• 제목/요약/키워드: Low dose area

검색결과 196건 처리시간 0.026초

Influence of different boost techniques on radiation dose to the left anterior descending coronary artery

  • Park, Kawngwoo;Lee, Yongha;Cha, Jihye;You, Sei Hwan;Kim, Sunghyun;Lee, Jong Young
    • Radiation Oncology Journal
    • /
    • 제33권3호
    • /
    • pp.242-249
    • /
    • 2015
  • Purpose: The purpose of this study is to compare the dosimetry of electron beam (EB) plans and three-dimensional helical tomotherapy (3DHT) plans for the patients with left-sided breast cancer, who underwent breast conserving surgery. Materials and Methods: We selected total of 15 patients based on the location of tumor, as following subsite: subareolar, upper outer, upper inner, lower lateral, and lower medial quadrants. The clinical target volume (CTV) was defined as the area of architectural distortion surrounded by surgical clip plus 1 cm margin. The conformity index (CI), homogeneity index (HI), quality of coverage (QC) and dose-volume parameters for the CTV, and organ at risk (OAR) were calculated. The following treatment techniques were assessed: single conformal EB plans; 3DHT plans with directional block of left anterior descending artery (LAD); and 3DHT plans with complete block of LAD. Results: 3DHT plans, regardless of type of LAD block, showed significantly better CI, HI, and QC for the CTVs, compared with the EB plans. However, 3DHT plans showed increase in the $V_{1Gy}$ at skin, left lung, and left breast. In terms of LAD, 3DHT plans with complete block of LAD showed extremely low dose, while dose increase in other OARs were observed, when compared with other plans. EB plans showed the worst conformity at upper outer quadrants of tumor bed site. Conclusion: 3DHT plans offer more favorable dose distributions to LAD, as well as improved target coverage in comparison with EB plans.

X-ray 저선량 피폭방지를 위한 기능성 차폐크림의 방어 효과 검증 (Verification of the Protective Effect of Functional Shielding Cream for the Prevention of X-ray Low-dose Exposure)

  • 김선칠
    • 한국방사선학회논문지
    • /
    • 제17권4호
    • /
    • pp.497-506
    • /
    • 2023
  • 의료기관의 방사선 업무 종사자의 경우 환자 보호와 정확한 시술을 위해 방사선 노출이 이루어져 저선량 피폭의 문제점을 안고 있다. 저선량 방사선 피폭은 주로 Apron 영역 이외에 신체 부분에서 발생되며, 가장 많은 곳이 손 등 피부이다. 특히, 의료인의 손은 시술 중 감각과 미세한 동작을 필요로 하기에 방사선 노출영역에서는 무방비 상태로 피폭의 위험성을 안고 있다. 납장갑 등 차폐체로 문제를 해결할 수 있지만, 이는 시술 중 손의 활동성을 제안하여 사용상의 어려움이 있다. 이러한 문제점을 해결하고자 기능성 방사선 보호효과를 얻을 수 있는 차폐크림을 개발하여 납당량 0.1 mmPb와 차폐성능을 비교하였다. 차폐크림 제조과정에서 크림의 밀도를 높이기 위해 기공을 줄이는 탈포과정을 추가하여 차폐성능을 개선하였다. 따라서 황산바륨을 주 재료로 사용한 차폐크림은 납 plate보다 차폐율이 낮은 실효에너지 영역에서는 59%, 높은 실효에너지에서는 37% 정도의 차이는 보여 기능성 방사선 방어효과가 있는 것으로 나타났다. 따라서 피부에 직접 사용할 수 있는 장점으로 상시 방어효과와 수술용 장갑 착용전에 사용이 가능한 것으로 사료된다.

Diagnostic Efficacy and Safety of Low-Contrast-Dose Dual-Energy CT in Patients With Renal Impairment Undergoing Transcatheter Aortic Valve Replacement

