• Title/Summary/Keyword: Low level radiation

Search Result 435, Processing Time 0.079 seconds

A Study on the Patient Exposure Doses from the Panoramic Radiography using Dentistry (치과 파노라마 촬영에서 환자의 피폭선량에 관한 연구)

  • Park, Ilwoo;Jeung, Wonkyo;Hwang, Hyungsuk;Lim, Sunghwan;Lee, Daenam;Im, Inchul;Lee, Jaeseung;Park, Hyonghu;Kwak, Byungjoon;Yu, Yunsik
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.1
    • /
    • pp.17-24
    • /
    • 2013
  • This study estimate radiation biological danger factor by measuring patient's exposed dose and propose the low way of patient's exposed dose in panoramic radiography. We seek correcting constant of OSL dosimeter for minimize the error of exposed dose's measurement and measure the Left, Right crystalline lens, thyroid, directly included upper, lower lips, the maxillary bone and the center of photographing that indirect included in panoramic radiography by using the human body model standard phantom advised in ICRP. In result, the center of photographing's level of radiation maximum value is $413.67{\pm}6.53{\mu}Gy$ and each upper, lower lips is $217.80{\pm}2.98{\mu}Gy$, $215.33{\pm}2.61{\mu}Gy$. Also in panoramic radiography, indirect included Left, Right crystalline lens's level of radiation are $30.73{\pm}2.34{\mu}Gy$, $31.87{\pm}2.50{\mu}Gy$, and thyroid's level of measured exposed dose can cause effect of radiation biological and we need justifiable analysis about radiation defense rule and substantiation advised international organization for the low way of patient's exposed dose in panoramic radiography of dental clinic and we judge need the additional study about radiation defense organization for protect the systematize protocol's finance and around internal organs for minimize until accepted by many people that is technological, economical and social fact by using panoramic measurement.

Determination of optimum gamma ray range for radiation mutagenesis and hormesis in quinoa (Chenopodium quinoa Willd.)

  • Park, Chan Young;Song, Seon Hwa;Sin, Jong Mu;Lee, Hyeon Young;Kim, Jin Baek;Shim, Sang In
    • Proceedings of the Korean Society of Crop Science Conference
    • /
    • 2017.06a
    • /
    • pp.240-240
    • /
    • 2017
  • Quinoa (Chenopodium quinoa Willd.) is one of the ancient crops cultivated in the Andes region at an altitude of 3,500-4000m in Chile and Bolivia from 5000 BC. It contains a large amount of protein, minerals and vitamins in comparison with other crops. The cultivation area has been increasing worldwide because of its excellent resistance to various abiotic stress such as salinity, drought and low temperature. ${\gamma}$-Ray radiation of high dose is often used as a tool to induce mutations in plant breeding, but it has a deleterious effect on organisms. However, the radiation may have a positive stimulatory effect of 'hormesis' in the low dose range. This experiment was carried out to investigate the optimum dose range for creating the quinoa genetic resources and to investigate the hormesis effect at low dose on the quinoa. This experiment was performed for 120 days from November, 2016 to February, 2017 in the greenhouse of Gyeongsang National University. ${\gamma}$-Ray radiation was irradiated to seeds at 0 Gy, 50 Gy, 100 Gy, 200 Gy, 300 Gy, 400 Gy, 600 Gy, 800 Gy and 1000 Gy for 8 hours. (50 Gy) using the low level radiation facility ($Co^{60}$) of Cooperative Research Institute of Radiation Research Institute, KAERI. Fifty seeds were placed on each petri dish lined with wet filter paper and germination rate was measured at a time interval of 2 hours for 40 hrs. The length of the root length was measured one week after germination. Each treatment was carried out in 3 replicates. The growth of seedlings were investigated for 10 days after transplanting of 30 day-old seedlings. The plant height, NDVI, SPAD, Fv/Fm, and panicle weight were measured. The germination rate was highest at 50Gy and 0Gy and the rate of seeds treated with 400Gy or higher rate decreased to 25% of the seeds treated with 50Gy. The emergence rate of seedling in pot experiment was higher at the dose of 200 Gy, 300 Gy and 400 Gy than at 0 and 50Gy. However, the rate was lower at strong radiation higher than 600Gy at which $1^{st}$ leaf was not expanded fully and dead due to extreme overgrowth at 44 days after treatment (DAT). The highest value of panicle weight was observed at 50Gy (6.15g) and 100Gy (5.57g). On the other hand, the weight at high irradiated dose of 300Gy and 400Gy was decreased by about 55% compared to low dose (50 Gy). NDVI measurement also showed the highest value at 50 Gy as the growth progressed. SPAD was the highest at 400 Gy and showed positive correlation with irradiation dose except 0 Gy. Fv/Fm was high at 50 Gy up to 30 DAT and no difference between treatments was observed except for 400 Gy from 44 DAT. The plant height was the highest in 50Gy during the growing period and was higher in the order of 50Dy, 100Gy, 0Gy, 200Gy, 300Gy and 400Gy in 88 DAT. In this experiment, the optimal radiation dose for hormesis was 50Gy and 100Gy, and the optimal radiation dose for mutagenesis seems to be 400 Gy.

