• Title/Summary/Keyword: Low operation voltage

Search Result 1,030, Processing Time 0.03 seconds

A Special Protection Scheme Against a Local Low-Voltage Problem and Zone 3 Protection in the KEPCO System

  • Yun, Ki-Seob;Lee, Byong-Jun;Song, Hwa-Chang
    • Journal of Electrical Engineering and Technology
    • /
    • v.2 no.3
    • /
    • pp.294-299
    • /
    • 2007
  • This paper presents a special protection scheme, which was established in the KEPCO (Korea Electric Power Corporation) system, against a critically low voltage profile in a part of the system after a double-circuit tower outage. Without establishing the scheme, the outage triggers the operation of a zone 3 relay and trips the component. This sequence of events possibly leads to a blackout of the local system. The scheme consists of an inter-substation communication network using PITR (Protective Integrated Transmitter and Receiver) for acquisition of the substations' data, and under-voltage load shedding devices. This paper describes the procedure for determining the load shedding in the scheme and the experiences of the implementation.

Characteristic Experimental of Low Voltage Three phase Diode Rectifier Circuit (저전압 3상 다이오드 정류회로의 특성 실험)

  • Suh K.Y.;Kim Y.M.;Mun S.P.;Kim J.Y.;Lee H.W.
    • Proceedings of the KIPE Conference
    • /
    • 2001.12a
    • /
    • pp.89-92
    • /
    • 2001
  • In conventional three-phase rectifiers, it was necessary to use a transformer to obtain low output voltage. In this paper, we propose a characteristic experimental of three-phase diode rectifiers circuit that achieves low voltage by using a very simple circuit configuration that does not have a transformer and does not need any complex control. We also describe the operation principle of the proposed circuit, and der?ive a theoretical formula for its current waveform. On the basis these theoretical values with experimentally obtained input output current characteristics, current amplification factor, and output voltage characteristics, allowed us to confirm the soundness of our theoretical analyses.

  • PDF

Low-Voltage Current-Sensing CMOS Interface Circuit for Piezo-Resistive Pressure Sensor

  • Thanachayanont, Apinunt;Sangtong, Suttisak
    • ETRI Journal
    • /
    • v.29 no.1
    • /
    • pp.70-78
    • /
    • 2007
  • A new low-voltage CMOS interface circuit with digital output for piezo-resistive transducer is proposed. An input current sensing configuration is used to detect change in piezo-resistance due to applied pressure and to allow low-voltage circuit operation. A simple 1-bit first-order delta-sigma modulator is used to produce an output digital bitstream. The proposed interface circuit is realized in a 0.35 ${\mu}m$ CMOS technology and draws less than 200 ${\mu}A$ from a single 1.5 V power supply voltage. Simulation results show that the circuit can achieve an equivalent output resolution of 9.67 bits with less than 0.23% non-linearity error.

  • PDF

A High Density Memory Device for Next Generation Low-Voltage and High-Speed Operations (차세대 저 전압, 고속 동작 요구에 대응하는 대용량 메모리의 개발)

  • 윤홍일;이현석;유형식;천기철
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.3-5
    • /
    • 2000
  • 1.8V,4Gb DDR SDRAM설계 및 제작을 수행하였다. DRAM동작 시 발생하는 Bit Line간 CouplingNoise를 보상하기 위한 Twisted Open Bit Line 구조를 제안하였다. Low Voltage Operation으로 인한 Bit Line Sense Amplifier 의 동작 저하를 보상하기 위한 BL S/A Pre-Sensing 방식 및 Reference Bit Line Voltage Calibration 구조를 제안하였다. Chip면적 증가로 인한 동작속도 감소의 보상을 위해 Repeater Driver 구조를 Core 및 Periphery Circuit에 적용하여 동작 대비 Chip 면적의 증가를 최소화 하도록 하였다.

  • PDF

Control of Booster Output Voltage in Fuel Cell Power Plant (연료전지발전용 부스터의 출력전압제어 연구)

  • Han, Soo-Bin;Jung, Bong-Man;Shin, Dong-Ryul;Choi, Soo-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.1038-1040
    • /
    • 1992
  • Booster is used widely as one of the step-up DC/DC power converter in power conversion process for fuel cell power plant which have the electrical characteristic of the high current density and low cell voltage. In view of control system, booster can be unstable when it is operated in broad operation range because the transfer function of booster has zero in right half plane of s-domain. So for reliable operation, controller must make the system stable in whole working range. In this paper, the two control method such as digital PID control and fuzzy control is studied for booster output voltage regulation in fuel cell plant. The design procedure of PID control and fuzzy control is described. And the experiment of designed controller action is performed in various operation points for controller performance test.

  • PDF

A Study on the Design of Step Up DC-DC Converter and Parallel Operation (승압형 DC-DC 컨버터의 설계 및 병렬운전에 관한 연구)

  • 서광덕;홍찬욱;설승기;박민호
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.41 no.6
    • /
    • pp.579-587
    • /
    • 1992
  • This paper is to study on the step-up DC-DC converter for power system which yields output characteristics of low voltage and high current, such as fuel cell generation system. DC-AC-DC scheme is suggested for high ratio of voltage conversion. Three phase MOSFET-SPWM inverter is adopted for intermediate AC conversion and inverter output frequency is chosen at 400[Hz] in order to reduce the size of magnetic circuit and DC filter. Since control strategy which combines voltage controller with current controller in parallel is used, good output performance is obtained both in steady state and in transient state like load variation, not only in single unit operation but also in parallel operation.