  • Suyon Chang;Jung Im Jung;Kyongmin Sarah Beck;Kiyuk Chang;Yaeni Kim;Kyunghwa Han
    • Korean Journal of Radiology
    • /
    • 제25권7호
    • /
    • pp.634-643
    • /
    • 2024
  • Objective: This study aimed to evaluate the diagnostic efficacy and safety of low-contrast-dose, dual-source dual-energy CT before transcatheter aortic valve replacement (TAVR) in patients with compromised renal function. Materials and Methods: A total of 54 consecutive patients (female:male, 26:38; 81.9 ± 7.3 years) with reduced renal function underwent pre-TAVR dual-energy CT with a 30-mL contrast agent between June 2022 and March 2023. Monochromatic (40- and 50-keV) and conventional (120-kVp) images were reconstructed and analyzed. The subjective quality score, vascular attenuation, contrast-to-noise ratio (CNR), and signal-to-noise ratio (SNR) were compared among the imaging techniques using the Friedman test and post-hoc analysis. Interobserver reliability for aortic annular measurement was assessed using the intraclass correlation coefficient (ICC) and Bland-Altman analysis. The procedural outcomes and incidence of post-contrast acute kidney injury (AKI) were assessed. Results: Monochromatic images achieved diagnostic quality in all patients. The 50-keV images achieved superior vascular attenuation and CNR (P < 0.001 in all) while maintaining a similar SNR compared to conventional CT. For aortic annular measurement, the 50-keV images showed higher interobserver reliability compared to conventional CT: ICC, 0.98 vs. 0.90 for area and 0.97 vs. 0.95 for perimeter; 95% limits of agreement width, 0.63 cm2 vs. 0.92 cm2 for area and 5.78 mm vs. 8.50 mm for perimeter. The size of the implanted device matched CT-measured values in all patients, achieving a procedural success rate of 92.6%. No patient experienced a serum creatinine increase of ≥ 1.5 times baseline in the 48-72 hours following CT. However, one patient had a procedural delay due to gradual renal function deterioration. Conclusion: Low-contrast-dose imaging with 50-keV reconstruction enables precise pre-TAVR evaluation with improved image quality and minimal risk of post-contrast AKI. This approach may be an effective and safe option for pre-TAVR evaluation in patients with compromised renal function.

DEVELOPMENT OF THE DUAL COUNTING AND INTERNAL DOSE ASSESSMENT METHOD FOR CARBON-14 AT NUCLEAR POWER PLANTS

  • Kim, Hee-Geun;Kong, Tae-Young;Han, Sang-Jun;Lee, Goung-Jin
    • Journal of Radiation Protection and Research
    • /
    • 제34권2호
    • /
    • pp.55-64
    • /
    • 2009
  • In a pressurized heavy water reactor (PHWR), radiation workers who have access to radiation controlled areas submit their urine samples to health physicists periodically; internal radiation exposure is evaluated by the monitoring of these urine samples. Internal radiation exposure at PHWRs accounts for approximately 20 $\sim$ 40% of total radiation exposure; most internal radiation exposure is attributed to tritium. Carbon-14 is not a dominant nuclide in the radiation exposure of workers, but it is one potential nuclide to be necessarily monitored. Carbon-14 is a low energy beta emitter and passes relatively easily into the body of workers by inhalation because its dominant chemical form is radioactive carbon dioxide ($^{14}CO_2$). Most inhaled carbon-14 is rapidly exhaled from the worker's body, but a small amount of carbon-14 remains inside the body and is excreted by urine. In this study, a method for dual analysis of tritium and carbon-14 in urine samples of workers at nuclear power plants is developed and a method for internal dose assessment using its excretion rate result is established. As a result of the developed dual analysis of tritium and carbon-14 in urine samples of radiation workers who entered the high radiation field area at a PHWR, it was found that internal exposure to carbon-14 is unlikely to occur. In addition, through the urine counting results of radiation workers who participated in the open process of steam generators, it was found that the likelihood of internal exposure to either tritium or carbon-14 is extremely low at pressurized water reactors (PWRs).

Co60 Gamma-Ray Effects on the DAC-7512E 12-Bit Serial Digital to Analog Converter for Space Power Applications

  • Shin, Goo-Hwan
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권6호
    • /
    • pp.2065-2069
    • /
    • 2014
  • The DAC-7512E is a 12-bit digital to analog converter that is low power and a single package with internal buffers. The DAC-7512E takes up minimal PCB area for applications of space power electronics design. The spacecraft mass is a crucial point considering spacecraft launch into space. Therefore, we have performed a TID test for the DAC-7512E 12-bit serial input digital to analog converter to reduce the spacecraft mass by using a low-level Gamma-ray irradiator with $Co^{60}$ gamma-ray sources. The irradiation with $Co^{60}$ gamma-rays was carried out at doses from 0 krad to 100 krad to check the error status of the device in terms of current, voltage and bit error status during conversion. The DAC-7512E 12-bit serial digital to analog converter should work properly from 0 krad to 30 krad without any error.

