Improved Image Quality and Radiation Dose Reduction in Liver Dynamic CT Scan with the Protocol Change (Liver CT 검사에서 프로토콜 변화에 따른 선량 감소와 영상의 질 개선에 관한 연구)

  • Cho, Yu-Jin;Cho, Pyong-Kon
    • Journal of radiological science and technology
    • /
    • v.38 no.2
    • /
    • pp.107-114
    • /
    • 2015
  • The purpose is reducing radiation dose while maintaining of image quality in liver dynamic CT(LDCT) scan, by protocols generally used and the tube voltage set at a low level protocol compared to the radiation dose and image quality. The target is body mass index, 18.5~24 patients out of 40 patients who underwent the ACT(abdominal CT). Group A(tube voltage : 120kVp, SAFIRE strength 1) of 20 people among 40 people, to apply the general abdominal CT scan protocol, group B(tube voltage : 100kVp, apply SAFIRE strength 0~5) was 20 people, set a lower tube voltage. Image quality evaluation was setting a region of interest(ROI) in the liver parenchyma, aorta, superior mesenteric artery (SMA), celiac trunk, visceral fat of arterial phase. In the ROI were compared by measuring the noise, signal to noise ratio(SNR), contrast to noise ratio(CNR), CT number. In addition, qualitative assessments to evaluate two people in the rich professional experience in Radiology by 0-3 points. We compared the total radiation dose, dose length product(DLP) and effective dose, volume computed tomography dose index(CTDIvol). The higher SAFIRE in the tube voltage 100 kVp, noise is reduced, CT number was increased. Thus, SNR and CNR was increased higher the SAFIRE step. Compared with the tube voltage 120kVp, noise, SNR, CNR was most similar in SAFIRE strength 2 and 3. Qualitative assessment SAFIRE strength 2 is the most common SAFIRE strength 2 the most common qualitative assessment, if the tube voltage of 100kVp when the quality of the images better evaluated was SAFIRE strength 1. Dose was reduced from 21.69%, in 100kVp than 120kVp. In the case of a relatively high BMI is not LDCT scan, When it is shipped from the factory tube voltage is set higher, unnecessary radiation exposure when considering the reality that is concerned, when according to the results of this study, set a lower tube voltage and adjust the SAFIRE strength to 1 or 2, the radiation without compromising image quality amount also is thought to be able to be reduced.

A pilot study of half-value layer measurements using a semiconductor dosimeter for intraoral radiography

  • Shun Nouchi;Hidenori Yoshida;Yusaku Miki;Yasuhito Tezuka;Ruri Ogawa;Ichiro Ogura
    • Imaging Science in Dentistry
    • /
    • v.53 no.3
    • /
    • pp.217-220
    • /
    • 2023
  • Purpose: This pilot study was conducted to evaluate half-value layer (HVL) measurements obtained using a semiconductor dosimeter for intraoral radiography. Materials and Methods: This study included 8 aluminum plates, 4 of which were low-purity (less than 99.9%) and 4 high-purity (greater than 99.9%). Intraoral radiography was performed using an intraoral X-ray unit in accordance with the dental protocol at the authors' affiliated hospital: tube voltage, 60 kVp and 70 kVp; tube current, 7 mA; and exposure time, 0.10 s. The accuracy of HVL measurements for intraoral radiography was assessed using a semiconductor dosimeter. A simple regression analysis was performed to compare the aluminum plate thickness and HVL in relation to the tube voltage (60 kVp and 70 kVp) and aluminum purity (low and high). Results: For the low-purity aluminum plates, the HVL at 60 kVp (Y) and 70 kVp (Y) was significantly correlated with the thickness of the aluminum plate (X), with Y=1.708+0.415X (r=0.999, P<0.05) and Y=1.980+0.484X (r=0.999, P<0.05), respectively. Similarly, for the high-purity aluminum plates, the HVL at 60 kVp (Y) and 70 kVp (Y) was significantly correlated with the plate thickness(X), with Y=1.696+0.454X (r=0.999, P<0.05) and Y=1.968+0.515X (r=0.998, P<0.05), respectively. Conclusion: This pilot study examined the relationship between aluminum plate thickness and HVL measurements using a semiconductor dosimeter for intraoral radiography. Semiconductor dosimeters may prove useful in HVL measurement for purposes such as quality assurance in dental X-ray imaging.

Analysis on the V-I Curve of ZnO:As/ZnO:Al homo-junction LED (ZnO:As/ZnO:Al homo-junction LED의 V-I 특성 분석)

  • Oh, Sang-Hyun;Jeong, Yun-Hwan;Liu, Yan-Yan;Park, Choon-Bae
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.410-411
    • /
    • 2007
  • To investigate the ZnO LED which are interested in the next generation of short wavelength LEDs and Lasers, the ZnO thin films were deposited by RF magnetron sputtering system. The p-type ZnO thin film, fabricated by means of the ampoule-tube method, was used to make the ZnO p-n junction, and its characteristics was analyzed. The ampoule-tube method was used to make the p-type ZnO based on the As diffusion, and the hall measurement was used to confirm that the p-type is formed. the current-voltage characteristics of the ZnO p-n junction were measured to confirm the rectification characteristics of a typical p-n junction and the low leakage voltage characteristics. Analysis of ZnO LED V-I curve will provide a very useful technology for producing the UV ZnO LED and ZnO-based devices.

