve brain activation study using EPI and SPM analysis.

A Portable Micro-display Driver and Device for Vision Improvement (시력 향상을 위한 휴대형 마이크로디스플레이 구동 드라이버 및 장치)

  • Ryu, Young-Kee;Oh, Choonsuk
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.16 no.3
    • /
    • pp.129-135
    • /
    • 2016
  • There are many visual enhancement devices for people with low vision. However, almost conventional devices have been simple magnifying and high cost. The symptoms of people with low vision are very variety. It needs to control of image magnifying, brightness, and contrast to improve the visuality. We developed a portable microdisplay driver and device for visual enhancement. This device based on our suggested four methods such as image magnifying, specific color control, BLU brightness control, and visual axis control using a prism. The basic clinical experiments of the proposed Head Mounted Visual Enhancement Device (HMVED) have been performed. The results show beneficiary effects compared with conventional devices, and improve the life quality on people with low vision on account of low weight, low cost, and easy portability.

Color Image Compensation Method Based on Retinex For Improving Visual Image Quality (영상 화질 개선을 위한 레티넥스 기반 영상 보정 기법)

  • Choi, Ho-Hyong;Kim, Hyun-Deok;Yun, Byoung-Ju
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.829-830
    • /
    • 2008
  • In modern days, many of the images are captured by using various devices, such as PDA, digital camera, or cell phone camera. Because all these devise have a limited dynamic range, images captured in real world scenes with high dynamic ranges usually exhibit poor visibility and low contrast, which may make important image features lost or hard to tell by human viewers. In this paper, the efficient color image enhancement method is presented. Experimental result show that the proposed method yields better performance of color enhancement over the previous work for test color images.

  • PDF

The Effect of a Bubble in B nard Convection at Low Rayleigh Number (낮은 Rayleigh값의 B nard Convection 유동장에 주입된 기포의 영향에 관한 연구)

  • Eom, Yong-Gyun;Gwon, Gi-Han
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.12
    • /
    • pp.1879-1886
    • /
    • 2001
  • n a enclosed square cavity occurred B nard convection, the flow phenomena in the surrounding of the bubble attached at the upper cooled solid wall were studied by using a thermo-sensitive liquid-crystal tracer and image processing techniques. This method offers the advantage of measuring the entire flow field in a selected plane within the fluid at a given instant of time in contrast to point by point method like T/C. Quantitative data of the temperature were obtained by applying a colour-image-processing to the visualized image. As the flowing in a bubble, In a bubble size appears the flow phenomena which the direction of flow is reversed in the entire temperature and flow field. The observed phenomena are described with regard to the thermocapillary convection.

Medical Image Data Compression Based on the Region Segmentation (영역분할을 기반으로 한 의료영상 데이타 압축)

  • 김진태;두경수
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.3 no.3
    • /
    • pp.597-605
    • /
    • 1999
  • In this paper, we propose a cardioangiography sequence image coding scheme which use a subtraction between initial image and current frame inserted contrast dye. Stable regions are obtained by the multithreshold and meaningful region is extracted by the images with stable region. The image with meaningful region is classified into contour and texture information. Contour information is coded by contour coding. And texture information is approximated by two-dimensional polynomial function and each coefficients is coded. Experimental results confirm that the sequence of cardioangiography are well reconstructed at the low bit rate (0.02∼0.04 bpp) and high compression ratio.

  • PDF

Haze Scene Detection based on Hue, Saturation, and Dark Channel Distributions

  • Lee, Y.;Yang, Seungjoon
    • International Journal of Advanced Culture Technology
    • /
    • v.8 no.4
    • /
    • pp.229-234
    • /
    • 2020
  • Dehazing significantly improves image quality by restoring the loss of contrast and color saturation for images taken in the presence. However, when applied to images not taken according to the prior information, dehazing can cause unintended degradation of image quality. To avoid unintended degradations, we present a hazy scene detection algorithm using a single image based on the distributions of hue, saturation, and dark channel. Through a heuristic approach, we find out statistical characteristics of the distribution of hue, saturation, and dark channels in the hazy scene and make a detection model using them. The proposed method can precede the dehazing to prevent unintended degradation. The detection performance evaluated with a set of test images shows a high hit rate with a low false alarm ratio. Ultimately the proposed method can be used to control the effect of dehazing so that the dehazing can be applied to wide variety of images without unintended degradation of image quality.