유전성 비만 마우스에 대한 아프리칸 망고 추출물의 항비만 효과 (Anti-obesity Effects of African Mango (Irvingia gabonesis, IGOB 131TM) Extract in Leptin-deficient Obese Mice)

  • 이민희;남다은;김옥경;심태진;김지훈;이정민
    • 한국식품영양과학회지
    • /
    • 제43권10호
    • /
    • pp.1477-1483
    • /
    • 2014
  • 본 연구에서는 유전성 비만 마우스를 이용하여 아프리칸 망고 추출물의 항비만 효과를 알아보고자 하였다. 기존의 연구 내용을 아프리칸 망고 추출물의 섭취 농도를 식이의 1%와 2%로 정하고, AIN93G diet에 아프리칸 망고 추출물 분말을 1%와 2% 섞어 diet를 제작하였다. 실험 식이를 8주간 제공한 후 실험 종료 시 실험군들의 체중 변화는 ob/ob군에 비해 유의적으로 감소하였다. 실험동물의 간 및 지방조직의 무게를 측정한 결과 간의 무게와 지방조직의 무게가 ob/ob군에 비해 유의적으로 감소하였다. 실험동물의 혈청 지질 함량은 TG, TC, LDL-콜레스테롤이 ob/ob군에 비해 감소하였으나 유의성은 나타나지 않았고, HDL-콜레스테롤은 고농도 섭취 시 ob/ob군에 비해 유의적으로 증가하였다. Adiponectin 유전자의 발현은 ob/ob군이 가장 낮았고, 실험식이 섭취군들은 ob/ob군에 비해 유의적으로 증가하였다. Adipogenic enzyme과 transcription factor인 FAS, LPL, PPAR-${\gamma}$, C/EBP, SREBP 유전자의 발현은 ob/ob군이 가장 높게 나타났고, 실험식이 섭취군들은 ob/ob군에 비해 유의적으로 낮았다. 전반적으로 본 실험에서는 아프리칸 망고 추출물이 leptin 유전자가 결핍된 비만 동물 모델에서 체중 감소 및 혈청 지질 함량을 개선시켜 주는 효과가 있고, adipogenic enzyme과 transcription factor 조절에 유익한 효과가 나타났다. 이러한 결과로부터 아프리칸 망고 추출물이 항비만 효과를 가진 천연 기능성 식품의 개발에 있어 기초자료로 활용할 수 있을 것으로 기대할 수 있다.

치과 방사선 검사 시 노출 위험성에 따른 피폭선량 방어연구 (The Study for Radio Protection According to a Possible Danger of Exposure During dental X-ray Examination)

  • 임청환;김승철;정홍량;홍동희;유인규;정천수
    • 한국방사선학회논문지
    • /
    • 제5권5호
    • /
    • pp.237-244
    • /
    • 2011
  • 일반적으로 저 에너지 방사선 조사로 검사하게 되는 치과 영역에서는 투과력이 약해 인체에 흡수되는 양이 많다. 치과 영역에서 방사선검사 시 부득이하게 방사선 노출을 받게 되는 방사선 작업종사자나 환자의 보호자가 위치와 거리에 따른 방사선 피폭 선량의 감소 방안을 알아보고자 한다. 진단용 발생장치인 GX-770, CRANEX TOME CEPH와 조사선량 측정기인 Ion chamber model 2026c, Reader기 20X6-1800을 사용하여 구강내 검사와 구강외 검사의 각각 검사실과 조정실에서의 관전압의 변화, 관전류와 조사시간의 변화, 조사방향의 변화에 따라 선량을 측정하였다. 그 결과 최고선량이 검사실 안에서는 평균 702.8 ${\mu}R$으로 측정 되었으며, 조정실 안에서 측정하였을 경우 20 ${\mu}R$이하의 낮은 선량을 보였으며, 120cm 거리에서 후방검사보다 측방검사가 낮은 선량으로 나타났다. 방사선검사시 위치와 거리에 따른 조사선량을 비교 분석하여, 적절한 거리 확보와 조사되는 중심방사선을 기준으로 측방($90{\sim}135^{\circ}$)에 위치함으로써 방사선 방어에 도움을 줄 것이며, 차폐문을 이용하여 방사선 피폭으로부터 감소 효과를 볼 수 있을 것이다.

광자선의 소조사면에서의 3차원적 선량 측정 (3-Dimensional Dosimetry of Small Field Photon Beam)

