• Title/Summary/Keyword: Low Power Test

Search Result 1,425, Processing Time 0.032 seconds

Combustion characteristics of two imported Indonesia coals as a pulverized fuel of thermal power plants (인도네시아산 발전용 수입 석탄 2종의 연소특성 비교 평가)

  • Lee, Hyun-Dong;Kim, Jae-Kwan
    • Journal of Energy Engineering
    • /
    • v.19 no.2
    • /
    • pp.136-142
    • /
    • 2010
  • Combustion reactivity and thermal behavior of two imported coals used as a pulverized fuel of commercially thermal power plant were investigated by thermogravimetric analysis (TGA) and large scale test furnace of 200 kg/hr. TGA results showed that combustion efficiency of high moisture coal has lower than reference coal due to the slow combustion completion rate although it has the low ignition temperature, and activation energies of high moisture coal with 79 kJ/mol for overall combustion was higher than reference coal of 53 kJ/mol. Test furnace results ascertained that flame of black band of high moisture coal during the combustion in boiler broke out compared to reference coal and then it becomes to unburned carbon due to the less reactivity and combustion rate. But, Blending combustion of high moisture coal with design coal of high sulfur are available because sulfur content of high moisture coal was too low to generate the low SOx content in flue gas from boiler during the combustion. The ash analysis results show that it was not expected to be associated with slagging and fouling in pulverized coal fired systems due to the low alkali metal content of $Na_2O$ and $K_2O$ compared to bituminous coal.

Comparing Quantitative EEG and Low Resolution Electromagnetic Tomography Imaging between Deficit Syndrome and Non-Deficit Syndrome of Schizophrenia (정신분열병의 결핍증후군과 비결핍증후군에서 QEEG와 sLORETA를 이용한 비교연구)

  • Lee, Sang-Eun;Yim, Seon-Jin;Lee, Mi-Gyung;Lee, Jae-Won;Han, Kyu-Hee;Lee, Jong-Il;Sim, Min-Young;Yoon, Hai-Joo;Shin, Byoung-Hak
    • Sleep Medicine and Psychophysiology
    • /
    • v.17 no.2
    • /
    • pp.91-99
    • /
    • 2010
  • Objectives: Deficit schizophrenia (DS) constitutes a disease separate from non-deficit schizophrenia (NDS). The aim of the current study was to compare the quantitative EEG and low resolution electromagnetic tomography (LORETA) imaging between DS and NDS. Methods: This study was performed by 32 channels EEG for 42 schizophrenia patients who we categorized into DS and NDS using proxy instrument deficit syndrome (PDS). We performed the absolute power spectral analyses for delta, theta, alpha, low beta and high beta activities. We compared power spectrum between two groups using Independent t-test. Partial correlation test was performed with clinical parameters. Standardized LORETA (sLORETA) was used for comparison of cortical activity, and statistical nonparametric mapping (SnPM) was applied for the statistical analysis. Results: DS showed significantly increased delta and theta absolute power in fontal and parietal region compared with NDS (p<0.05). Power spectrum showed significant correlation with 'anergia' and 'hostility/suspiciousness' subscale of brief psychiatric rating scale (BPRS)(p<0.05). sLORETA found out the source region (anterior cingulate cortex/limbic part) that delta activity was significantly increased in DS (p=0.042). Conclusions: DS showed different cortical activity compared with NDS. Our results may suggest QEEG and LORETA could be the marker in differentiating between DS and NDS.

  • PDF

Effect of RF Superimposed DC Magnetron Sputtering on Electrical and Bending Resistances of ITO Films Deposited on PET at Low Temperature (DC마그네트론 스퍼터링법으로 PET 기판위에 저온 증착한 ITO박막의 비저항과 굽힘 저항성에 대한 RF인가의 영향)

  • Park, Mi-Rang;Lee, Sung-Hun;Kim, Do-Geun;Lee, Gun-Hwan;Song, Pung-Keun
    • Journal of Surface Science and Engineering
    • /
    • v.41 no.5
    • /
    • pp.214-219
    • /
    • 2008
  • Indium tin oxide (ITO) films were deposited on PET substrate by RF superimposed DC magnetron sputtering using ITO (doped with 10 wt% $SnO_2$) target. Substrate temperature was maintained below $750^{\circ}C$ without intentionally substrate heating during the deposition. The discharge voltage of DC power supply was decreased from 280 V to 100 V when superimposed RF power was increased from 0 W to 150 W. The electrical properties of the ITO films were improved with increasing of superimposed RF power. In the result of cyclic bending test, relatively high mechanical property was obtained for the ITO film deposited with RF power of 75 W under DC current of 0.75 A which could be attributed to the decrease of internal stress caused by decrease in both deposition rate and plasma impedance.