  • PDF

Performance Evaluation of Automatic Segmentation based on Deep Learning and Atlas according to CT Image Acquisition Conditions (CT 영상획득 조건에 따른 딥 러닝과 아틀라스 기반의 자동분할 성능 평가)

  • Jung Hoon Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.3
    • /
    • pp.213-222
    • /
    • 2024
  • This study analyzed the volumes generated by deep learning and atlas-based automatic segmentation methods, as well as the Dice similarity coefficient and 95% Hausdorff distance, according to the conditions of conduction voltage and conduction current in computed tomography for lung radiotherapy. The first result, the volumes generated by the atlas-based smart segmentation method showed the smallest volume change as a function of the change in tube voltage and tube current, while Aview RT ACS and OncoStudio using deep learning showed smaller volumes at tube currents lower than 100 mA. The second result, the Dice similarity coefficient, showed that Aview RT ACS was 2% higher than OncoStuido, and the 95% Hausdorff distance results also showed that Aview RT ACS analyzed an average of 0.2-0.5% higher than OncoStudio. However, the standard deviation of the respective results for tube current and tube voltage is lower for OncoStudio, which suggests that the results are consistent across volume variations. Therefore, caution should be exercised when using deep learning-based automatic segmentation programs at low perfusion voltages and low perfusion currents in CT imaging conditions for lung radiotherapy, and similar results were obtained with conventional atlas-based automatic segmentation programs at certain perfusion voltages and perfusion currents.

Fabrication and Characteristics of Anode-supported Tubular Solid Oxide Fuel Cell (연료극 지지체식 원통형 고체산화물 연료전지의 제조 및 특성)

  • Song, Keun-Sik;Song, Rak-Hyun;Ihm, Young-Eon
    • Korean Journal of Materials Research
    • /
    • v.12 no.9
    • /
    • pp.691-695
    • /
    • 2002
  • A low temperature anode-supported tubular solid oxide fuel cell was developed. The anode-supported tube was fabricated using extrusion process. Then the electrolyte layer and the cathode layer were coated onto the anode tube by slurry dipping process, subsequently. The anode tube and electrolyte were co-fired at $140^{\circ}C$, and the cathode was sintered at $1200^{\circ}C$. The thickness and gas permeability of the electrolyte depended on the number of coating and the slurry concentration. Anode-supported tube was satisfied with SOFC requirements, related to electrical conductivity, pore structure, and gas diffusion limitations. At operating temperature of $800^{\circ}C$, open circuit voltage of the cell with gastight and dense electrolyte layer was 1.1 V and the cell showed a good performance of 450 mW/$\textrm{cm}^2$.

Performance Test of 200-MW Pulse Transformer for 80-MW Klystron Load (80-MW 클라이스트론 부하용 200-MW 펄스 트랜스포머의 성능시험)

  • Jang, S.D.;Oh, J.S.;Son, Y.G.;Cho, M.H.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2167-2169
    • /
    • 1999
  • A pulse transformer producing pulses with the peak power of 200-MW (400 kV 500 A at load side with $4.4{\mu}s$ flat-top) is required to drive the 80-MW pulsed klystron in the PLS linac. We have designed and manufactured the high power pulse transformer with 1 : 17 turn ratio. Its primary functions are to match the impedance of klystron tube to the modulators, and to provide step-up of the voltage. To obtain a fast rise time of the pulse voltage. Low leakage inductance and low distributed capacitance design is very important. In this paper, we discuss the equivalent circuit analysis of the pulse transformer, and present the full power performance test results of pulse transformer.

  • PDF

The effects of voltage of x-ray tube on fractal dimension and anisotropy of diagnostic image

  • Baik, Jee-Seon;Lee, Sam-Sun;Park, Kwan-Soo;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Choi, Soon-Chul
    • Imaging Science in Dentistry
    • /
    • v.37 no.4
    • /
    • pp.211-215
    • /
    • 2007
  • Purpose: The purpose of this study was to evaluate the effect of the kV on fractal dimension of trabecular bone in digital radiographs. Materials and Methods: 16 bone cores were obtained from patients who had taken partial resection of tibia due to accidents. Each bone core along with an aluminum step wedge was radiographed with an occlusal film at 0.08 sec and with the constant film-focus distance (32 cm). All radiographs were acquired at 60, 75, and 90 kV. A rectangular ROI was drawn at medial part, distal part, and the bone defect area of each bone core image according to each kV. The directional fractal dimension was measured using Fourier Transform spectrum, and the anisotropy was obtained using directional fractal dimension. The values were compared by the repeated measures ANOVA. Results : The fractal dimensions increased along with kV increase (p < 0.05). The anisotropy measurements did not show statistically significant difference according to kV change. The fractal dimensions of the bone defect areas of the bone cores have low values contrast to the non-defect areas of the bone cores. The anisotropy measurements of the bone defect areas were lower than those of the non-defect areas of the bone cores, but not statistically significant. Conclusion: Fractal analysis can notice a difference of a change of voltage of x-ray tube and bone defect or not. And anisotropy of a trabecular bone is coherent even with change of the voltage of x-ray tube or defecting off a part of bone.

