• Title/Summary/Keyword: Low Temperature Performance

Search Result 2,099, Processing Time 0.035 seconds

Experimental Research Application to each Types of Insulation Materials in Rural Houses (농촌주택의 단열 재료별 현장 적용을 위한 실험 연구)

  • Kwon, Soon-Chan;Kim, Eun-Ja
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.19 no.4
    • /
    • pp.57-65
    • /
    • 2017
  • Life quality in farming areas is declining these days on account of decrease in population with the outflow of young generations, advent of aging society, and also lack of social and physical infrastructure. To reverse this, the central and local governments have been devising policies in many ways; however, the vulnerable class in farming area suffering from financial difficulty is not supported with that properly. The results of applying insulation materials applicable to rural houses, EPS, e-board, and glass wool, actually to rural houses are summed as follows. EPS is the most inexpensive among the three installations in terms of material cost and expenses. The indoor and outdoor temperature difference increased from $0.9^{\circ}C$ to $2.5^{\circ}C$, and the temperature change reduced as $0.04^{\circ}C$. With e-board, the indoor and outdoor temperature difference increased from $3.3^{\circ}C$ to $7.5^{\circ}C$; however, the temperature change increased as $0.09^{\circ}C$. Unlike the other two methods, glass wool requires the additional installation of wooden frames. The material cost is highest, and the indoor and outdoor temperature difference increased from $1.1^{\circ}C$ to $8.0^{\circ}C$, and the temperature change reduced as $0.01^{\circ}C$. According to the results of measuring temperature, glass wool's temperature difference is measured to be the highest, but temperature change is found to be the most effective in EPS. Among the three insulation methods, EPS is the most economically advantageous as the material supply is easy and the cost is low. The material is easily processible, so ordinary town residents can install it easily, and it is effective at improving insulation performance, too. But this method cannot be applied when the house has walls that are not even. Also, as the insulator is thick, after the installation, the living space may be narrower as a result.

Effects of Hot Environment and Dietary Protein Level on Growth Performance and Meat Quality of Broiler Chickens

  • Gu, X.H.;Li, S.S.;Lin, H.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.21 no.11
    • /
    • pp.1616-1623
    • /
    • 2008
  • This study was conducted to determine the effect of hot environment and dietary crude protein level (CP) on performance, carcass characteristics, meat visual quality, muscle chemical composition and malondialdehyde (MDA) concentration of tissues in broilers. Two hundred and sixteen 21-d old Arbor Acre broilers were used in a $4\times3$ factorial arrangement and randomly reared in 4 environmental chambers and fed on 3 diets with different CP levels for 3 weeks. The results showed: (1) when air temperature (AT) rose to $33^{\circ}C$, average daily feed intake, average daily gain, carcass weight, right breast meat weight, left thigh and drumstick meat weight decreased (p<0.05) and feed conversion rate decreased (p<0.05), but the ratio of carcass to live weight and of left thigh and drumstick meat weight to carcass weight increased (p<0.05). (2) There were significant differences in pH and shear force in breast meat, and shear force, L* and a* in thigh meat (p<0.01 or 0.05) among hot environments. Dietary CP level tended to affect breast meat pH and pH and L* of thigh meat (p<0.06 or 0.09). Compared to the normal temperature ($22^{\circ}C$), low temperature ($15^{\circ}C$) and hot humid (AT $33^{\circ}C$, relative humidity (RH) 80%) treatments significantly (p<0.05) decreased the tenderness of thigh meat. L* and a* value in thigh meat under high temperature treatments, regardless of RH, were higher (p<0.05) than those under normal temperature. (3) Protein content in breast and thigh meat of broilers fed under high temperature ($33^{\circ}C$) was lower (p<0.05) than that under $22^{\circ}C$, but fat content had an adverse change. High temperature ($33^{\circ}C$) increased the moisture of breast meat significantly (p<0.05). Protein content in breast meat increased significantly (p<0.05), in which fat content had an adverse change (p<0.05), when the dietary protein rose. (4) MDA concentration in liver and breast meat under hot humid (AT $33^{\circ}C$, RH 80%) treatment increased markedly (p<0.05). (5) High humidity could sharpen the bad effect of high temperature on performance, carcass yield and choice cuts, crude protein and moisture content in breast meat. It was concluded that a hot environment could affect the performance and meat quality of broiler chicks more significantly than CP level and that high humidity would aggravate the bad influence of high temperature on the broiler.

