• 제목/요약/키워드: Low concentration

검색결과 8,624건 처리시간 0.041초

Effect of Different Salt Concentrations and Temperatures on the Lactic Acid Fermentation of Radish Juice

  • Kim, Soon-Dong;Kim, Mee-Kyung;Ku, Yeun-Soo
    • Preventive Nutrition and Food Science
    • /
    • 제4권4호
    • /
    • pp.236-240
    • /
    • 1999
  • The characteristics of natural lactic acid fermentation of radish juice were investigated at different salt concentrations (0~2%) and temperatures (10~3$0^{\circ}C$). Major lactic acid bacteria isolated from the radish juice fermented at 2% slat concentration were Leuconostoc mesenteroides, Lactobacillus plantarum, and Lactobacillus brevis. The percentage of lactic acid bacteria against total microbe in the fermented radish juice was over 80% at 0~1% salt concentrations, suggesting the possibility of fermentation even at low salt concentration, but was still active even at 1$0^{\circ}C$. The time to reach pH 4.0 during fermentation of juice of 1% salt concentration was 281~301 hrs at 1$0^{\circ}C$ and 50-73 hrs at 3$0^{\circ}C$. The concentrations of sucrose and glucose in the fermented juice were low at high temperatures and were the lowest at a 1.0% salt concentration. However, the content of mannitol showed the opposite trend. Although sour taste, ripened taste, and acidic odor of the fermented juice showed no significant differences among various temperatures and salt concentrations, sensory values of ripened taste and sour acidic were high at high temperatures. The overall quality was the best at 1.0% salt concentration, irrespective of the temperature.

  • PDF

Low Calorific Gasturbine 매립지 적용 및 유리온실 운용기술 설계 (Design for Landfill Gas Application by Low Calorific Gas Turbine and Green House Optimization Technology)

  • 허광범;박정극;이정빈;임상규
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 춘계학술대회 초록집
    • /
    • pp.244.1-244.1
    • /
    • 2010
  • Bio energy development by using Low Calorific Gas Turbine(LCGT) has been developed for New & Renewable energy source for next generation power system, low fuel and operating cost method by using the renewable energy source in landfill gas (LFG), Food Waste, water waste and Livestock biogas. Low calorific fuel purification by pretreatment system and carbon dioxide fixation by green house system are very important design target for evaluate optimum applications for bio energy. Main problems and accidents of Low Calorific Gas Turbine system was derived from bio fuel condition such as hydro sulfide concentration, siloxane level, moisture concentration and so on. Even if the quality of the bio fuel is not better than natural gas, LCGT system has the various fuel range and environmental friendly power system. The mechanical characterisitics of LCGT system is a high total efficiency (>70%), wide range of output power (30kW - 30MW class) and very clean emmission from power system (low NOx). Also, we can use co-generation system. A green house designed for four different carbon dioxide concentration from ambient air to 2000 ppm by utilizing the exhaust gas and hot water from LCGT system. We look forward to contribute the policy for Renewable Portfolio Standards(RPS) by using LCGT power system.

  • PDF

온도 및 유량에 따른 흡입 마취제 전용 기화기와 Goldman 기화기의 isoflurane 농도 변화 (The Isoflurane Concentration of Precision Vaporizer Goldman Vaporizer According to Room Temperature and Carrier Gas Flow Rate)

