• 제목/요약/키워드: Low mAs

검색결과 10,290건 처리시간 0.043초

0.13μm Cu/Low-k 공정 Setup과 수율 향상에 관한 연구 (A Study on 0.13μm Cu/Low-k Process Setup and Yield Improvement)

  • 이현기;장의구
    • 한국전기전자재료학회논문지
    • /
    • 제20권4호
    • /
    • pp.325-331
    • /
    • 2007
  • In this study, the inter-metal dielectric material of FSG was changed by low-k material in $0.13{\mu}m$ foundry-compatible technology (FCT) device process based on fluorinated silicate glass (FSG). Black diamond (BD) was used as a low-k material with a dielectric constant of 2.95 for optimization and yield-improvement of the low-k based device process. For yield-improvement in low-k based device process, some problems such as photoresist (PR) poisoning, damage of low-k in etch/ash/cleaning process, and chemical mechanical planarization (CMP) delamination must be solved. The PR poisoning was not observed in BD based device. The pressure in CMP process decreased to 2.8 psi to remove the CMP delamination for Cu-CMP and USG-CMP. $H_2O$ ashing process was selected instead of $O_2$ ashing process due to the lowest condition of low-k damage. NE14 cleaning after ashing process lot the removal of organic residues in vias and trenches was employed for wet process instead of dilute HF (DHF) process. The similar-state of SRAM yield was obtained in Cu/low-k process compared with the conventional $0.13{\mu}m$ FCT device by the optimization of these process conditions.

MODELS FOR THE IRAS LOW RESOLUTION SPECTRA OF OH/IR STARS

  • Lee, Sung-Min;Suh, Kyung-Won
    • Journal of Astronomy and Space Sciences
    • /
    • 제15권2호
    • /
    • pp.291-295
    • /
    • 1998
  • We investigate models for the IRAS LRS)Low Resolution Spectra) of OH/IR stars. OH/IR stars often show the silicate features at 9.7 ${mu}m$ and $18{mu}m$ in the spectra obtained by the IRAS LRS as well as remarkably red values in the IRAS photometric colors such as [60]-[25] and [25]-[12]. We compare the radiative transfer model results with observed spectral energy distributions (SEDs) of the stars including IRAS PSC(Point Source Catalog), IRAS LRS and ground based observational data.

  • PDF

海岸 鹽濕地 生態系의 에너지 流轉 (Energy Flow in a Coastal Salt Marsh Ecosystem)

  • Kim, Joon-Ho;Beung Tae Ryu
    • The Korean Journal of Ecology
    • /
    • 제8권3호
    • /
    • pp.153-161
    • /
    • 1985
  • Energy flow through the trophic levels was studied at a salt marsh ecosystem distinguished into low and high marsh. Gross primary productions of Suaedeto-Salicornietum and Artemisieto-Limonietum at low marsh were 8, 299 and 13, 154kca/$m^2$/yr, and those of Calama-grostetum and Sonchuso-Setaetum at high marsh were 17, 899 and 15, 177kca/$m^2$/yr, respectively. Efficiencies of solar energy utilization of plants were 1.7 and 2.6% at the former, and were 3.6 and 3.2% at the latter. Of gross productions, net primary productions were 3, 977 and 5, 280kca/m2/yr at low marsh and were 6, 354 and 5, 329kca/$m^2$/yr at high marsh, and the remainder, 52~67%, was consumed by respiration of plants. A small amount (0.03~0.04%) of the net primary production was flowed through grazing food chain and most amout was transferred into dead parts. Of dead parts, 40% was accuulated as litter and the rest was decomposed into detritus. In the detritus food chain, a little energy was utilized by detritus feeder, and a major by microorganism. The amounts of energy flowed through grazing and detritus feeders at high marsh were much more than those at low marsh, but tertary production as spider was Vice versa.

  • PDF

Chain Transfer to Monomer and Polymer in the Radical Polymerization of Vinyl Neo-decanoate

  • Balic, Robert;Fellows, Christopher M.;Van Herk, Alex M.
    • Macromolecular Research
    • /
    • 제12권4호
    • /
    • pp.325-335
    • /
    • 2004
  • Molecular weight distributions of poly(vinyl neo-decanoate) produced by the bulk polymerization of the monomer to low conversions were investigated to obtain values of the rate constants for the chain transfer to monomer ( $C_{M}$). The value of $C_{M}$ of 7.5($\pm$0.6)${\times}$10$^{-4}$ was obtained from a logarithmic plot of the number distribution at 5,25, and 5$0^{\circ}C$, which suggests that the activation energy for chain transfer is on the order of 20-25 kJ ㏖$^{-1}$ . These plots were linear between the number and weight-average degrees of polymerization, but not over the whole molecular weight range for which a significant signal was observed in the gel permeation chromatography (GPC) trace. Modeling suggests that the deviations observed at high molecular weights can be explained by branching of the chains through chain transfer to the polymer, with a branching density as low as 10$^{-5}$ , without affecting the slope at low values of the number of monomer unit, N. This deviation from the expected distribution of linear chains was used to estimate the branching densities at low conversion.ion.