  • PDF

Evaluation of the Space Scattered Dose According to the Position of the Radiation Workers in Mammography Room (유방촬영 시 방사선관계종사자의 위치에 따른 공간선량평가)

  • Lee, Dong-Yeon;Lee, Jin-Soo
    • Journal of radiological science and technology
    • /
    • v.39 no.3
    • /
    • pp.297-303
    • /
    • 2016
  • This study was conducted to evaluate the dose of the space to the controller located within the mammography room conducted a research on ways to the reduction exposure to the radiation workers. Results, the dose of 6.18 mGy/year was measured when there is no difference in the hilar area of the controller position, the dose of 2.35E-11 mGy/year was measured when installing the Shielding door. In addition, when the direction of the X-ray tube anode be heading this direction controller, low average level measured was 0.30 mGy/year. Based on this study, the mammography should be considered when installing the anode and cathod directions. And, by installing the shielding door, it must be able to completely separate shooting space and control room. This is the best way radiation protection method in radiation workers.

Tube Voltage, DNA Double-Strand Breaks, and Image Quality in Coronary CT Angiography

  • Zhu Xiao Lin;Fan Zhou;U. Joseph Schoepf;Balakrishnan Pillai;Chang Sheng Zhou;Wei Quan;Xue Qin Bao;Guang Ming Lu;Long Jiang Zhang
    • Korean Journal of Radiology
    • /
    • v.21 no.8
    • /
    • pp.967-977
    • /
    • 2020
  • Objective: To evaluate the effects of tube voltage on image quality in coronary CT angiography (CCTA), the estimated radiation dose, and DNA double-strand breaks (DSBs) in peripheral blood lymphocytes to optimize the use of CCTA in the era of low radiation doses. Materials and Methods: This study included 240 patients who were divided into 2 groups according to the DNA DSB analysis methods, i.e., immunofluorescence microscopy and flow cytometry. Each group was subdivided into 4 subgroups: those receiving CCTA only with different tube voltages of 120, 100, 80, or 70 kVp. Objective and subjective image quality was evaluated by analysis of variance. Radiation dosages were also recorded and compared. Results: There was no significant difference in demographic characteristics between the 2 groups and 4 subgroups in each group (all p > 0.05). As tube voltage decreased, both image quality and radiation dose decreased gradually and significantly. After CCTA, γ-H2AX foci and mean fluorescence intensity in the 120-, 100-, 80-, and 70-kVp groups increased by 0.14, 0.09, 0.07, and 0.06 foci per cell and 21.26, 9.13, 8.10, and 7.13 (all p < 0.05), respectively. The increase in the DNA DSB level in the 120-kVp group was higher than those in the other 3 groups (all p < 0.05), while there was no significant difference in the DSBs levels among these latter groups (all p > 0.05). Conclusion: The 100-kVp tube voltage may be optimal for CCTA when weighing DNA DSBs against the estimated radiation dose and image quality, with further reductions in tube voltage being unnecessary for CCTA.

A Study on Factor Related to Fatigue in Cancer Patients Receiving Radiotherapy (방사선 치료를 받는 암환자의 피로 관련 요인간의 상관관계 연구)

