• 제목/요약/키워드: Low frequency probe data

검색결과 17건 처리시간 0.028초

Electromagnetic Micro x-y Stage for Probe-Based Data Storage

  • Park, Jae-joon;Park, Hongsik;Kim, Kyu-Yong;Jeon, Jong-Up
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제1권1호
    • /
    • pp.84-93
    • /
    • 2001
  • An electromagnetic micro x-y stage for probe-based data storage (PDS) has been fabricated. The x-y stage consists of a silicon body inside which planar copper coils are embedded, a glass substrate bonded to the silicon body, and eight permanent magnets. The dimensions of flexures and copper coils were determined to yield $100{\;}\mu\textrm{m}$ in x and y directions under 50 mA of supplied current and to have 440 Hz of natural frequency. For the application to PDS devices, electromagnetic stage should have flat top surface for the prevention of its interference with multi-probe array, and have coils with low resistance for low power consumption. In order to satisfy these design criteria, conducting planar copper coils have been electroplated within silicon trenches which have high aspect ratio ($5{\;}\mu\textrm{m}$in width and $30{\;}\mu\textrm{m}$in depth). Silicon flexures with a height of $250{\;}\mu\textrm{m}$ were fabricated by using inductively coupled plasma reactive ion etching (ICP-RIE). The characteristics of a fabricated electromagnetic stage were measured by using laser doppler vibrometer (LDV) and dynamic signal analyzer (DSA). The DC gain was $0.16{\;}\mu\textrm{m}/mA$ and the maximum displacement was $42{\;}\mu\textrm{m}$ at a current of 180 mA. The measured natural frequency of the lowest mode was 325 Hz. Compared with the designed values, the lower natural frequency and DC gain of the fabricated device are due to the reverse-tapered ICP-RIE process and the incomplete assembly of the upper-sided permanent magnets for LDV measurements.

  • PDF

표본 ADAS 차두거리 기반 연속류 시공간적 교통밀도 추정 (Spatiotemporal Traffic Density Estimation Based on Low Frequency ADAS Probe Data on Freeway)

  • 임동현;고은정;서영훈;김형주
    • 한국ITS학회 논문지
    • /
    • 제19권6호
    • /
    • pp.208-221
    • /
    • 2020
  • 본 연구는 첨단운전자보조시스템(Advanced Driver Assistance System, ADAS)이 빠르게 보급됨에 따라 표본 프로브 차량에 설치된 ADAS로부터 얻은 개별차량의 궤적 데이터와 전방차량과의 차두거리 데이터를 이용하여 연속류의 교통밀도를 추정 및 분석하는 것을 목적으로 한다. 과거 연속류 교통밀도는 주로 차량검지시스템(Vehicle Detection System, VDS)에서 수집되는 교통량, 속도, 점유율 등의 데이터를 가공하여 추정되거나, CCTV등의 영상정보를 활용하여 직접 차량 대수를 계수하여 추정되었다. 이러한 방식은 교통밀도 추정의 공간적 제약이 있고, 교통 혼잡시 추정의 신뢰도가 낮다는 한계를 보였다. 이에 본 연구에서는 선행연구의 한계를 극복하기 위해 ADAS로부터 수집된 개별차량 궤적 데이터와 차두거리 정보를 활용하여 도로의 공간을 검지하고 일반화된 밀도(Generalized Density)방식을 이용하여 시공간적 교통밀도를 추정한다. 이에 따라 ADAS차량의 표본율에 따른 교통밀도 추정의 정확도를 분석한 결과, 30%의 표본율일 경우 교통밀도 참 값과 약 90% 일치하는 것으로 나타났다. 이를 통해 본 연구는 향후 ADAS 및 자율주행차량이 혼재되는 도로 상황에서 신뢰도 높은 교통밀도 추정을 가능하게 하며 효율적인 교통운영관리에 기여할 수 있을 것으로 판단된다.

