• 제목/요약/키워드: Low Power Test

검색결과 1,415건 처리시간 0.029초

Development of Monitoring and Control System of Utility-Pipe Conduit (Power Tunnel) using PLC

  • Lee, Tae-Young;Park, Byung-Seok;Ju, Seong-Ho;You, Dong-Hee;Lim, Yong-Hoon;Song, Seok-Young
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.116-119
    • /
    • 2004
  • The existing monitoring and control systems of utility-pipe conduit (power tunnel, cable tunnel etc) have established communication lines using optical fiber, leaky coaxial cable (LCX), and several kinds of control cable. Due to the properties of the used media, the cost of equipment is considerably high and the maintenance of the system is difficult. Also, the term of carrying out is long so that the extension of the system is in difficulty. Now it is desirable to adopt Power Line Communication (hereinafter, PLC) technology in the monitoring and control systems and use the existing low-voltage power-line for lamplight as communication line. This will lead the reduction of the construction cost and the easy maintenance of the system. In this paper, we research the characteristics of PLC in conduit, design and manufacture the field test system, and analyze the performance of the system by field test. Then, we introduce the reliable monitoring and control system of utility-pipe conduit using PLC.

  • PDF

초음파에 의한 발전소 고온배관재료의 크리프손상 평가 (Creep Damage Evaluation of High-Temperature Pipeline Material for Fossil Power Plant by Ultrasonic Test Method)

  • 이상국;정민화
    • 한국해양공학회지
    • /
    • 제13권2호통권32호
    • /
    • pp.99-107
    • /
    • 1999
  • Boiler high-temperature pipelines such as main steam pipe, header and steam drum in fossil power plants are degraded by creep damage due to severe operationg conditions which are high temperature and high pressure for an extended period time. Such material degradation leads to various component failures causing serious accidents at the plants. Conventional measurement techniques such as replica method, electric resistance method, and hardness test method have such disadvantages as complex preparation and measurement procedures, too many control parameters, and therefore, low practicality and they were applied only to component surfaces with good accessibility. In this paper, artificial creep degradation test and ultrasonic measurement for their creep degraded specimens have been carried out for the purpose of evaluation for creep damage which can occur in high-temperature pipeline of fossil power plant. Absolute measuring method of quantitative ultrasonic measurement for material degradation was established, and long term creep degradationtests using life prediction formula were carried out. As a result of ultrasonic tests for crept specimens, we confirmed that the sound velocity decreased and the attenuation coefficient linearly increased in proportion to the increase of creep fractiin(${\phi}$c).

  • PDF

Co60 Gamma-Ray Effects on the DAC-7512E 12-Bit Serial Digital to Analog Converter for Space Power Applications

  • Shin, Goo-Hwan
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권6호
    • /
    • pp.2065-2069
    • /
    • 2014
  • The DAC-7512E is a 12-bit digital to analog converter that is low power and a single package with internal buffers. The DAC-7512E takes up minimal PCB area for applications of space power electronics design. The spacecraft mass is a crucial point considering spacecraft launch into space. Therefore, we have performed a TID test for the DAC-7512E 12-bit serial input digital to analog converter to reduce the spacecraft mass by using a low-level Gamma-ray irradiator with $Co^{60}$ gamma-ray sources. The irradiation with $Co^{60}$ gamma-rays was carried out at doses from 0 krad to 100 krad to check the error status of the device in terms of current, voltage and bit error status during conversion. The DAC-7512E 12-bit serial digital to analog converter should work properly from 0 krad to 30 krad without any error.

Improved Transmitter Power Efficiency using Cartesian Feedback Loop Chip

  • Chong, Young-Jun;Lee, Il-Kyoo;Oh, Seung-Hyeub
    • Journal of electromagnetic engineering and science
    • /
    • 제2권2호
    • /
    • pp.93-99
    • /
    • 2002
  • The Cartesian loop chip which is one of key devices in narrow-band Walky-Talky transmitter using RZ-SSB modulation method was designed and implemented with 0.35 Um CMOS technology. The reduced size and low cost of transmitter were available by the use of direct-conversion and Cartesian loop chip, which improved the power efficiency and linearity of transmitting path. In addition, low power operation was possible through CMOS technology. The performance test results of transmitter showed -23 dBc improvement of IMD level and -30 dEc below suppression of SSB characteristic in the operation of Cartesian loop chip (closed-loop). At that time, the transmitting power was about 37 dBm (5 W). The main parameters to improve the transmitting characteristic and to compensate the distortion in feed back loop such as DC-offset, loop gain and phase value are interfaced with notebook PC to be controlled with S/W.

