• 제목/요약/키워드: Low level radiation

검색결과 432건 처리시간 0.027초

Study of Naturally Occurring Radioactive Material Present in Deep Soil of the Malwa Region of Punjab State of India Using Low Level Background Gamma-Ray Spectrometry

  • Srivastava, Alok;Chahar, Vikash;Chauhan, Neeraj;Krupp, Dominik;Scherer, Ulrich W.
    • Journal of Radiation Protection and Research
    • /
    • 제47권1호
    • /
    • pp.16-21
    • /
    • 2022
  • Background: Epidemiological observations such as mental retardation, physical deformities, etc., in children besides different types of cancer in the adult population of the Malwa region have been reported. The present study is designed to get insight into the role of naturally occurring radioactive material (NORM) in causing detrimental health effects observed in the general population of this region. Materials and Methods: Deep soil samples were collected from different locations in the Malwa region. Their activity concentrations were determined using low-level background gammaray spectrometry. High efficiency and high purity germanium detector capped in a lead-shielded chamber having a resolution of 1.8 keV at 1,173 keV and 2.0 keV at the 1,332 keV line of 60Co was used in the present work. Data were evaluated with Genie-2000 software. Results and Discussion: Mean activity concentrations of 238U, 232Th, and 40K in deep soil were found to be 101.3 Bq/kg, 65.8 Bq/kg, and 688.6 Bq/kg, respectively. The mean activity concentration of 238U was found to be three and half times higher than the global average prescribed by the United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR). It was further observed that the activity concentration of 232Th and 40K has a magnitude that is nearly one and half times higher than the global average prescribed by UNSCEAR. In addition, the radioisotope 137Cs which is likely to have its origin in radiation fallout was also observed. It is postulated that the NORM present in high quantity in deep soil somehow get mobilized into the water aquifers used by the general population and thereby causing harmful health problems. Conclusion: It can be stated that the present work has been able to demonstrate the use of low background gamma-ray spectrometry to understand the role of NORM in causing health-related effects in a general population of the Malwa region of Punjab, India.

Effect of Extremely Low Frequency Magnetic Fields on Gene Expression in Human Mammary Epithelial MCF10A Cells

  • Hong, Mi-Na;Lee, Hyung-Chul;Kim, Bong Cho;Lee, Yun-Sil;Gimm, Yoon-Myung;Myung, Sung-Ho;Lee, Jae-Seon
    • Journal of electromagnetic engineering and science
    • /
    • 제12권4호
    • /
    • pp.271-279
    • /
    • 2012
  • The effects of extremely low frequency magnetic fields (ELF-MFs) on physiological processes at the cellular level remain unclear despite a number of studies. To investigate the effects of ELF-MFs on gene expression, we exposed human mammary epithelial MCF10A cells to fields of 1 mT magnetic flux density at 60 Hz for 4 and 16 h and measured the transcriptional responses of 24,000 genes using Illumina microarrays. In three independent experiments, we found no statistically significant alteration of expression levels for any of the genes assayed using a cutoff value of 1.2-fold. To confirm this result, we selected six genes with trends suggesting possible expression level changes, although these trends were not statistically significant, and investigated their expression levels further using a semiquantitative reverse-transcription polymerase chain reaction. In three independent experiments, we did not find any alterations in the expression levels of these genes. From these results, we conclude that ELF-MFs do not affect gene expression profiles under our exposure conditions.

