• 제목/요약/키워드: Low Density Range

검색결과 660건 처리시간 0.024초

Shearing Properties of Hard Metal Powder and Iron Powder in the Low Density Range

  • Jonsen, P.;Haggblad, H.A.
    • 한국분말야금학회:학술대회논문집
    • /
    • 한국분말야금학회 2006년도 Extended Abstracts of 2006 POWDER METALLURGY World Congress Part2
    • /
    • pp.1296-1297
    • /
    • 2006
  • Both plastic and elastic properties change dramatically from the beginning to the end of the compaction phase. Previous investigations have shown that powder transfer and high powder flow during initial compaction at low density affects the strength of the final component significantly. Investigated here are shear failure and elastic shear modulus in the low density range for hard metal powder and for pre-alloyed water atomized iron powder. Direct shear test equipment for sand and clay has been modified to measure the shearing properties of powder for an axial loading between 1 kPa and 500 kPa.

  • PDF

SIZE OF THE CLUSTERS UNDER LOW DENSITY ZERO-RANGE INVARIANT MEASURES

  • Jeon, In-Tae
    • 대한수학회논문집
    • /
    • 제20권4호
    • /
    • pp.813-826
    • /
    • 2005
  • Regarding all particles at a fixed site as a cluster, the size of the largest cluster under the zero range invariant measures is well studied by Jeon et al.[5] for the case of density one. Here, the density of the finite zero-range process is given by the ratio between the number m of particles and the number n of sites. In this paper, we study the lower density case, i.e., the case m = o(n). Especially, when m ~ $n^{\beta}$,0 < ${\beta}$ < 1, we show that there is an interesting cutoff point around $\beta$ = 1/2.

낮은 최고전류밀도 조건에서 파형전류전해에 의한 Pb-Sn합금 전착층의 조성 및 조작특성 (Composition and microstructure of Pb-Sn alloy electrodeposits in pulse plating with low peak current density)

  • 예길촌;백민석
    • 한국표면공학회지
    • /
    • 제24권2호
    • /
    • pp.88-95
    • /
    • 1991
  • The tin-lead alloy was electrodeposited in the low range of peak current density in order to investigate the change of composition and microstructure of them. The Pb content of alloy deposits, which was decreased with increasing average current density, was relatively lower than that of D.C. plated alloy deposit. The preferred orientation of alloy deposit was changed with increasing peak current density and the surface morphology of alloy deposits was closely related to the preferred orientation of them.

  • PDF

저비중 SMC 외장패널의 피로특성 평가 (An Evaluation of the Fatigue Properties for External Panel Using Low Density SMC)

  • 김은성
    • 한국생산제조학회지
    • /
    • 제21권5호
    • /
    • pp.830-835
    • /
    • 2012
  • A research for application of LDSMC(Low Density Sheet Molding Compound) composite is in progress for lightening the weight. This paper has performed fatigue test and simulation of external panel for Korean commercial vehicle. Before the fatigue test, static test was carried out. From the test, the structural safety was investigated using Goodman diagram. After the static test performance, the fatigue test was conducted at a range of load frequency 5Hz, a stress ratio(R) of 0.05 and an endurance limit of $10^6$ to obtain the S-N curve. The S-N curve is applied to the fatigue analysis of the external panel assembly. The result of FEM analysis was in accord with the experimental result within 83% confidence. It showed that the process to set up the safety range of allowable error is required in process of the design and simulation verification.

고속도금된 Zn-Cr 및 Zn-Cr-X 3원합금 도금층의 표면조직, 광택도 및 경도 (Surface morphology, Glossiness and Hardness of Zn-Cr and Zn-Cr-X ternary alloy Electrodeposits)

