• 제목/요약/키워드: Low $O_2$ tension

검색결과 40건 처리시간 0.03초

고폐동맥압을 동반한 선천성 심기형 환자에서 술후 폐동맥압과 혼합정맥혈 산소분압의 변화에 관한 분석 (An analysis of change in pulmonary arterial pressure and mixed venous oxygen tension after correction of congenital heart disease associated with pulmonary hypertension)

  • 김기봉;김용진
    • Journal of Chest Surgery
    • /
    • 제22권6호
    • /
    • pp.894-900
    • /
    • 1989
  • It has been suggested that mixed venous $O_{2}$ tension is a predicor of cardiac output especially in a critically ill patient after an open heart surgery. From April 1988 through September 1989, we monitored mixed venous $O_{2}$ tension and pulmonary arterial pressure in 48 patients with acyanotic congenital heart disease at postoperative 1 hour, 6 hour, 12 hour, 24 hour, and 48 hour respectively. They were divided into Group I, with severe pulmoary hypertension, and Group II, without severe pulmonary hypertension. In Group I, mixed venous $O_{2}$ tension and cardiac index showed significant increase with time (p<0.05), but the ratio of pulmonary-aortic systolic pressure didn't show significant change. The increase was significant only 24 hour after operation, and so this low cardiac performance in early postoperative period should be considered when postoperative management is being planned in the risky patient. In Group II, all of the three variables didn't show any significant change with time. The correlation coefficient between mixed venous $O_{2}$ tension and cardiac index was significantly different from zero in both Group I (p<0.001) and group II (p<0.05) at each imeperiod, but the ratio of pulmonary-aortic systolic pressure didn't correlated well with the other 2 variables. Our study showed that serial determination of mixed venous $O_{2}$ tension in acyanotic congenital heart disease could be used as a guide in estimating the cardiac index postoperatively.

  • PDF

토끼의 뇌혈관 연축 모델에서 혈관확장제 및 혈관수축제에 대한 기저동맥의 감수성 변화 (Changes in Vascular Responses of Basilar Artery to Vasodilators and Vasoconstrictors in Experimental Vasospasm Model Rabbits)

  • 백선하;한대희
    • Journal of Korean Neurosurgical Society
    • /
    • 제29권4호
    • /
    • pp.451-460
    • /
    • 2000
  • Objective : This experiment is aimed at clarifying the characteristics of spasmodic basilar arteries in the rabbits of subarachnoid hemorrhage(SAH) with observation of vascular response to nitric oxide(NO) and endothelin-1. Material and Methods : Seventy-nine New Zealand white rabbits were divided into 4 groups : control(n=17), sham operation(n=13), postictal-2-day(n=25), and postictal-7-day group(n=24). Rabbits in the postictal-2-day group and postictal-7-day group underwent transfemoral vertebral angiography 2 days and 7 days after SAH respectively. A vascular ring of spasmodic basilar artery was harvested and suspended in organ chamber($37^{\circ}C$) to observe isometric tension changes in response to NO and endothelin-1 under both high(95% $O_2$/5% $CO_2$) and low(95% $N_2$/5% $CO_2$) $O_2$ tension. To investigate the vascular response to NO, acetylcholine from $10^{-7}M$ to $3{\times}10^{-4}M$ concentration was applied to basilar artery ring precontracted with histamine $10^{-6}-10^{-5}M$ in the organ chamber. The vascular response to endothelin-1 was observed by applying endothelin-1 from $10^{-11}M$ to $3{\times}10^{-8}M$ concentration into organ chamber. Results : Seven of 15 live rabbits which underwent angiography 2 days after SAH, were confirmed to develop vasospasm($64.3{\pm}11.2%$) whereas seven of 13 live rabbits which underwent angiography 7 days after SAH, were confirmed to develop vasospasm($64.9{\pm}10.9%$). In all groups, hypoxia significantly reduced the vascular relaxation of basilar arteries to NO. However, hypoxia made no influence on the vascular contraction of basilar arteries to endothelin-1 in all groups. In vascular relaxation of basilar arteries to NO under high $O_2$ tension between groups, the maximum relaxation of basilar arteries in the postictal-7-day group was significantly reduced compared to the postictal-2-day group. In vascular contraction of basilar arteries to endothelin-1 under high $O_2$ tension between groups, the maximum contraction of basilar arteries in the postictal-7-day group was significantly reduced compared to the postictal-2-day group. Conclusions : This experiment suggests that the characteristics of vascular response to NO and endothelin-1 in the spasmodic basilar arteries of rabbits observed 2 days after SAH is different from those observed 7 days after SAH.