Numerical Analysis of Effects of Water Mist Injection Characteristics on Cooling Performance in Heated Chamber (미분무수 분사 특성에 따른 가열 챔버 내 냉각 성능 수치 해석)

  • Sumon, S.M.;Lee, S.W.
    • Journal of ILASS-Korea
    • /
    • v.17 no.2
    • /
    • pp.64-70
    • /
    • 2012
  • Water mist fire suppression systems which use relatively small droplets of water with high injection pressure are increasingly being used in wider applications because of its greater efficiency, low flooding damage and low toxicity. However, the performance of the system significantly relies on the water mist characteristics and it requires better understanding of fire suppression mechanism of water mist. In the present study, computational fluid dynamics simulations were carried out to investigate cooling performance of water mist in heated chamber. The gas phase was prepared with natural convection heat transfer model for incompressible ideal case and then the effects of water mist injection characteristics on cooling capabilities were investigated upon the basis of the pre-determined temperature field. For the simulation of water mist behavior, Lagrangian discrete phase model was employed by using a commercial code, FLUENT. Smaller droplet sizes, greater injection angles and higher flow rates provided relatively higher cooling performance.

Performance Evaluation of Water Vapour Adsorption & Desorption Properties of Ceramic Panel and Painting Materials for Humidity Control (습도조절용 세라믹패널 및 도료의 흡·방습성능 평가)

  • Jang, Kun-Young;Ryu, Dong-Woo
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.3
    • /
    • pp.43-52
    • /
    • 2018
  • This study is conducted to evaluate the performance of ceramic panels and painting materials for humidity control which are developed in non-plastic room temperature hardening structure as part of a project to improve a residential environment for the low-income class, rather than the performance of high-priced humidity control materials that are produced with the existing plasticity processing. The testing methods included the measurements of absorption & desoprtion of humidity per material; Mock-up Testing; an evaluation method of comparing the absorption & desoprtion performances of Ecocarat, ceramic panels and painting materials through Living Lab. According to the measurements of absorption & desoprtion per material, ceramic panels, E panel, and ceramic painting material showed 73.3g/m2, 96.6g/m2, and 111.1g/m2, respectively. That is, the performance of humidity control of each material was found to be good in the order of: Ceramic Paint > E panel > Ceramic Panel. According to performance evaluation testing with Mock-up test and Living Lab, Ceramic Paint, Ecocarat, and Ceramic Panels showed better absorption & desoprtion performances in the order.

Early Age Properties of HPC Columns under Construction-Site Conditions

  • Yun, Ying-Wei;Jang, Il-Young
    • International Journal of Concrete Structures and Materials
    • /
    • v.2 no.1
    • /
    • pp.63-68
    • /
    • 2008
  • High performance concrete (HPC) is widely used in civil engineering due to its high durability and low permeability etc. Compared with ordinary concrete, HPC may develop much higher AS (autogenous shrinkage) at early age due to the relative low water cement (w/c) ratio and adding of mineral admixtures, which is one of the main reasons for early age micro-cracking of HPC structures. This paper studies the early age property of HPC columns under similar construction-site surroundings by embedded strain transducers. Results show that for HPC structure, early-age autogenous shrinkage especially within the first day after concrete pouring is pretty large. AS within the first day are 60% larger than those for 14 days in this research for all specimens. Therefore it should be taken into account for structure durability. By comparison of PHPC (plain HPC column) and RHPC (reinforced HPC column) specimens, the effects of reinforced bars on AS and temperature distribution have been analyzed. Also the influence of w/c ratio on AS is demonstrated.

A study on micro punching process of ceramic green sheet (세라믹 그린시트의 미세 비아홀 펀칭 공정 연구)

  • 신승용;주병윤;임성한;오수익
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2003.10a
    • /
    • pp.101-106
    • /
    • 2003
  • Recent electronic equipment becomes smaller, more functional, and more complex. According to these trends, LTCC(low temperature co-fired ceramic) has been emerged as a promising technology in packaging industry. It consists of multi-layer ceramic sheet, and the circuit has 3D structure. In this technology via hole formation plays an important role because it provides an electric path for the packaging interconnection network. Therefore via hole quality is very important for ensuring performance of LTCC product. Via holes are formed on the green sheet that consists of ceramic(before sintering) layer and PET(polyethylene Terephthalate) one. In this paper we found the correlation between hole quality and process condition such as ceramic thickness, and tool size. The shear behavior of double layer sheet by micro hole punching which is different from that of single layer one was also discussed.

