• 제목/요약/키워드: Low Voltage Electrical Installation

검색결과 291건 처리시간 0.017초

국제 표준에 따른 저압간선 전압강하 계산시 적용 방법 고찰 (Application Method Analysis at Voltage Drop Calculations on Low Voltage Feeder by IEC Standard)

  • 김기현;이주철;최영규;김한수;이영철
    • 조명전기설비학회논문지
    • /
    • 제26권6호
    • /
    • pp.53-58
    • /
    • 2012
  • A conductor has been produced according to IEC standard and low voltage electrical facility has been installed according to IEC 60364. But because of many related and varied standards, it is difficult to apply to design and inspect for electrical equipment. We researched the necessity of design guide which is detailed and systematization from survey. For detailed design guide, we suggest application method and review items at calculations for voltage drop calculations on low voltage feeder by IEC 60364, BS 7671 standard and Consumer's Electrical Installation Guide.

저압 전기설비의 과전압 억제 필요성 판단 (Judgement of the need for Over-Voltage Control of the Low-Voltage Electrical Installations)

  • 이주철;김재철
    • 조명전기설비학회논문지
    • /
    • 제29권2호
    • /
    • pp.91-96
    • /
    • 2015
  • There are provision for risk analysis in IEC standards. It is to determine the need for installation of a surge protection device (SPD) in order to protect the low-voltage electrical installations from overvoltages caused by atmospheric phenomena and the like. However, scattered many related standards, the lack of details are not easy to apply it in the field. We investigated the relevant domestic and international standards for applies to the international standards in domestic. And we proposed the flow chart for determining the need for protection of the low-voltage electrical installations from overvoltage due to atmospheric phenomena and it set the appling target facility.

IEC 60364 기반의 한국형 저압전기설비 통합 실증단지 모델링 및 차단기와 케이블의 선정 방안 고찰 (Study of Selection Plan of Circuit breakers, Cables and Modeling of Korean Low Voltage Electrical Installation integration Test Site based on IEC 60364)

  • 김두웅;류규상;김한수;신대성;류기환;김철환
    • 조명전기설비학회논문지
    • /
    • 제29권9호
    • /
    • pp.59-64
    • /
    • 2015
  • IEC is an international standards which are used in many countries with Europe as the center. IEC standard is introduced in Korea according to WTO/TBT agreements, however until now there are no buildings in Korea which are designed applying IEC standard. Therefore, KEA(Korea Electric Association) is scheduled to construct Korean low voltage electrical installation integration test site which is designed applying IEC standard. In this paper, before being under construction of Korean low voltage electrical installation integration test site, power substation is modeled based on real design parameters and method to select circuit breakers and cables is presented applying IEC standard in the modeled power substation. EMTP(ElctroMagnetic Transient Program) is used for simulation program. EMTP which is power system analysis program is easy to model power system and power substation.

침수조건에 따른 저압 지중함의 감전 위험성 평가 (The Assesment of Electric Shock Rate of Low Voltage Joint-Box Based Submerged Condition)

  • 심건보;김경철;김한상;김종민
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2007년도 춘계학술대회 논문집
    • /
    • pp.265-270
    • /
    • 2007
  • The potential and step voltage distribution around low voltage joint-box cover were simulated with the variation of resistivity of water, depth of submerged water and point of leakage current. The potential distribution is very high gradient around low voltage joint-box, this condition is very dangerous states.

  • PDF

온도특성을 고려한 저압간선의 경제적인 설계기법에 관한 연구 (A Study on the Economical Design of Low-Voltae feeder Considering the temperature character)

  • 최홍규;조계술
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2002년도 학술대회논문집
    • /
    • pp.349-354
    • /
    • 2002
  • A size of low-voltage conductor cables is determined by the voltage drop of a system, the cable impedance and the cable ampacity based on temperature correction factor in accordance with the condition of cable installation. Therefore, the proper temperature correction factor according to the condition of cable installation should be applied to determining the cable ampacity and also the skin effect and proximity effect, along with the kind and size of conductor and the condition of cable installation, should be properly considered to analyze the proper value of resistance and the reactance of the conductors. This paper addresses the systematic design flow for determining the size of low voltage level conductor cables in calculating the temperature character where error should be minimized in comparison with the general formula and which can be applied in design work for determining the size of conductor cables.

