• Title/Summary/Keyword: Low temperature concrete

Search Result 391, Processing Time 0.026 seconds

콘크리트 교면 도막 방수재의 양생기간 및 시험체 온도에 따른 접착 특성 (Adhesive Strength Characteristics of the Curing Time and Test Temperature for Liquid Waterproofing Membrane in Concrete Bridge Deck)

  • 조병영;박동협;신주재;김영근
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.553-556
    • /
    • 2003
  • This study is analyzed about the factor of adhesive strength characteristics, curing time, asphalt application, test temperature which are liquid waterproofing membrane of rubber-asphalt and chloroprene-rubber type for concrete bridge deck. According to the results, curing time is shorter, adhesive strength is less in chloroprene-rubber type. And also chloroprene-rubber and rubber-asphalt type are showed high adhesive strength in low temperature.

  • PDF

시트양생 및 파이프 쿨링에 의한 매스콘크리트 구조물의 온도제어 (Temperature Control of Mass-Concrete Structure with Pipe Cooling or Sheet Curing.)

  • 차홍윤;김은경;김래현;신치범
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1995년도 봄 학술발표회 논문집
    • /
    • pp.263-267
    • /
    • 1995
  • The usual methods for the temperature control of mass-concrete structures include the use of low-heat cement, pre-cooling, post-cooling, or sheet curing. In order to control the heat of hydration during the construction of mass-concrete structures, the combination of the above methods is commonly employed. For the construction of mass-concrete structures such as massive pier or anchor, it is necessary to control the curing temperature with pipe cooling. In this study, the method of analysis on the effect of pipe of was proposed to prevent the thermal cracking due to heat of hydration In addition the effect of covering the concrete surface with blanket insulation was investigated. The results of the present study may be useful for the prediction of curing temperature of mass-concrete structures and the reasonable construction management.

  • PDF

적산온도방식에 의한 콘크리트 강도증진해석에 있어 한계온도범위의 검토 (AnInvestigation on the Limit Temperature for Applying Maturity Method in Analyzing Strength Development of Concrete)

  • 한민철;전층근;이건철;윤기원;한천구
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1997년도 가을 학술발표회 논문집
    • /
    • pp.111-116
    • /
    • 1997
  • In this paper, the limit temperature for applying maturity method are discussed. 4 kinds of W/C in combination of 7kinds of curing temperature are selected as experimental parameters. According to the experimental results, high curing temperature and low W/C gain in strength rapidly. And maturity rule can be applied less than $30^{\cire}C$ in W/C of 30~60% in the conditions of this experiment.

  • PDF

Temperature effects on brittle fracture in cracked asphalt concretes

  • Ayatollahi, Majid-Reza;Pirmohammad, Sadjad
    • Structural Engineering and Mechanics
    • /
    • 제45권1호
    • /
    • pp.19-32
    • /
    • 2013
  • Cracking at low temperatures is one of the frequently observed modes of failure in asphalt concretes. In this investigation, fracture tests were performed on cracked asphalt concrete subjected to pure mode I and pure mode II loading at different subzero temperatures. An improved semi-circular bend (SCB) specimen containing a vertical crack was used to conduct the experiments. The SCB specimens produced from the gyratory compacted cylindrical samples were compressively loaded, and critical stress intensity factors, $K_{If}$ and $K_{IIf}$, were then calculated using peak loads obtained from the tests. The experimental results showed that with decreasing the temperature, mode I and mode II critical stress intensity factors increased first but below a certain temperature they both decreased. It was also found that at a fixed temperature, the mode II fracture resistance of the asphalt concrete was higher than its mode I fracture resistance.

온도균열 저감공법을 복합사용한 매스콘크리트의 현장적용 (Field Application of the Mass Concrete Utilizing Combined Method for Temperature Crack Reduction)

  • 한상윤;이충섭;백대현;장덕배;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2010년도 춘계 학술논문 발표대회 1부
    • /
    • pp.37-39
    • /
    • 2010
  • In this study, with new office construction site of S Construction company as subject, to solve all the problems according to reduced hydration heat and temperature crack of mass concrete used mat foundation and placing time difference, low heat combination of coarse particle cement and fly-ash and setting time difference applied AE water reducing agent, and to prevent the early frost damage caused by low outdoor temperature, a heat insulation method using double bubble sheet was conducted. As a result, it was found that hydration heat and setting time difference was reduced by applying a low heat combination and setting time difference construction method, and that the high insulation capability of the double bubble sheet was able to not only prevent the early frost damage but also reduce temperature difference between the central part and the upper part of mass concrete.

