• Title/Summary/Keyword: Low temperature test

Search Result 1,931, Processing Time 0.035 seconds

Evaluation of Low Temperature Properties in 18Cr Ferritic Stainless Steel Welds (18Cr 페라이트계 스테인리스강의 용접부 저온 특성 평가)

  • Lee, Won-Bae;U, In-Su;Eom, Sang-Ho;Lee, Jong-Bong
    • Proceedings of the KWS Conference
    • /
    • 2007.11a
    • /
    • pp.138-140
    • /
    • 2007
  • This study aimed to evaluate the low temperature properties of the 18Cr ferritic stainless steel weld. Applied welding methods were LB(Laser Beam) and GTA(Gas Tungsten Arc) welding to compare the different low temperature properties of the welds. Low temperature properties were evaluated by the Charpy impact, Erichsen and Expansion test at low temperature. LB weld showed superior low temperature properties in the cases of the Charpy impact test and expansion test at low temperature, while GTA weld showed a superior low temperature property in the case of Erichsen test at low temperature. The different low temperature properties with test methods are still under analysis and may be due to different crack path depending on the microstructure, test speed and stress concentration during test.

  • PDF

A Study on the Test Standards at Low Temperature of Rubber Suspension Components of Railway Vehicle (철도차량 고무 현가부품의 내한성 시험기준연구)

  • Yoon, Tae-Ho;Jang, Seung-Ho;Choi, Byoung-Il;Lee, Chan-Woo;Na, Hee-Seung
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.372-376
    • /
    • 2004
  • In this paper, the standard test methods at low temperature of rubber suspension components of railway vehicle are investigated and reviewed. In order to connect the TKR(Trans-Korean Railway)-TSR(Trans-Siberian Railway), it is necessary to evaluate the performance of rubber suspenion components of railway vehicle. In the current Korean Standard, the test method at low temperature of railway vehilce components and the test method of rubber bellows of air spring are specified. But, the specified test temperature is higher than the the operating temperature of TSR railway. So, the in-depth research for the test method and performance evaluation technique of rubber suspension component at low temperature is necessary and current KS code should be adjusted.

  • PDF

A Study on the Tailoring of High / Low Temperature Test for KT-1 Trainer Export Version (수출형 KT-1 훈련기 고/저온 환경시험절차 적합화 연구)

  • Kim, Jin Seog
    • Journal of the Korean Society of Systems Engineering
    • /
    • v.16 no.2
    • /
    • pp.78-86
    • /
    • 2020
  • The environmental tests are one of the key branches of the reliability tests. The purpose of the high/low environmental test of KT-1 Export Version Trainer is not only based on meeting the compliance of the reliability, customer satisfaction, but also for the expansion of its export. Amongst many existing environmental tests, the high and low temperature tests are considered as the two most important tests. The tests are considered and tailored to the high and low temperature methods of MIL-STD-810H. This paper proposes the tailoring processes and the results of High/Low temperature conditions, test procedures, and test profiles for the aircraft. Additionally, this paper is described by considering the view of MIL-STD-810H.

Low Temperature Test of HWR Cryomodule

  • Kim, Heetae;Kim, Youngkwon;Lee, Min Ki;Park, Gunn-Tae;Kim, Wookang
    • Applied Science and Convergence Technology
    • /
    • v.25 no.3
    • /
    • pp.47-50
    • /
    • 2016
  • Low temperature test for half-wave resonator (HWR) cryomodule is performed at the superfluid helium temperature of 2 K. The effective temperature is defined for non-uniform temperature distribution. Helium leak detection techniques are introduced for cryogenic system. Experimental set up is shown to make the low temperature test for the HWR cryomodule. The cooldown procedure of the HWR cryomodule is shown from room temperature to 2 K. The cryomodules is precooled with liquid nitrogen and then liquid helium is supplied to the helium reservoirs and cavities. The pressure of cavity and chamber are monitored as a function of time. The vacuum pressure of the cryomodule is not increased at 2 K, which shows leak-tight in the superfluid helium environment. Static heat load is also measured for the cryomodule at 2.5 K.

A Study on Improvement of the low temperature flex resistance test method about high waterproof materials (고기능성 투습방수 소재의 저온굴곡 시험방법 개선 연구)

  • Lee, Minhee;Moon, Sunjeong;Ko, Hyeji;Hong, Seongdon
    • Journal of Korean Society for Quality Management
    • /
    • v.46 no.3
    • /
    • pp.425-440
    • /
    • 2018
  • Purpose: This study is aimed at developing of the flex resistance testing process at low temperature with the waterproof fabric to suit the military environment, and is designed to fit for the purpose of the waterproof materials in order to optimize the test method by finding out matters to improve from existing the test method and through previous studies. Methods: The test method, which has been applied to flex resistance of existing water-repellent materials, was improved and consequently, differentiated test results could be obtained according to the test temperature, sample size, and flexing method. Results: The testing of the total of 8 samples revealed that performance of the military requirement could hardly be met just by presenting the materials or 2~3 layers when the quality criteria for high functional water repellent fabrics were applied. PTFE(Polytetrafluoroethylene) is preferred to PU(Polyurethane) to be used in the extremely low-temperature environment, but durability under the low-temperature environment may be varied depending on film thickness or laminating technique even if the materials of waterproof films are identical. Therefore, in addition to the material or texture, the test method capable of reflecting durability under the low-temperature environment shall be suggested, and the newly designed test method proposed in this study was shown to suggest differentiated quality criteria by the material. Conclusion: The water resistance measurement and the test method following flex resistance with expanded range of flex will enable the differentiable test of the samples according to the number of repetition. This study is meaningful in that it suggests a differentiable test method capable of establishing a basis of deciding suitable material when selecting military goods made of water repellent material by properly improving the test method.

