• 제목/요약/키워드: Low density polyethylene

검색결과 422건 처리시간 0.027초

지중배전케이블 기저수지의 수증기 투과 전달특성 (Chararcteristics of Water Vapor Transmission in Base Resin for Underground Residential Distribution Power Cable)

  • 송재주;한병성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 춘계학술대회 논문집 기술교육전문연구회
    • /
    • pp.149-153
    • /
    • 2003
  • In URD(Underground Residential Distribution) power cable, experiments of WVT(Water Vapor Transmission) test on the Base Resin accomplished to specimens which contained CB(Carbon Black), anti-oxidant to base resin and made by pressing to resin of pellet or lump form. a kind of specimens was HDPE(High Density Polyethylene), MDPE(Medium Density Polyethylene), LDPE(Low Density Polyethylene), LLDPE(Linear Low Density Polyethylene), PVC(Polyvinyl Chloride). as a results of WVT test, we saw that WVT ratio was HDPE < LLDPE < MDPE≒LDPE${\ll}$ PVC. WVT properties of PVC using for jacket showed properties 15-20 times more than MDPE or LLDPE. Therefore, to development of watertightness cable, our works present need of Changing in insulating materials.

  • PDF

자켓 컴팍운드용 절연재의 수증기투과 및 절연파괴 특성 (Characterization of Water Vapor Transmission & Dielectric Breakdown in Insulation Materials for Jacket Compound)

  • 송재주;한재홍;송일근;한용희;한병성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집
    • /
    • pp.52-56
    • /
    • 2001
  • Experiments of 2 type on insulating compounds accomplished to change PVC using in URD(Underground) power cable jacketing. one was DB(Dielectric Breakdown) test on the pure base resins and the others were WVT(Water Vapor Transmission) test on the compounds which contained C/B(Carbon Black), anti-oxidant to base resin. a kind of specimens made by pressing to resin of pellet or lump form was HDPE(High Density Polyethylene), MDPE(Medium Density Polyehylene), LDPE(Low Density Polyethylene), LLDPE(Linear Low Density Polyethylene), PVC(Polyvinyl Chloride). As a results of AC DB and WVT test, we saw that strength of Insulation was HDPE> LLDPE = MDP E> LDPE and WVT ratio was HDPE

  • PDF

n-butyl acrylate로 그라프트된 폴리에틸렌의 부분방전 특성 (Partial Discharge Characteristics of n-butyl acrylate grafted Polyethylenes)

  • 이정원;서광석;곽희로
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1997년도 추계학술대회 논문집
    • /
    • pp.489-492
    • /
    • 1997
  • Partial discharge characteristics of normal butyl acrylate grafted low density polyethylenes were investigated by an ultrasonic sensor made of ceramic piezoelectric material. It was found that the partial discharging activities in normal butyl acrylate grafted low density polyethylenes were considerably suppressed compared to those in plain low density polyethylene. It was found that acrylic acid grafted polyethylene was more effective than normal butyl acrylate grafted low density polyethylene.

  • PDF

Polyethylene 계열 절연재료의 환경적·기계적 특성 (Wet Environmental and Mechanical Characteristics for Polyethylene-based Insulating Materials)

  • 송우창;최원석;박하용
    • 전기학회논문지P
    • /
    • 제63권2호
    • /
    • pp.119-123
    • /
    • 2014
  • In this study, four kinds of specimens of PE(polyethylene)-based insulating materials were prepared for selecting the optimum insulation materials in a wet environment. The specimens were tested by various methods, the anti tracking test, the transmittance test in the water vapor transmittance(WVT) and the abrasion resistive test, etc. The HDPE(high-density polyethylene) specimen was showed excellent property in the tracking resistance test and the lowest transmittance in water vapor transmittance test. In the abrasion resistive test, the LLDPE(linear low-density polyethylene) and MDPE(medium-density Polyethylene) were showed excellent mechanical properties. The value of cut-through resistance for MDPE and HDPE were superior to that for LLDPE and LDPE(low-density polyethylene).

