• 제목/요약/키워드: Low dose radiation

Search Result 938, Processing Time 0.023 seconds

A Study on the Adoption of Cyclotron Decommissioning Plan Criteria by the Analysis of Domestic Relocation and Abroad Dismantling Practices (국내 사이클로트론 이전 및 해외 해체 사례 분석을 통한 해체 계획 기준 도입 연구)

  • Woo, Rina;Kim, Yongmin;Song, Minchul;Cho, Daehyung;Lee, Jaesung;Kim, Wantae
    • Journal of Radiation Protection and Research
    • /
    • v.38 no.2
    • /
    • pp.91-99
    • /
    • 2013
  • There are many reasons for decommissioning of cyclotron such as not only age-related deficiency, any serious wear or damage but also relocation, upgrade and changing mission. Decommission of cyclotron in USA and EU give rise to a lot of low-level radioactive waste and costs. Various research on decommissioning of particle accelerator have been carried to reduce the cost of decommissioning in USA and EU. In USA, the NRC require DFP (Decommissioning Funding Plan) to authorized licenser by 10 CFR Part 30.35. To resolve radioactive waste problem and reduce the estimated cost of cyclotron decommissioning, we should consider technical aspects (decommissioning procedures, decontamination techniques, etc.) and safety aspects(residual radioactivity, the expected dose, etc) for decommissioning. In this study, we analyzed practical information on the decommissioning of cyclotron in ANL (Argonne National Laboratory) and Belgium (EU). And we investigated the experience on the cyclotron relocation from SNUH (Seoul National University Hospital) to SKKU (Sungkyunkwan University). From these results, we provide the basic data for establishing of relevant standards on domestic cyclotron decommissioning. It is necessary to adopt the DFP for safe and economic decommissioning and waste recycling. These result could be utilized for the establishment on the standards and useful requirements.

Atmospheric Dispersion Assessment for Potential Accidental Releases at Yonggwang Nuclear Power Plants (영광원전에서 가상 사고시 대기확산 평가)

  • Na, Man-Gyun;Sim, Young-Rok;Jung, Chul-Kee;Lee, Goung-Jin;Kim, Soong-Pyung;Chung, Sung-Tai
    • Journal of Radiation Protection and Research
    • /
    • v.25 no.2
    • /
    • pp.81-87
    • /
    • 2000
  • XOQ_DW code is currently used to assess the atmospheric dispersion fur the routine releases of radioactive gaseous effluents at Yonggwang nuclear power plants. This code was developed based on XOQDOQ code and an additional code is required to assess the atmospheric dispersion for potential accidental releases. In order to assess the atmospheric dispersion fer the accidental releases, XOQAR code has been developed by using PAVAN code that is based on Reg. Guide 1.145. The terrain data of XOQ_DW code inputs and the relative concentrations (X/Q) of XOQ_DW code outputs are used as the inputs of the XOQAR code through the interface with XOQ_DW code. By using this code, the maximum values of X/Q at exclusion area and low population zone boundaries except for sea areas were assessed as $1.33{\times}10^{-4}$ and $7.66{\times}10^{-6}$ sec/$m^3$, respectively. Through the development of this code, a rode system is prepared for assessing the atmospheric dispersion for the accidental releases as well as the routine releases. This developed code ran be used for other domestic nuclear power plants by modifying the terrain input data.

  • PDF

Development of Ice Cream with Improved Microbiological Safety and Acceptable Organoleptic Quality Using Irradiation (감마선 이용 미생물학적 및 관능적 품질이 우수한 아이스크림의 개발)

  • Kim, H.J.;Jang, A.;Ham, J.S.;Jeong, S.G.;Ahn, J.N.;Byun, M.W.;Jo, C.
    • Journal of Animal Science and Technology
    • /
    • v.49 no.4
    • /
    • pp.515-522
    • /
    • 2007
  • To develop the manufacturing method of ice cream with microbiologically safe and proper sensory quality using irradiation for sensitive consumer, 3 different flavors, which were resistant to their flavors against irradiation, were selected and used for ice cream manufacturing to reduce the irradiation-induced off-flavor problem. The general composition was not different among treatments. Total aerobic bacteria were detected as 2.38, 1.23, 1.38, and 1.15 log CFU/g level in ice cream with control(no flavor added), spearmint, mint, and citrus flavor, respectively. No viable cells were observed by irradiation at 1 kGy except for the control. Sensory evaluation indicated that the irradiated ice cream with spearmint flavor at 1 kGy and citrus flavor at 3 kGy had higher overall acceptability. Therefore, a low dose irradiation (less than 3 kGy) with mint or citrus flavors may enhance the safety of ice cream with proper sensory quality for sensitive consumer.