  • 김성미;장화석;이정선;최치봉;임희란;최준철;김휘율
    • 한국임상수의학회지
    • /
    • 제21권3호
    • /
    • pp.270-275
    • /
    • 2004
  • Anesthetic machines may be equipped with either a precision or nonprecision vaporizer. A precision vaporizer is designed to deliver an exact concentration of anesthetic agent. Goldman vaporizer is a low-flow, closed-circle circuit with a low resistance vaporizer, in circuit. Vaporizers used within circle system(VIC) are not usually temperature compensated and this is generally thought to be a disadvantage. As the volatile agent is vaporized, heat is extracted from the liquid and temperature decreases. This cooling of the liquid leads to a decrease in concentration of the anaesthetic agent delivered by the vaporizer. The purpose of this study is to examine the mechanical consistency of the delivery of isoflurane from Goldman vaporizer and precision vaporizer at various gas flow rates and temperatures. And we first studied isoflurane concentration according to room temperature changes delivered by a Goldman vaporizer and precision vaporizer using different gas flow. The room temperature of $15^{\circ}C,$ $20^{\circ}C,$ $28^{\circ}C$ and fresh gas flow rates of 0.5, 1.0, 1.5, 2.0, 3.0 l/min were used. The inspired agent concentration was measured using a Datex-Ohmeda multigas analyzer. As rose in room temperature, the isoflurane concentration of precision vaporizer approximated the dial setting. On the other hand, at a dial setting concentration of 5.0 percent the delivered isoflurane concentration of precision vaporizer was more than the dial setting in high temperature. The isoflurane concentration of precision vaporizer remained constant despite the increase in temperature. The isoflurane concentration of Goldman vaporizer was increased with rise in room temperature and decreased with rise in gas flow.

반응성 산소족이 사람 정자의 운동성에 미치는 영향 (Effects of Reactive Oxygen Species on Motility in Human Spermatozoa)

  • 강희규;김동훈;한성원;김묘경;권혁찬;이호준;김문규
    • Clinical and Experimental Reproductive Medicine
    • /
    • 제27권4호
    • /
    • pp.393-403
    • /
    • 2000
  • Objective: To investigate the effects of ROS on kinematic parameters in human spermatozoa. To verify the changes in above parameters, human spermatozoa were incubated with xanthine-xanthine oxidase (X-XO), $H_2O_2$, sodium nitroprusside (SNP) or lymphocyte. Otherwise, spemlatozoa were incubated under low $O_2 (5%) condition. Methods: CASA was employed to analyze sperm motion parameters. Results: Under $H_2O_2 treatment, all kinematic parameters of spermatozoa were dramatically increased during 30 min, but gradually decreased thereafter. Under the low concentration of $H_2O_2 (125 ${\mu}M$ and 250 ${\mu}M$), the movement velocity (VAP, VCL, VSL) decreased, but forward movement increased. Under the 1mM $H_2O_2, sperm showed reduced kinematic parameters except during first 30 min of incubation. In the cases of X-XO and SNP treatment, the movement velocity increased but the forward movement reduced. After incubation for 3 hr treatment, the kinematic parameters gradually decreased in high concentration of X-XO. However these parameters maintained or increased in low concentration of X-XO. There was no obvious changes in the above parameters in the high concentration of SNP. In the presence of high concentration of lymphocytes, all parameters decreased. Under the 5% $O_2 condition, the parameters of the movement velocity and movement pattern increased, but forward movement decreased. Taken togethers, it suggested that ROS increased the movement velocity but decreased the forward movement and lateral head replacement. $H_2O_2, X-XO, SNP and lymphocyte treatment significantly increased capacitated spermatozoa within I h of incubation. There was no significant difference in capacitation between low- and high $O_2 group. Conclusion: The early onset of capacitation in the presence of ROS suggest that ROS might be a positive regulator of sperm capacitation and hyperactivation. These results demonstrate that low concentration ROS facilitates the movement velocity but high concentration ROS was inhibitory.

  • PDF

한국재래산양육(韓國在來山羊肉)의 근원섬유(筋原纖維) 단백질(蛋白質)에 관(關)한 연구(硏究) (Studies on the Myofibrillar Proteins from Korean Native Goat)