  • PDF

반복 일축응력하의 알루미나 파괴거동에 미치는 압축응력의 영향 (The Effect of Compressive Stress on Fracture Response of Alumina under Uniaxial Stress Cycling)

  • 김기태;서정;백성기
    • 한국세라믹학회지
    • /
    • 제28권9호
    • /
    • pp.712-720
    • /
    • 1991
  • The effect of cyclic compressive stress on fracture responses of Al2O3 was investigated under uniaxial stress cycling. Experimental data were obtained for Al2O3 tension specimens under uniaxial tension-unloading and tension-compression cyclic loading conditions. To investigate the effect of compressive stress on the crack growth, theoretical results from the crack growth rate were compared with measured stress vs. failure relations. At low stress level in tension-compression cycling, residual tensile strains were also observed about failure time.

  • PDF

상온하 혈액희석 체외순환에 있어서 혈액 GAS 동태에 관한 실험적 연구 (Experimental Studies of the Blood Gas Transport during Normothermic Hemodilution Perfusion)

  • 박희철
    • Journal of Chest Surgery
    • /
    • 제13권2호
    • /
    • pp.85-91
    • /
    • 1980
  • Extracorporeal circulation by hemodilution technique has been currently used with its clinical safety and good peripheral tissue perfusion in open heart surgery. There is no doubt that $O_{2}$ carrying capacity of the blood is disturbed by decreased hemoglobin level resulting from hemodilution of the circulating blood. From the view point of the blood gas exchange, these experimental studies were undertaken to determined the sate limit of hemodilution in the condition of cardiopulmonary bypass with a constant perfusion flow rate. Twelve adult mongrel dogs weighing 10 to 13 Kg. were anesthetized with pentobarbital and then respiration was controlled with Harvard volume respirator using room air. The cardiopulmonary by pass was performed by use of Sarns heart lung machine (console 5000, 5 head and 2 roller pumps) and Travenol pediatric bubble oxygenator. The perfusion rate during bypass was maintained at a constant rate of 80 ml/min/Kg of body weight. The ratio of oxygen gas flow to blood flow was kept in 3 to 1 constantly. International hemodilution was attained by serial blood withdrawals and immediate infusion of equal volumes of diluants composed of Ringer's lactate, 5% dextrose in water and 25% mannitol solution, proportionally 60%, 30%, and 10%. Arterial and venous blood samples were obtained between 15 and 20 minutes following each hemodilution. Hematocrits and hemoglobin values, $PO_{2}$, $PCO_{2}$ and pH were measured. Oxygen and carbon dioxide contents oxygen consumption and carbon dioxide elimination were calculated groups according to different hematocrit values and the correlations were evaluated. Result were as follows. 1. the arterial $O_{2}$ tension and $O_{2}$ saturation were maintained at the physiological level irrespective of the hematocrit value. 2. The venous $O_{2}$ tension and $O_{2}$ saturation showed a tendency to decline with the decrease in hematocrit value and positive correlation between them (r = +0.49, r = +0.76), The mean values of venous $O_{2}$ tension and $O_{2}$ saturation, however, were not decreased when the hematocrit levels were lower than 20%. 3. The arterial $O_{2}$ content declined lineally in proportion to the fall of hematocrit level with a positive correlation between them (r = +0.95). 4. The venous $O_{2}$ contents were decreased gradually as the hematocrit value decreased with positive correlation between them ( r =+0.89). The trend of diminution of venous $O_{2}$ content, however, was became low according to progressive decrease of hematocrit level. 5. Systemic oxygen consumption was in higher range than $O_{2}$ requirement of basal metabolism when the hematocrit value was above 20%, but abruptly decreased when the hematocrit value became to below 20%. 6. The arterial $CO_{2}$ tension and $CO_{2}$ content showed trend of increasing with progressive decrease of hematocrit value but exhibited a rather broad range and there was no relationship between those value and the hematocrit value. 7. The venous $CO_{2}$ tension and $CO_{2}$ content have also no correlation with change of Ht. value but related directly to those value of arterial blood with positive correlation between them (r = +0.78, r = +0.95_. 8. A-V difference of $CO_{2}$ content and $CO_{2}$ elimination wasnot significantly influenced by Ht. value. From the results, we obtained that feasible limit in inteneional hemodilution is above the hematocrit value of 20% under the given experimental condition.

