• Title/Summary/Keyword: Low Density Range

Search Result 662, Processing Time 0.032 seconds

Combustion Characteristics of a Hot Water Boiler System Convertibly Fueled by Rice Husk and Heavy Oil - Heavy Oil Combustion Characteristics -

  • Kim, Myoung Ho;Kim, Dong Sun;Park, Seung Je
    • Journal of Biosystems Engineering
    • /
    • v.38 no.4
    • /
    • pp.306-311
    • /
    • 2013
  • Purpose: With the ever-rising energy prices, thermal energy heavily consuming facilities of the agricultural sector such as commercialized greenhouses and large-scale Rice Processing Complexes (RPCs) need to cut down their energy cost if they must run profitable businesses continually. One possible way to reduce their energy cost is to utilize combustible agricultural by-products or low-price oil instead of light oil as the fuel for their boiler systems. This study aims to analyze the heavy oil combustion characteristics of a newly developed hot water boiler system that can use both rice husk and heavy oil as its fuel convertibly. Methods: Heavy oil combustion experiments were conducted in this study employing four fuel feed rates (7.6, 8.5, 9.5, 11.4 $l/h$) at a combustion furnace vacuum pressure of 500 Pa and with four combustion furnace vacuum pressures (375, 500, 625, 750 Pa) at fuel feed rates of 9.5 and 11.4 $l/h$. Temperatures at five locations inside the combustion furnace and 20 additional locations throughout the whole hot water boiler system were measured to ascertain the combustion characteristics of the heavy oil. From the temperature measurement data, the thermal efficiency of the system was calculated. Flue gas smoke density and concentrations of air-polluting components in the flue gas were also measured by a gas analyzer. Results: As the fuel feed rate or combustion furnace vacuum pressure increased, the average temperature in the combustion furnace decreased but the thermal efficiency of the system showed no distinctive change. On the other hand, the thermal efficiency of the system was inversely proportionally to the vacuum level in the furnace. For all experimental conditions, the thermal efficiency remained in the range of 80.1-89.6%. The CO concentration in the flue gas was negligibly low. The NO and $SO_2$ concentration as well as the smoke density met the legal requirements. Conclusions: Considering the combustion temperature characteristics, thermal efficiency, and flue gas composition, the optimal combustion condition of the system seemed to be either the fuel feed rate of 9.5 $l/h$ with a combustion furnace vacuum pressure of 375 Pa or a fuel feed rate of 11.4 $l/h$ with a furnace vacuum pressure between 500 Pa and 625 Pa.

Longitudinal Change in Health Status after the Sewol Ferry Accident among Bereaved Parents (세월호 참사 후 희생자 부모의 건강상태 변화)

  • Yang, Sang Eun;Tae, Hye Jin;Hwang, Jihyun;Chae, Jeong-Ho
    • Anxiety and mood
    • /
    • v.14 no.1
    • /
    • pp.44-52
    • /
    • 2018
  • Objective : The present study had examined the psychiatric symptoms and physical health consequences for the bereaved parents of the high school students who died in the 2014 Sewol ferry accident. Methods : Forty bereaved parents participated in the study. The authors administered self-report questionnaires about the parents' health behaviors and psychiatric symptoms. The authors also conducted laboratory tests to assess the parents' physical health at 18 and 30 months after the accident. Univariate descriptive statistics were performed to report the prevalence and severity of psychiatric symptoms and health-related behaviors. Paired t-test and Mcnemar test were performed to compare the 18-and 30-month findings. Correlation analysis between psychiatric symptoms and laboratory findings were performed to find a relationship between the two variables. Results : At 30 months after the accident, most of the bereaved parents still appeared to suffer from complicated grief (97.5%), post traumatic stress disorder (80%), insomnia (77.5%) and severe depression (62.5%) based on the scores on the Inventory of Complicated Grief (ICG), the PTSD Check List-5 (PCL-5), the Insomnia Severity Index (ISI) and the Patient Health Questionnaire-9 (PHQ-9). One quarter of the bereaved parents reported high-risk drinking, and 47.5% reported increased drinking amount and frequency after the accident. In objective laboratory results, 55% of the bereaved parents were obese as defined by body mass index ${\geq}25$. The parents' mean low-density lipoprotein shows a significant increase over time (118.5 mg/dL at 18 months. vs. 132.5 mg/dL at 30 months. paired t-test t=-4.061, $$p{\leq_-}0.001$$). Total cholesterol and low-density lipoprotein at 30 months after the accident were in clinically borderline high range. In correlation analysis, triglyceride was positively correlated with ISI. Conclusion : The loss of children in the Sewol ferry accident, a disaster caused by human error, continued to have considerable impact on the victims' parents' mental and physical health 18 and 30 months after the accident. A longitudinal study following the parents' physical health would be necessary to investigate the long-term effects of this traumatic experience on physical health.