통합연료필터의 저온유동성 시험장치 핵심기술개발 (Core Technology Development of Low Temperature Fluidity Test System with Composited Fuel Filter)

  • 윤석창;조상;윤달환
    • 전기전자학회논문지
    • /
    • 제18권3호
    • /
    • pp.420-426
    • /
    • 2014
  • 본 연구에서는 저온유동성 성능검사 시스템 구현을 통해 디젤 차량용 통합형 연료필터의 성능을 평가한다. 저온유동성시험 장치의 시험조건은 경유(또는 등유)를 사용하고, 상온, -20 및 $-30^{\circ}C$ 에서 경유공급압력 $3.4kgf/cm^2$, 연료공급량 60 l/H, 설정전류 30 A 및 전압은 $13V_{dc}$를 사용한다. 시료시험으로 통합필터를 지그에 장착하고, 경유(또는 등유)를 일정압력과 유량으로 설정하여 챔버 탱크와 필터에 채운 후, 설정시간 동안 설정온도로 냉각한 후, 필터 전후에 따라 유압과 시동시간, 히터의 소모전류 및 전력을 측정한다.

Effective Sample Sizes for the Test of Mean Differences Based on Homogeneity Test

  • Heo, Sunyeong
    • 통합자연과학논문집
    • /
    • 제12권3호
    • /
    • pp.91-99
    • /
    • 2019
  • Many researchers in various study fields use the two sample t-test to confirm their treatment effects. The two sample t-test is generally used for small samples, and assumes that two independent random samples are selected from normal populations, and the population variances are unknown. Researchers often conduct F-test, the test of equality of variances, before testing the treatment effects, and the test statistic or confidence interval for the two sample t-test has two formats according to whether the variances are equal or not. Researchers using the two sample t-test often want to know how large sample sizes they need to get reliable test results. This research gives some guidelines for sample sizes to them through simulation works. The simulation had run for normal populations with the different ratios of two variances for different sample sizes (${\leq}30$). The simulation results are as follows. First, if one has no idea equality of variances but he/she can assume the difference is moderate, it is safe to use sample size at least 20 in terms of the nominal level of significance. Second, the power of F-test for the equality of variances is very low when the sample sizes are small (<30) even though the ratio of two variances is equal to 2. Third, the sample sizes at least 10 for the two sample t-test are recommendable in terms of the nominal level of significance and the error limit.

PWR환경을 모사한 저주기 피로실험장치 국산화 (Development of Low-Cycle Fatigue Test Rig in Simulated PWR Environments)

  • 정일석;김상재;이용성;홍승열
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.178-183
    • /
    • 2004
  • For developing fatigue design curve of cast stainless steels that would be used in piping material of domestic nuclear power plants, a low-cycle fatigue test rig was built. It is capable of performing tests in pressurized high temperature water environment of PWR. Cylindrical specimens of CF8M were used for the strain-controlled environmental fatigue tests. Fatigue life was measured in terms of the number of cycles with the variation of strain amplitude at 0.04%/s strain rates. The disparity between target length and measured length of specimens was corrected by using finite element method. The corrected test results showed similar fatigue life trend with another previous results.

  • PDF

열상장비용 스터링 극저온 냉동기 특성평가 (III) : 열환경시험 (The performance evaluation of Stirling cryocooler for thermal imaging system (III) : Thermal environmental test)

  • 김양훈;박성제;홍용주;김효봉;고득용;이승홍;나종문
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 추계학술대회 논문집
    • /
    • pp.163-166
    • /
    • 2003
  • This paper presents the results of a series of performance tests for the Stilting cryocooler. Infrared sensor systems incorporating cryocoolers are required to be qualified to the appropriate environmental specification. Linear drive Stilting cryocooler have matured to the stage of undergoing formal qualification test program The thermal environmental test of the Stilting cryocooler is presented in this paper. We performed that low and high temperature keeping test from -4$0^{\circ}C$ to +6$0^{\circ}C$ and operating test at high and low temperature cyclic range with acceptance tests performed at scheduled intervals. Cooling capacity was determined as a function of cooler components temperatures at the compressor, hot end and cold tip. Tests performed on this cooler have been successful with a measured cooling performance of more than 0.8W@80K for 23$^{\circ}C$ ambient temperature with 40 $W_{ac}$ input power.

  • PDF

니켈카드뮴 축전지의 성능시험 분석 (An Analysis of Performance Test Results for Nickel-Cadmium Battery)

  • 온정근;김명룡;김원경;홍용기
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2003년도 추계학술대회 논문집(III)
    • /
    • pp.600-605
    • /
    • 2003
  • Battery of rolling stock is a very important device as power supply at starting and emergency control. This paper analyzes the quality of Ni-Cd battery by means of performance test. Ni-Cd battery have suitable and stable properties. That is very stable to discharge on low temperature state and very easy to manage and repair. This paper confirm the performance and property of Ni-Cd battery on low temperature environment by the performance test and estimate the life-cycle of Ni-Cd battery on board at rolling-stock by the life-test and the using-test.

  • PDF