A Study on the Improvement of Image Fusion Accuracy Using Smoothing Filter-based Replacement Method (SFR 기법을 이용한 영상 융합의 정확도 향상에 관한 연구)

  • Yun Kong-Hyun;Sohn Hong-Gyoo
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2006.04a
    • /
    • pp.187-192
    • /
    • 2006
  • Image fusion techniques are widely used to integrate a lower spatial resolution multispectral image with a higher spatial resolution panchromatic image. However, the existing techniques either cannot avoid distorting the image spectral properties or involve complicated and time-consuming decomposition and reconstruction processing in the case of wavelet transform-based fusion. In this study a simple spectral preserve fusion technique: the Smoothing Filter-based Replacement(SFR) is proposed based on a simplified solar radiation and land surface reflection model. By using a ratio between a higher resolution image and its low pass filtered (with a smoothing filter) image, spatial details can be injected to a co-registered lower resolution multispectral image minimizing its spectral properties and contrast. The technique can be applied to improve spatial resolution for either colour composites or individual bands. The fidelity to spectral property and the spatial quality of SFM are convincingly demonstrated by an image fusion experiment using IKONOS panchromatic and multispectral images. The visual evaluation and statistical analysis compared with other image fusion techniques confirmed that SFR is a better fusion technique for preserving spectral information.

  • PDF

Multi-Level Segmentation of Infrared Images with Region of Interest Extraction

  • Yeom, Seokwon
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.16 no.4
    • /
    • pp.246-253
    • /
    • 2016
  • Infrared (IR) imaging has been researched for various applications such as surveillance. IR radiation has the capability to detect thermal characteristics of objects under low-light conditions. However, automatic segmentation for finding the object of interest would be challenging since the IR detector often provides the low spatial and contrast resolution image without color and texture information. Another hindrance is that the image can be degraded by noise and clutters. This paper proposes multi-level segmentation for extracting regions of interest (ROIs) and objects of interest (OOIs) in the IR scene. Each level of the multi-level segmentation is composed of a k-means clustering algorithm, an expectation-maximization (EM) algorithm, and a decision process. The k-means clustering initializes the parameters of the Gaussian mixture model (GMM), and the EM algorithm estimates those parameters iteratively. During the multi-level segmentation, the area extracted at one level becomes the input to the next level segmentation. Thus, the segmentation is consecutively performed narrowing the area to be processed. The foreground objects are individually extracted from the final ROI windows. In the experiments, the effectiveness of the proposed method is demonstrated using several IR images, in which human subjects are captured at a long distance. The average probability of error is shown to be lower than that obtained from other conventional methods such as Gonzalez, Otsu, k-means, and EM methods.

Electrical Impedance Tomography and Biomedical Applications

  • Woo, Eung-Je
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.1-6
    • /
    • 2007
  • Two impedance imaging systems of multi-frequency electrical impedance tomography (MFEIT) and magnetic resonance electrical impedance tomography (MREIT) are described. MFEIT utilizes boundary measurements of current-voltage data at multiple frequencies to reconstruct cross-sectional images of a complex conductivity distribution (${\sigma}+i{\omega}{\varepsilon}$) inside the human body. The inverse problem in MFEIT is ill-posed due to the nonlinearity and low sensitivity between the boundary measurement and the complex conductivity. In MFEIT, we therefore focus on time- and frequency-difference imaging with a low spatial resolution and high temporal resolution. Multi-frequency time- and frequency-difference images in the frequency range of 10 Hz to 500 kHz are presented. In MREIT, we use an MRI scanner to measure an internal distribution of induced magnetic flux density subject to an injection current. This internal information enables us to reconstruct cross-sectional images of an internal conductivity distribution with a high spatial resolution. Conductivity image of a postmortem canine brain is presented and it shows a clear contrast between gray and white matters. Clinical applications for imaging the brain, breast, thorax, abdomen, and others are briefly discussed.

  • PDF

A Single Image Defogging Algorithm Based on Multi-Resolution Method Using Histogram Information and Dark Channel Prior (히스토그램 정보와 dark channel prior를 이용한 다해상도 기반 단일 영상 안개 제거 알고리즘)

  • Yang, Seung-Yong;Yang, Jeong-Eun;Hong, Seok-Keun;Cho, Seok-Je
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.6
    • /
    • pp.649-655
    • /
    • 2015
  • In this paper, we propose a defogging algorithm for a single image. Dark channel prior (DCP), which is a well-known defogging algorithm, can cause halo artifacts on boundary regions, low-contrast defogging images, and requires a large computational time. To solve these problems, we use histogram information with DCP on transmission estimation regions and a multi-resolution method. Local histogram information can reduce the low-contrast problem on a defogging image, and the multi-resolution method with edge information can reduce the total computational time and halo artifacts. We validate the proposed method by performing experiments on fog images, and we confirm that the proposed algorithm is more efficient and superior than conventional algorithms.