낙뢰 보호용 접지시스템 평가를 위한 고주파 접지임피던스 측정시스템의 설계 및 제작 (Design and Fabrication of High Frequency Ground Impedance Measuring System for Assessment of Grounding System for Lightning Protection)

  • 길형준;송길목;김영석;김종민;김영진
    • 한국안전학회지
    • /
    • 제31권3호
    • /
    • pp.47-52
    • /
    • 2016
  • This paper describes the design and fabrication of high frequency ground impedance measuring system for assessment of grounding system for Lightning protection. The ground impedance measuring system has been designed and fabricated which makes it possible to assess the ground impedance by frequency ranges from 100 Hz to 1 MHz. The effective grounding systems having a very low impedance to electromagnetic disturbance such as lightning surges and noises in microelectronics and high-technology branches are strongly required. In order to analyze the dynamic characteristic of grounding system impedances in lightning and surge protection grounding systems, it is highly desirable to assess the ground impedances as a measure of performance of grounding system in which lightning and switching surge currents with fast rise time and high frequency flow. The measuring system is based on the variable frequency power supply and consists of signal circuit part, main control part, data acquisition and processing unit, and voltage and current probe system. The ground impedance measuring system can be used to assess grounding system during occurrence of lightning.

Development of an Optical Tissue Clearing Laser Probe System

  • Yeo, Changmin;Kang, Heesung;Bae, Yunjin;Park, Jihoon;Nelson, J. Stuart;Lee, Kyoung-Joung;Jung, Byungjo
    • Journal of the Optical Society of Korea
    • /
    • 제17권4호
    • /
    • pp.289-295
    • /
    • 2013
  • Although low-level laser therapy (LLLT) has been a valuable therapeutic technology in the clinic, its efficacy may be reduced in deep tissue layers due to strong light scattering which limits the photon density. In order to enhance the photon density in deep tissue layers, this study developed an optical tissue clearing (OTC) laser probe (OTCLP) system which can utilize four different OTC methods: 1) tissue temperature control from 40 to $10^{\circ}C$; 2) laser pulse frequency from 5 to 30 Hz; 3) glycerol injection at a local region; and 4) a combination of the aforementioned three methods. The efficacy of the OTC methods was evaluated and compared by investigating laser beam profiles in ex-vivo porcine skin samples. Results demonstrated that total (peak) intensity at full width at half maximum of laser beam profile when compared to control data was increased: 1) 1.21(1.39)-fold at $10^{\circ}C$; 2) 1.22 (1.49)-fold at a laser pulse frequency of 5 Hz; 3) 1.64 (2.41)-fold with 95% glycerol injection; 4) 1.86 (3.4)-fold with the combination method. In conclusion, the OTCLP system successfully improved the laser photon density in deep tissue layers and may be utilized as a useful tool in LLLT by increasing laser photon density.

Electromagnetic interference(EMI) shielding efficiency(SE) charhcteristics of IMI multilayer/PMMA structure for plasma display panel(PDP) filter.

  • Lee, Jung-Hyun;Sohn, Sang-Ho;Cho, Yong;Lee, Sang-Gul
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2006년도 6th International Meeting on Information Display
    • /
    • pp.872-876
    • /
    • 2006
  • This study was made to examine the electromagnetic interference(EMI) shielding effect (SE) of multilayered thin films in which indium-tin oxide(ITO) and Ag were deposited alternately from 3layer to 9 layer on Poly Methyl Meth Acrylate(PMMA) substrate at room temperature using a PF sputtering. We measured optical and electrical characteristics by UV-spectrometer and 4 point probe. The measurement of EMI SE in frequency range from 50MHz to 1.5GHz was performed by using ASTM D4935-89 method. We compared the measured EMI SEs with theoretical simulation data. We obtained relatively low resistivity and high transmittance from the EMI SE multilayers. In this study, we obtain good optical electrical characteristics with a minimun transmittance of about 60% at 550nm wavelength and sheet resistance of $2{\sim}3ohm/sq$., respectivity. Measured EMI SEs were over 50dB and similar to theoretical simulation data.

