• Title/Summary/Keyword: Low Energy House

Search Result 144, Processing Time 0.026 seconds

Improvement of Energy Efficiency in Wood Frame House with Energy Efficient Methods (건물 에너지 절약요소 적용을 통한 목조주택의 에너지 성능 개선)

  • Kim, Sejong;Park, Joo-Saeng;Lee, Jun-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • v.41 no.1
    • /
    • pp.77-86
    • /
    • 2013
  • This research was carried out to evaluate and raise the energy efficiency of wood frame house. The commercial solution program CE3 (Construction Energy Efficiency Evaluation) was used for simulating the energy consumption in the single-family wood frame house. The results showed that the annual heating energy demand of the house was 160 kWh per 1 $m^2$ floor area. In order to decrease the heating energy demand, the following energy efficiency methods were applied to the simulation : a) simplification of building shape, b) decrease of windows area, c) application of high performance windows (with low thermal transmittance) and d) application of heat recovery ventilator. In case of replacement of the windows with high performance one with thermal transmittance 1 $W/m^2{\cdot}K$, the lowest heating demand of 80 $kWh/m^2{\cdot}a$ was obtained. The best combination of methods, application of high performance windows and heat recovery ventilator, showed heating energy demand 34.5 $kWh/m^2{\cdot}a$.

Air Tightness Performance of Residential Timber Frame Buildings

  • Kim, Hyun-Bae;Park, Joo-Saeng;Hong, Jung-Pyo;Oh, Jung-Kwon;Lee, Jun-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • v.42 no.2
    • /
    • pp.89-100
    • /
    • 2014
  • Energy consumption statistics in 2005 from the Korea Energy Management Corporation show that building energy usage was about 24.2% of total domestic energy consumption, and 64% of total building energy usage was consumed by residential buildings. Thus, about 10% of total domestic energy consumption is due to the heating of residential buildings. Building energy can be calculated by the configuration of the building envelope and the rate of infiltration (the volume of the infiltration of outdoor air and the leakage of indoor air), and by doing so, the annual energy usage for heating and cooling. Therefore, air-tightness is an important factor in building energy conservation. This investigate air infiltration and various factors that decrease it in timber frame buildings and suggest ways to improve air-tightness for several structural types. Timber frame buildings can be classified into light frame, post and beam, and log house. Post and beam includes Han-ok (a Korean traditional building). Six light frame buildings, three post and beam buildings, one Korean traditional Han-ok and a log house were selected as specimens. Blower door tests were performed following ASTM E779-03. The light frame buildings showed the highest air-tightness, followed by post and beam structures, and last, log houses.

Influence of Air-tightness on Heat Energy Performance in Post and Beam Building with Exposed Wood Frame

  • Kim, Hyun-Bae;Kim, Se-Jong;Oh, Jung-Kwon;Park, Joo-Saeng;Lee, Jun-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • v.40 no.5
    • /
    • pp.319-326
    • /
    • 2012
  • Han-green building is one of the modernized Korean traditional buildings developed by Korea Forest Research Institute. This building was developed to increase the competitiveness of Korean traditional building using state-of-art technologies; hence Han-green building has the inherent characteristics of traditional building such as exposed wood frame in wall. Because of discontinuity in wall by the exposed wood frame, there is a concern on heat-air leaking in terms of energy performance. In this study, air-tightness of Han-green building was evaluated to investigate the influence of gaps between frames and in-fill walls. Blower door test was carried out to evaluate the air-tightness, and air-change rate (ACH50) was evaluated by averaging four set of pressurization and depressurization test. The air-change rate of Han-green house was 5.91 $h^{-1}$. To improve energy performance of Han-green house, thermal infrared images of Han-green house were taken in winter with heating to find out where the heat loss occurred. It was found that the building lost more heat through gaps between frames and in-fill walls rather than through other parts of this building. After covering all the gaps by taping, the blower door test was performed again, and the air-change rate was improved to 5.25 $h^{-1}$. From this analysis, it was concluded that the heated air can leak through the gaps between frames and walls. Therefore, when one designs the post and beam building with exposed frame, the detail design between frame and wall needs to be carefully dealt. However, Han-green building showed relatively high air-tightness comparing with other country research results.