Radio-sensitivity of Human Colorectal Cancer Cell is Regulated by Potassium Cyanate (Potassium cyanate에 의해 조절되는 사람 대장암 세포의 방사선 감수성 변화)

  • Yang, Eun Ju;Chang, Jeong Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.1
    • /
    • pp.125-132
    • /
    • 2019
  • Potassium cyanate (KCN) is an inorganic reagent and can induce the post-translation carbamylation of proteins. The carbamylated reaction in the body is involved in cell death in various diseases. According the results in our previous study, KCN enhances the radiosensitivity of human colorectal cancer cell line, HCT 116 cells. However, it was not enough to confirm the mechanism that KCN works in these cells. To determinated the mechanisms of KCN in the cells with increased radiosensitivity, HCT 116 cells were treated KCN with low-dose gamma-radiation. And then, we examined alteration of the cell cycle, cell proliferation, cytokine level and the activation of cell signaling protein. As a result, cell cycle arrest and cell death were induced by the activation of caspase-3 and PARP in the irradiated cells with KCN treatment. These changes of the irradiated cell with KCN treatment were induced by the release of $TNF-{\alpha}$ via $NF-{\kappa}B$ activation. In conclusions, enhanced radio-sensitivity mediated by KCN induced cell death and it occurs by $NF-{\kappa}B$-dependent $TNF-{\alpha}$ production.

3DentAI: U-Nets for 3D Oral Structure Reconstruction from Panoramic X-rays (3DentAI: 파노라마 X-ray로부터 3차원 구강구조 복원을 위한 U-Nets)

  • Anusree P.Sunilkumar;Seong Yong Moon;Wonsang You
    • The Transactions of the Korea Information Processing Society
    • /
    • v.13 no.7
    • /
    • pp.326-334
    • /
    • 2024
  • Extra-oral imaging techniques such as Panoramic X-rays (PXs) and Cone Beam Computed Tomography (CBCT) are the most preferred imaging modalities in dental clinics owing to its patient convenience during imaging as well as their ability to visualize entire teeth information. PXs are preferred for routine clinical treatments and CBCTs for complex surgeries and implant treatments. However, PXs are limited by the lack of third dimensional spatial information whereas CBCTs inflict high radiation exposure to patient. When a PX is already available, it is beneficial to reconstruct the 3D oral structure from the PX to avoid further expenses and radiation dose. In this paper, we propose 3DentAI - an U-Net based deep learning framework for 3D reconstruction of oral structure from a PX image. Our framework consists of three module - a reconstruction module based on attention U-Net for estimating depth from a PX image, a realignment module for aligning the predicted flattened volume to the shape of jaw using a predefined focal trough and ray data, and lastly a refinement module based on 3D U-Net for interpolating the missing information to obtain a smooth representation of oral cavity. Synthetic PXs obtained from CBCT by ray tracing and rendering were used to train the networks without the need of paired PX and CBCT datasets. Our method, trained and tested on a diverse datasets of 600 patients, achieved superior performance to GAN-based models even with low computational complexity.

Study on the Institutional Control Period Through the Post-drilling Scenario Of Near Surface Disposal Facility for Low and Intermediate-Level Radioactive Waste (중·저준위 방사성폐기물 천층처분시설에서 시추 후 거주시나리오 평가를 통한 폐쇄 후 제도적 관리기간 연구)

  • Hong, Sung-Wook;Park, Jin-Baek;Yoon, Jung-Hyun
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.12 no.1
    • /
    • pp.59-68
    • /
    • 2014
  • The public's access to the disposal facilities should be restricted during the institutional control period. Even after the institutional control period, disposal facilities should be designed to protect radiologically against inadvertent human intruders. This study is to assess the effective dose equivalent to the inadvertent intruder after the institutional control period thorough the GENII. The disposal unit was allocated with different kind of radioactive waste and the effects of the radiation dose to inadvertent intruder were evaluated in accordance with the institutional control period. As a result, even though there is no institutional control period, all were satisfied with the regulatory guide, except for the disposal unit with only spent filter. However, the disposal unit with only spent filter was satisfied with the regulatory guide after the institutional control period of 300 years. But the disposal unit with spent filter mixed with dry active waste could shorten the institutional control period. So the institutional control period can be reduced through the mixing the other waste with spent filter in disposal unit. Therefore, establishing an appropriate plan for the disposal unit with spent filter and other radioactive waste will be effective for radiological safety and reduction of the institutional control period, rather than increasing the institutional control period and spending costs for the maintenance and conservation for the disposal unit with only spent filter.