  • PDF

2010년 여름철 수도권 집중관측기간 강수 사례들에서 나타나는 도시화 효과 (Effect of Urbanization on Rainfall Events during the 2010 Summer Intensive Observation Period over Seoul Metropolitan Area)

  • 김도우;김연희;김기훈;신승숙;김동균;황윤정;박종임;최다영;이용희
    • 한국지구과학회지
    • /
    • 제33권3호
    • /
    • pp.219-232
    • /
    • 2012
  • 도시화 효과가 여름 강수에 미치는 영향을 분석하기 위해 2010년 8월 13일부터 9월 3일까지 수도권 집중관측(ProbeX-2010)을 수행하였다. 분석 결과, 다음의 두 가지 현상들이 발견되었다. 첫째, 관측 기간 동안 약한 강수(${\leq}1\;mm\;hr^{-1}$)가 다른 지역보다 서울 풍하측 지역에서 더 자주 발생하였으며, 이는 최근 5년(2006-2010) 자료에서도 확인되었다. 약한 강수는 주로 서울 풍하측 산악 지역에서 야간에 더 자주 발생하였기 때문에 이는 도시지형 뿐만 아니라 산악 지형의 복합적인 효과로 여겨진다. 둘째, 간헐적으로 대류 시스템이 서울 풍하측에서 급격하게 발달해 호우를 야기했다. 이는 특히 8월 27일 1300-1500 KST의 일련의 레이더 영상에서 뚜렷하게 확인되었다. 본 연구에서는 이 강수 사례에 대한 종관 국지적 날씨 특성과 고층 대기 특성을 자세히 분석하였다. 그 결과 도시지형과 연관된 지표 현열 증가뿐만 아니라 조건부 불안정 대기 상태(특히 대기 하층)와 대기 하층의 습기 유입이 도시화 효과와 연관된 대류성 호우를 야기하는 중요한 요소로 제시되었다.

스마트폰 기본 동작 모드에 따른 저주파 대역 누설 전자파 신호 특성 분석 (Low-Frequency Electromagnetic Leakage Signal Analysis According to Fundamental Operations of Smartphones)

  • 이영준;박희선;권영현;이재기;최지은;조상우
    • 한국통신학회논문지
    • /
    • 제41권9호
    • /
    • pp.1108-1119
    • /
    • 2016
  • 본 논문에서는 스마트폰의 저주파 대역 누설 전자파가 미치는 악영향을 분석하기 위해 스마트폰 모델별로 기본 동작에 따라 누설되는 30 MHz 이하의 누설 전자파 신호의 스펙트럼 특성 및 방사 패턴을 분석하였다. 사용자와의 직접적인 인터페이스를 담당하는 스마트폰의 입출력 센서 모듈(터치스크린, 카메라, 마이크 및 스피커 모듈)을 활성화시키는 4가지 기본 동작 모드에 의해 누설되는 전자파 신호를 상용 Near-Field 마그네틱 프로브를 통해 1cm의 격자 간격으로 정밀하게 측정하였다. 측정된 누설 전자파 신호를 분석한 결과, 스마트폰의 모델 및 동작 모드별로 누설되는 저주파 대역 전자파는 특이한 피크(Peak) 또는 하모닉(Harmonic) 피크 성분을 보이며, 동작 모드에 따라 각각의 입출력 센서 모듈이 활성화될 경우 해당 센서 모듈 및 메인보드 상의 AP(Application Processor), 메모리 주위로 상대적으로 강한 저주파 대역의 전자파가 누설되는 것을 확인할 수 있었다.

An MMIC VCO Design and Fabrication for PCS Applications

  • Kim, Young-Gi;Park, Jin-Ho
    • Journal of Electrical Engineering and information Science
    • /
    • 제2권6호
    • /
    • pp.202-207
    • /
    • 1997
  • Design and fabrication issues for an L-band GaAs Monolithic Microwave Integrated Circuit(MMIC) Voltage Controlled Oscillator(VCO) as a component of Personal Communications Systems(PCS) Radio Frequency(RF) transceiver are discussed. An ion-implanted GaAs MESFET tailored toward low current and low noise with 0.5mm gate length and 300mm gate width has been used as an active device, while an FET with the drain shorted to the source has been used as the voltage variable capacitor. The principal design was based on a self-biased FET with capacitive feedback. A tuning range of 140MHz and 58MHz has been obtained by 3V change for a 600mm and a 300mm devices, respectively. The oscillator output power was 6.5dBm wth 14mA DC current supply at 3.6V. The phase noise without any buffer or PLL was 93dB/1Hz at 100KHz offset. Harmonic balance analysis was used for the non-linear simulation after a linear simulation. All layout induced parasitics were incorporated into the simulation with EEFET2 non-linear FET model. The fabricated circuits were measured using a coplanar-type probe for bare chips and test jigs with ceramic packages.