Centrifugal Clutch Design for an Unmanned Helicopter - Theoretical Analysis of Power Transfer - (농용 무인헬리콥터의 원심클러치 설계 - 동력 전달의 이론분석 -)

  • Lee, J.H.;Koo, Y.M.;Shin, S.K.
    • Journal of Biosystems Engineering
    • /
    • v.33 no.1
    • /
    • pp.14-20
    • /
    • 2008
  • An agricultural unmanned helicopter was suggested for an alternative to current pesticide application methods to solve such problems as high cost, low efficiency, shirking task and unsafe work. To pursuit this trend, researches on the development of unmanned helicopters have been accelerated in Korea as well. In this research, a guide type centrifugal clutch that plays an important role in the unmanned helicopter was studied. Theoretical analyses and experimental tests were conducted for designing an optimal clutches. Main design factors of the guide type centrifugal clutch were found to be spring constant, free length of spring, mass of friction sector, contact area, allowable pressure, number of friction sector, friction coefficient, radius of drum, and clutch arrangement. And these design factors could be the functions of engaging engine speed and desired power transfer capacity. The result of the single clutch test showed the power transfer capacity of 14.1 PS at 5,800 rpm and the result of the dual clutch test showed that the capacity of 17.7 PS at 5,600 rpm. These experimental results agreed well the theoretical simulations.

Design Analysis and Economic Analysis of high Efficiency 100kW Generator for Hydro Power System (소수력 발전용 고효율 100kW 발전기의 설계해석 및 경제성 분석)

  • Jee, In-Ho;Kang, Seung-Jin
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.3
    • /
    • pp.428-438
    • /
    • 2016
  • This paper shows the design of the 100 kW IPMSG for small hydraulic power generator. The high-efficient generator, method of the dual layer interior permanent magnet was studied to improve the method of the single layer interior permanent magnet, which is mostly used. Analysis of magnet arrangement and cogging torque was done by FEM. According to structure analysis of dual layer interior permanent magnet, the amount of usage of the permanent magnet was reduced and cogging torque was decreased as well. With these successful results, the high-efficient generator design was accomplished. Based on the results of the structure analysis, the test product was designed and manufactured. And the design values and performance outputs were compared and verified with success. Also, the economic feasibility was conducted based on the electric power generated from the test product installed at the site. By the B/C analysis, in case that only SMP was analyzed, B/C ratio was 1.24 at the discount ratio of 5.5%, which considered to be economically feasible. The study is expected to be used for the application of developing large scale high-efficient interior permanent magnet synchronous generator.

Development of 460V/225A/50㎄ Contact System in Current Limiting Molded Case Circuit Breakers

  • Park, Young-Kil;Park, Chan-Kyo
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.3B no.4
    • /
    • pp.165-172
    • /
    • 2003
  • Low voltage circuit breakers are widely used in power distribution systems to interrupt fault current rapidly and to assure the reliability of the power supply. This paper is focused on understanding the interrupting capability, more specifically of the contacts and the arc runner, based on the shape of the contact system in the current molded case circuit breaker (hereafter MCCB). Moreover, in order to improve the interrupting capability of the circuit breaker, the estimation and analysis of the interrupting capability, based on the 3-D magnetic flux analysis, were developed. Furthermore, this paper also presents results of the estimation and analysis of the interrupting capability when applied to different model breakers. In addition, this paper analyzes the efficiency of the interrupting tests by forming false current paths consisting of a three-division cascade arc runner in the contact system. With regards to the interrupting test, there is a need to assure that the optimum design required to analyze the electromagnetic forces of the contact system generated by the current and flux density be present. Based on the results of this study, this paper presents both computational analysis and test results for the newly developed MCCB 460V/225A/50㎄ contact system.

