• Title/Summary/Keyword: Low bypass

Search Result 285, Processing Time 0.032 seconds

Clinical study on Renal Replacement Therapy for Acute Renal Failure following Cardiopulmonary Bypass (체외순환후 급성 심부전에 대한 신대체요법의 임삼적 검토)

  • 서경필
    • Journal of Chest Surgery
    • /
    • v.25 no.3
    • /
    • pp.232-239
    • /
    • 1992
  • Acute renal failure is a well known serious complication following open heart surgery and is associated with a significant increase in morbidity and mortality rate. From 1984 to 1990, 33 patients who had acute renal failure following cardiopulmonary bypass received renal replacement therapy. PD[Peritonial dialysis] was employed in 11 patients and CAVH[continous arteriovenous hemofiltration] was employed in 22 patients. Their age ranged from 3 months to 64 years[mean 25.5$\pm$7.8 years]. The disease entities included congenital cardiac anomaly in 18, valvular heart disease in 15 and aorta disease in 2 cases. Low cardiac output was thought as a primary cause of ARF except two redo valve cases who showed severe Aemolysis k depressed renal function preoperatively. Mean serum BUN and creatinine level at the onset renal replacement therapy were 65$\pm$8 mg/dl and 3.5$\pm$0.4 mg/dl respectively, declining only after reaching peak level 7&10 days following the onset of therapy. Overall hospital mortality was 72.7%[24/33]; 81%[9/11] in PD group and 68.2% [15/22] in CAVH group respectively. The primary cause of death was low cardiac output & hemodynamic depression in all the cases. The fatal complications included multiorgan failure in 7, disseminated intravascular coagulation and sepsis in 6, neurologic damage in 4 and mediastinitis in 3 cases. No measurable differences were observed between CAVH and PD group upon consequence of acute renal failure and disease per se. The age at operation, BUN/Cr level at the onset of bypass and highest BUN/Cr level and the consequence of low output status were regarded as important risk factors, determining outcome of ARF and success of renal replacement therapy. Thus, we concluded that althoght the prognosis is largely determined by severity of low cardiac output status and other organ complication, early institution of renal replacement therapy with other intensive supportive measures could improve salvage rate in established ARF patients following CPB.

  • PDF

A Highly Efficient Dual-Mode 3G/4G Linear CMOS Stacked-FET Power Amplifier Using Active-Bypass

  • Kim, Unha;Kim, Yong-Gwan;Woo, Jung-Lin;Park, Sunghwan;Kwon, Youngwoo
    • Journal of electromagnetic engineering and science
    • /
    • v.14 no.4
    • /
    • pp.393-398
    • /
    • 2014
  • A highly efficient dual-mode linear CMOS stacked-FET power amplifier (PA) is implemented for 3G UMTS and 4G LTE handset applications. High efficiency is achieved at a backed-off output power ($P_{out}$) below 12 dBm by employing an active-bypass amplifier, which consumes very low quiescent current and has high load-impedance. The output paths between high- and low-power modes of the PA are effectively isolated by using a bypass switch, thus no RF performance degradation occurs at high-power mode operation. The fabricated 900 MHz CMOS PA using a silicon-on-insulator (SOI) CMOS process operates with an idle current of 5.5 mA and shows power-added efficiency (PAE) of 20.5%/43.5% at $P_{out}$ = 12.4 / 28.2 dBm while maintaining an adjacent channel leakage ratio (ACLR) better than -39 dBc, using the 3GPP uplink W-CDMA signal. The PA also exhibits PAE of 35.1% and $ACLR_{E-UTRA}$ of -33 dBc at $P_{out}$ = 26.5 dBm, using the 20 MHz bandwidth 16-QAM LTE signal.