A Study on the Energy Saving Methods of a House by Passive System (건축적 수법을 통한 주택의 에너지 절약 방안에 관한 연구)

  • 김용식
    • Journal of the Korean housing association
    • /
    • v.13 no.2
    • /
    • pp.73-78
    • /
    • 2002
  • Recently, the energy consumption has been sharply increased and the environmental pollution has been serious, resulted in increased use of fossil fuel. These facts are applied to most fields, and are especially important issues in the field of architecture. The energy consumption rate of building is about 30% of all energy consumption, and the rate of residential is about 20% of the rate of building and is increasing gradually. The purpose of this article is firstly to analyse an actual energy consumption rate of model building and compare it with alternative methods, which are applied passive system to, and secondly to suggest an optimal passive method for saving energy. The conclusion of this study is as follows; 1) As compared with the existing house on actual energy consumption rate, 6% in changing orientation to a south, 9% in using double low-e glazing and 23% in shading is decreased. 2) The change of insulation from 50 to 100mm did not show dramatical difference in energy consumption rate. 3) As changed indoor temperature at 2$0^{\circ}C$ in winter and 27$^{\circ}C$ in summer, the rate shows a reduction of 14% compared with the existing condition.

The Analysis of Energy Cost Adopting an Electric Residence using Historical Energy Consumption Data (에너지소비 데이터를 이용한 전전화 주택 도입시 에너지 사용량 분석)

  • Lee, Jun-Kyu;Shin, Hee-Sang;Cho, Sung-Min;Lee, Hee-Tae;Jang, Sung-Kyu;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.6
    • /
    • pp.131-137
    • /
    • 2010
  • Change of the energy used in a house can be separated from LNG, and electric power. The electric power consumption of a house is more increasing than LNG. The interest for electric houses is rising due to energy saving and low carbon emission. Accordingly, the amount of energies and cost are analyzed consumed in a house using cumulative energy consumption. The result of analysis, amount of electric power, is more increase. In comparison, the use volume of city gas is more decrease. In this paper, the use volume of energy resource is analyzed using historical energy consumption data in the past 25 years. In addition, expected electrical power and heating energy is analysed adopting an Electric Residence.

Heating Energy Saving and Cost Benefit Analysis According to Low-Income Energy Efficiency Treatment Program - Case Study for Low-Income Detached Houses Energy Efficiency Treatment Program (저소득층 에너지효율개선사업에 따른 난방에너지 절감 효과 및 경제성 분석 - 저소득층 단독주택 단열개선을 중심으로 -)

  • Kim, Jeong-Gook;Lee, Junghun;Jang, Cheolyong;Song, Doosam;Yoo, Seunghwan;Kim, Jonghun
    • KIEAE Journal
    • /
    • v.16 no.5
    • /
    • pp.39-45
    • /
    • 2016
  • Purpose: The purpose of this study is to analyze the energy saving and cost benefit analysis of the Low-income Energy Efficiency Treatment Program supported by KOREF(Korea Energy Foundation). This program was launched in 2007 and performs building energy retrofit for the low-income and energy poverty houses. Method: Energy simulation and cost benefit analysis were accomplished for the low-income detached houses. The structure of detached house was a lot og block structure, wood frame (single glass) and concrete roof. Baseline model of the low-income detached houses was proposed. Result: Annual heating energy consumptions were decreased by about 3.2% with the window system replacement(Case 1), 9.3% with reinforcement of insulation(Case2), and 12.5% with both(Case 3) compared to those of baseline model. The construction cost will be recouped within 5 years for the Case 1, 3 years for the Case 2, and 3 years for the Case 3. Case 3 was the most cost beneficient construction method in the analyzed cases in this study.

Research on the heating performance of SCW heat pump system for residential house (주거용 건물의 지하수 이용 지열 히트펌프 시스템의 난방성능 특성에 관한 연구)

  • Kim, Ju-Hwa;Kim, Ju-Young;Hong, Won-Hwa;Ahn, Chang-Hwan
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2008.04a
    • /
    • pp.431-435
    • /
    • 2008
  • Geothermal heat pump system using standing column wells as their ground heat exchanger can be used as a highly efficient source of heating and cooling in massive buildings. But there is no case of a small scale residential house. So this study estimated heating coefficient of performance(COP) of geothermal heat pump system using standing column well type which is excellent in heat recovery in the residential house. As a result of analysis, The COP of heat pump is over average 6 and is excellent. And in consequence of making a comparative study according to the bleeding, the cop is higher in the case of bleeding. Therefore, bleeding affects the performance of the system. This study has shown performance result that stands on actual data. Therefore, this study provides ground data that needs when a low capacity of system designs for a residence with confidence elevation.