Median Modified Wiener Filter for Noise Reduction in Computed Tomographic Image using Simulated Male Adult Human Phantom (시뮬레이션된 성인 남성 인체모형 팬텀을 이용한 전산화단층촬영 에서의 노이즈 제거를 위한 Median Modified Wiener 필터)

  • Ju, Sunguk;An, Byungheon;Kang, Seong-Hyeon;Lee, Youngjin
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.1
    • /
    • pp.21-28
    • /
    • 2021
  • Computed tomography (CT) has the problem of having more radiation exposure compared to other radiographic apparatus. There is a low-dose imaging technique for reducing exposure, but it has a disadvantage of increasing noise in the image. To compensate for this, various noise reduction algorithms have been developed that improve image quality while reducing the exposure dose of patients, of which the median modified Wiener filter (MMWF) algorithm that can be effectively applied to CT devices with excellent time resolution has been presented. The purpose of this study is to optimize the mask size of MMWF algorithm and to see the excellence of noise reduction of MMWF algorithm for existing algorithms. After applying the MMWF algorithm with each mask sizes set from the MASH phantom abdominal images acquired using the MATLAB program, which includes Gaussian noise added, and compared the values of root mean square error (RMSE), peak signal-to-noise ratio (PSNR), coefficient correlation (CC), and universal image quality index (UQI). The results showed that RMSE value was the lowest and PSNR, CC and UQI values were the highest in the 5 x 5 mask size. In addition, comparing Gaussian filter, median filter, Wiener filter, and MMWF with RMSE, PSNR, CC, and UQI by applying the optimized mask size. As a result, the most improved RMSE, PSNR, CC, and UQI values were showed in MMWF algorithms.

Myocardial Blood Flow Quantified by Low-Dose Dynamic CT Myocardial Perfusion Imaging Is Associated with Peak Troponin Level and Impaired Left Ventricle Function in Patients with ST-Elevated Myocardial Infarction

  • Jingwei Pan;Mingyuan Yuan;Mengmeng Yu;Yajie Gao;Chengxing Shen;Yining Wang;Bin Lu;Jiayin Zhang
    • Korean Journal of Radiology
    • /
    • v.20 no.5
    • /
    • pp.709-718
    • /
    • 2019
  • Objective: To investigate the association of myocardial blood flow (MBF) quantified by dynamic computed tomography (CT) myocardial perfusion imaging (MPI) with troponin level and left ventricle (LV) function in patients with ST-segment elevated myocardial infarction (STEMI). Materials and Methods: Thirty-five STEMI patients who successfully had undergone reperfusion treatment within 1 week of their infarction were consecutively enrolled. All patients were referred for dynamic CT-MPI. Serial high-sensitivity troponin T (hs-TnT) levels and left ventricular ejection fraction (LVEF) measured by echocardiography were recorded. Twenty-six patients with 427 segments were included for analysis. Various quantitative parameters derived from dynamic CT-MPI were analyzed to determine if there was a correlation between hs-TnT levels and LVEF on admission and again at the 6-month mark. Results: The mean radiation dose for dynamic CT-MPI was 3.2 ± 1.1 mSv. Infarcted territories had significantly lower MBF (30.5 ± 7.4 mL/min/100 mL versus 73.4 ± 8.1 mL/min/100 mL, p < 0.001) and myocardial blood volume (MBV) (2.8 ± 0.9 mL/100 mL versus 4.2 ± 1.1 mL/100 mL, p = 0.044) compared with those of reference territories. MBF showed the best correlation with the level of peak hs-TnT (r = -0.682, p < 0.001), and MBV showed a moderate correlation with the level of peak hs-TnT (r = -0.437, p = 0.026); however, the other parameters did not show any significant correlation with hs-TnT levels. As for the association with LV function, only MBF was significantly correlated with LVEF at the time of admission (r = 0.469, p = 0.016) and at 6 months (r = 0.585, p = 0.001). Conclusion: MBF quantified by dynamic CT-MPI is significantly inversely correlated with the level of peak hs-TnT. In addition, patients with lower MBF tended to have impaired LV function at the time of their admission and at 6 months.