Performance Evaluation of Aqueous Organic Redox Flow Battery Using Methylene Blue and Vanadium Redox Couple (메틸렌블루와 바나듐을 활물질로 활용한 수계 유기 레독스 흐름 전지의 성능 평가)

  • Lee, Wonmi;Kwon, Yongchai
    • Korean Chemical Engineering Research
    • /
    • v.56 no.6
    • /
    • pp.890-894
    • /
    • 2018
  • In this study, methylene blue which is one of dye materials was introduced as active material for aqueous redox flow battery. The redox potential of methylene blue was shifted to negative direction as pH increased. The full-cell performance was evaluated by using methylene blue as the negative active material and vanadium as the positive active material with acid supporting electrolytes. The cell voltage of methylene $blue/V^{4+}$ is very low (0.45 V). In addition, the maximum solubility of methylene blue in water is only 0.12 M. Therefore, the cell test was performed with very low concentration (0.0015 M methylene blue, $0.15M\;V^{4+}$) at first time. Cut-off voltage range was 0 to 0.8 V and $1mA{\cdot}cm^{-2}$ current density was adopted during cycling. As a result, current efficiency (CE) was 99.67%, voltage efficiency (VE), 88.83% and energy efficiency (EE) was 85.87% and discharge capacity was ($0.0500Ah{\cdot}L^{-1}$) at 4 cycle. In addition, the cell test was performed with increased concentration (0.1 M methylene blue, $0.15M\;V^{4+}$) with $10mA{\cdot}cm^{-2}$ current density, leading to higher discharge capacity ($3.8122Ah{\cdot}L^{-1}$) with similar efficiency (CE=99%, VE=85%, EE=85% at 4 cycle).

Influence of Additives on Densification of Low-Temperature PZT Ceramics (저온소성용 PZT 세라믹스의 치밀화에 미치는 첨가제의 영향)

  • Park, Yong-Kap
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.5
    • /
    • pp.995-999
    • /
    • 2007
  • The lead zirconate titanate (PZT) powders were synthesized to make the piezoelectric ceramics in low temperature as low as $900^{\circ}C$. To investigate the influence of additives on sintering of PZT, two kinds of sintering aids were made as follows; $wB_2O_3-xBi_2O_3-zCuO$and LiBiO2-CuO. The sintering aid, $1{\sim}3$ wt.% $LiBiO_2-CuO$, was added into these PZT powders and the specimens were fired at temperature in the range of $800{\sim}1200^{\circ}C$. The highest density was shown in the specimen with 1 wt.% $LiBiO_2-CuO$ as additive at temperature of $900^{\circ}C$. The sintered specimen were analyzed by X-ray diffraction(XRD) and scanning electron microscopy (SEM) was utilized to observe the microstructure, especially the densified morphology of specimens. In the XRD pattern, the well-crystallized PZT phase could be obtained in consequence of firing at $900^{\circ}C$. The scanning electron microscopy(SEM) was utilized to observe the structure of specimens after firing at $900^{\circ}C$. The densified perovskite structure of $PbZrTiO_3$ could be obtained by sintering at temperature as low as $900^{\circ}C$. The high sinterability of PZT ceramics was attributed to the low formation temperature of the liquid phase of additives.

  • PDF

Characterization of Sandwiched MIM Capacitors Under DC and AC Stresses: Al2O3-HfO2-Al2O3 Versus SiO2-HfO2-SiO2 (Al2O3-HfO2-Al2O3와 SiO2-HfO2-SiO2 샌드위치 구조 MIM 캐패시터의 DC, AC Stress에 따른 특성 분석)

  • Kwak, Ho-Young;Kwon, Hyuk-Min;Kwon, Sung-Kyu;Jang, Jae-Hyung;Lee, Hwan-Hee;Lee, Song-Jae;Go, Sung-Yong;Lee, Weon-Mook;Lee, Hi-Deok
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.12
    • /
    • pp.939-943
    • /
    • 2011
  • In this paper, reliability of the two sandwiched MIM capacitors of $Al_2O_3-HfO_2-Al_2O_3$ (AHA) and $SiO_2-HfO_2-SiO_2$ (SHS) with hafnium-based dielectrics was analyzed using two kinds of voltage stress; DC and AC voltage stresses. Two MIM capacitors have high capacitance density (8.1 fF/${\mu}m^2$ and 5.2 fF/${\mu}m^2$) over the entire frequency range and low leakage current density of ~1 nA/$cm^2$ at room temperature and 1 V. The charge trapping in the dielectric shows that the relative variation of capacitance (${\Delta}C/C_0$) increases and the variation of voltage linearity (${\alpha}$/${\alpha}_0$) gradually decreases with stress-time under two types of voltage stress. It is also shown that DC voltage stress induced greater variation of capacitance density and voltage linearity than AC voltage stress.