  • 홍종용;문윤희;고진복
    • Journal of Nutrition and Health
    • /
    • 제11권3호
    • /
    • pp.37-42
    • /
    • 1978
  • Actomyosin and myofibril were extracted from Korean native Goat muscle with the Weber-Edsall solution. ATPase activities and physiochemical properties were measured. The results obtained were as follows; 1) Mg-activitied ATPase activity of actomyosin and myofibrill from Korean native Goat muscle exhibited a common biphasic response, a typical ATPase pattern, that is high at a low ionic strength and low at a high ionic strength. Actomyosin showed high activity than myofibrill. 2) Mg-activited ATPase activity of actomyosin from muscle increased extraction time 24 hours. 3) EDTA-enhanced ATPase activity of actomyosin was greater than myofibrill and low at the low ionic strength, high at the high ionic strength. The difference of the activity were shown great broad pattern at the after 0.3M KCI concentration. 4) Effect of EGTA on-ATPase activity of myofibrill and actomyosin from muscle was measured, the Mg-ATPase activity was markedly depressed. 5) Solubility of actomyosin from muscle began to solubilize at KCI concentration of 0.28M and solubilized completely at the KCI concentration of 0.3M.

  • PDF

Design Optimization of an Ozone Contactor Using Ozone Contactor Model (OCM) Software

  • Kim, Doo-Il;Lee, Chae-Young;Joe, Woo-Hyeun;Lee, Seock-Heon
    • Environmental Engineering Research
    • /
    • 제14권4호
    • /
    • pp.244-249
    • /
    • 2009
  • Designing an ozone contactor is complicated because the residual ozone, log C. parvum inactivation, and bromate formation should be optimized with fluctuating water quality. OCM software was developed to assist a plant designer or an operator to fulfill the sophisticated optimization required in the design or operation of a new or an existing plant. In this article, numerical simulations were carried out using the OCM software for the design of a new ozone contactor under diverse design factors (i.e., three pHs, three temperatures, low and high dispersion numbers, and four and ten cells with complete mixing) with kinetic parameters obtained from the sand-filter effluent of a water treatment plant treating water from the Paldang impoundment. The results of the simulation suggested that a high residual ozone concentration at low pH and low temperature would be challenging, and PFR-like hydrodynamics could lower the residual ozone concentration. The inactivation of C. parvum oocysts increased at a lower pH. A lower dispersion number and more cell division increased the inactivation efficiency. Bromate was instantaneously formed during the initial ozonation stage. The effluent concentration was much lower than the regulatory levels imposed by the USEPA because of the low bromide level in raw water.

저온열원 활용을 위한 암모니아-물 재생 랭킨사이클의 엑서지 해석 (Exergy Analysis of Regenerative Ammonia-Water Rankine Cycle for Use of Low-Temperature Heat Source)

  • 김경훈;고형종;김세웅
    • 한국수소및신에너지학회논문집
    • /
    • 제23권1호
    • /
    • pp.65-72
    • /
    • 2012
  • Rankine cycle using ammonia-water mixture as a working fluid has attracted much attention, since it may be a very useful device to extract power from low-temperature heat source. In this work, the thermodynamic performance of regenerative ammonia-water Rankine cycle is thoroughly investigated based on the second law of thermodynamics and exergy analysis, when the energy source is low-temperature heat source in the form of sensible energy. In analyzing the power cycle, several key system parameters such as ammonia mass concentration in the mixture and turbine inlet pressure are studied to examine their effects on the system performance including exergy destructions or anergies of system components, efficiencies based on the first and second laws of thermodynamics. The results show that as the ammonia concentration increases, exergy exhaust increases but exergy destruction at the heat exchanger increases. The second-law efficiency has an optimum value with respect to the ammonia concentration.

저가형 냉각탑 자동 수질 진단 시스템 개발 (Development of a Low-cost Automatic Water Quality Diagnosis System for Cooling Towers)