  • 예길촌;김대영;서경훈
    • 한국표면공학회지
    • /
    • 제36권5호
    • /
    • pp.379-385
    • /
    • 2003
  • The surface morphology, the glossiness and the hardness of Zn-Cr and Zn-Cr-X(X:Co, Mn) alloy electrodeposits were investigated by using chloride bath with EDTA additive and flow cell system. The surface morphology of Zn-Cr alloy and Zn-Cr-Mn alloy changed from fine needle shape crystalline structure to colony structure of fine granular crystallites with increasing current density in the range of 20-100 $A/dm^2$. The surface morphology of Zn-Cr-Co alloy deposited from low Co concentration bath(2.5-10 g/$\ell$) was similar to that of Zn-Cr alloy, while that of Zn-Cr-Co alloy deposited from high cobalt concentration bath was fine granular crystalline structure in the same range of current density. The glossiness of Zn-Cr and Zn-Cr-Mn alloy increased noticeably with increasing current density, while that of Zn-Cr-Mn alloy decreased with increasing Mn concentration of bath in high current density region. The glossiness of Zn-Cr-Co alloy deposited from low Co concentration bath increased with current density while that of the alloy from high Co concentration bath decreased with increasing current density. The hardness of Zn-Cr and Zn-Cr-X alloy increased noticeably with current density.

Continuous Low-Dose Temozolomide Chemotherapy and Microvessel Density in Recurrent Glioblastoma

  • Woo, Jong-Yun;Yang, Seung Ho;Lee, Youn Soo;Lee, Su Youn;Kim, Jeana;Hong, Yong Kil
    • Journal of Korean Neurosurgical Society
    • /
    • 제58권5호
    • /
    • pp.426-431
    • /
    • 2015
  • Objective : The purpose of this study was to evaluate the clinical efficacy of continuous low-dose temozolomide (TMZ) chemotherapy for recurrent and TMZ-refractory glioblastoma multiforme (GBM) and to study the relationship between its efficacy and microvessel density within the tumor. Methods : Thirty patients who had recurrent GBM following Stupp's regimen received TMZ daily at $50mg/m^2/day$ until tumor progression between 2007 and 2013. The median duration of continuous low-dose TMZ administration was 8 weeks (range, 2-64). Results : The median progression-free survival (PFS) of continuous low-dose TMZ therapy was 2 months (range, 0.5-16). At 6 months, PFS was 20%. The median overall survival (OS) from the start of this therapy to death was 6 months (95% CI : 5.1-6.9). Microvessel density of recurrent tumor tissues obtained by reoperation of 17 patients was $22.7{\pm}24.1/mm^2$ (mean${\pm}$standard deviation), and this was lower than that of the initial tumor ($61.4{\pm}32.7/mm^2$) (p-value=0.001). It suggests that standard TMZ-chemoradiotherapy reduces the microvessel density within GBM and that recurrences develop in tumor cells with low metabolic burden. The efficacy of continuous low-dose TMZ could not be expected in recurrent GBM cells in poor angiogenic environments. Conclusion : The efficacy of continuous low-dose TMZ chemotherapy is marginal. This study suggests the need to develop further treatment strategies for recurrent and TMZ-refractory GBM.

저밀도 폴리에틸렌 박막의 전기적 특성에 미치는 전자선의 영향 (The Effect of Electron Beam Irradiation on the Electrical Characteristics of Low Density Polyethylene film (I))

  • 조돈찬;신종열;차광훈;이수원;홍진웅
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1996년도 추계학술대회 논문집
    • /
    • pp.82-85
    • /
    • 1996
  • It is considered that the effect of radiation aging, such as electron beam due to the ultra-high voltage for transmission, on the physical properties and electrical characteristics of electrital insulating materials. Low-density polyethylene(thickness 100[${\mu}{\textrm}{m}$]) is selected as an experimental specimen. Fourier transform infra-red spectrum, X-ray diffraction, differential scanning calorimetry and scanning electron microscopy is used so as to analysis the physical properties, the morphological changes and the crystallinity of LDPE. And it is made an experiments of dielectric characteristics in the temperature range of 20[$^{\circ}C$]~120[$^{\circ}C$], in the frequency range of 30[Hz]~1.5$\times$10$^{5}$ [Hz] and in the applied voltage range of 300[mV]~1500[mV].