중성자, 감마선, 엑스선 방사선 측정 및 통합 제어 시스템 개발 (Development of Neutron, Gamma ray, X-ray Radiation Measurement and Integrated Control System)

  • 고태영;이주현;이승호
    • 전기전자학회논문지
    • /
    • 제21권4호
    • /
    • pp.408-411
    • /
    • 2017
  • 본 논문에서는 중성자, 감마선, 엑스선 등의 방사선을 측정하는 통합 제어 시스템을 제안한다. 제안하는 시스템은 원격 또는 네트워크상으로 측정 및 분석한 데이터를 디스플레이를 통해 모니터링 및 제어할 수 있는 장비로서, 현장에 가지 않고도 시스템 각 구성 부분의 상태를 보고 변경하여 원격으로 감시 및 관리할 수 있다. 제안하는 시스템은 감마선/엑스선 센서부, 중성자 센서부, 주제어 임베디드 시스템부, 전용 디스플레이 장치 및 GUI부, 원격 UI부 등으로 구성된다. 감마선/엑스선 센서부는 NaI(Tl) Scintillation Detector를 사용하여 저준위의 감마선 및 엑스선을 측정한다. 중성자 센서부는 Proportional Counter Detector(저준위 중성자)와 Ion Chamber Type Detector(고준위 중성자)를 사용하여 중성자를 측정한다. 주제어 임베디드 시스템부는 방사선을 검출하여 초단위로 샘플링하고 누적된 펄스 및 전류값에 대한 방사선량으로 변환한다. 전용 디스플레이 장치 및 GUI부는 방사선 측정 결과와 변환된 방사선량 및 방사능량 측정 수치를 출력하고, 사용자에게 제어 조건 설정 및 검출부에 대한 캘리브레이션 기능을 제공한다. 원격 UI부는 측정된 값들을 취합, 저장하여 원격 감시 시스템에 전달한다. 제안된 시스템의 성능을 평가하기 위하여 공인시험기관에서 실험한 결과는 중성자 검출부는 ${\pm}8.2%$ 이하의 측정 불확도가 측정되었고, 감마선, 엑스선 검출부는 7.5%이하의 불확도가 측정되어 국제 표준인 ${\pm}15%$ 이하에서 정상동작 됨이 확인되었다.

Anti Inflammatory Effect of Low Level Laser Irradiation on the LPS-stimulated Murine Immunocytes

  • Jin, Dan;Lee, Jong-Young;Cho, Hyun-Chul;Kim, Soo-Ki
    • Molecular & Cellular Toxicology
    • /
    • 제1권2호
    • /
    • pp.124-129
    • /
    • 2005
  • Pro-inflammatory cytokines, such as tumor necrosis factor $(TNF)-{\alpha}$, interleukin-12 (IL-12) and interleukin $(IL-1)-{\beta}$, play a key role in causing inflammatory diseases, which are rheumatoid arthritis, Crohn's disease and sepsis. Accumulating evidences suggest that low level laser irradiation (LLLI) may have an anti-inflammatory action. However, there are few data regarding down regulation of Th1 immune response by using the diod typed laser emitting device for human patients. As a fundamental step in order to address this issue, we investigated immunological impact of the low level laser irradiation (10 mw laser diode with a wavelength of 630 nm) on expression of pro-inflammatory cytokines in murine immunocytes (splenocytes and peritoneal macrophages) in vitro. The LLLI on lipopolysaccharide (LPS 100 ng/ml)-stimulated murine splenocytes and macrophages, clearly down regulated mRNA expression of $TNF-{\alpha}$ and IL-12 in dose-dependent manner. In addition, LLLI significantly inhibits the NO production in the LPS-stimulated murine macrophages. This data suggests that LLLI (wavelength of 630 nm) may exert an anti-inflammatory action via modulation of pro-inflammatory cytokine and NO production pathway.

듀얼 FDG 자동합성장치 개발 (Development of Dual FDG Auto Synthesis Module)