자켓 컴파운드용 절연재의 수증기투과 및 절연파괴 특성 (Characterization of Water Vapor Transmission & Dielectric Breakdown in Insulation Materials for Jacket Compound)

  • 송재주;한재홍;송일근;한용희;한병성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집 Vol.14 No.1
    • /
    • pp.52-56
    • /
    • 2001
  • Experiments of 2 type on insulating compounds accomplished to change PVC using in URD(Underground) power cable jacketing. one was DB (Dielectric Breakdown) test on the pure base resins and the others were WVT(Water Vapor Transmission) test on the compounds which contained C/B(Carbon Black), anti-oxidant to base resin. a kind of specimens made by pressing to resin of pellet or lump form was HDPE(High Density Polyethylene), MDPE(Medium Density Polyehylene), LDPE(Low Density Polyethylene), LLDPE(Linear Low Density Polyethylene), PVC (Polyvinyl Chloride). As a results of AC DB and WVT test, we saw that strength of Insulation was HDPE > LLDPE ≒ MDPE > LDPE and WVT ratio was HDPE < LLDPE < MDPE < LLDPE ≒ LDPE${\ll}$PVC. WVT of PVC using for jacket showed characteristic 15 times more than MDPE or LLDPE. Therefore, to development of watertightness cable, our works present need of Changing in insulating materials

  • PDF

高分子物質의 熱分解에 關한 硏究 (第4報) Polyethylene 및 Polypropylene의 熱分解에 關하여 (On the Pyrolysis of Polymers IV. Pyrolysis of Polythylene and Polypropylene)

  • 성좌경;노익삼;김정엽;장성봉
    • 대한화학회지
    • /
    • 제7권2호
    • /
    • pp.122-127
    • /
    • 1963
  • Pyrolysis fo polyethylene and polypropylene has been studied in order to clarify the mechanism of chain scission and effect of oxygen on degradation. Rate of weight decrease was measured under nitrogen and air atmosphere at constant temperature for the samples of high density polyethylene, low density polyethylene and isotactic polypropylene, and then gaseous hydrocarbons produced from pyrolysis were analysed by gas chromatography. Although there is little substantial difference between composition of hydrocarbon gases from pyrolysis of high density polyethylene and low density polyethylene except some difference in quantity of total gas produced, gas composition from polypropylene pyrolysis differs from that of polyethylene pyrolysis. Gases from pyrolysis under air contain much more unsaturated hydrocarbons than those from pyrolysis under inert gas.

  • PDF

메탈로센 선형 저밀도 폴리에틸렌/선형 저밀도 폴리에틸렌 블렌드의 결정화 거동 (Crystallization Characteristics of Metallocene Low Density Polyethylene/Low Density Polyethylene Blends)

  • 김경룡;한정우;강호종
    • 폴리머
    • /
    • 제25권6호
    • /
    • pp.840-847
    • /
    • 2001
  • 메탈로센 촉매로 제조된 메탈로센 선형 저밀도 폴리에틸렌(m-LLDPE)과 Ziegler-Natta 촉매에 의하여 제조된 선형 저밀도 폴리에틸렌(LLDPE) 블렌드의 결정화 거동을 고찰하여 보았다. 특히 블렌딩이 이들의 결정화 induction time 및 구정성장 속도 그리고 최대 구정의 크기에 미치는 영향을 중점적으로 살펴보았다. LLDPE/LDPE 블렌드와는 달리 LLDPE에 m-LLDPE를 블렌딩할 경우, 각각의 결정 형성 대신 하나의 결정이 형성됨을 확인하였으며 induction time이 현저히 짧아짐을 알 수 있었다. 하지만 이러한 감소는 블렌드의 조성비에는 크게 영향을 받지 않았다. 또한 블렌딩에 의하여 LLDPE의 구정성장 속도가 증가함을 확인할 수 있었으며, 구정의 최대 크기는 induction time과 구정성장 속도가 LLDPE에 미치는 영향에 따라 달라짐을 알 수 있었다.