  • Ko, Eun;So, Hyang-Sook
    • Korean Journal of Adult Nursing
    • /
    • v.15 no.4
    • /
    • pp.617-627
    • /
    • 2003
  • Purpose: The purpose of this study is to investigate fatigue and its related factors in cancer patients receiving radiotherapy. Method: The subjects of this study consisted of 98 patients receiving radiotherapy. Subjects were recruited from C University Hospital radiation oncology unit located in Gwangju from March to May, 2001. Questionnaire and medical records were used for data collection. The obtained data was analyzed using SAS program that included descriptive statistics, t-test, ANOVA, Post-hoc test(Fisher's LSD) and Pearson's correlation coefficients. Result: The fatigue perceived by the subjects was middle level ($5.59{\pm}1.59$) and 72.4% of them reported greater than 5 points. The subjects in no religion, low income, and spouse caregiver groups experienced the higher fatigue than another groups, respectively. The subjects in nasopharyngeal cancer, head & neck radiation site, and analgesics medication groups did, experience fatigue as well. The fatigue not only positively correlated with symptom distress, disruption of usual activity, sleep dissatisfaction, and mood state, but also negatively with less family support. Conclusion: Cancer patients receiving radiotherapy experience the middle level of fatigue and it correlates with the multi-dimensional factors. However, further research is needed to identify the changes in fatigue over the radiotherapy period through longitudinal design and to develop nursing intervention for fatigue decrease.

  • PDF

The Design of Elliptical Dual Offset Gregorian Antenna for Satellite Communication on Ka-band (Ka대역 위성통신용 타원형 이중옵셋 그레고리안 안테나 설계)

  • Kim, Chun-Won;Cheong, Chi-Hyun;Kim, Kun-Woo;Lee, Seong-Jae
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.16 no.6
    • /
    • pp.811-818
    • /
    • 2013
  • In this paper, we have designed the elliptical dual offset gregorian antenna which can use Ka band earth station antennas in the fixed-satellite service. The structure of antenna is increasing the antenna gain by decreasing blockage areas and decreasing wind effects by shortening height of the antenna. The corrugate horn antenna for this antenna has symmetric radiation patterns and low side lobe levels that can meet ITU-R envelope. The distribution of electric field on a aperture of main reflector is calculated by an ray-tracing method that use the radiation pattern of the feed horn. The final geometric of antena is decided by choosing the distribution that comply with antenna requirement. The FEKO analysed electrical performance of this antenna. The fabricated antenna has 45.0dBi(@30.0GHz)/41.7dBi(@20.2GHz), high efficiency and low side lobe level that meet ITU-R S. 580-6 envelope.

Ultraviolet Radiation-Induced Apoptosis is Inversely Correlated with the Expression Level of Poly(ADP-ribose) Polymerase

  • Oh, Kyu Seon;Lee, Dong Wook;Chang, Jeong Hyun;Moon, Yong Suk;Um, Kyung ll
    • Animal cells and systems
    • /
    • v.5 no.1
    • /
    • pp.77-83
    • /
    • 2001
  • The present study was conducted to elucidate whether the expression level of poly(ADP-ribose) polymerase (PARP) is related to the ultraviolet radiation (UV)-induced apoptosis. After treatment of the mammalian cell lines HeLa S3 and Chinese hamster ovary (CHO) with 50 J/m2 UV, induction of apoptosis was determined by several means during 24 h post-incubation. Incidence of apoptosis was much lower in CHO than HeLa S3 cells based on the percentage of apoptotic cells in terms of morphological changes in nucleus or direct counting of viable cells and qualitative or quantitative DNA fragmentation. Interestingly, when the expression level of PARP was measured by western blotting, the amounts of PARP that was retained at each time point inversely correlated with the incidences of apoptosis in these cells. Concomitant with generation of the 85 kDa fragment, 116 kDa PARP disappeared in HeLa S3 within 6 h after UV treatment, whereas a fair amounts of 116 kDa band was still retained in CHO cells at 36 h post-incubation. This inverse relationship was also observed in the adaptive response system, in which cells weve treated with a high dose of UV after pretreatment with a low dose. As expected, typical adaptive responses appeared in CHO cells but not in HeLa cells, showing greater cell viability and lesser DNA fragmentation. During the adaptive response in CHO cells, PARP was expressed at much higher level compared to the single, high dose-treated cells. Interestingly, even though PARP was induced at 6 h post-incubation In both cell types, its expression was more prominent in CHO cells. Thus, our data indicate that the retained level of intact PARP against UV damage inversely correlates with incidence of apoptosis in mammalian cells, and also suggest that a machinery to protect the PARP degradation against UV damage exists in CHO but not in HeLa S3 cells.