  • PDF

양생조건에 따른 콘크리트 강도 특성에 관한 실험적 연구 (A Experimental Study on the Properties of Concrete Strength According to Curing Condition)

  • 정원섭;김강식;박재우;노재명
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(II)
    • /
    • pp.441-444
    • /
    • 2005
  • Our country has experienced variations in temperature as belong to the area of the continental climate that shows four significant seasons. These occur immense difficulty on the period, cost, quality of construction. As the hydration of cement processes, the strength of concrete is developed. In order to improve the quality of concrete, various conditions including temperature and humidity should be maintained appropriately and concrete itself should be cured sufficiently. In the early age, the strength of concrete is developed remarkably. However, the hydration is accelerated too much in high temperature or delayed too much in low temperature, so the quality can be changed and It can fail to get the objective strength. This paper aims to offer the data, necessary to the quality control handbook.

  • PDF

저열 포틀랜드 시멘트를 사용한 댐 콘크리트의 특성에 관한 연구 (Study on the Properties of Dam Concrete Using Low Heat Portland Cement)

  • 손영준;하재담;엄태선;이종열;김태홍
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계 학술발표회 논문집(II)
    • /
    • pp.445-448
    • /
    • 2006
  • In order to control the temperature crack of massive dam concrete, the selection of appropriate materials like binder, aggregates etc., is essential. To select the optimal mix proportion, ordinary portland cement(Type I) plus 25% of fly ash and low heat portland cement(Type IV) are used as binder, and 80mm of coarse aggregates are used to reduce the amount of binder and compare the compressive strength, hydration temperature and crack index. The results of this study are as following. 1. The strength of Type IV cement is advantageous on the long-term age. 2. According to the temperature measured on mock-up$(1.5m{\times}1.5m{\times}1.5m)$, and realized the thermal analysis, the Type IV cement carried out advantageous to control the thermal crack.

  • PDF

인천 LNG 지하탱크 Bottom 의 온도균열제어 (Thermal Crack Control about of LNG in Inchon)

  • 구본창;하상욱;김동석;하재담;이종열;권영호
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 봄 학술발표회 논문집
    • /
    • pp.291-296
    • /
    • 2000
  • The crack of concrete induced by the heat of hydration is s serious problem, particularly in concrete structures such as bridge piers. thick walls, box type walls, mat-slab of nuclear reactor building, dams of foundations of high rise buildings, etc. As a result of the temperature rise and restriction condition of foundation, the thermal stress which way induce the cracks can occur. Therefore the various techniques of the thermal stress control in massive concrete have been widely used. One of them is prediction of the thermal stress, besides low-heat cement which mitigates the temperature rise, design change which consider steel bar reinforcement, operation control and so on. In this study, firstly it introduce the thermal cracks control technique by employing low-heat cement concrete, thermal stress analysis, Secondly it shows the application of the cracks control technique like the bottom of No.15,16 Underground LNG Tank in Inchon.

  • PDF

오피스텔 대형 기초매트의 온도해석을 통한 온도균열제어 (Thermal Crack Control of Massive Foundation Mat of Office-tel Using Thermal Analysis)

  • 김태홍;하재담;김동석;이종열
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 가을 학술발표회 논문집(II)
    • /
    • pp.1181-1186
    • /
    • 2000
  • The crack of concrete induced by the heat of hydration is a serious problem, particularly in concrete structures such as biers, thick walls, box type walls, mat-slab of nuclear reactor buildings, dams or foundations of high rise buildings, etc.. As a result of the temperature rise and restriction condition of foundation, the thermal stress which may induce the cracks can occur. Therefore the various techniques of the thermal stress control in massive concrete have been widely used. One of them is prediction of the thermal stress, besides low-heat cement which mitigates the temperature rise, design change which considers steel bar reinforcement, operation control and so on. In this study, firstly it introduce the thermal cracks control technique by employing low-heat cement concrete, thermal stress analysis considering season. Secondly it shows the application of the cracks control technique like block placement.

인천 LNG 지하탱크 #219 Bottom Slab시공 및 온도균열 안정성 평가 (Construction and Evaluation of Thermal Crack Stability about Bottom Slab of the #219 LNG Underground Tank in Incheon)

  • 손영준;하재담;엄태선;이종열;박종식
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 추계 학술발표회 논문집
    • /
    • pp.689-692
    • /
    • 2006
  • The crack of concrete induced by the heat of hydration is a serious problem, particularly in massive concrete structures. In order to control the temperature crack of massive concrete, the selection of appropriate materials like low heat cement, mixture materials, etc. is essential. In tills study, mix proportion using low heat portland cement and lime stone powder was designed and the best mix proportion, B-1, was selected. When bottom slab of the #219 LNG tank in Incheon was constructed, concrete temperature was measured. And thermal stress was analyzed about bottom slab of the LNG tank. As results of the thermal analysis, crack index was 1.60 in bottom slab and satisfied with construction specifications(over 1.0).

  • PDF