• 제목/요약/키워드: Low Flow Rate

Search Result 1,938, Processing Time 0.039 seconds

Predictions of zinc selenide single crystal growth rate for the micro gravity experiments

  • Kim, Geug-Tae
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.14 no.5
    • /
    • pp.226-232
    • /
    • 2004
  • One predicts the crystal growth rate of ZnSe with a low vapor pressure system in a horizontal configuration based on one dimensional advection-diffusion and two-dimensional diffusion-convection model. The present results show that for the ratios of partial pressures, s = 0.2 and 2.9, the growth rate increases with the temperature differences between the source and crystal. As the ratio of partial pressure approaches the stoichiometric value, s = 2 from s = 1.5 (zinc-deficient case: s < 2) and 2.9 (zinc-rich case: s > 2), the rate increases sharply. For the ranges from 1.5 to 1.999 (zinc-deficient case: s < 2) and from s = 9 to 2.9 (zinc-rich case: s > 2), the rate are slightly varied. From the viewpoint of the order of magnitude, the one-dimensional model for low vapor pressure system falls within the 2D predictions, which indicates the flow fields would be advective-diffusive. For the effects of gravitational accelerations on the rate, the gravitational constants are varied from 1 g to $10^{-6}$ g for $\Delta$T = 50 K and s = 1.5, the rates remain nearly constant, i.e., 211 mg/hr, which indicates Stefan flow is dominant over convection.

Dynamic Deformation Behavior of Metal Matrix Composites Under Impact Loading (충격하중을 받는 금속복합재료의 동적변형거동에 관한 연구)

  • Kim, Moon-Saeng;Lee, Hyeon-Chul
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.7 s.94
    • /
    • pp.1772-1782
    • /
    • 1993
  • The characteristics of metal matrix composite under dynamic tension at high strain rates up to the order of $10^3/sec$ is studied by using newly developed apparatus. The composite material processed in this research is aluminum-alumina metal matrix composites, arid fabricated by compocasting with the fiber volume fraction from 5 to 20%. The whisker and matrix material used in this paper were ${\delta}-Al_2O_3$ and Al-6061, respectively. The mechanical tests performed in this research are low and high strain rate tensile test. At low strain-rate tensile test, the modulus of elasticity and the ultimate tensile strength of the composites were improved about 77 pct. and 55 pct., respectively comparing with the unreinforced materials. At strain-rate from $10^{-3}\;to\;10^3/s$, the effect of strain-rate on the modulus, ultimate strength, flow stress is determined. Also the effect of strain rate on the modulus, ultimate tensile strength, flow stress and elongation to failures were investigated.

Flow Rate Control of Gaseous Oxygen for a $HTPB/GO_2$ Hybrid Rocket ($HTPB/GO_2$ 하이브리드 로켓의 산화제 유량제어)

  • Oh Hwa-Young;Moon Sung-Hwan;Huh Hwanil
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2004.10a
    • /
    • pp.251-254
    • /
    • 2004
  • Hybrid rockets have many advantages over solid and liquid rockets. Hybrid rockets put forth high $I_{sp}$ like liquid rockets in spite of simple structure and low cost. As oxidizer flow rate is increased, thrust of hybrid rocket is increased accordingly. In this study, lab-scale hybrid rocket is designed, fabricated and tested. This system consists of lab-scale hybrid rocket motor, ignition system, flow system and data aquisition system. In order to control oxidizer flow rate, we construct flow rate control system by using needle valve and stepping motor.

  • PDF

A Study of Low-k Wafer Engraving Processes by Using Laser with Pico-second Pulse Width (자외선 피코초 레이저를 이용한 Low-k 웨이퍼 인그레이빙 특성에 관한 연구)