A novel approach for optimal DG allocation in distribution network for minimizing voltage sag

  • Hashemian, Pejman;Nematollahi, Amin Foroughi;Vahidi, Behrooz
    • Advances in Energy Research
    • /
    • v.6 no.1
    • /
    • pp.55-73
    • /
    • 2019
  • The cost incurred by voltage sag effect in power networks has always been of important concern for discussions. Due to the environmental constraints, fossil fuel shortage crisis and low efficiency of conventional power plants, decentralized generation and renewable based DG have become trends in recent decades; because DGs can reduce the voltage sag effect in distribution networks noticeably; therefore, optimum allocation of DGs in order to maximize their effectiveness is highly important in order to maximize their effectiveness. In this paper, a new method is proposed for calculating the cost incurred by voltage sag effect in power networks. Thus, a new objective function is provided that comprehends technical standards as minimization of the cost incurred by voltage sag effect, active power losses and economic criterion as the installation and maintenance costs of DGs. Considering operational constraints of the system, the optimum allocation of DGs is a constrained optimization problem in which Lightning Attachment procedure optimization (LAPO) is used to resolve it and is the optimum number, size and location of DGs are determined in IEEE 33 bus test system and IEEE 34 bus test system. The results show that optimum allocation of DGs not only reduces the cost incurred by voltage sag effect, but also improves the other characteristics of the system.

A Study on the Fault Current Characteristics for the Utility Application of HTS Power cable (초전도 전력케이블의 전력계통 적용을 위한 고장전류 특성에 관한 연구)

  • Kim, Jae-Ho;Park, Min-Won;Sim, Ki-Deok;Cho, Jeon-Wook;Yu, In-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.75-76
    • /
    • 2007
  • Several kinds of High Temperature Superconducting(HTS) power cables have already been developed and evaluated for use in the utility power network. HTS power cable is expected to be used as a very powerful energy delivery system supplying electric power for densely populated cities in the near future, because HTS power cable is capable of the high current density delivery with low AC loss and the size effect comparing with the conventional cable whose capacity is same. Before applying the HTS power cable to real utility network system analysis should be carried out by some simulation tools. Hereby the electrical power system analysis is very important for the practical use of HTS power devices. In this paper, authors propose a real-time simulation method which incorporates a real HTS tapes into the simulated 22.9kV utility power network system using Real Time Digital Simulator(RTDS). For the simulation analysis, a test sample of HTS tapes was actually manufactured, and the transient phenomenon of HTS power cable system was analyzed in the simulated utility power network.

  • PDF

Global Healthcare Information System

  • Singh, Dhananjay;Lee, Hoon-Jae;Chung, Wan-Young
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2008.10a
    • /
    • pp.365-368
    • /
    • 2008
  • This paper presents a new concept of IP-based wireless sensor networks and also introduces a routing protocol that is based on clustering for global healthcare information system. Low-power wireless personal area networks (LoWPANs) conform the standard by IEEE 802.15.4-2003 to IPv6 that makes 6lowpan. It characterized by low bit rate, low power, and low cost as well as protocol for wireless connections. The 6lowpan node with biomedical sensor devices fixed on the patient body area network that should be connected to the gateway in personal area network. Each 6lowpan nodes have IP-addresses that would be directly connected to the internet. With the help of IP-address service provider can recognize or analysis patient biomedical data from anywhere on globe by internet service provider equipments such as cell phone, PDA, note book. The system has been evaluated by technical verification, clinical test, user survey and current status of patient. We used NS-2.33 simulator for our prototype and also simulate the routing protocols. The result shows the performance of biomedical data packets in multi-hope routing as well as represents the topology of the networks.

  • PDF

Sensitivity analysis of numerical schemes in natural cooling flows for low power research reactors

  • Karami, Imaneh;Aghaie, Mahdi
    • Advances in Energy Research
    • /
    • v.5 no.3
    • /
    • pp.255-275
    • /
    • 2017
  • The advantages of using natural circulation (NC) as a cooling system, has prompted the worldwide development to investigate this phenomenon more than before. The interesting application of the NC in low power experimental facilities and research reactors, highlights the obligation of study in these laminar flows. The inherent oscillations of NC between hot source and cold sink in low Grashof numbers necessitates stability analysis of cooling flow with experimental or numerical schemes. For this type of analysis, numerical methods could be implemented to desired mass, momentum and energy equations as an efficient instrument for predicting the behavior of the flow field. In this work, using the explicit, implicit and Crank-Nicolson methods, the fluid flow parameters in a natural circulation experimental test loop are obtained and the sensitivity of solving approaches are discussed. In this way, at first, the steady state and transient results from explicit are obtained and compared with experimental data. The implicit and crank-Nicolson scheme is investigated in next steps and in subsequent this research is focused on the numerical aspects of instability prediction for these schemes. In the following, the assessment of the flow behavior with coarse and fine mesh sizes and time-steps has been reported and the numerical schemes convergence are compared. For more detail research, the natural circulation of fluid was modeled by ANSYS-CFX software and results for the experimental loop are shown. Finally, the stability map for rectangular closed loop was obtained with employing the Nyquist criterion.