Effect of Tetracycline Analogues on The Activity of Matrix Metalloproteinase-3 in Gingival Fibroblasts (테트라사이클린계 약물이 치은섬유아세포내 MMP-3의 활성도에 미치는 영향)

  • Cho, Jong-Hee;Kim, Sang-Mok;Kim, Byung-Ock;Han, Kyung-Yoon
    • Journal of Periodontal and Implant Science
    • /
    • v.29 no.3
    • /
    • pp.677-693
    • /
    • 1999
  • Extracellular matrix component is degraded by enzymes of thematrix metalloproteinases(MMPs). MMPs are produced by both hemopoietic and structural cells. Increased activity of MMP-3 in periodontium is strongly associated with inflammatory periodontal disease. The purpose of the present study was to determine the effect of tetracycline analogues on the activity of MMP-3. Tetracycline-HCl, doxycycline-HCl, and minocycline-HCl were applied to huamn gingival fibroblasts at various concentrations of 10, 25, 50, 100, 200${\mu}g$/ml, and 1 hour later IL-$1{\beta}$ of 25ng/ml was added. After incubation for 24 hours the cells were reacted by enzyme-linked immunosorbent assay using proMMP-3 ELISA kit. The optical density was measured by microwell plate reader at 450nm. The relative activity of MMP-3 was calculated as the percentage of the optical density of each experimental group to that of the control. The difference of the optical density and the relative activity of MMP-3 between the experimental groups and the control wasstatistically analyzed by one way ANOVA. The results were as follows: 1. Tetracycline-HCl showed the tendency to inhibit the activity of MMP-3 at the concentration lower than 25${\mu}g$/ml, but increased significantly the activity of MMP-3 at the concentration of 200${\mu}g$/ml(p<0.05). 2. Doxycycline-HCl inhibited significantly the activity of MMP-3 at the concentration lower than 100${\mu}g$/ml, but increased significantly the activity of MMP-3 at the concentration of 200${\mu}g$/ml(p<0.05). 3. Minocycline-HCl inhibited the activity of MMP-3 at the concentration in the range of 10 to 200${\mu}g$/ml. Within the limit of the present study, the above results suggested that the low concentration of tetracycline analogues could inhibit the activity of MMP-3 induced by IL-$1{\beta}$ in human gingival fibroblasts.

  • PDF

Structural characterization of nonpolar GaN using high-resolution transmission electron microscopy (HRTEM을 이용한 비극성 GaN의 구조적 특성 분석)

  • Kong, Bo-Hyun;Kim, Dong-Chan;Kim, Young-Yi;Ahn, Cheol-Hyoun;Han, Won-Suk;Choi, Mi-Kyung;Bae, Young-Sook;Woo, Chang-Ho;Cho, Hyung-Koun;Moon, Jin-Young;Lee, Ho-Seong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.23-23
    • /
    • 2009
  • GaN-based nitride semiconductors have attracted considerable attention in high-brightness light-emitting-diodes (LEDs) and laser diodes (LDs) covering from green to ultraviolet spectral range. LED and LD heterostructures are usually grown on (0001)-$Al_2O_3$. The large lattice mismatch between $Al_2O_3$ substrates and the GaN layers leads to a high density of defects(dislocations and stacking faults). Moreover, Ga and N atoms are arranged along the polar [0001] crystallographic direction, which leads to spontaneous polarization. In addition, in the InGaN/GaN MQWs heterostructures, stress applied along the same axis can also give rise to piezoelectric polarization. The total polarization, which is the sum of spontaneous and piezoelectric polarizations, is aligned along the [0001] direction of the wurtzite heterostructures. The change in the total polarization across the heterolayers results in high interface charge densities and spatial separation of the electron and hole wave functions, redshifting the photoluminescence peak and decreasing the peak intensity. The effect of polarization charges in the GaN-based heterostructures can be eliminated by growing along the non-polar [$11\bar{2}0$] (a-axis) or [$1\bar{1}00$] (m-axis) orientation instead of thecommonly used polar [0001] (c-axis). For non-polar GaN growth on non-polar substrates, the GaN films have high density of planar defects (basal stacking fault BSFs, prismatic stacking fault PSFs), because the SFs are formed on the basal plane (c-plane) due to their low formation energy. A significant reduction in defect density was recently achieved by applying blocking layer such as SiN, AlN, and AlGaN in non-polar GaN. In this work, we were performed systematic studies of the defects in the nonpolar GaN by conventional and high-resolution transmission electron microscopy.