  • PDF

저밀도 USN 환경을 위한 Range-hybrid 기반의 향상된 이동객체 추적기법 (An Enhanced Mobile Object Tracking Method based on Range-hybrid for Low-Density USN Environment)

  • 박재복;조기환
    • 전자공학회논문지CI
    • /
    • 제47권2호
    • /
    • pp.54-64
    • /
    • 2010
  • 위치측정은 사용자나 사물에게 주변 환경에 대한 인식을 가능케 하는 기본적인 요소이기 때문에 센서네트워크 환경에서는 가장 핵심적인 요소이다. 기존 위치측정 기법은 크게 Range-based방식과 Range-free방식으로 나눌 수 있다. Range-based방식은 전파의 불규칙하고 추가 장비가 필요한 반면에 Range-free방식은 능동적인 통신을 수단으로 위치를 측정하므로 자원제약적인 센서네트워크에서는 적합한 것으로 알려져 있다. 그러나 위치측정의 정확성이 주변노드의 수에 따라 크게 좌우된다. 특히 밀집도가 낮은 센서네트워크 환경에서는 위치측정의 정확성이 매우 낮다. 본 논문에서 제안된 DRTS(Distributed Range-hybrid Tracking Scheme)는 Range-based와 Range-free방식을 혼합하고 주변노드의 위치와 통신범위 및 세기정보를 최대한 활용하여 이동물체를 추적할 수 있는 기법을 제시한다. 특히 주변노드를 최대한 활용한 효율적인 위치측정기법과 제안된 EGP(Estimative Gird Points)의 예측기법을 활용하여 위치추적의 정확성을 획기적으로 개선할 수 있는 방안을 제시한다. 그리고 시뮬레이션 결과를 통해 기존 위치추적 알고리즘 보다 추적의 정확도 관점에서 제안된 기법의 성능이 우수함을 증명하였다.

Electrical Properties and Dielectric Characteristics CCT-doped Zn/Pr-based Varistors with Sintering Temperature

  • Nahm, Choon-Woo
    • Transactions on Electrical and Electronic Materials
    • /
    • 제10권3호
    • /
    • pp.80-84
    • /
    • 2009
  • The microstructure, voltage-current, capacitance-voltage, and dielectric characteristics of CCT doped Zn/Pr-based varistors were investigated at different sintering temperatures. As the sintering temperature increased, the average grain size increased from 4.3 to 5.1 ${\mu}m$ and the sintered density was saturated at 5.81 g $cm^{-3}$. As the sintering temperature increased, the breakdown field decreased from 7,532 to 5,882 V $cm^{-1}$ and the nonlinear coefficient decreased from 46 to 34. As the sintering temperature increased, the donor density, density of interface states, and barrier height decreased in the range of (9.06-7.24)${\times}10^{17}\;cm^{-3}$, (3.05-2.56)${\times}10^{12}\;cm^{-2}$, and 1.1-0.95 eV, respectively. The dielectric constant exhibited relatively low value in the range of 529.1-610.3, whereas the $tan{\delta}$ exhibited a high value in the range of 0.0910-0.1053.

플라즈마 파동의 분산관계 측정에 관한 연구 (Measurement of Dispersion Relation of Plasma Wave)

  • 정중현;이종규
    • 수산해양기술연구
    • /
    • 제33권3호
    • /
    • pp.248-258
    • /
    • 1997
  • The analytical solutions of the Fraunhofer Diffraction(FD) theory and the principle for measurement of the dispersion relation of plasma wave is presented. Especially, the method for measurement of low-frequency wave is discussed. The wavenumbers of the density fluctuations are obtained from the curve fitting between the expremental FD profile and theoretical one for each frequency component. In measurement of the wavenumber of the low -frequency region, the information of the wavenumber is easily obtained from the ratio of the intensity at = 0 to the intensity at =0.5. The millimeter wave FD apparatus was designed to measure low-frequency density fluctuations. The determined wavenumbers are in the range of =0.1~ 1.0cm. Thus, the millimeter wave FD method was shown to be useful for the measurement of low-frequency density fluctuations, which are impossible to be measured by using a convention. Thomson scattering. The obtained dispersion relations will be useful information for plasma waves.

  • PDF