• 제목/요약/키워드: Low frequency tester

검색결과 22건 처리시간 0.027초

유압 피팅 충격압시험기 개발 (Hydraulic fitting impulse tester development)

  • 김형의;이용범
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1991년도 한국자동제어학술회의논문집(국내학술편); KOEX, Seoul; 22-24 Oct. 1991
    • /
    • pp.917-921
    • /
    • 1991
  • Hydraulic fitting impulse tester is equipment which produce impulse pressure waveform that specified foreign standard of SAE, JIS etc. Test conditions of SAE J1453 about waveform standard indicates frequency of 35-70 cycle/min, pressure of 560 bar, oil temperature of 93 .+-.3.deg. C etc. and required cycle is a million over. In additions, Test condition operated continuously equipment. This development item adopted new pattern method such as intensifier and rotary distributor is different from already established fitting impulse tester applied servo valve and high pressure direct directional control valve. Therefore, this development item which compares already established item is good reliability, low cost of manufacture and save of electric energy. especially, Domestic small and medium enterprise uses this tester because of economical cause. We develope appropriateness tester which conforms to demand of user.

  • PDF

CF/Epoxy 복합적층판의 저속충격 특성평가에 관한 연구 (A Study on Characteristics Analysis of Low Velocity Impact Response of CF/Epoxy Composite Plates)

  • 임광희;박노식;김영남;김정호;김선규;심재기;양인영
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2002년도 춘계학술발표대회 논문집
    • /
    • pp.85-88
    • /
    • 2002
  • We have implemented a system of falling weight impact tester. Absorbed energy of orthotropic composites with using T300 fiber, which are composed of the same fiber and stacking number is higher than that of quasi-isotropic specimen over impact energy 7J, but in case of using T700 fiber, much difference does not show. Also, absorbed energy of orthotropic composites with using T300 fiber, which are composed of stacking number and orientation became more than that of T700 fiber specimen; however great change doesn't show in case of quasi-isotropic specimens. Delamination area of impacted specimens was measured with ultrasonic C-scanner to find correlation between impact energy and delamination area. Delamination area and frequency responses was evaluated between impacted and unimpacted specimens. There is a strong correlation between frequency responses and impact-induced delamination. The presence and scale of damages have been investigated based on the variations of frequency responses.

  • PDF

무향팬테스터를 이용한 냉장고용 팬 성능/소음 측정 (Measuring performance and SPL of refrigerator fan using anechoic fan tester)

  • 정정교;이준화;주재만;강정훈
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.253-256
    • /
    • 2004
  • Acoustical noise at low frequency range (below 500Hz) of refrigerator result from fans which are inside of the refrigerator. In generally to evaluate and apply to refrigerator it is recommended that acoustical noise and fluidic performance of the fan were measured simultaneously. To do that twin-room type anechoic wind tunnel was needed. But constructing twin room type anechoic wind tunnel was very expensive and estimation of small refrigerator fan performance was not easy. So in this paper we composed anechoic fan tester. A successful noise and performance measurement was performed using the anechoic fan tester. Existing 22 kinds of refrigerator fan were investigated and mapped into one database. Refrigerator duct pressure resistance were measured and reflected into the fan database to find out appropriate fan. Through the application of fan database, the refrigerator became less noise compared to current one and these data shows what is the best way to reduce fan noise.

  • PDF

디지털 제어형 고주파 전력발생장치 개발에 관한 연구 (A Study on the Development of the High-frequency Power Generating System by Digital Control)

  • 김동희;김금수;문종현
    • 전기학회논문지
    • /
    • 제61권3호
    • /
    • pp.401-406
    • /
    • 2012
  • The aim of this research is to develop more actual high-frequency power generators that includes various noise, to make flexible control systems for test or performance analysis of electric and electronic machines. It proposed power generating circuits using basic amplifier, B-level Push-Pull type, and FPGA for the easier control to get data and transmit. And it also testify to realize the proposed systems to report output data by input waveform and designed the digital LPF with MATLAB, universal simulation tools, for this study.

경수 및 공기중에서의 지르칼로이-4 튜브의 프레팅 마멸특성 비교 (A Comparison of Fretting Wear Characteristics of Zircaloy-4 Tube in Light Water and in Air)

  • 조광희;김태형;김석삼
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 1999년도 제29회 춘계학술대회
    • /
    • pp.303-309
    • /
    • 1999
  • The fretting wear behaviour of Zircaloy-4 tube used as the fuel rod cladding in PWR nuclear power plants has been investigated at the different test environment, in light water and in air as a function of slip amplitude, normal load, test duration and frequency. Zircaloy-4 tubes were used for both of oscillating and stationary specimens. A fretting wear tester was designed to be suitable for this fretting test. The wear volume and specific wear rate of Zircaloy-4 tube in water were greater than those in air under various slip amplitude. It was found that delaminate debris and surface cracks were observed at low slip amplitude and high load in water Experimental results showed that the light water accelerated the wear of Zircaloy-4 tube at low slip amplitude in fretting.