  • PDF

디지털 신호 처리 기반 저압 차단기용 전자식 계전기 개발 (A Development of Electronic Type Relay for Low Voltage Circuit Breaker based on Digital Signal Processing)

  • 박병철;손종만;송성근;신중린
    • 조명전기설비학회논문지
    • /
    • 제27권5호
    • /
    • pp.81-88
    • /
    • 2013
  • A low voltage circuit breaker protects electrical equipments from over current and short faults of system by cutting the power supply. The breaker use a thermal magnetic type trip device from the past. In recent years, electronic type relays are applied due to useful functions and services. The purpose of this development is full digitalizing of relay functions of a low voltage breaker. It includes separation of current sensor from current transformer, digital signal processing, high speed relaying, and voltage measuring for power meter. The suggestions are tested and implemented by making prototype and testing its all relay functions.

신재생에너지용 연계형 인버터의 고효율 승압에 관한 연구 (Study on High Efficiency Boosting-up Circuit for Renewable Energy Application)

  • 정태욱;김주용;최세권;조준석;고희석
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2009년도 춘계학술대회 논문집
    • /
    • pp.336-339
    • /
    • 2009
  • In this paper, such as battery power or solar energy and fuel cells generated from Renewable energy sources, high voltage to low voltage DC-DC Converter for converting the design of the study. System consists of low voltage ($24{\sim}28$ [VDC]) and Boosts the voltage (270 [VDC]) for a 3 [kW] DC-DC converter and control circuit is configured as, Power switch the ST Tomson's Automotive low voltage high current MOSFET switches STE250NS10S (temperature 250A) was applied to the two parallel. Also, Controller's processor used ATMEGA128, and Gate Drive applies and composed Photo Coupler TLP250. development. Input voltage (24V) and output voltage (270V) for Conversion in the H-bridge converter topology of the circuit output side power and voltage to control the implementation of the Phase shift angle control applied. And, 3kW of power to pass appropriate specification of the secondary side as interpreted by the high frequency transformer, and the experimental production and analysis of the experiment

  • PDF

저압 전원계통에서 고조파 양상의 분석에 관한 연구 (A Study on the Analysis of Harmonics Aspects on Low-voltage AC Mains)

  • 이복희;백영환
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 춘계학술대회 논문집
    • /
    • pp.100-103
    • /
    • 2004
  • This paper presents the aspect and distribution of voltage and current harmonics being made at low voltage power systems. The voltage and current harmonics in power systems supplying various loads were monitored and analyzed. We have examined the results compared to advanced countries' harmonics control standards. As a result, the current harmonics were significantly greater than the voltage harmonics. In particular, the harmonics of currents flowing through loads with power switching electronics was pronounced. Also, the contents of current harmonics of street lamp circuits was about 30%, and it was decreased to 12.3% with the installation of series reactor. On the whole, The measured results of voltage and current harmonics exceeds the regulation limits recommended by IEEE 519-1992.

  • PDF

태양광 발전소의 전기설비 설계 및 저압 계통연계 적용사례에 관한 연구 (A Study on electric facilities plan and application of low-voltage grid connection for a photovoltaic electric power station)

  • 임경미;김경화
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2009년도 춘계학술대회 논문집
    • /
    • pp.305-308
    • /
    • 2009
  • This paper resents a study on the electric facilities plan and application of low-voltage grid connection for a photovoltaic electric power station. The analysis for an installation cost is carried out and a new plan to solve the problem caused by a voltage drop in a low-voltage grid connection is devised. It is expected that the results can be usefully applied to spread the photovoltaic electric power station.

  • PDF

저압분전반에서 접지 경로를 통한 차단기의 트래킹 화재위험성에 관한 연구 (A study on the Fire Hazard for the Tracking of RCD through Ground Path at Low Voltage Cabinet Panel)

  • 김동욱;이기연;김동우;길형준;김향곤;정영식
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 춘계학술대회 논문집
    • /
    • pp.349-352
    • /
    • 2008
  • The electrical accidents result from insulation blackdown due to over voltage and overheating due to the excess of allowable current, deterioration of insulation performance due to the passage of time, and so on. In this paper, the insulating characteristics of phenolic resin using insulating materials for low voltage were analyzed and the tracking test was performed according to IEC Publ. 112.

  • PDF