  • PDF

Characteristics of Temperature Distribution of Wall, Floor, Air and Hot Water by Burying the Excel Pipe on the Floor and Wall of a Container House (컨테이너하우스의 바닥과 벽면에 엑셀파이프 매설에 의한 벽면, 바닥, 공기, 온수의 온도분포 특성)

  • Cho, Dong-Hyun
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.21 no.2
    • /
    • pp.94-100
    • /
    • 2022
  • A study was conducted to significantly increase the heat transfer area by simultaneously burying the excel pipe in the floor and wall of a container house, thereby greatly reducing the initial heating time. In addition, a small hot water boiler suitable for the heating load of a small container house with a maximum area of 6 m2 was studied. A wall-mounted hot water boiler was developed as a result of the study. When a hot water boiler is installed outdoors for heating, heat radiation energy is lost in winter from the hot water boiler and hot water pipe due to the low temperature. We propose an approach through which the energy loss was greatly reduced and the temperature of hot water increased in proportion to the operating time. Moreover, as the mass flow rate of the hot water flowing inside the excel pipe increased, the temperature of the hot water decreased. The temperature of the wall and floor surfaces of the container house increased in proportion to the increase in the mass flow rate of hot water flowing inside the excel tube. Natural convection heat transfer was realized from the wall and floor surfaces of the container house, and the heat transfer area was increased by a factor of 3 with respect to heat transfer area limited to the floor by the existing hot water panel. As a result, the initial temperature increase rate was much higher because of the larger heat transfer area.

A Fundamental Study for Development of Unglazed Transpired Collector Control System in Windowless Pig House (무창돈사 내 무창기공형 집열기 제어 시스템 개발을 위한 기초적 연구)

  • Moon, Byeong Eun;Kim, Hee Tae;Kim, Jong Goo;Ryou, Young Sun;Kim, Hyeon Tae
    • Journal of agriculture & life science
    • /
    • v.50 no.2
    • /
    • pp.175-185
    • /
    • 2016
  • In this study, manufactured experimental pig house (two pig house) and compared the changes in internal temperature and energy depending on the application of UTC control system for their utilizing of them as basic data for maintaining proper conditions for feeding environment and reducing heating energy depending on the UTC control system and program development, prior to applying the UTC system into pig house, representative agricultural facility. The control system ranges T1~T4 which is made to control a total of five output signals O1~O5 in the way of On/Off by using the algorithms of the program after measuring temperature scored 4 of total. Temperature setting was controlled with 28.0℃ in experimental pig house and 34.0℃ in UTC plenum, and output signal was controlled by comparing it with the measured temperature. During 3 days, the maximum temperature were measured at an average 31.8℃ when operated the control system in pig house. At the same time, the maximum temperature were measured 36.6℃ in comparison pig house, it was low temperature at 4.8℃ in experimental pig house than comparison pig house. Also, UTC plenum temperature was showed that rose at an average 50.5℃ by operation of the control program.

Characteristics and case study of Low Carbon Green City planning from the perspective of Urban Metabolism (도시 신진대사 관점에서 본 저탄소 녹색도시 계획특성 및 사례 분석)

  • Choi, Joung-Eun;Kim, Jong-Kon;Oh, Deog-Seong
    • KIEAE Journal
    • /
    • v.11 no.5
    • /
    • pp.3-12
    • /
    • 2011
  • Industrialization and development of technology satisfied various humanly needs and lay the basis of numerous benefit and profit. New technologies like these mostly required large amounts of fossil Fuel, Fossil energy depletion rate was increasing rapidly. However, technical development for Human race required absolute sacrifice of the environment. Especially, 'City' which had been focused as stage of human activities, allowed to continue to have fossil energy dependent activities, and it shows in many data that the city is responsible for the 75-80% of the green house gas by human. In order to solve the problem relating climate changes and energy, European countries already made progress studies on many of the low carbon green city and pilot case construction. Especially, Germany, Austria, Holland, Sweden who had been playing leader role on environmental awareness and ecological concept, are actively constructing low carbon green city project based on Ecological city planning scheme. These projects positively utilize planning scheme that limits carbon emission using Urban Metabolism concept. Therefore, throughout this study, I would like to present planning and direction of future domestic low carbon green city by analyzing theories relative theories and best practices in Europe.