  • 정철기;이경진;허민구;장홍석;민영돈
    • 방사선산업학회지
    • /
    • 제5권4호
    • /
    • pp.313-316
    • /
    • 2011
  • [$^{18}F$]FDG (2-[$^{18}F$] Fluoro-2-deoxy-D-Glucose), which is required Automated Synthetic Module for production, is most often used Radiopharmaceuticals in nuclear medicine. In this study, an Automated Synthesis Module was developed to produce FDG in two consecutive time when F-18 feds continuously by modifying a domestic FDG Automated Synthetic Module on structural geometry and control system. The results were showed that the Average Synthesis Yields on the developed Automated Synthetic Module were $45{\pm}3%$ (n=20), $50{\pm}3%$ (n=20) respectively. The Quality Control results, such as Radio TLC, Radiochemical purity, Gamma-counter, pH, LAL Test, Micro bacteria test, showed in same level with domestic [$^{18}F$]FDG Auto-Synthetic modules. Therefore, if some features were improved by considering the components life time and appearance, commercial sales can be expected because of low price and easy maintenance compared with foreign products.

Feasibility study of spent fuel internal tomography (SFIT) for partial defect detection within PWR spent nuclear fuel

  • Hyung-Joo Choi;Hyojun Park;Bo-Wi Cheon;Hyun Joon Choi;Hakjae Lee;Yong Hyun Chung;Chul Hee Min
    • Nuclear Engineering and Technology
    • /
    • 제56권6호
    • /
    • pp.2412-2420
    • /
    • 2024
  • The International Atomic Energy Agency (IAEA) mandates safeguards to ensure non-proliferation of nuclear materials. Among inspection techniques used to detect partial defects within spent nuclear fuel (SNF), gamma emission tomography (GET) has been reported to be reliable for detection of partial defects on a pin-by-pin level. Conventional GET, however, is limited by low detection efficiency due to the high density of nuclear fuel rods and self-absorption. This paper proposes a new type of GET named Spent Fuel Internal Tomography (SFIT), which can acquire sinograms at the guide tube. The proposed device consists of the housing, shielding, C-shaped collimator, reflector, and gadolinium aluminum gallium garnet (GAGG) scintillator. For accurate attenuation correction, the source-distinguishable range of the SFIT device was determined using MC simulation to the region away from the proposed device to the second layer. For enhanced inspection accuracy, a proposed specific source-discrimination algorithm was applied. With this, the SFIT device successfully distinguished all source locations. The comparison of images of the existing and proposed inspection methods showed that the proposed method, having successfully distinguished all sources, afforded a 150 % inspection accuracy improvement.

방사능(선)에 관한 차세대 인식도 및 교육방향에 대한 고찰 (And recognition of the next generation about the radioactivity A Study on the direction of education)

  • 서동우;김경연;김종은;배현학;손재호;전민규;정재은
    • 대한디지털의료영상학회논문지
    • /
    • 제16권1호
    • /
    • pp.43-47
    • /
    • 2014
  • Sens of insecutity of the public and professionals about harmful effects of radiation is increasing in an accident at the Chernobyl and Fkushima nuclear power plant.Anxiety was amplified to lack of information about radiation majority of people. To target the middle and high school in the region of Daegu and Gyeongsangbuk-do, to investigate the radiation recognition of the next generation, it is intended to present a model of education for the safe use of radiation. The High School of the six metropolitan cities, city, town through the questionnaire and needs to be educational experience of radiation and use knowledge level of radiation, experience in daily life, understanding of man-made radiation and natural radiation, information channel on radiation, the radiation Distribute the total 800 parts of, to recover the 629 unit, was analyzed for 155 females 474 males. Many people 75.36% of the people, to 24.64% female subjects of this investigation, was constant, respectively from 13 to 18 years age. It is a large number and 30.37% of the respondents as "normal" level of knowledge of radiation, for the type of radiation, most knew. You have answer for risk experience of the medical radiation was higher, touching a lot of information via the broadcast medium in general, and the accuracy is low. I thought we wanted to be educated three or more twice a year, as an educator,about 71.37% and radiation-related understanding of knowledge and background in accordance with the diversification of information channels, the regional differences between urban and rural areas. But I considered the difference age (grade) for each is displayed, intended for junior high school students, the target surface and use the occurrence of radiation, high school students, the need for education about risk and application of radiation through this study.