저상 고상 승강장 겸용 승강문 스텝 성능조건에 관한 연구 (A Study on Performance Requirements of Doorstep Equipments for Both the Low and the High Level Platforms)

  • 김철수;안승호;정광우;김재문;이승일;최덕호;박민흥
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.484-489
    • /
    • 2011
  • Heights of a platform above the rail for the passenger train in the country are classified into two categories such as the low level (500mm; mainline) and the high level (1,135mm; metropolitan subway line) platforms. In order to operate similarly both a mainline railroad and a metropolitan subway line, as the requisite door safety system, it is necessary to develop the doorstep equipment of the rolling stock regardless of both the low and high level platforms. In this study, performance requirements of doorstep equipments used for two types of platforms are examined on the supposition that the train only for the low level platform could stop in the both low and high level platforms.

  • PDF

정보통신기기용 과도전압 차단장치의 개발에 관한 연구 (A Study on the Development of a Transient Voltage Blocking Device for Info-communication Facilities)

  • 한주순
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제23권2호
    • /
    • pp.159-167
    • /
    • 1999
  • This paper presents a new transient voltage blocking device(TOBD)which low power and high frequency bandwidth to protect info-communication facilities from transient voltages. Conventional protection devices have some problems such as low frequency bandwidth low ener-gy capacity and high remnant voltage. in order to improve these limitations a hybrid type TOBD which consists of a gas tube avalanche diodes and junction type field effect transistor (JFETs) is developed. The TOBD differs from the conventional protection devices in configuration and JFETs are used as an active non-linear element and a high speed switching diode with low capacitance limited high current. Therefore the avalanche diode with low energy capacity are protected from the high current and the TOBD has a very small input capacitance. From the performance test using combination surge generator which can produce $1.2/50{\mu}m$ 4.2 kV/max, $8/20{\mu}m$ 2.1 kAmax it is confirmed that the proposed TOBD has an excellent protection per-formance in tight clamping voltage and limiting current characteristics.

  • PDF

둥근 어깨 자세를 가진 자의 등세모근 위 섬유의 압통점에 975-nm GaAlAs 저출력레이저 적용에 대한 즉각적인 효과 (The Immediate Effects of 975-nm GaAlAs Low-level Laser Therapy on Myofacial Triger Point of Upper Trapezius Muscle in Subjects with Rounded Shoulder Posture)

  • 김병조;이정훈
    • 대한물리의학회지
    • /
    • 제9권4호
    • /
    • pp.433-438
    • /
    • 2014
  • PURPOSE: The purpose of our study was to compare a 975-nm, 500-mW GaAlAs low-level laser therapy versus placebo low-level laser therapy with regard to the immediate changes on the myofascial trigger point of the dominant upper trapezius muscle in subjects with rounded shoulder posture. METHODS: Thirty-two male college students with rounded shoulder posture and shoulder pain consented to participate in the experiment. The subjects were randomly assigned to a 2-minute procedure with either an active GaAlAs low-level laser or a placebo GaAlAs low-level laser. The pressure-pain threshold and visual analog scale on tenderness at 3 kg were measured with an algometer before and after the laser treatments. RESULTS: The active GaAlAs low-level laser group showed significant changes in pressure-pain threshold and visual analog scale on tenderness at 3 kg (p<0.05). The placebo GaAlAs low-level laser group showed no significant changes in either pressure-pain threshold or visual analog scale on tenderness at 3 kg (p>0.05). CONCLUSION: An immediate effect was observed in pressure-pain threshold and visual analog scale on tenderness at 3 kg following a 2-minute application ($857.14J/cm^2$) of a 975-nm, 500-mW GaAlAs low-level laser to the myofascial trigger point of the dominant upper trapezius muscle in patients with rounded shoulder posture.

전력케이블용 저밀도폴리에틸렌박막의 전기전도특성 (Electric conduction properties of low density Polyethylene film for Power cable)

  • 황종국;홍능표;이용우;소병문;홍진웅
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1994년도 추계학술대회 논문집
    • /
    • pp.143-146
    • /
    • 1994
  • In older to investigate the properties of electric conduction in low density polyethylene(LDPE) for power cable, the thickness of specimen was the 30, 100($\mu\textrm{m}$) of LDPE. The experimental condition for conductive properties was measured until the breakdown occurs at temperature ranges from 30 to 110[$^{\circ}C$] and in the electric field of 1 to 5 ${\times}$10$^2$[Mv/m]. As for increase of temperature, the current density of LDPE was increased with constant ratio in low field, but changes with exponential function in high field. The tunnel current of pre-breakdown region is shifted toward low field as much as thermal excitation energy.