Commutation Performance of Current Source Converters fed Switched Reluctance Motors (스위치드 리럭턴스 전동기 구동 전류형 컨버터의 전류특성)

  • Jang, Do-Hyun;Choe, ㅍ;Kim, Ki-Su;Jeong, Seon-Ung
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.1 no.1
    • /
    • pp.38-46
    • /
    • 1996
  • The commutation operation of the current source converter for switched reluctance motor drives is analyzed in this paper. The commutation operation in the current source converter consists of two modes. At turn-off of phase switch, the phase current decreases sinusoidally, and the sum of two phase currents during commutation period is constant. At this time, the capacitor voltage increases quickly with changing polarity and decreases slowly when another phase switches turn on or off. Frequency of step-down DC chopper in the current source converter is low because of the dump such as BJTs and GTOs are possible as phase switches instead of Power MOSFET and IGBTS. They may result in reductions of conduction losses and manufacturing cost in the current source converter comparing to the voltage source converter of SRM.

  • PDF

A Novel Two-Stage Power Converter suitable for 1MHz-LDC of Electric Vehicles. (전기자동차용 1MHz LDC에 적합한 새로운 2단계 전력변환기)

  • Tuan, Tran Manh;Choi, Woojin
    • Proceedings of the KIPE Conference
    • /
    • 2018.11a
    • /
    • pp.51-53
    • /
    • 2018
  • The Low Voltage DC-DC converters (LDCs) of the Electric Vehicles require high power density and high efficiency operation over the wide range of load and input voltage variations. This paper introduces a novel topology which combines three 1 MHz Half-Bridge (HB) LLC resonant converters and an Inverting Buck-Boost (IBB) converter to adjust the output voltage without frequency modulation. The switching frequency of the proposed converter is fixed at 1MHz to achieve a constant frequency operation for the resonant converter. In the proposed topology GaN FETs and planar transformers are employed to optimize the converter operation at high frequency. A 1 MHz/1.8 kW prototype converter is built to verify the feasibility and the validity of the proposed LDC topology.

  • PDF

Inorganic ferroelectric materials for LC alignment for high performance display design

  • Lee, Won-Gyu;Choe, Ji-Hyeok;Na, Hyeon-Jae;Im, Ji-Hun;Han, Jeong-Min;Hwang, Jeong-Yeon;Seo, Dae-Sik
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.161-161
    • /
    • 2009
  • Ion bombarded inorganic materials for LC alignment has been researched as it provides controllability in a nonstop process for producing high-resolution displays. Many optically transparent insulators such as $SiOx$ and a-C:H have been investigated as potential candidates for inorganic alignment materials. Even so, LC orientation on a new material with superior capacity is required to produce high-performance displays. Many inorganic materials with high permittivities can reduce the voltage losses due to the LC alignment layer that are a trade-off for its capacitance. The minimum voltage for device operation can be applied to the LC under low external voltage using these materials. This means that low power consumption for LCD applications can be achieved using a high-k alignment structure in which the LC can be driven effectively with a low threshold voltage. Among the many other potential high-k oxides, HfO2 is considered to be one of the most promising due to its remarkable properties of high dielectric constant, relatively low leakage current, large band gap (5.68 eV), and high transparency. Due to these characteristics, HfO2 can be used in LC alignment to increase the capacitance of the inorganic alignment layer for low-voltage driving of LCs.

  • PDF

Flexible Voltage Support Control with Imbalance Mitigation Capability for Inverter-Based Distributed Generation Power Plants under Grid Faults

  • Wang, Yuewu;Yang, Ping;Xu, Zhirong
    • Journal of Power Electronics
    • /
    • v.16 no.4
    • /
    • pp.1551-1564
    • /
    • 2016
  • The high penetration level of inverter-based distributed generation (DG) power plants is challenging the low-voltage ride-through requirements, especially under unbalanced voltage sags. Recently, a flexible injection of both positive- (PS) and negative-sequence (NS) reactive currents has been suggested for the next generation of grid codes. This can enhance the ancillary services for voltage support at the point of common coupling (PCC). In light of this, considering distant grid faults that occur in a mainly inductive grid, this paper proposes a complete voltage support control scheme for the interface inverters of medium or high-rated DG power plants. The first contribution is the development of a reactive current reference generator combining PS and NS, with a feature to increase the PS voltage and simultaneously decrease the NS voltage, to mitigate voltage imbalance. The second contribution is the design of a voltage support control loop with two flexible PCC voltage set points, which can ensure continuous operation within the limits required in grid codes. In addition, a current saturation strategy is also considered for deep voltage sags to avoid overcurrent protection. Finally, simulation and experimental results are presented to validate the effectiveness of the proposed control scheme.