  • PDF

Luminescence Identification Characteristics for Irradiated Dried Fishery Products (조사처리한 건조수산품의 전처리 방법에 따른 Luminescence 판별 특성)

  • Kim, Moon-Young;Ahn, Jae-Jun;Kim, Gui-Ran;Kwak, Ji-Young;Park, Kun-Sang;Lee, Kyung-Jin;Kwon, Joong-Ho
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.42 no.11
    • /
    • pp.1837-1842
    • /
    • 2013
  • Photostimulated luminescence (PSL) and thermoluminescence (TL) analyses were conducted for the detection of different gamma-irradiated dried fishes (mussel, squid, beka squid, mitra squid, plaice, and saury) at 0, 1, 5 and 10 kGy. For TL analysis, the contaminating silicate minerals were obtained by density separation or acid hydrolysis treatment. PSL determinations indicated that all the non-irradiated samples showed PSL photon counts/60 s (PCs) lower than 700 PCs (negative), but the irradiated mussel sample at 5 and 10 kGy were only possibility identified showing higher than 5000 PCs (positive). Irrespective of sample kinds and methods of mineral separation, all the non-irradiated samples showed TL glow curves in low-intensity with a maximum peak only after $250^{\circ}C$. However, all the irradiated samples produced TL glow curves in high intensity with a maximum peak particularly in the temperature range of 1$150{\sim}250^{\circ}C$. In conclusion, more distinguishable TL results [glow curve, TL ratio ($TL_1/TL_2$)] were obtained from the marker minerals separated by acid hydrolysis rather than density method.

The Effect of Urban Trees on Residential Solar Energy Potential (도심 수목이 분산형 주거 태양광에너지 잠재량에 미치는 영향)

  • Ko, Yekang
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.42 no.1
    • /
    • pp.41-49
    • /
    • 2014
  • This study spatially assesses the impact of trees on residential rooftop solar energy potential using urban three-dimensional models derived from Light Detection and Ranging(LiDAR) data in San Francisco, California. In recent years on-site solar energy generation in cities has become an essential agenda in municipal climate action plans. However, it can be limited by neighboring environments such as shade from topography, buildings and trees. Of all these effects, the impact of trees on rooftop photovoltaics(PVs) requires careful attention because improper situation of solar panels without considering trees can result in inefficient solar energy generation, tree removal, and/or increasing building energy demand and urban heat island effect. Using ArcMap 9.3.1, we calculated the incoming annual solar radiation on individual rooftops in San Francisco and the reduced insolation affected by trees. Furthermore, we performed a multiple regression analysis to see what attributes of trees in a neighborhood(tree density, tree heights, and the variance of tree heights) affect rooftop insolation. The result shows that annual total residential rooftops insolation in San Francisco is 18,326,671 MWh and annual total light-loss reduction caused by trees is 326,406 MWh, which is about 1.78%. The annual insolation shows a wide range of values from $34.4kWh/m^2/year$ to $1,348.4kWh/m^2/year$. The result spatially maps the locations that show the various levels of impact from trees. The result from multiple regression shows that tree density, average tree heights and the variation of tree heights in a neighborhood have statistically significant effects on the rooftop solar potential. The results can be linked to municipal energy planning in order to manage potential conflicts as cities with low to medium population density begin implementing on-site solar energy generation. Rooftop solar energy generation makes the best contribution towards achieving sustainability when PVs are optimally located while pursuing the preservation of urban trees.

Assessment of Power Generation by Pressure Retarded Osmosis Process from Spiral-Wound Membrane Pilot-Plant (나권형 모듈을 이용한 압력지연삼투 공정의 에너지생산에 관한 연구)

  • Go, Gil hyun;Park, Tae shin;Kang, Lim seok
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.9
    • /
    • pp.476-481
    • /
    • 2016
  • Pressure retarded osmosis (PRO) is a quite new technique for power generation using an osmotically driven membrane process. In the PRO process, water permeates through a semipermeable membrane from a low concentration feed solution to a high concentration draw solution due to osmotic pressure. This study carried out to evaluate the performance of the 8 in spiral wound membrane module using reverse osmosis concentrate for a draw solution and reverse osmosis permeate for a feed solution. Three different flowrates of draw and feed solution, such as 2.4 L/min, 5.0 L/min, and 10.0 L/min were used to estimate the power density and water flux under various range of hydraulic pressure differences between 5 bar and 30 bar. In addition, the effects of feed and draw solution concentration, flowrate, and mixing ratio on 8 in spiral wound PRO membrane module performance were investigated in this study. As major results, increases of the draw solution concentration lead to the improvement of power denstiy, and water flux. Also, increase of flowrate resulted in the improvement of power density and water flux. In addition, optimal mixing ratio of draw and feed solution inlet flowrate was found to be 1:1 to attain a maximum power denstiy.