  • PDF

카올린-인산염-물계의 저온 특성에 관한 연구 (A Study on Low Temperature Properties of Kaolin-Phosphate-Water Systems)

  • 박금길;박근원
    • 한국세라믹학회지
    • /
    • 제18권3호
    • /
    • pp.192-200
    • /
    • 1981
  • This study deals with the low temperature ($25^{\circ}C$-$600^{\circ}C$) properties of Kaolin-Phosphate-water systems. Phosphoric acid, mono aluminum phosphate, mono ammonium phosphate, the mixture of phosphoric acid and mono aluminum phosphate, and the mixture of phosphoric acid and mono ammonium phosphate were used to characterize the M.O.R. of the systems with to quantity of phosphates, curing time, and firing temperature. Firing shrinkage, viscosity, surface tension, DTA, TGA, and X-ray diffraction patterns were also measured in order to investigated the factors of strengthening. The results of this study were summarized as follows: 1. The M.O.R. of kaolin-phosphate systems were stronger than that of Kaolin-water system at room temperature or low temperature($25^{\circ}C$-$600^{\circ}C$). Though it was increased according to the longer curing time, the higher temperature, and the more addition of phosphate, the M.O.R. were decreased in the case of 10 wt% phosphate addition in the system of phosphoric acid, mono aluminum phosphate and phosphoric acid-mono aluminum phosphate. 2. When the concentration of Phosphate was at 4 wt%, the M.O.R. of specimen cured at $25^{\circ}C$ and added to the phosphoric acid was strongest among the specimens in added to the others phosphates. Whereas, when the concentration of phosphate was above 6wt%, the M.O.R. of specimen cured at $25^{\circ}C$ and added to the phosphoric acid mono ammonium phosphate system cured at $25^{\circ}C$ was the strongest. 3. The M.O.R. of the specimen heated, in the temperature range of 15$0^{\circ}C$-1$600^{\circ}C$, and added to the mixture of phosphoric acid-mono aluminum phosphate system or phosphoric acid-mono ammonium phosphate system was stronger than that of specimen added to Phosphoric acid, mono-aluminum Phosphate or mono-ammonium phosphate alone. 4. The bonding force of phosphate binders was more closely related to surface tension than viscosity and it tended to be inversely proportional to surface tension. The bonding force after heating treatment seemed to be caused by the change of structure of phosphate according to heating.

  • PDF

응력비의 영향을 고려한 알루미늄합금 A5083-O의 피로균열전파 특성 예측모델 (A Model Estimating the Ratigue Crack Growth in Aluminum Alloy A5083-O Considering the Effect of Stress ratio)

  • 조상명;김종호;김영식
    • Journal of Welding and Joining
    • /
    • 제12권3호
    • /
    • pp.82-89
    • /
    • 1994
  • In this paper the effect of stress ratio on the fatigue crack growth rate of aluminum alloy A5083-O was examined. The fatigue tests were carried out using CCT (center cracked tension) specimens and CT(compact tension) specimens which were subjected to 0.5 and -1.0 stress ratio respectively. The obtained results are as follows; 1) The $\DeltaK_{th}$ as the function of stress ratio R was introduced in evaluating the fatigue crack growth rate of A5083-O. 2) A new model evaluating the effect of stress ratio on the fatigue crack growth rate was developed over the region of low and high propagation rate.