  • PDF

Performance Test of Low Temperature Waste Heat Recovery Heat Exchanger Using Self-excited Oscillating Heat Pipe (자려 진동형 히트 파이프를 이용한 저온 폐열 회수 열교환기의 성능 실험)

  • 이욱현;이종현;김종수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.9
    • /
    • pp.853-859
    • /
    • 2000
  • In this study, low temperature waste heat recovery heat exchanger was developed using a principle of self-excited oscillating heat pipe. The heat exchanger of serpentine type was composed of extruded flat aluminum tube with 6 channels (3 nm$\times$ 2.75nm) and louvered fin. The heat transfer area density of heat exchanger was $331.9 m^2/m^3$. Working fluid is R141b and charge ratio was 40% by volume. Heat transfer rate and the effectiveness of heat exchanger was primary concern of this study. As a result, the effectiveness of heat exchanger was about 0.4-0.67, and recovered waste heat rate was about 4.5 kW per one unit of heat exchanger.

  • PDF

3.5-Inch QCIF AMOLED Panels with Ultra-low-Temperature Polycrystalline Silicon Thin Film Transistor on Plastic Substrate

  • Kim, Yong-Hae;Chung, Choong-Heui;Moon, Jae-Hyun;Lee, Su-Jae;Kim, Gi-Heon;Song, Yoon-Ho
    • ETRI Journal
    • /
    • v.30 no.2
    • /
    • pp.308-314
    • /
    • 2008
  • In this paper, we describe the fabrication of 3.5-inch QCIF active matrix organic light emitting display (AMOLED) panels driven by thin film transistors, which are produced by an ultra-low-temperature polycrystalline silicon process on plastic substrates. The over all processing scheme and technical details are discussed from the viewpoint of mechanical stability and display performance. New ideas, such as a new triple-layered metal gate structure to lower leakage current and organic layers for electrical passivation and stress reduction are highlighted. The operation of a 3.5-inch QCIF AMOLED is also demonstrated.

  • PDF

Solenoid Type 3-D Passives(Inductors and Trans-formers) For Advanced Mobile Telecommunication Systems

  • Park, Jae Y.;Jong U. Bu
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.2 no.4
    • /
    • pp.295-301
    • /
    • 2002
  • In this paper, solenoid-type 3-D passives (inductors and transformers) have been designed, fabricated, and characterized by using electroplating techniques, wire bonding techniques, multi-layer thick photoresist, and low temperature processes which are compatible with semiconductor circuitry fabrication. Two different fabrication approaches are performed to develop the solenoid-type 3-D passives and relationship of performance characteristics and geometry is also deeply investigated such as windings, cross-sectional area of core, spacing between windings, and turn ratio. Fully integrated inductor has a quality factor of 31 at 6 GHz, an inductance of 2.7 nH, and a self resonant frequency of 15.8 GHz. Bonded wire inductor has a quality factor of 120, an inductance of 20 nH, and a self resonant frequency of 8 GHz. Integrated transformers with turn ratios of 1:1 and n:l have the minimum insertion loss of about 0.6 dB and the wide bandwidth of a few GHz.

Electrical Properties and Structures of Spinel Type LiMn$_{2-y}$M$_y$O$_4$(M=Cr$^{3+}$) Doped with Transition Metal (전이금속으로 치환된 Spinel형 LiMn$_{2-y}$M$_y$O$_4$(M=Cr$^{3+}$)의 구조 및 전기적 성질)

  • 형경우;김중헌;권태윤
    • Journal of the Korean Ceramic Society
    • /
    • v.36 no.9
    • /
    • pp.930-936
    • /
    • 1999
  • For LiMn2O4 based spinel structures the stoichiometric reaction conditions need be considered carefully because the electrical properties depend on the structural stability. In order to obtain the homogeneous compound the Pechini process was chosen which could obtain a stoichiometry phase even low temperature and dependency of the synthetic condition on structural stability and electrochemical performance was investigated. X-ray diffraction studies showed that the compounds doped with transition metal have smaller lattice constants than those un doped. The dc conductivity was evaluated by a four probe method in the low and high temperature region respectively. The variations of basal spacings for the cathode were detected to be dependent on the extent of current flows (under dc)

  • PDF