Aortic Valve Replacement and Concomitant Multi-Vessel Coronary Artery Bypass: The Impact of Using the Bilateral Internal Thoracic Arteries on Early and Late Clinical Outcomes

  • Muhyung Heo;Myoung Young Kim;Jun Ho Lee;Suryeun Chung;Kiick Sung;Wook Sung Kim;Yang Hyun Cho
    • Journal of Chest Surgery
    • /
    • v.56 no.3
    • /
    • pp.197-203
    • /
    • 2023
  • Background: The survival benefit of coronary artery bypass grafting (CABG) using the bilateral internal thoracic arteries (BITA) is well known; however, the role of BITA in concomitant aortic valve replacement (AVR) and CABG has not been studied. Methods: We retrospectively reviewed patients who underwent concomitant AVR and CABG. Cases not using an internal thoracic artery and less than 2 bypass grafts were excluded. We enrolled 114 patients in this study. The mean follow-up duration was 61.5±43.5 months. Results: Forty patients (35.1%) underwent CABG with a single internal thoracic artery (SITA) and 74 patients (64.9%) underwent CABG with BITA. The preoperative clinical characteristics were not significantly different between the 2 groups, with the exception of a higher prevalence of atrial fibrillation in the SITA group. Postoperative mortality and morbidity were not significantly higher in the BITA group than in the SITA group. In the univariable analysis, the survival of the BITA group was similar to that of the SITA group (p=0.157). Multivariable analysis showed that only mean age was a predictor of death (p=0.042), but using BITA was not an independent predictor (p=0.094). In low-risk patients whose preoperative ejection fraction was >45%, the survival of the BITA group was significantly better than that of the SITA group (p=0.043). Conclusion: BITA use in concomitant AVR and CABG showed no difference in mortality compared to using SITA. Although its impact on long-term survival was inconclusive, BITA use can be considered for low-risk patients.

Design and Implementation of Frequency Down Converter for Satellite Communication (위성 통신용 주파수 하향 변환기의 설계 및 제작)

  • Lee, Seung-Dae;Na, Sang-Yeob
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.2
    • /
    • pp.801-807
    • /
    • 2012
  • In this paper, design and implementation of frequency down converter based on LC filter technic. Single frequency down converter, designed a low-noise amplifier, mixer, IF amplifier, LC filter was configured. And it is composed of DC block capacitors and RF bypass capacitor. LC filter, replace it with the IC reduced the power and realized low cost. The gain of single down converter is about 10dBm and realized by 18MHz bandwidth at 70MHz band.

The Effects of the Orifice Shapes on the Internal Visualization and The Spray Characteristics of the Single Hole Nozzle (오리피스 형상에 따른 단공 노즐의 내부 가시화와 분무 특성)

  • Son, Jong-Won;Cha, Keun-Jong;Kim, Duck-Jool
    • Journal of ILASS-Korea
    • /
    • v.7 no.1
    • /
    • pp.36-42
    • /
    • 2002
  • The objective of this investigation was to obtain an excellent spray at the low injection pressure. When cavitation occurred in the nozzle hole the atomization of the liquid jet enhanced considerably. In this experiments, a acrylic nozzle which was installed the gap and installed the bypass in the nozzle hole was used to enhance the atomization of the liquid jet at the few injection pressure. The liquid flow in the nozzle hole was photographed by a transmitted light using a micro flash. The spray angle was measured by macroscope images of PMAS and the Sauter mean diameter was measured by PDA system. The pressure of the notate hole was measured by pressure transducer. It was found that enhanced atomization of the liquid jet at the low injection pressure was obtained by installing the gap and the bypass at the single hole nozzle.

  • PDF

Clinical Comparison of Low-dose and High-dose Steroid in Pediatric Cardiac Surgery with Cardiopulmonary Bypass