  • Moon, Seong-Wook;Bae, Han-Seong;Hong, Yun-Suk;Nam, Gi-Jung;Kwak, No-Heung
    • Journal of the Semiconductor & Display Technology
    • /
    • v.6 no.1 s.18
    • /
    • pp.11-15
    • /
    • 2007
  • Low-k wafer engraving process has been investigated by using UV pico-second laser with high repetition rate. Wavelength and repetition rate of laser used in this study are 355 nm and 80 MHz, respectively. Main parameters of low-k wafer engraving processes are laser power, work speed, assist gas flow, and protective coating to eliminate debris. Results show that engraving qualities of low-k layer by using a laser with UV pico-second pulse width and high repetition rate had better kerf edge and higher work speed, compared to one by conventional laser with nano-second pulse width and low repletion rate in the range of kHz. Assist gas and protective coating to eliminate debris gave effects on the quality of engraving edge. Total engraving width and depth are obtained less than $20\;{\mu}m$ and $10\;{\mu}m$ at more than 500 mm/sec work speed, respectively. We believe that engraving method by using UV pico-second laser with high repetition rate is useful one to give high work speed in laser material process.

  • PDF

The Distribution Characteristics of Organic Matters in the Contaminated Tributaries of Han River Region (한강권역 우심지류 하천의 유기물 분포 특성)

  • Kim, Ho-Sub;Park, Yun-Hee;Kim, Yong-Sam;Kim, Sang-Yong
    • Journal of Korean Society on Water Environment
    • /
    • v.34 no.5
    • /
    • pp.494-502
    • /
    • 2018
  • The purpose of this study was to understand distribution characteristics of organic matters through concentration of $BOD_5$, $COD_{Mn}$ and TOC in 31 streams in Han River region, and to establish the relationship among organic matter concentration, and discharge load and flow rate. Concentration of $BOD_5$ and TOC in 22 streams were above IV grade except 9, and the average 80.9 % of total organic matter (by TOC) accounted for dissolved organic type. Correlation among organic matter parameters were higher ($r^2$ > 0.78) and the relationship between TOC and $COD_{Mn}$ concentration was higher than $BOD_5$. Ratio of biodegradable organic matter/total organic matter in the 31 streams was estimated at 41.4 % with $BOD_5$ oxidation rate, and 78.0 % with $BOD_5/COD_{Mn}$ concentration ratio. Ratio of $NBOD/BOD_5$ concentration in four sites with $BOD_5/COD_{Mn}$ concentration ratio exceeding 1 ranged from 54.5 % ~ 79.3 %. Among 979 flow rate data measured at 31 streams, 87 % of measured data was below 0.1 cms and increased water pollution under low flow conditions. Correlation between $BOD_5$ concentration and $BOD_5$ discharge load in the watershed was low, and it was revealed that several streams have more $BOD_5$ delivery load than $BOD_5$ discharge load. Results suggest that many biodegradable forms of organic matter are being introduced into the stream from pollutant sources in the watershed.

Evaluation of Popping Performance of Safety Valves in City Gas Facilities (도시가스시설에서 안전밸브의 분출성능에 관한 평가 연구)

  • 김영규;김청균
    • Journal of the Korean Society of Safety
    • /
    • v.13 no.2
    • /
    • pp.104-108
    • /
    • 1998
  • In order to evaluate the performances of safety valves for low pressure, the popping pressure and flow rate of the natural gas have been investigated. The measured results of the popping pressure show that there is a big scattering depending on the manufacture year of a safety valve. And sample A showed the ideal popping pressure mode compared to other B and C samples. The popping flow rate of the safety valve is proportional to the seat size as the inlet pressure increases. These results may be used as a guideline for a design and diagnosis of the safety valve.

  • PDF

Uncertainty evaluation in electrochemical noise resistance measurement (전기화학적 노이즈 저항 측정에서의 불확도 평가)

  • Kim, Jong Jip;Kang, Su Yeon
    • Corrosion Science and Technology
    • /
    • v.12 no.5
    • /
    • pp.220-226
    • /
    • 2013
  • The uncertainty in statistical noise resistance measurement was evaluated for a type 316 stainless steel in NaCl solutions at room temperature. Sensitivity coefficients were determined for measurands or variables such as NaCl concentration, pH, solution temperature, surface roughness, inert gas flow rate and bias potential amplitude. The coefficients were larger for the variables such as NaCl concentration, pH, inert gas flow rate and solution temperature, and they were the major factors increasing the combined standard uncertainty of noise resistance. However, the contribution to the uncertainty in noise resistance measurement from the above variables was remarkably low compared to that from repeated measurements of noise resistance, and thus, it is difficult to lower the uncertainty in noise resistance measurement significantly by lowering the uncertainties related with NaCl concentration, pH, inert gas flow rate and solution temperature. In addition, the uncertainty in noise resistance measurement was high amounting to 17.3 % of the mean, indicating that the reliability in measurement of noise resistance is low.