  • 장지선;권수일
    • 한국의학물리학회지:의학물리
    • /
    • 제23권1호
    • /
    • pp.54-61
    • /
    • 2012
  • 중합체 겔 선량계를 제작하여 사이버나이프의 광자선의 소조사면에서의 3차원적 선량측정 실험을 수행하였다. 겔 선량계는 아크릴로 제작된 두경부 팬텀내에 설치하여 선량측정에 사용하였다. 두경부 팬텀의 영상은 사이버나이프의 두경부 환자 치료를 위해 사용하는 전산화단층촬영장치(CT)의 프로토콜을 사용하여 획득하였고 치료계획 시스템에 전달되었다. 겔 선량계에 치료계획에서 수립한 방사선을 조사하였으며, 24시간 경과 후에 선량분석을 위하여 3.0T 자기공명영상장치(MRI)로 영상을 획득하였다. 측정된 겔 팬텀의 선량분포는 MATLAB을 이용하여 분석하였고 측정된 결과를 치료계획에서의 계산값과 비교하였다. 선량분포는 축상(axial) 방향의 등선량곡선의 80% 고선량 영역에서 치료계획 선량곡선과 측정된 선량곡선과의 차이가 0.76 mm이었으며, 40% 저선량 영역에서는 차이가 1.29 mm로 저선량 영역보다 고 선량영역에서 잘 일치함을 알 수 있었다. 본 연구에서 중합체 겔 선량계와 자기공명영상을 이용하여 소조사면에 대해 3차원적으로 선량을 분석할 수 있을 뿐 아니라 치료방사선 정도관리에도 활용될 수 있는 가능성을 확인하였다.

저 에너지 X선 조사 시 PMMA 팬텀 내의 흡수선량 평가를 위한 몬테카를로 시뮬레이션 (Monte Carlo Simulation for absorbed dose in PMMA phantom during the low-energy X-ray irradiation)

  • 김상태;강상구;김종일
    • 한국방사선학회논문지
    • /
    • 제5권6호
    • /
    • pp.383-389
    • /
    • 2011
  • Geant4와 DICOM 파일의 연동을 이용한 몬테카를로 시뮬레이션을 통해 실제 환자의 흡수선량을 산출하는 새로운 방법을 제시하고, Geant4 계산코드의 검증을 위해 MOSFET 선량계를 이용하여 PMMA 모의 팬텀 깊이에 따른 중심에서의 흡수선량 실측값과 Geant4 시뮬레이션 결과값을 비교하였다. PMMA slab의 불완전한 압착으로 인해 발생한 불균등한 간격의 공기층이 존재하지 않은 부분에서는 X선 조사야 $15{\times}15cm^2$$20{\times}20cm^2$에서 각각 $0.46{\pm}4.69%$$-0.75{\pm}5.19%$로 나타났다. PMMA 모의 팬텀의 불완전한 압착에 의해 나타난 오차를 제외하면 Geant4와 DICOM 파일의 연동을 통한 몬테카를로 시뮬레이션에 의한 계산값이 잘 일치함을 알 수 있다.

실험적 간 발암모델에서 감마선 조사 돼지고기 섭취가 전암성병변의 생성, 약물대사 효소계 및 소포체 막 안정성에 미치는 영향 (Effects of $\Upsilon$-Irradiated Pork Feeding on Preneoplastic Hepatic Lesion, Cytochrome P450 System and Microsome Glucose 6-Phosphatase Activity in Rat Hepatocarcinogenesis)

  • 김미정;김정희
    • Journal of Nutrition and Health
    • /
    • 제35권6호
    • /
    • pp.643-649
    • /
    • 2002
  • This study was done to investigate effects of ${\gamma}$-irradiated pork feeding on the formation of glutathione S-transferase placental form positive (GST-P$^{+}$) foci, lipid peroxidation, cytochrome P450 system and microsomal glucose 6-phosphatase activity in diethylnitrosamine (DEN)-initiated rat hepatocarcinogenesis. Weaning Sprague-Dawley male rats were fed the diet containing ${\gamma}$-irradiated ground pork at the dose of 0, 3, 10, 30 kGy as a 20% of protein source for 8 weeks. One week after feeding, rats were intraperitoneally injected twice with a dose of DEN (50 mg/kg BW). As a promote.,0.05%phenobarbital was fed in drinking water from one week after DEN treatment until the end of experiment. At the end of 8th week, rats were sacrificed and hepatic GST-P$^{+}$ foci, microsomal malondialdehyde (MDA) and conjugated diene contents were determined. In addition, cytochrome P450 content and the activities of NADPH cytochrome P450 reductase and glucose 6-phosphatase were also measured. There was no significant effect by gamma irradiation on microsomal MDA content, conjugated diene, cytochrome P450 content and activities of NADPH cytochrome P450 reductase and glucose 6-phosphatase. However with DEN treatment, microsomal MDA content showed a increasing tendency. Cytochrome P450 content was also significantly increased while microsomal glucose 6-phophatase activity was significantly decreased with DEN treatment. However the activity of NADPH cytochrome P450 reductase was not affected. An interesting finding in this study was that the number and area of hepatic GST-P$^{+}$ foci of rats fed gamma irradiated pork were tended to be decreased by high dose of irradiation, but were not significantly different. These results might imply that the consumption of low dose of gamma irradiated pork does not affect the formation of hepatic GST-P$^{+}$ foci and lipid peroxide and membrane stability.ability.