  • Choi Seok-Cheol;Kim Song-Myung;Kim Yang-Weon
    • Biomedical Science Letters
    • /
    • v.12 no.3
    • /
    • pp.289-301
    • /
    • 2006
  • Cardiopulmonary bypass (CPB) for cardiac surgery triggers the production and release of numerous chemotactic substances and cytokines, ensuing systemic inflammatory response that leads to postoperative major organ dysfunction. Traditionally, corticosteroids (steroid) have been administered to patients undergoing cardiac surgery to ward off these detrimental physiologic alterations. However, the majority of the studies have been performed on adult patients with high-dose steroid. We carried out a randomized, prospective, double-blind study to compare the efficacy of low-dose steroid with that of high-dose steroid and to determine the adequate dose of pretreated-steroid for prophylactic effects in pediatric cardiac surgery. Thirty pediatric patients scheduled for elective cardiac surgery were randomly assigned to two groups; fifteen patients received low-dose methylprednisolone (10mg/kg intravenously, n=15, low-dose group) and the others received high-dose methylprednisolone (30mg/kg intravenously, n=15, high-dose group) 1 hour prior to CPB. Arterial blood samples were taken before CPB (Pre-CPB), 10 minutes after start of CPB (CPB-10), and immediately after CPB-end (CPB-OFF) for measuring total leukocyte counts (T-WBC) and diff-counts, platelet counts, interleukin-6 (IL-6), myeloperoxidase (MPO), total antioxidant (TAO), neuron-specific enolase (NSE), troponin I (TNI), aspartate aminotransferase (AST), alanine aminotransferase (ALT), creatinine, and blood urea nitrogen (BUN) levels. Other parameters such as volumes of urine output, pulmonary index $(PI,\;PaO_2/FiO_2)$, mechanical ventilating period, intensive care unit (ICU)-staying period, postoperative complications (fever, wound problem), postoperative 24 hrs and total volumes in blood loss, and hospitalized days were also assessed. All parameters were compared between two groups. There were no significant differences in T-WBC counts, monocyte fraction, platelet counts, TA levels, NSE levels, creatinine levels, BUN levels, the volumes of total urine output, PI, the incidences of fever and wound problem, postoperative 24hrs- and total-blood loss volumes and ICU-staying period between two groups (P>0.05). At CPB-OFF, neutrophil fraction, MPO level, TNI level, and AST level were higher in the high-dose group than in the low-dose group (P<0.05). IL-6 level at CPB-10 was higher in the high dose-group than in the low-dose group (P<0.05). Furthermore, mechanical ventilating periods and hospitalized days of the high-dose group were significantly longer than those of low-dose group (P<0.05). The high-dose group had significantly low lymphocyte fi-action at CPB-OFF compared with the low-dose group (P<0.001). These findings suggest that pretreatment of high-dose steroid is not superior to that of low-dose steroid regrading its potential benefits in pediatric cardiac surgery. Therefore, the conventional strategy of steroid treatment, high-dose pretreatment, should be modified in the cardiac surgery with CPB. However, further studies must be performed on the larger number of patients in as much as small number of patients in this study.

  • PDF

Subxiphoid Incisional Hernia Development after Coronary Artery Bypass Grafting

  • Kim, Hye-Seon;Kim, Ki-Bong;Hwang, Ho-Young;Chang, Hyung-Woo;Park, Kyu-Joo
    • Journal of Chest Surgery
    • /
    • v.45 no.3
    • /
    • pp.161-165
    • /
    • 2012
  • Background: Median sternotomy can weaken the upper abdominal wall and result in subxiphoid incisional hernia. We evaluated risk factors associated with the development of subxiphoid incisional hernias after coronary artery bypass grafting (CABG). Materials and Methods: Of 1,656 isolated CABGs performed between January 2001 and July 2010, 1,599 patients who were completely followed up were analyzed. The mean follow-up duration was $49.5{\pm}34.3$ months. Subxiphoid incisional hernia requiring surgical repair developed in 13 patients (0.8%). The hernia was diagnosed $16.3{\pm}10.3$ months postoperatively, and hernia repair was performed $25.0{\pm}26.1$ months after the initial operation. Risk factors associated with the development of subxiphoid incisional hernia were analyzed with the Cox proportional hazard model. Results: Five-year freedom from the hernia was 99.0%. Univariate analysis revealed that female sex (p=0.019), height (p=0.019), body surface area (p=0.046), redo operation (p=0.012), off-pump CABG (p=0.049), a postoperative wound problem (p=0.041), postoperative bleeding (p=0.046), and low cardiac output syndrome (p<0.001) were risk factors for the development of the hernia. Multivariable analysis showed that female sex (p=0.01) and low cardiac output syndrome (p<0.001) were associated with subxiphoid hernia formation. Conclusion: Female sex and postoperative low cardiac output syndrome were risk factors of subxiphoid hernia. Therefore, special attention is needed for patients with high-risk factors.