  • PDF

CT Examinations for COVID-19: A Systematic Review of Protocols, Radiation Dose, and Numbers Needed to Diagnose and Predict (COVID-19 진단을 위한 CT 검사: 프로토콜, 방사선량에 대한 체계적 문헌고찰 및 진단을 위한 CT 검사량)

  • Jong Hyuk Lee;Hyunsook Hong;Hyungjin Kim;Chang Hyun Lee;Jin Mo Goo;Soon Ho Yoon
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.6
    • /
    • pp.1505-1523
    • /
    • 2021
  • Purpose Although chest CT has been discussed as a first-line test for coronavirus disease 2019 (COVID-19), little research has explored the implications of CT exposure in the population. To review chest CT protocols and radiation doses in COVID-19 publications and explore the number needed to diagnose (NND) and the number needed to predict (NNP) if CT is used as a first-line test. Materials and Methods We searched nine highly cited radiology journals to identify studies discussing the CT-based diagnosis of COVID-19 pneumonia. Study-level information on the CT protocol and radiation dose was collected, and the doses were compared with each national diagnostic reference level (DRL). The NND and NNP, which depends on the test positive rate (TPR), were calculated, given a CT sensitivity of 94% (95% confidence interval [CI]: 91%-96%) and specificity of 37% (95% CI: 26%-50%), and applied to the early outbreak in Wuhan, New York, and Italy. Results From 86 studies, the CT protocol and radiation dose were reported in 81 (94.2%) and 17 studies (19.8%), respectively. Low-dose chest CT was used more than twice as often as standard-dose chest CT (39.5% vs.18.6%), while the remaining studies (44.2%) did not provide relevant information. The radiation doses were lower than the national DRLs in 15 of the 17 studies (88.2%) that reported doses. The NND was 3.2 scans (95% CI: 2.2-6.0). The NNPs at TPRs of 50%, 25%, 10%, and 5% were 2.2, 3.6, 8.0, 15.5 scans, respectively. In Wuhan, 35418 (TPR, 58%; 95% CI: 27710-56755) to 44840 (TPR, 38%; 95% CI: 35161-68164) individuals were estimated to have undergone CT examinations to diagnose 17365 patients. During the early surge in New York and Italy, daily NNDs changed up to 5.4 and 10.9 times, respectively, within 10 weeks. Conclusion Low-dose CT protocols were described in less than half of COVID-19 publications, and radiation doses were frequently lacking. The number of populations involved in a first-line diagnostic CT test could vary dynamically according to daily TPR; therefore, caution is required in future planning.

Analysis of time-varying low-frequency electric magnetic field emitted from electric rolling stocks fed by VVVF inverter (VVVF 인버터로 구동되는 전기철도차량에서 방출되는 시변 저주파 전자계 분석)

  • Jang, Dong-Uk;Kim, Joo-Rak;Kim, Heol-Cheol
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.507-513
    • /
    • 2010
  • This paper is described the analysis of time-varying low-frequency electric magnetic field emitted from electric rolling stocks fed by VVVF inverter, in reference to allowable magnitude for exposures to time-varying electromagnetic field issued by International Commission on Non-Ionizing Radiation Protection(ICNIRP). The level of the magnetic field strength was measured, in reference to the standard for occupational environments, which takes into account the public person's protection against the excessive emission of the low-frequency magnetic field, 5 Hz ~ 2 kHz.

  • PDF

Design and performance prediction of large-area hybrid gamma imaging system (LAHGIS) for localization of low-level radioactive material

  • Lee, Hyun Su;Kim, Jae Hyeon;Lee, Junyoung;Kim, Chan Hyeong
    • Nuclear Engineering and Technology
    • /
    • v.53 no.4
    • /
    • pp.1259-1265
    • /
    • 2021
  • In the present study, a large-area hybrid gamma imaging system was designed by adopting coded aperture imaging on the basis of a large-area Compton camera to achieve high imaging performance throughout a broad energy range (100-2000 keV). The system consisting of a tungsten coded aperture mask and monolithic NaI(Tl) scintillation detectors was designed through a series of Geant4 Monte Carlo radiation transport simulations, in consideration of both imaging sensitivity and imaging resolution. Then, the performance of the system was predicted by Geant4 Monte Carlo simulations for point sources under various conditions. Our simulation results show that the system provides very high imaging sensitivity (i.e., low values for minimum detectable activity, MDA), thus allowing for imaging of low-activity sources at distances impossible with coded aperture imaging or Compton imaging alone. In addition, the imaging resolution of the system was found to be high (i.e., around 6°) over the broad energy range of 59.5-1330 keV.