  • 김정환;박한빈;강태삼;박정근
    • 센서학회지
    • /
    • 제23권1호
    • /
    • pp.58-65
    • /
    • 2014
  • We developed a low-cost automatic diagnosis system for water quality in cooling towers to measure the concentrations of key ingredients such as $Ca^{2+}$, $Cl^-$, $PO{_4}^{3-}$, and $Fe^{2+}$. $Ca^{2+}$, and $Cl^-$ are the main factors that cause the generation of scale, corrosion, and sludge in water pipes. $PO{_4}^{3-}$ prevents corrosion, sludge and scale by inhibiting the ions (i.e., $Ca^{2+}$, $Cl^-$) from sticking to the pipes. $Fe^{2+}$ is an indicator of pipe corrosion. The proposed system consists of a microprocessor, a specimen container and heater, a precision pump, relays and valves, LED optical sources, and photo detectors. It automatically collects water samples and carries out pretreatment for determining the concentration of each chemical, and then estimates the concentration of each ion using low-cost LED optical sources and detectors. Experimental results showed that the accuracy of the proposed system is sufficiently high for water quality diagnosis and management of cooling towers, demonstrating the possibility of the proposed system's wide usage in real environments.

인이 주입된 poly-Si/SiO$_{2}$/Si 기판에서 텅스텐 실리사이드의 형성에 관한연구 (Stduy on formation of W-silicide in the diped-phosphorus poly-Si/SiO$_{2}$/Si-substrate)

  • 정회환;주병권;오명환;정관수
    • 전자공학회논문지A
    • /
    • 제33A권3호
    • /
    • pp.126-134
    • /
    • 1996
  • Tungsten silicide films were deposited on the phosphorus-doped poly-Si/SiO$_{2}$/Si-substrates by LPCVD (low pressue chemical vapor deposition). The formation and various properties of tungsten silicide processed by furnace annealing in N$_{2}$ ambient were evaluated by using XRD. AFM, 4-point probe and SEM. And the redistribution of phosphorus atoms has been observed by SIMS. The crystal structure of the as-deposited tungsten silicide films were transformed from the hexagonal to the tetragonal structure upon annealing at 550.deg. C. The surface roughness of tungsten polycide films were found to very smoothly upon annelaing at 850.deg. C and low phosphorus concentration in polysilicon layer. The sheet resistance of tungsten polycide low phosphorus concentration in polysilicon layer. The sheet resistance of tungsten polycide films are measured to be 2.4 .ohm./ㅁafter furnace annealing at 1100.deg. C, 30min. It was found that the sheet resistance of tungsten polycide films upon annealing above 1050.deg. C were independant on the phosphorus concentration of polysilicon layer and furnace annealing times. An out-diffusion of phosphorus impurity through tungsten silicide film after annealing in $O_{2}$ ambient revealed a remarkably low content of dopant by oxide capping.

  • PDF

Serratia marcescens Purine Nucleoside Phosphorylase의 생합성에 대한 글리옥실산의 대사적 역할 (Metabolic Role of Glyoxylate on the Biosynthesis of Serratia marcescens Purine Nucleoside Phosphorylase)

  • 방선권
    • 한국식품영양학회지
    • /
    • 제12권1호
    • /
    • pp.43-49
    • /
    • 1999
  • The effects of purine catabolites in growth media on the Serratia marcescens purine nucleoside phos-phorylase activity were examined. The enzyme activity was decreased above 60% by guanosine(5 to 15mM). The enzyme activity was not affected at low concentration of inosine (0.1∼1mM). The en-zyme activity was decreased approximately by 40∼50% in the presence of high concentrations of aden-osine hypoxanthine and xanthine (5∼15mM) but was not affected at low concentration of adenosine hypoxanthine and xanthine (0.1∼0.5mM). However the enzyme activity was increase by 20% with low concentrations of uric acid(0.5mN). but was decreased by 80% with high concentrations of same purine catabolite (15mM). Also the enxzyme activity was increased by 20% with low concentrations of glyoxylate (0.5mM) final degradative product of uric acid but was decreased by 30∼50% with high con-centrations of glyoxylate (3∼15mM). The enzyme activity was decreased approximately by 20% by the simultaneous addition of inosine hypoxanthine and uricacid at 5mM each whereas it was increased by 22 and 33% by the combination of inosine and uric acid three purine catabolites at 0.5mM respectively These data suggest that S. marcescens purine nucleoside phosphorylase is positively regulated by a glyox-ylate concentration and then may play a regulatory role in a purine catabolism.

  • PDF