Low-Dose Aprotinin Effect on Hemostasis After Cardiopulmonary Bypass (체외 순환후 지혈에 대한 저농도의 Aprotinin 효과)

  • Lee, Seon-Hui;Choe, Seung-Ho;Gwak, Mun-Seop
    • Journal of Chest Surgery
    • /
    • v.29 no.2
    • /
    • pp.185-190
    • /
    • 1996
  • The effect of low-dose aprotinin on hemostasis in patients undergoing cardiopulmonary bypass (CPB) for repeat valve replacement and coronary artery bypass operations were investigated. Thirty patients undergoing elective CPB from February 1993 through February 1995 at Catholic Medical Center were studied. the patients were randomly divided into two groups(15 patients per group) : group 1, receive 1, 000, 000 KIU/kg aprotinin in the CPB priming volume and 20, 000 KIU/kg aprotinin intravenously each hour during CPB ; group 2, without aprotinin administration served as the controls. The result showed that the early postoperative (during the first 24 hours) and mean postoperative total blood loss of the aprotinin group were significantly reduced than the control group (317.2 $\pm$ 89.6ml in the aprotinin group versus 821.3 $\pm$ 441.2rnl in the control group, p<0.01 ; 767.2 $\pm$ 214.1 ml in the aprotinin group versus 1562.5 $\pm$ 735.2 rnl in the control gorup, p<0.01). Total use of packed red ells and fresh frozen plasma was higher in control group(1.22 $\pm$ 0.3 units versus 4.21 $\pm$ 1.7units of packed red cells, p<0.01 : and 2.37 $\pm$ 0.4units versus 6.72 $\pm$ 0.88uni1s of fresh prozen plasma, p<0.05). We conclude the low-dose aprotinin was positive influence on postoperative blood loss in undergoing highly bleeding potency cardiac operation.

  • PDF

Differential Signature of Obesity in the Relationship with Acute Kidney Injury and Mortality after Coronary Artery Bypass Grafting

  • Moon, Hongran;Lee, Yeonhee;Kim, Sejoong;Kim, Dong Ki;Chin, Ho Jun;Joo, Kwon Wook;Kim, Yon Su;Na, Ki Young;Han, Seung Seok
    • Journal of Korean Medical Science
    • /
    • v.33 no.48
    • /
    • pp.312.1-312.10
    • /
    • 2018
  • Background: Obesity is related to several comorbidities and mortality, but its relationship with acute kidney injury (AKI) and long-term mortality remain undetermined in patients undergoing coronary artery bypass grafting. Methods: Data from 3,018 patients (age ${\geq}18$ years) who underwent coronary artery bypass graft surgery from two tertiary referral centers were retrospectively reviewed between 2004 and 2015. Obesity was defined using the body mass index, according to the World Health Organization's recommendation. The odds and hazard ratios in post-surgical, AKI, and all-cause mortality were calculated after adjustment for multiple covariates. Patients were followed for $90{\pm}40.9$ months (maximum: 13 years). Results: Among the cohort, 37.4%, 2.4%, 21.1%, 35.1%, and 4.0% of patients were classified as normal weight, underweight, overweight-at-risk, obese I, and obese II, respectively. Post-surgical AKI developed in 799 patients (26.5%). Patients in the obese groups (overweight-at-risk to obese II) had a higher risk of AKI than did those in the normal-weight group. During the follow-up period, 787 patients (26.1%) died. Underweight patients had a higher risk of mortality than did normal-weight patients, whereas overweight-at-risk, obese I, and obese II patients showed better survival rates. Conclusion: After coronary artery bypass graft surgery, obese patients encountered a high risk of AKI, and underweight patients exhibited a low chance of survival. Awareness of both obese and underweight statuses should be raised in these patients.

Design and Implementation of Double Down-Converter for Satellite TV (위성 TV용 이중 하향 변환기의 설계 및 제작)

  • Lee, Seung-Dae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.2
    • /
    • pp.840-845
    • /
    • 2013
  • In this paper, the broadband frequency double down-converter based on LC filter technologies has been designed and implemented, and its performances are introduced. The Designed frequency double down-converter is consisted with a low-noise amplifier, mixer, IF amplifier, LC filter, DC-block capacitor and RF-bypass capacitor. Especially, instead of active devices of a typical converter, the suggested converter designed using passive devices to provide both low-power consumption and low-cost model. As results of the measurement, the implemented frequency double down-converter realizes the broadband performance with the bandwidth of 100MHz (13~113MHz) at the center frequency of 63MHz, and its gain is approximately 40dB.