Outcome of patients with neuroblastoma aged less than 1 year at diagnosis (진단 시 1세 이하인 신경모세포종 환자의 치료성적)

  • Suh, Jung Min;Lee, Sang Goo;Yoo, Keon Hee;Sung, Ki Woong;Koo, Hong Hoe;Kim, Ju Youn;Cho, Eun Joo;Lee, Suk Koo;Kim, Jhingook;Lim, Do Hoon
    • Clinical and Experimental Pediatrics
    • /
    • v.52 no.1
    • /
    • pp.93-98
    • /
    • 2009
  • Purpose : The purpose of this study was to evaluate the clinical characteristics and outcomes of patients with neuroblastoma aged less than 1 year. Methods : From January 1997 to December 2007, 41 patients aged less than 1 year were diagnosed with neuroblastoma. Patients were divided into 3 risk groups according to the stage of the disease and N-myc amplification. Low-risk patients underwent surgery with (stage 2) or without (stage 1) short-term chemotherapy. Intermediate-risk patients underwent chemotherapy and surgery with or without local radiation therapy. High-risk patients underwent chemotherapy, surgery, radiation therapy, and high-dose chemotherapy/autologous stem cell rescue (HDCT/ASCR). Results : While tumor relapse occurred in only 1 patient, 7 patients died of treatment-related toxicities. Causes of treatment- related death included infection during conventional chemotherapy in 5 patients and acute myocarditis during HDCT/ASCR in 2 patients. The overall 5-year survival (${\pm}$ standard error) and 5-year event-free survival (EFS) rates after diagnosis for all 41 patients were $82.8{\pm}5.9%$ and $80.0{\pm}$6.3%$, respectively, with a median follow-up of 58 (9-137) months. The 5-year EFS rates for low-risk, intermediate-risk, and high-risk patients were 100%, $68.4{\pm}10.8%$, and $66.7{\pm}19.3%$, respectively. Conclusion : Increased efforts to reduce infection-associated toxicity deaths during conventional chemotherapy are needed to further improve the survival of patients with neuroblastoma aged less than 1 year.

Adjuvant Radiotherapy Following Radical Hysterectomy and Bilateral Pelvic Lymph Node Dissection for the Uterine Cervical Cancer : Prognostic Factors and Failure Patterns (근칙적 절제술과 술후 방사선치료를 시행한 자궁경부암 환자의 치료성적, 예루인자와 실패양상)

  • Choi, Doo-Ho
    • Radiation Oncology Journal
    • /
    • v.15 no.4
    • /
    • pp.357-367
    • /
    • 1997
  • Purpose : To identify variable prognostic factors and analyse failure patterns in the uterine cervix cancer after radical operation and adjuvant radio-therapy, a retrospective analysis was undertaken. Materals and Methods : I analysed one hundred and twenty four patients with uterine cervix cancer, FIGO stage IB, IIA and IIB, treated with radical hysterectomy and pelvic lymph node dissection followed by adjuvant radio-therapy between May 1985 and May 1994. Minimum follow up period was 24 months. All of them were treated with full dose external radiotherapy with linear accelerator and/or high dese rate intracavitary radiation. Results : Overall 5 year survival rate and relapse free survival rate were $75.4\%,\;73.5\%$, respectively. Significant prognostic factors by relapse free survival were wall involvement thickness, lymph node location and number, parametrium involvement, tumor size, stage, uterine body involvement, vaginal resection margin involvement. By multivariate analysis, lymph node matastasis. tumor size and vaginal resection margin involvement were significant prognostic factos. Treatment related failure were 33 cases. Locoregional failure were more likely in the stage IIB, lymph node positive or vaginal resection margin positive patients whereas distant failures were relatively more frequent in stage IB, IIA and lymph node, vaginal resection negative patients. In stage IIB, 5 year relapse free survival rate was only $56\%$ and nine of twenty two patients recurred. Conculsion : Postoperative radiotherapy results are good for patients with relatively low risk factor. But the results are poor for patients with multiple, high risk factors or stage IIB. To control recurrence for patients with high risk factors, postoperative adjuvant radiotherapy is not sufficient treatment method. To raise control rate adding other methods such as radiosensitizing agent or chemotherapy is necessary and prospectively randomized study is needed for evaluation of postoperative radiotherapy efficacy and /or other methods. And it is reasonable to treat primary radical radiotherapy for patients with stage IIB cervical cancer instead of radical operation and adjuvant radiotherapy and/or chemotherapy regimen.

  • PDF