  • PDF

반도체 변압기를 위한 고압 IGBT의 스위칭 손실 특성 비교 (A Comparative Analysis of Switching Losses of High Voltage IGBTs in Solid State Transformer Applications)

  • 윤춘기;조영훈;김호성;백주원;조영표
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2016년도 전력전자학술대회 논문집
    • /
    • pp.107-108
    • /
    • 2016
  • Solid State Transformer(SST) has been recently regarded as a good alternative to conventional low frequency transformer. SST is consist of several high voltage power stage, so it is important to select optimal semiconductor switches for specification. This paper presents optimal IGBT switches for low switching losses using analyzing switching characteristics of several high voltage IGBT switches. Double Pulse Tester(DPT) experiment is used to verify characteristics of this IGBT switches.

  • PDF

BIST 기법을 이용한 RF 집적회로의 테스트용이화 설계 (Testable Design of RF-ICs using BIST Technique)

  • 김용;이재민
    • 디지털콘텐츠학회 논문지
    • /
    • 제13권4호
    • /
    • pp.491-500
    • /
    • 2012
  • 본 논문에서는 RF 송수신 시스템 칩 내부의 저잡음증폭기(LNA)와 전체 송수신기 시스템 테스트에 효과적인 새로운 루프백(Loopback) BIST 구조를 제안한다. 제안하는 테스트기법은 외부 테스트장비(Automatic Test Equipment)를 사용하는 기존의 테스트기법과 달리 테스트 모드에서 칩에 내장된 베이스밴드 프로세서를 테스터로 사용하므로써 테스트인가와 테스트평가등을 효율적으로 수행할 수 있는 장점을 갖는다. 높은 주파수의 테스트 출력신호는 낮은 주파수로 변환하여 베이스밴드 프로세서에서 평가하게 됨으로써 테스트용이도가 향상될 수 있다. 제안하는 테스트기법은 ATE와 같은 외부테스트장비의 필요를 최소화하고 테스트 시간과 비용을 줄여 결과적으로 칩 제조비용의 절감을 가능하게 해준다.

Cu박판의 초음파 금속 용착 실험을 통한 용착성 평가 (Evaluation of the Weldability of Cu Sheet through the Ultrasonic Metal Welding Experiment)

  • 박우열;장호수;김정호;박동삼
    • 한국생산제조학회지
    • /
    • 제21권4호
    • /
    • pp.613-618
    • /
    • 2012
  • The Ultrasonic metal welding is used in the solid-phase welding method at room temperature or low temperature state. In welding process, the high frequency vibration energy is delivered to the welding part under the constant pressure for welding. In this study, we aimed to design and manufacture a 40,000 Hz band horn through finite element analysis. By performing modal analysis and harmonic response analysis, the modal analysis result is that the horn frequency was 39,599Hz and the harmonic response result that the horn frequency was 39,533Hz. These results were similar. In order to observe the designed horn's performance, about 4,000 voltage data was obtained from a light sensor and was analyzed by FFT analysis using Origin Tool. The result RMS amplitude was approximately $8.5{\mu}m$ at 40,000Hz, and maximum amplitude was $12.3{\mu}m$. Using this manufactured horn along with an ultrasonic metal welder and tension tester, the weldability of Cu sheets was evaluated. The maximum tensile force was 66.53 N in the welding condition of 2.0 bar pressure, 60% amplitude, and 0.32 s welding time. In excessive welding conditions, it was revealed that weldability is influenced negatively.

Influence of Deposition Parameters on Film Hardness for Newly Synthesized BON Thin Film by Low Frequency R.F. PEMOCVD

  • G.C. Chen;J.-H. Boo;Kim, Y.J.;J.G. Han
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2001년도 춘계학술발표회 초록집
    • /
    • pp.73-73
    • /
    • 2001
  • Boron-containing materials have several excellent properties, such as superlnardness, insulation and non-Rinear optical property. Recently, oxynitride compounds, such as Si(ON), Ti(ON), became the promising materials applied in diffusion barrier layer and solar cell. With the expectation of obtaining the hybrid property, we have firstly grown the BON thin film by radio frequency (R.F.) plasma enhanced metalorganic chemical vapm deposition (PEMOCVD) with 100 kHz frequency and trimethyl borate precursor. The plasma source gases used in this study were Ar and $H_2$, and two kinds of nhmgen source gases, $N_2$ and <$NH_3$, were also employed. The as-grown films were characterized by XPS, IR, SEM and Knoop microlhardness tester. The relationship between the films hardness and the growth rate indicated that the hardness of the film was dependent on several factors such as nitrogen source gas, substrate temperature and film thickness due to the variation of the composition and the structure of the film. Both nitrogen and carbon content could raise the film hardness, on which nitrogen content did stronger effect than carbon. The smooth morphology and continuous structure was benefit of obtaining high hardness. The maximum hardness of BON film was about 10 GPa.

  • PDF