  • PDF

광릉 전나무인공림에서 수액이동량, 토양수분장력 그리고 토양함수량의 변화와 상호작용 (Interactions and Changes between Sapflow Flux, Soil Water Tension, and Soil Moisture Content at the Artificial Forest of Abies holophylla in Gwangneung, Gyeonggido)

  • 전재홍;김경하;유재윤;정용호;정창기
    • 한국산림과학회지
    • /
    • 제94권6호
    • /
    • pp.496-503
    • /
    • 2005
  • 본 연구는 2004년 9월에서 10월까지 경기도 광릉시험림내 국립산림과학원 산림수문 유역시험지인 전나무 인공림에서 수목의 증산에 의해 나타나는 수액이동량과 토양수분장력 및 토양함수율의 변화를 조사하고, 이들 간의 상호작용을 밝히기 위하여 수행되었다. 대상지인 전나무림은 1976년 조림지로서 1996년 2월부터 7월까지 1차 간벌과 가지치기를 실시하였으며 2004년 4월에 2차 간벌과 가지치기를 실시하였다. 수액이동량은 수액유속계로 측정하였으며, 토양수분장력은 사면부와 계류부에 텐시오미터를 설치하여 조사하였다. 토양함수량은 사면부에 10, 30, 50 cm 깊이로 TDR을 매설하여 관측하였으며, 각 조사항목들은 30분단위로 측정하여 데이터로거에 저장하였다. 조사기간 동안 일일 평균수액이동량은 10.16l이고, 최대는 15.09l, 최소는 0.01l였다. 시간별로는 9시부터 수액이동량이 증가하기 시작하여 13시에 최대치인 30분당 0.74l에 달하였으며, 15시까지 그 값이 유지된 후 급감하기 시작하여 19시를 지나면서 0으로 수렴하였고 야간에는 수액이동이 거의 없었다. 강우시에는 주간에도 수액이동량이 거의 없는 것으로 나타났다. 토양수분장력은 사면에서 평균 $-141.3cmH_2O$, $-52.9cmH_2O$, $-134.2cmH_2O$로 낮았으며, 계류부 사이의 완경사지에서 평균$-6.1cmH_2O$, $-18.0cmH_2O$ and $-3.7cmH_2O$로 높게 나타났다. 특히 토양수분에 대한 강우의 영향이 감소된 후 사면의 토양수분장력은 수목의 증산에 따라 일주기성을 나타내어 수액이동량이 증가하면 토양수분장력이 낮아지고 수액이동량이 감소하면 토양수분장력이 높아지는 경향을 보였으나, 계류부에서는 수액이동량의 영향을 파악할 수 없었다. 토양함수율은 강수 종료 후 지속적으로 감소하였으며, 사면부의 토양수분장력과 같이 증산에 따른 일주기성을 나타내어 주간에는 토양함수율이 감소하였고 수액의 이동이 거의 없는 야간에는 함수율이 유지되거나 또는 소폭 상승하는 경향이 나타났다. 이상의 결과로 수액이동량의 변화에 따른 토양수분의 변화는 사면부와 계류부에서 다르게 나타나는 것을 알 수 있었다.