  • PDF

열유도 상분리에 의한 선형 저밀도 폴리에틸렌 입자 제조에 관한 연구 (A Study on the Preparation of a Linear Low Density Polyethylene particles by Thermally Induced Phase Separation)

  • 박근호;장영민
    • 한국응용과학기술학회지
    • /
    • 제28권4호
    • /
    • pp.386-392
    • /
    • 2011
  • We are crystallized to the linear low density polyethylene(LLDPE) particles by a thermally induced phase separation(TIPS). TIPS process based on the phase separation mechanism was performed for the LLDPE system which undergoes liquid-solid phase separation. The linear low density polyethylene particle formation occurred by the nucleation and growth mechanism in the metastable region. Although the growth rates depended on the experimental conditions such as the polymer concentration and temperature, the particles were larger when the polymer concentration was higher or temperature was higher. The particles were observed by SEM. The LLDPE particle size distribution became broader when the polymer concentration was higher.

메타로센 촉매를 이용한 저밀도 폴리에틸렌의 전기적 특성 (Electrical Properties Low-Density Polyethylene by use of Metallocene Catalyst)

  • 조돈찬;;;홍진웅
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 하계학술대회 논문집
    • /
    • pp.123-127
    • /
    • 2000
  • In order to investigate the influence of manufacturing process on the electrical properties, we used two kinds of low density polyethylene prepared using metallocene catalyst (mL), linear low density polyethylene prepared using Ziegler catalyst (LL) and low density polyethylene by high pressure process (LD). mL has the narrowest composition and molecular weight distributions. We measured the dc and impulse breakdown strengths and current densities at 3$0^{\circ}C$, 6$0^{\circ}C$ and 9$0^{\circ}C$. mL had a higher breakdown strength and a lower high-field current than LD and LL. These results were discussed from the point of manufacturing processes.

  • PDF

창란젓갈의 포장에 관한 연구 -2. 파우치 포장 젓갈의 품질유지기한- (A Study in Packing of Changran-Jeotgal -2. Shelf-life a Plastic Pouch racking of Changran-Jeotgal-)

  • 윤지혜;이원동;장동석;강지희;이명숙
    • 한국수산과학회지
    • /
    • 제35권1호
    • /
    • pp.15-20
    • /
    • 2002
  • 신제조기법과 재래식방법으로 제조된 창란젓갈을 시험구와 대조구로하여 이들을 파우치 포장하여 각각 10, 20 및 $30^{\circ}C$에 저장하면서 품질변화를 조사하였다. 창란젓갈의 파우치포장 low density polyethylene (PE), poly-ethylene terephthalate/polyethylene/linear low density polyethylene (PET), polyethylene/nylon/linear low density polyethylene (PE/Ny)에서 시험구와 대조구 모두 저장온도가 높을수록 파우치 포장의 $CO_2$, 발생과 부피 팽창속도가 가속화되었으며, 부피팽창 속도는 PE/Ny, PET, PE 순으로 빨랐다. 한편, pH, L값, VBN의 변화속도는 PE가 가장 빨랐으며 그 다음이 PET, PE/Ny의 순으로 나타났으며, 저장 전 구간에 있어서 시험구가 대조구에 비하여 변화속도가 완만하였다. 포장재별로 각 온도에서 저장한 창란젓갈의 생균수변화를 조사한 결과 온도가 높을수록, 대조구가 시험구보다 생균수 증가가 빨랐다. 일반적으로 젓갈 포장에 사용되고 있는 PE의 경우 PET나 PE/Ny에 비하여 필름의 가스투과성이 높아 호기성 미생물의 증식을 촉진시키는 것으로 나타나 PET나 PE/Ny 파우치 포장으로 대체되어야 함을 알 수 있었다. 창란젓갈 파우치포장의 관능검사에서 상품성이 유지되는 품질기준을 6.0 이상으로하여 품질유지기한을 설정하였을 때, $10^{\circ}C$에서PE, PET, PE/Ny 포장의 품질유지 기한은 대조구가 20일, 40일, 40일인데 비하여 시험구는 40일, 50일, 60일로 나타나 10$\~$20일 정도 연장되었다. 따라서 이상의 결과를 바탕으로 하여 창란젓갈 저장시 품질측정변수에 대한 상관관계를 조사한 결과 파우치포장에서는 파우치의 부피, pH, L값, 휘발성염기질소 (VBN), 관능검사 등이 상관관계가 높아 젓갈 포장에서 품질지표항목으로 이용할 수 있을 것으로 기대된다.