A Study on the Hot Spot Temperature in 154kV Power Transformers

  • Kweon, Dong-Jin;Koo, Kyo-Sun;Woo, Jung-Wook;Kwak, Joo-Sik
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.3
    • /
    • pp.312-319
    • /
    • 2012
  • The life of a power transformer is dependent on the life of the cellulose paper, which influenced by the hot spot temperature. Thus, the determination of the cellulose paper's life requires identifying the hot spot temperature of the transformer. Currently, however, the power transformer uses a heat run test is used in the factory test to measure top liquid temperature rise and average winding temperature rise, which is specified in its specification. The hot spot temperature is calculated by the winding resistance detected during the heat run test. This paper measures the hot spot temperature in the single-phase, 154kV, 15/20MVA power transformer by the optical fiber sensors and compares the value with the hot spot temperature calculated by the conventional heat run test in the factory test. To measure the hot spot temperature, ten optical fiber sensors were installed on both the high and low voltage winding; and the temperature distribution during the heat run test, three thermocouples were installed. The hot spot temperature shown in the heat run test was $92.6^{\circ}C$ on the low voltage winding. However, the hot spot temperature as measured by the optical fiber sensor appeared between turn 2 and turn 3 on the upper side of the low voltage winding, recording $105.9^{\circ}C$. The hot spot temperature of the low voltage winding as measured by the optical fiber sensor was $13.3^{\circ}C$ higher than the hot spot temperature calculated by the heat run test. Therefore, the hot spot factor (H) in IEC 60076-2 appeared to be 2.0.

Ground High/Low Temperature Test for FA-50 Aircraft (FA-50 경공격기 전기체 지상 고/저온시험)

  • Ahn, Jong Hoon;Kim, Tae Ho;Woo, Seung Cheol;Cho, Young Kyun;Kim, Do Wan
    • Journal of the Korean Society of Systems Engineering
    • /
    • v.6 no.1
    • /
    • pp.41-46
    • /
    • 2010
  • The ground high/low temperature test objective is to check the normal ground operation of FA-50 aircraft in the extreme ground ambient conditions. The aircraft was exposed in climatic conditions of the basic climatic category according to the MIL-HDBK-310. For verified normal operation in the extreme high temperature, the high temperature test was performed in the hot regional type conditions and accentuated solar radiation heat. This test was performed at the test chamber in ADD where is in Haemi. This paper was described about the test procedure of FA-50 high/low temperature including preparation, testing and results.

  • PDF

A study on the characteristic of adhesion on the low temperature concrete of self adhesive waterproofing sheet using interface leakage test. (계면 누수를 통한 자착형 방수시트의 저온 부착 특성에 관한 연구)

  • Choi, Su-Young;Kim, Meong-Ji;Lee, Jung-Hoon;Choi, Sung-Min;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.05a
    • /
    • pp.234-235
    • /
    • 2014
  • Recently, waterproof construction used to self adhesive waterproofing sheet in the actual field in winter for reduce cost and term. However self adhesive waterproofing sheet's quality is declined in low temperature condition. So, this study was to confirm on the low temperature condition of concrete substrate effecting the adhesion of self adhesion waterproofing sheet using interface leakage test. As a result of this study, self adhesion waterproofing sheet must not be used at temperature below 5℃. Also, adhesion between waterproofing sheet and concrete is declined in low temperature.

  • PDF

A study on the Tailoring of Environmental Requirements for XKT-1T Aircraft (XKT-1T 항공기 환경 요구사항 적합화 연구)

  • Kim, Jin Seog
    • Journal of the Korean Society of Systems Engineering
    • /
    • v.17 no.1
    • /
    • pp.97-106
    • /
    • 2021
  • The purpose of the study on the tailoring of environmental requirements for KT-1 Export Version(XKT-1T) aircraft is not only based on meeting the compliance of the environmental reliability, customer satisfaction, but also for the expansion of its export. This paper proposes the environmental requirements tailoring processes and High/Low temperature conditions, test procedures, and the results of test profiles for the aircraft. Amongst many existing environmental requirements, the temperature requirements are considered as the most basic and the most important environmental requirements. The High/Low temperature tests are considered and tailored to the high and low temperature methods of MIL-STD-810.

Properties of Low Heat Portland Cement Concrete by Changing Temperature of Aggregate (골재의 온도 변화에 따른 저발열 포틀랜드 시멘트 콘크리트의 특성)

  • Cho, Yong-Chin;Park, Kwang-Su;Shin, Su-Gyun;Won, Jong-Pil
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.46 no.4
    • /
    • pp.49-55
    • /
    • 2004
  • Properties of concrete using low heat portland cement is different from using ordinary portland cement and temperature of aggregate can be expected to have an important influence on its properties. In this study, experiment by setting up 5 levels (40, 30, 20, 4, $-2^{\circ}C$) by temperature of aggregate for evaluation properties of concrete using low heat portland cement was conducted. The experiments include slump test, air content test, change of slump, change of air content and compressive strength of concrete test. As the result of experiments, slump and air content was decreased by increasing temperature of aggregate. But it was not exceeding it's limit. Change of slump and air content was rapidly decrease by decreasing temperature of aggregate. At early age, compressive strength was influenced by the temperature of aggregate.