• 제목/요약/키워드: Low Power Operation

검색결과 2,005건 처리시간 0.027초

장거리 공대공 데이터링크를 위한 저전력 웨이브폼 설계 (Design of Power Efficient Waveforms for Long Range Air-to-Air Data Links)

  • Haeuk Lee;Je Heo;Gijung Yang;Taehee Lim;Hyukjun Oh
    • 한국항행학회논문지
    • /
    • 제28권2호
    • /
    • pp.250-253
    • /
    • 2024
  • This paper proposes a low-power waveform for a long-range air-to-air data link. In the case of an air-to-air data link, data communication is performed in the air and high Doppler shift may occur depending on the flight speed, so a waveform based on the non-coherent method is suitable. In addition, since it is mounted on an aircraft, it must have low power characteristics. This paper proposes a waveform that combines a modulation technique based on frequency modulation and pulse position modulation that can turn on/off the transmission signal. As a result of the performance analysis, it was shown that the performance was suitable for air-to-air operation while showing low power characteristics.

유도발전기 역률 보상 콘덴서와 직렬 리액터의 동작 분석 (Operating Analysis of Power Factor Compensation Condenser and Series Reactor in the Induction Generator)

  • 김종겸;박영진
    • 전기학회논문지
    • /
    • 제66권3호
    • /
    • pp.593-598
    • /
    • 2017
  • Induction generator is always required reactive power in order to generate a rotating magnetic field as an inductive load. The reactive power must be continuously supplied to the induction generator as well as load of distribution system from the power supply side. So the power factor of the power supply side during the induction generation operation is low. Condenser is installed in order to raise the low power factor of the induction generator. Switching transients occurs when the power supply of the capacitor is turned on in order to ensure the low power factor. When using the reactor in series with the capacitor in order to reduce the influence of switching transient, it can affect the reactive power by the condenser voltage rises. In this study, we analyzed the operating characteristics for power and power factor of induction generator in accordance with the presence or absence of the application of the serial reactors for switching transients reduction of the condenser and the condenser for power factor correction.

Pager 동작 시간 향상을 위한 POCSAG Signal Decoder의 설계 (Design of POSCAG signal decoder for operating time improvement in pager)

  • 최종문;김영대;한정익
    • 한국통신학회논문지
    • /
    • 제22권2호
    • /
    • pp.361-370
    • /
    • 1997
  • In this paper, we designed POCSAG Signal Decoder to improve operating time in pager. We showed POCSAG Signal Pattern sent by transmitter and operation of this decoder. We also showed that the Pager using this decoder was equipped with Wide Area Signal Detection and designed the hardware which realizes this operation and implemented it with ASIC chip. As we inspected the function of the ASIC chip and tested the performance, we could find that the chip operated in low voltage and that power dissipation was low.

  • PDF

Sub-10 nm Ge/GaAs Heterojunction-Based Tunneling Field-Effect Transistor with Vertical Tunneling Operation for Ultra-Low-Power Applications

  • Yoon, Young Jun;Seo, Jae Hwa;Cho, Seongjae;Kwon, Hyuck-In;Lee, Jung-Hee;Kang, In Man
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제16권2호
    • /
    • pp.172-178
    • /
    • 2016
  • In this paper, we propose a sub-10 nm Ge/GaAs heterojunction-based tunneling field-effect transistor (TFET) with vertical band-to-band tunneling (BBT) operation for ultra-low-power (LP) applications. We design a stack structure that is based on the Ge/GaAs heterojunction to realize the vertical BBT operation. The use of vertical BBT operations in devices results in excellent subthreshold characteristics with a reduction in the drain-induced barrier thinning (DIBT) phenomenon. The proposed device with a channel length ($L_{ch}$) of 5 nm exhibits outstanding LP performance with a subthreshold swing (S) of 29.1 mV/dec and an off-state current ($I_{off}$) of $1.12{\times}10^{-11}A/{\mu}m$. In addition, the use of the highk spacer dielectric $HfO_2$ improves the on-state current ($I_{on}$) with an intrinsic delay time (${\tau}$) because of a higher fringing field. We demonstrate a sub-10 nm LP switching device that realizes a good S and lower $I_{off}$ at a lower supply voltage ($V_{DD}$) of 0.2 V.

무선망에서 기지국의 전력소모에 대한 운영 방안 (A operation scheme to the power consumption of base station in wireless networks)

  • 박상준
    • 한국정보통신학회논문지
    • /
    • 제24권2호
    • /
    • pp.285-289
    • /
    • 2020
  • 무선 네트워크의 계층적 구성은 다양한 네트워크 환경을 지원하기 위해 제공된다. 기지국에서는 두 가지 시스템 상태가 기본적으로 고려될 수 있으며, 이에 대해 액티브와 슬립 모드 사이에서 상태 전이가 발생할 수 있다. 그러므로 에너지 사용을 줄이기 위하여 저전력의 시스템 운영 관리가 기지국 시스템에 고려되어야 한다. 따라서 본 논문에서는 시스템 관리를 다루기 위해 Discontinuous Reception (DRX) 분석 모델을 고려한다. DRX 모델을 통하여 기지국 시스템의 운영에 대한 분석 방안을 제시하며 에너지 소비를 위한 저전력 강도를 살펴본다. 또한 시스템 상태에서 기지국의 저전력 소모에 대한 성능을 분석하기 위해 무선 자원 요구와 서비스 호 도착의 운영이 고려되며, 이를 위하여 유한 마르코프 시스템 모델을 사용하였다.