PIC 방법으로 제조된 저점도 W/O 나노에멀젼의 안정성 (Stability of W/O Nanoemulsions with Low Viscosity Prepared by PIC Method)

  • 조완구
    • 대한화장품학회지
    • /
    • 제42권2호
    • /
    • pp.127-133
    • /
    • 2016
  • 본 연구에서는 정제수/Span 80-Nikkol BL 25/오일계의 water-in-oil (W/O) 나노에멀젼을 높은 온도에서 PIC 유화로 제조하였다. 이 방법은 본 시스템에서 미세하게 분산된 저점도의 W/O 나노에멀젼의 형성을 가능케 하였다. 그러나 실온에서 PIC 방법으로 제조된 에멀젼은 나노에멀젼보다는 마크로에멀젼이 제조되었다. 유화온도가 $30^{\circ}C$에서 $80^{\circ}C$로 증가하면 온도에 따른 계면장력의 큰 변화의 결과로 입자 크기는 $2{\mu}m$에서 100 nm 정도로 감소하였다. $80^{\circ}C$에서 제조된 나노에멀젼의 입자 크기는 50 ~ 200 nm 범위에 있었고 내상의 분율은 15 wt%까지 가능하였다. 또한 혼합 유화제의 최적 HLB는 7.0 부근에서 가장 안정한 나노에멀젼이 형성되었다. 제조된 나노에멀젼은 1개월 이상 실온에서 안정하였다. 본 연구 결과는 저점도의 W/O 나노에멀젼의 형성 최적화에 중요한 정보를 제공할 수 있다. 이 결과는 W/O 나노에멀젼의 저점도로 인한 부드러운 사용감 등으로 화장품 제형으로 유용하게 이용될 것으로 생각된다.

중금속 창연산화납계 저온유리 분말을 이용한 세라믹스/금속의 접합거동 (Joining Behavior of Ceramics to Metal by Using Lead-bismate Heavy Metal Glass Frit)

  • 최진삼
    • 한국세라믹학회지
    • /
    • 제51권4호
    • /
    • pp.312-316
    • /
    • 2014
  • The joining behavior of forsterite ceramics to SUS304 alloy using $8PbO-78Bi_2O_3-8B_2O_3-4ZnO-2SiO_2$ (wt%) system glass frit was investigated. The contact angle was smaller than $90^{\circ}$ at a temperature of $460^{\circ}C$. Redox reaction at the interface between forsterite and SUS304 was found to appear when the electrons in the metal part moved toward the glass part and the oxygen ions in glass moved to the metal side. The decrease of the surface tension due to the PbO solubility on the forsterite side contributed to the better wetting behavior at low temperature.

Yield strength estimation of X65 and X70 steel pipe with relatively low t/D ratio

  • Kim, Jungho;Kang, Soo-Chang;Kim, Jin-Kook;Song, Junho
    • Steel and Composite Structures
    • /
    • 제38권2호
    • /
    • pp.151-164
    • /
    • 2021
  • During the pipe forming process, a steel plate undergoes inelastic behavior multiple times under a load condition repeating tension and compression in the circumferential direction. It derives local reduction or increase of yield strength within the thickness of steel pipes by the plastic hardening and Bauschinger effect. In this study, a combined hardening model is proposed to effectively predict variations of yield strength in the circumferential direction of API-X65 and X70 steel pipes with relatively low t/D ratio during the forming process, which is expected to experience accumulated plastic strain of 2~3%, the typical Lüder band range in a low-carbon steel. Cyclic tensile tests of API-X65 and X70 steels were performed, and the parameters of the proposed model for the steels were calibrated using the test results. Bending-flattening tests to simulate repeated tension and compression during pipe forming were followed for API-X65 and X70 steels, and the results were compared with those by the proposed model and Zou et al. (2016), in order to verify the process of material model calibration based on tension-compression cyclic test, and the accuracy of the proposed model. Finally, parametric analysis for the yield strength of the steel plate in the circumferential direction of UOE pipe was conducted to investigate the effects of t/D and expansion ratios after O-forming on the yield strength. The results confirmed that the model by Zou et al. (2016) underestimated the yield strength of steel pipe with relatively low t/D ratio, and the parametric analysis showed that the t/D and expansion ratio have a significant impact on the strength of steel pipe.