흉부 Phantom을 이용한 Low Dose CT의 관전압과 ASIR(Adaptive Statistical Iterative Reconstruction)적용에 따른 영상평가 및 피폭선량에 관한 연구 (A study of image evaluation and exposure dose with the application of Tube Voltage and ASIR of Low dose CT Using Chest Phantom)

  • 황혜성;김누리;정윤지;구은회;김기정
    • 대한디지털의료영상학회논문지
    • /
    • 제16권2호
    • /
    • pp.9-14
    • /
    • 2014
  • Purpose: The purpose of this study has attempted to evaluate and compare the image evaluation and exposure dose by respectively applying Filtered Back Projection(FBP), the existing test method, and Adaptive Statistical Iterative Reconstruction(ASIR) with different values of tube voltage during the Low Dose Computed Tomography(LDCT). Materials and Methods: With the image reconstruction method as basis, Chest Phantom was utilized with the FBP and ASIR set at 10%, 20% respectively, and the change of Tube Voltage (100kVp, 120kVp). For image evaluation, Back ground noise, Signal to Noise ratio(SNR) and Contrast to Noise ratio(CNR) were measured, and, for dose evaluation, CTDIvol and DLP were measured respectively. The statistical analysis was tested with SPSS(ver. 22.0), followed by ANOVA Test conducted after normality test and homogeneity test. (p<0.05). Results: In terms of image evaluation, there was no outstanding difference in Ascending Aorta(AA) SNR and Infraspinatus Muscle(IM) SNR with the different values of ASIR application(p<0.05), but a significant difference with the different amount of tube voltage(p>0.05). Also, there wasn't noticeable change in CNR with ASIR and different amount of Tube Voltage (p<0.05). However, in terms of dose evaluation, CTDIvol and DLP showed contrasting results(p<0.05). In terms of CTDIvol, the measured values with the same tube voltage of 120kVp were 2.6mGy with No-ASIR and 2.17mGy with 20%-ASIR respectively, decreased by 0.43mGy, and the values with 100kVp were 1.61mGy with No-ASIR and 1.34mGy with 20%-ASIR, decreased by 0.27mGy. In terms of DLP, the measured values with 120kVp were $103.21mGy{\cdot}cm$ with No-ASIR and $85.94mGy{\cdot}cm$ with 20%-ASIR, decreased by $17.27mGy{\cdot}cm$(about 16.7%), and the values with 100kVp were $63.84mGy{\cdot}cm$ with No-ASIR and $53.25mGy{\cdot}cm$ with 20%-ASIR, a decrease by $10.62mGy{\cdot}cm$(about 16.7%). Conclusion: At lower tube voltage, the rate of dose significantly decreased, but the negative effects on image evaluation was shown due to the increase of noise. For the future, through the result of the experiment, it is considered that the method above would be recommended for follow-up patients or those who get health checkup as long as there is no interference on the process of diagnosis due to the characteristics of Low Dose examination.

  • PDF

정전압 분극곡선법에 의한 아말감의 부식 거동에 관한 연구 (A STUDY ON THE CORROSION BEHAVIOUR OF AMALGAMS BY USING OF POTENTIOSTATIC POLARIZATION METHOD)

  • 신동훈;엄정문
    • Restorative Dentistry and Endodontics
    • /
    • 제12권1호
    • /
    • pp.39-49
    • /
    • 1986
  • The purpose of this study was to observe characteristic properties through the polarization curves and SEM images from 4 different types of amalgam obtained by using the potentiostats (Princeton EG & G) & SEM (Jeol/35), and to investigate the degree of corrosion on the oxidation peak of the each phase of amalgam. After each amalgam alloy and Hg was triturated as the direction of the manufacturer by means of the mechanical amalgamator (Shofu Co.), the triturated mass was inserted into the cylindrical metal mold which was 12mm in diameter and 10.0mm in height and was condensed by using routine manner. The specimen was removed from the mold and stored at room temperature for about 24 hours. The standard surface preparation was routinely carried out. Anodic polarization measurement was employed to confirm the corrosion behaviour of the amalgams in a 0.9% saline solution (P.H: 6.8-7.0) at $37^{\circ}C$. The initial rest potential (corrosion potential) was determined after 30 minutes of immersion of specimen in electrolyte, and the potential scan was begun at the point of 100mV cathodic from the corrosion potential. The scan rate was 0.17mV/sec. in the study to observe the degree of corrosion of each phase. SEI and EPMA images on the determined oxidation peaks of each amalgam were observed. The results were as follows: 1. In the four anodic polarization curves, low copper amalgams have three oxidation peaks and high copper amalgams have two oxidation peaks, -270mV, +26mV and +179mV(SEC) in the low copper lathe cut, and -300mV, +39mV and +163mV(SEC) in the low copper spherical. -4mV and +154mV(SEC) in the Dispersalloy, and +17mV and +180mV(SEC) in the Tytin as high copper amalgams. 2. ${\gamma}_2$ phase in the low copper amalgam and ${\eta}$ phase in the high copper amalgam were the most corrodible phases and Ag-Cu eutectic in high copper amalgam was the most slowly corroded phase. 3. Low copper amalgam was more susceptible in corrosion than high copper amalgam.

  • PDF