  • PDF

Establishment of Quality Control System for Angiographic Unit (IVR장치의 성능 평가 기준 개발)

  • Kang, Byung-Sam;Son, Jin-Hyun;Kim, Seung-Chul
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.1
    • /
    • pp.236-244
    • /
    • 2011
  • Recently, the number of interventional procedures has increased dramatically as an alternative of invasive surgical procedure. The need for the quality control program of the angiographic units has also increased, because of concerns about the increased patient dose and the importance of image quality of angiographic units for the successful procedures. The purpose of this study was to propose an optimal guideline for the quality control program of the angiographic units. We reviewed domestic and international standards about medical imaging system and we evaluated the quality of 61 angiographic units in Korea with the use of NEMA 21 phantom. According to the results of our study, we propose a guideline for the quality control program of the angiographic units. Quality control program includes tube voltage test, tube current test, HVL test, image-field geometry test, spatial resolution test, low-contrast iodine detectability test, wire resolution test, phantom entrance dose test. Proposed reference levels are as follows: PAE < $\pm$ 10% in tube voltage test, PAE < $\pm$ 15% in tube current test, minimum 2.3 mmAl at 80 kVp in HVL test, minimum 'acceptable' level at image-field geometry test, 0.8 lp/mm for detector size of 34-40cm, 1.0 lp/mm for detector size of 28-33cm, 1.2 lp/mm for detector size of 22-27cm in spatial resolution test, minimum 200mg/cc in low contrast iodine detectability test, phantom entrance dose should be under 10R/min, 0.012 inch wire should be seen at static wire resolution test, and 0.022 inch wire should be seen at moving wire resolution test.

Piezoelectric-Actuated Polydimethylsiloxane(PDMS) Micropump with Diffusers (압전 구동 방식의 Polydimethylsiloxane(PDMS) 마이크로 펌프)

  • 김진호;김영호;김용상
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.10
    • /
    • pp.487-491
    • /
    • 2003
  • The low-cost, simple structured micropump which is actuated by piezoelectric-discs, is fabricated with polydimethylsiloxane (PDMS) and the performances of the micropump, such as pump rate and backpressure, are characterized. The PDMS micropump with diffusers instead of passive check valves as a flow-rectifying element was fabricated. The deflection of glass diaphragm measured by atomic force microscope (AFM) is about 0.4$\mu\textrm{m}$ when applying a 150V square wave voltage at 300Hz across a 300${\mu}\ell$ thick piezoelectric disc. While the square wave driving voltage is applied to the piezoelectric disc of the actuator, the flow rate is measured by fluid displacement variation of the outlet tube. The flow rate of micropump increases with enhancing the applied voltage due to the increase of diaphragm deflection. The flow rate and the backpressure of the micropump with diffusers are about 32.9${\mu}\ell$/min and 173Pa respectively for the above mentioned deflection conditions.

Pressure drop characteristics of concentric spiral corrugation cryostats for a HTS power cable considering core surface roughness

  • Youngjun Choi;Seokho Kim
    • Progress in Superconductivity and Cryogenics
    • /
    • v.25 no.2
    • /
    • pp.19-24
    • /
    • 2023
  • Recently, interest in renewable energy such as solar and wind power has increased as an alternative to fossil fuels. Renewable energy sources such as large wind farms require long-distance power transmission because they are located inland or offshore, far from the city where power is required. High-Temperature Superconducting (HTS) power cables have more than 5 times the transmission capacity and less than one-tenth the transmission loss compared to the existing cables of the same size, enabling large-capacity transmission at low voltage. For commercialization of HTS power cables, unmanned operation and long-distance cooling technology of several kilometers is essential, and pressure drop characteristic is important. The cryostat's spiral corrugation tube is easier to bend, but unlike the round tube, the pressure drop cannot be calculated using the Moody chart. In addition, it is more difficult to predict the pressure drop characteristics due to the irregular surface roughness of the binder wound around the cable core. In this paper, a CFD model of a spiral corrugation tube with a core was designed by referring to the water experiments from previous studies. In the four cases geometry, when the surface roughness of the core was 10mm, most errors were 15% and the maximum errors were 23%. These results will be used as a reference for the design of long-distance HTS power cables.