  • PDF

PAGAN I: MULTI-FREQUENCY POLARIMETRY OF AGN JETS WITH KVN

  • KIM, JAE-YOUNG;TRIPPE, SASCHA;SOHN, BONG WON;OH, JUNGHWAN;PARK, JONG-HO;LEE, SANG-SUNG;LEE, TAESEOK;KIM, DAEWON
    • 천문학회지
    • /
    • 제48권5호
    • /
    • pp.285-298
    • /
    • 2015
  • Active Galactic Nuclei (AGN) with bright radio jets offer the opportunity to study the structure of and physical conditions in relativistic outflows. For such studies, multi-frequency polarimetric very long baseline interferometric (VLBI) observations are important as they directly probe particle densities, magnetic field geometries, and several other parameters. We present results from first-epoch data obtained by the Korean VLBI Network (KVN) within the frame of the Plasma Physics of Active Galactic Nuclei (PAGaN) project. We observed seven radio-bright nearby AGN at frequencies of 22, 43, 86, and 129 GHz in dual polarization mode. Our observations constrain apparent brightness temperatures of jet components and radio cores in our sample to > 108.01 K and > 109.86 K, respectively. Degrees of linear polarization mL are relatively low overall: less than 10%. This indicates suppression of polarization by strong turbulence in the jets. We found an exceptionally high degree of polarization in a jet component of BL Lac at 43 GHz, with mL ~ 40%. Assuming a transverse shock front propagating downstream along the jet, the shock front being almost parallel to the line of sight can explain the high degree of polarization.

초음파영상에서 주파수와 파라미터를 이용한 정량적 영상평가 (Evaluation of Quantitative Image Quality using Frequency and Parameters in the Ultrasound Image)

  • 김창수;강세식;김정훈
    • 한국방사선학회논문지
    • /
    • 제10권4호
    • /
    • pp.247-253
    • /
    • 2016
  • 초음파 장비는 여러 질환을 진단하는 장비로서 널리 사용되고 있으나, 초음파영상 품질의 평가방법에서는 정량적 표준이 없는 실정이다. 따라서 본 연구에서는 ATS-539 다목적 팬텀 내 8 mm 표적의 파라미터로서 주파수, Dynamic range, 초점수를 변화하여 예민도의 SNR과 영상의 히스토그램을 분석하고 왜곡도를 측정하여 표적별 적합한 주파수 및 파라미터를 도출하여 초음파영상의 병변 진단율을 향상 하고자 한다. 실험재료는 초음파 장비, ATS-539 다목적 팬텀을 사용하며, 실험방법은 영상 평가 팬텀의 8 mm를 주파수(2, 3, 4 MHz, 하모닉 3, 4, 4.5 MHz), Dynamic range(58, 68, 78, 88, 98), Focus(2, 4, 6개)를 변화시키면서 85장의 영상을 획득한다. 8 mm 영상의 예민도를 Image J 프로그램에서 각 표적별 SNR을 측정하고, 왜곡도는 신호의 히스토그램에서 백그라운드 값을 뺄셈하여 측정한다. 측정 결과 값에서 상위 40% 결과에서 파라미터 변화에 따라 예민도의 SNR, 왜곡도의 변화양상의 데이터 값을 산출하여 초음파 장비에서 적절한 영상의 품질을 나타내는 파라미터를 도출하였다. 결과는 초점수가 증가하면 SNR이 높고 왜곡도가 감소하며, 주파수 4 MHz에서 SNR값이 높고 왜곡도가 감소하였다. 그리고 Dynamic range 88, 98에서 최적의 영상을 나타내었으며, 실험 결과값을 기초로 초음파영상의 품질을 평가한다면 보다 정확한 초음파 진단이 가능할 것으로 사료된다.