Suppression of Cavitation in Inducer by J-Groove (J-그루브에 의한 인듀서의 캐비테이션 억제)

  • Kurokawa, Junichi;Choi, Young-Do
    • 유체기계공업학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.776-781
    • /
    • 2005
  • Cavitation is the most serious problem caused in developing high-speed turbopump, and use of an inducer is often made to avoid cavitation in main impeller. Thus, the inducer always operates under the worst condition of cavitation. If it could be possible to control and suppress cavitation in the inducer by some new device, it would also be possible to suppress cavitation occurring in all types of pumps. The purpose of our present study is to develop a new effective method of controlling and suppressing cavitation in an inducer using shallow grooves, named as "J-Groove", J-Groove is installed on the casing wall near the blade tip to use the pressure difference between high pressure region and low pressure region in the axial direction at the inlet of the inducer. The results show that proper combination of backward-swept inducer with J-Groove improves suction performance of turbopump remarkably in the range of partial flow rate as well as designed flow rate. The rotating backflow cavitation occurring in the range of low flow rate and the cavitation surge occurring in the vicinity of the best efficiency point can be almost fully suppressed by installing J-Groove.

  • PDF

A Study on the Suppression of Cavitation in Inducer by J-Groove (J-그루브를 이용한 인듀서의 캐비테이션 억제에 관한 연구)

  • Choi, Young-Do;Kurokawa, Junichi
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.11 s.242
    • /
    • pp.1239-1247
    • /
    • 2005
  • Cavitation is the most serious problem in developing high-speed turbopump, and inducer is often used to avoid cavitation in main impeller. Thus, inducer is always operating in the worst .cavitation condition. If it is possible to control and suppress cavitation in inducer by some new device, it might be possible to suppress cavitation occurring in any type of pumps. The purpose of present study is to develop a new effective method of controlling and suppressing cavitation in inducer using shallow grooves, which is named 'J-Groove'. J-Groove is installed on the casing wall near the blade tip to use the pressure difference between high pressure region and low pressure region of the inducer in an axial direction. The results show that proper combination of backward-swept inducer with J-Groove improves suction performance of turbopump remarkably in the range of partial flow rate as well as designed flow rate. The rotating backflow cavitation occurring in the range of low flow rate and the cavitation surge occurring in the vicinity of the best efficiency point can be almost suppressed by installing J-Groove.

Study on the Analysis of Development of Stage-Discharge Curve for Han River and Correlation between Items of Water Pollutants- Focused on Byeokgyeo Stream - (한강수계 유량곡선식 개발 및 수질오염물질 항목간 상관성 분석에 관한 연구- 벽계천 중심으로 -)

  • Hong, Sung-Ho;Ban, Jong-Seok;Jun, Hang-Bae
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.3
    • /
    • pp.394-400
    • /
    • 2012
  • We drew the stage-discharge relations of Byeokgye Stream, located in Yangpyeong-gun, Gyeonggi-do, and analysed the correlation between items of water pollutants by measuring the flow rate and water pollutants thirty-four times from April 2010 to December 2010. The results showed that it tended to be low water season from April to June and from October and December, while tending to be water season from July to September. The average flow rate was $2.137\;m^3/sec:\;0.464\;m^3/sec$ in low water season and $13.970\;m^3/sec$ in high water season. The stage-discharge curve thereon was $Q=40.107{\times}(h-1.200)^{2.877}$. As to the correlations, the correlation between the water temperature and COD was 0.58, and the correlations of SS with BOD and COD were 0.46 and 0.40 respectively. The correlation between SS and T-P was 0.73, showing higher than other items.