  • PDF

치과종사자들의 방사선 안전관리에 대한 지식 및 행태 (The Knowledge, Attentions and Behaviors of Radiation Safety Managment by Dental Health care Workers)

  • 이선미;김민지
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제42권6호
    • /
    • pp.469-476
    • /
    • 2019
  • The purpose of this study examines the education, knowledge and behavior of radiation safety management among dental workers and compares the education, knowledge and behavior between dental hygienist group and other occupational groups. This study was conducted from November 2nd to November14th, 2019. The survey was conducted on dental workers(dental hygienists, nursing, assistants, coordinators, etc.) who worked in dental hospitals and clinics in Busan area. The tool of this study was modified and adapted to the clinical setting based on the questionnaire. Radiation safety education has 39 dental hygienists who had more education than non-dental hygienists (p=0.286). The most common types of radiation safety education were self-education which usually performed by dentistry, followed by conservative education and others. The average of radiation attitudes, knowledge and behaviors was higher in the dental hygienist group then in the non-dental hygienist group. On the item-specific behavior among employees, the question of 'the radiation should be shielded according to the menstrual cycle or pregnancy of the woman of childbearing' was significant (p<0.05). On the item-specific knowledge between occupations, the question of 'the intensity of X-rays decreases over distance' and 'the individual exposure can be measured by TLD badge or film badge' was significant (p<0.05). Taken together, these results indicate that the dental hygienist group is more concerned about radiation safety and that the dental hygienist group is receiving more radiation safety management training. However, if there is a low level of 'has experienced' in the presence or absence of safety management education, it is difficult to train radiation safety management in dentistry. Therefore, it is considered that dentists should be trained in radiation safety management periodically to pay attention to radiation safety accidents.

환경중 방사성 스트론튬 분석 방법 연구 (A Study on the Environmental Radioactive Strontium Analysis)

  • 이경진;황정래;정운관
    • Journal of Radiation Protection and Research
    • /
    • 제24권3호
    • /
    • pp.155-160
    • /
    • 1999
  • 환경 중에는 핵실험 및 원자력 발전소에서 방출되는 여러 가지 방사성 핵종들과 천연방사성 핵종들이 존재한다. 이 중에서 원자력발전소 운영과 관련하여, 환경 중의 인공방사성 핵종에 대한 관심이 높아지고 있다. 핵실험이나 원자력발전소와 관련된 인공방사선 핵종들은 주로 핵분열 생성물들로서, 그 수가 200여종에 이른다. 이 중에서도 $^{90}Sr$$^{137}Cs$은 선량특성상 특히 주목되어 왔다. 본 논문에서는 환경준위의 $^{90}Sr$ 정량 분석 방법에 대한 연구를 수행하였다. 환경 중의 $^{90}Sr$은 저준위이며, 특성 감마선과는 달리 연속 스팩트럼의 베타선원으로, $^{89}Sr$, $^{90}Y$ 및 다른 방사성 핵종들과 혼합되어 있기 때문에 정량적인 분석이 매우 어렵다. 저준위 방사성 스트론튬 분석을 위해서는 농축 과정 및 분석에 영향을 주는 타 방사성 핵종과의 화학적 분리과정이 필요하다. 그 동안 국내 여러 기관에서 공통적으로 스트론튬 회수율 산정을 위해 중량법을 사용하였고, 화학분리절차도 중량법을 사용하기에 적합하도록 개발하여 사용하였다. 최근 분석기기의 발달로 인해서, ppm 이나 ppb 단위의 안정원소 분석을 쉽게 할 수 있다는 점에 근거하여, 원자분광분석기기(ICP : Inductively Coupled atomic Plasma emission spectrophotometer)를 사용한 회수율 산정 및 그에 적합한 절차를 개발하였다. 개발된 절차는 기존의 중량법에 비해서 화학적 처리절차가 훨씬 간편하면서도 정확도가 높아서, 환경방사성 스트론튬의 정량분석에 적절히 사용될 수 있다.

  • PDF