SSR (Simple Sector Remapper) the fault tolerant FTL algorithm for NAND flash memory

  • Lee, Gui-Young;Kim, Bumsoo;Kim, Shin-han;Byungsoo Jung
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 ITC-CSCC -2
    • /
    • pp.932-935
    • /
    • 2002
  • In this paper, we introduce new FTL(Flash Translation Layer) driver algorithm that tolerate the power off errors. FTL driver is the software that provide the block device interface to the upper layer software such as file systems or application programs that using the flash memory as a block device interfaced storage. Usually, the flash memory is used as the storage devices of the mobile system due to its low power consumption and small form factor. In mobile system, the state of the power supplement is not stable, because it using the small sized battery that has limited capacity. So, a sudden power off failure can be occurred when we read or write the data on the flash memory. During the write operation, power off failure may introduce the incomplete write operation. Incomplete write operation denotes the inconsistency of the data in flash memory. To provide the stable storage facility with flash memory in mobile system, FTL should provide the fault tolerance against the power off failure. SSR (Simple Sector Remapper) is a fault tolerant FTL driver that provides block device interface and also provides tolerance against power off errors.

  • PDF

수동대기모드를 고려한 셋톱박스 모드전환 기술의 에너지 절감 성능 분석 (Power consumption evaluation of Set-top box mode transition scheme considering passive stand-by mode)

  • 김용호;김훈
    • 정보통신설비학회논문지
    • /
    • 제10권4호
    • /
    • pp.135-142
    • /
    • 2011
  • This paper proposes a performance evaluation method for power consumption of set-top box (STB) stand-by mode transition schemes. A stand-by mode transition scheme characterizes the timing of mode transition. The timing of mode transition affects the duration of stand-by mode operation, and the power consumptions of STB as well. Recently a fast stand-by mode transition scheme (FMT) has been proposed based on user input for selecting the device to be connected to TV. In this paper, we evaluate power consumption of FMT and a conventional mode transition scheme. For the computation of the duration of stand-by mode operation, the user input events are modeled as Poisson process. Simulation results based on the modeling reveals that the proposed scheme is more effective in power saving than the conventional scheme by up to 30%.

  • PDF

Multiple Brillouin Stokes Generation Utilizing a Linear Cavity Erbium-Doped Fiber Laser

  • AL-Mansoori, Mohammed Haydar;Noordin, Nor Kamariah;Saripan, M. Iqbal;Mahdi, Mohd Adzir
    • Journal of Communications and Networks
    • /
    • 제10권1호
    • /
    • pp.1-4
    • /
    • 2008
  • This paper reports the design of a multiwavelength fiber laser source that utilizes a linear cavity of hybrid Brillouin/Erbium fiber laser (BEFL). The output power, threshold power and free running cavity modes were investigated against the pump powers. The structure exhibited low threshold operation of 4 mW at 2.3 mW injected Brillouin pump power. The optimization of Brillouin pump wavelength, power and Erbium gain led to a maximum possible number of channels generated. Simultaneous and stable operation of 21 channels with 10.88 GHz channels spacing were obtained from this architecture at 1 mW injected Brillouin pump power and 90 m W Erbium doped fiber pump power in the 1555 nm region.

전원 전압 불평형시 계통연계형 인버터의 유효전력 리플 억제를 위한 듀얼 전류제어기 구현과 출력 전력의 실시간 제한 알고리즘 (Implementation of Dual Current Controller and Realtime Power Limiting Algorithm in Grid-connected Inverter during Unbalanced Voltage Conditions)

  • 송승호;김정재
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제55권1호
    • /
    • pp.54-60
    • /
    • 2006
  • A power limiting algorithm is proposed for stable operation of grid-connected inverter in case of grid voltage unbalance considering the operation limit of inverter. During the voltage unbalance the control performance of Inverter. is degraded and the output power contains 120Hz ripple due to the negative sequence of voltage. In this paper, conventional dual sequence current controller is implemented to solve these problems using separated control of positive and negative sequence. Especially the maximum power limit which guarantees the maximum rated current of the inverter is automatically calculated as the instant grid voltage changes. As soon as the voltage recovers the proposed algorithm can return to the normal power control mode accomplishing low voltage ride through. Proposed algorithm is verifed using PSCAD/EMTDC simulations and tested experimentally at 4.4kW wind turbine simulator set-up.

새로운 ZVS 3-레벨 공진폴 인버터 (A Novel ZVS 3-Level Resonant Pole Inverter)

  • 백주원;조정구;유동욱;송두익;원충언
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 A
    • /
    • pp.360-364
    • /
    • 1995
  • A zero voltage switching (ZVS) three level resonant pole inverter is presented for high power GTO inverters. The concept of auxiliary resonant commutated pole(ARCP) for two level inverter is extended to the three level inverter. The proposed auxiliary commutation circuit consists of one resonant inductor and two bi-directional switches, which provides ZVS condition to the main devices without increasing device voltage or current stresses. The auxiliary device operates with zero current switching(ZCS) which enables use of the low cost thyristors. The proposed circuit can handle higher voltage and higher power(1-10MVA) comparing to the two level one. Operation and analysis of the proposed circuit are illustrated. Experimental results with 10 KW, 4 kHz prototype are presented to verify the principle of operation.

  • PDF