• Title/Summary/Keyword: Loss Separation Method

Search Result 105, Processing Time 0.025 seconds

The Coexistence of OFDM-Based Systems Beyond 3G with Fixed Service Microwave Systems

  • Jo Han-Shin;Yoon Hyun-Goo;Lim Jae-Woo;Chung Woo-Ghee;Yook Jong-Gwan;Park Han-Kyu
    • Journal of Communications and Networks
    • /
    • v.8 no.2
    • /
    • pp.187-193
    • /
    • 2006
  • In this paper, we study the coexistence of orthogonal frequency division multiplexing (OFDM)-based systems beyond 3G (B3G) and point-to-point (P-P) fixed service (FS) microwave systems. The advanced general analytical model derived via a power spectral density (PSD) analysis proposed in this paper has two advantages in comparison with the conventional minimum coupling loss (MCL) method. First, the interfering signal power that appears in the band of a victim system can be easily assessed without a spectrum emission mask. Second, when transmit power is not allocated to some subcarriers overlapping the band of the victim system in order to mitigate B3G OFDM-based systems interference with other systems, the general analytical model can successfully assess the interference from the B3G systems into FS systems, whereas the MCL method incorporating the spectrum emission mask cannot be applied in the presence of the same interference condition. The proposed model can be derived in a closed form and is simply implemented with the help of simulation, and thus the solution can be obtained in significantly reduced time. Through application of the proposed model, coexistence results are analyzed in a co-channel and adjacent channel with respect to guard band and minimum separation distance.

Fusion technology of artifacts considering environmental recycling for sustainability

  • Fujita Toyohisa
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2003.11a
    • /
    • pp.563-568
    • /
    • 2003
  • Recently, the recycled amount of electric, mechanical parts, and appliances in artifacts has increased. These products use valuable rare metals such as platinum group metals and gold, which are included occasionally as additives. Rare metals are maldistributed in the world and most of them are produced in small quantities. A small amount of rare metals used in the appliances causes a large loss of rare metal resources because of the lack of an economically recycling method. The present recycling technologies including physical and chemical separation methods that are considered for recycling of electric, mechanical parts and appliances.

  • PDF

Study on Compatibility between WPT Device at ISM band and Radio Modem (ISM 대역의 WPT 기기와 무선 모뎀의 공존 방안 연구)

  • Kim, SeungNam;Lee, Ilkyoo;Min, Kyoungil
    • Journal of Satellite, Information and Communications
    • /
    • v.9 no.4
    • /
    • pp.47-52
    • /
    • 2014
  • Recently, the interest of Wireless Power Transmission(WPT) has been increased for Mobile device application. It is necessary to analyze interference between wireless devices for the efficient use of frequency resource. The Minimum Coupling Loss(MCL) method and the Monte Carlo(MC) method were used for the interference analysis. In this paper, the impact of the 3rd order harmonics of the wireless charger for Cellular Phone on the existing Radio Modem was analyzed. As a result, the separation distance and the allowable number of interferer on the basis of service radius were obtained to protect the Radio Modem from the wireless charger for Cellular Phone.

Preparation of Molecularly Imprinted Poly(methacrylic acid) and Its HPLC Separation Characteristics of Retinoids (분자각인 Poly(methacrylic acid)의 제조 및 레티노이드 화합물의 HPLC 분리 특성)

  • 남기훈;권영돈;김덕준
    • Polymer(Korea)
    • /
    • v.26 no.6
    • /
    • pp.710-717
    • /
    • 2002
  • Molecularly imprinted polymers were prepared in particle forms by crosslinking methacrylic acid (MAA)) using all trans-retinoic acid as a template. The HPLC column packed with the prepared molecular imprinted polymers showed high capability in separation of retinoid derivatives. The column capacity factor and selectivity increased with increasing MAA to template ratio when the incorporated template amount was fixed, as it statistically generated more binding sites between host molecules and template. Molecularly imprinted polymer particles prepared via an emulsion polymerization method were round-shaped and their sizes were more uniformly distributed, but their separation capability was inferior to those obtained by solution polymerization method. It was presumably because the loss of interaction strength between MAA and the template due to hydrogen bonding either between MAA and water or between template and water during the synthesis of molecularly imprinted polymers.

Microbial Transglutaminase의 비연속 분리공정 최적화

  • U, Dong-Jin;An, Yong-Seon;Sin, Won-Seon;Jeong, Yong-Seop;U, Geon-Jo
    • 한국생물공학회:학술대회논문집
    • /
    • 2000.11a
    • /
    • pp.260-263
    • /
    • 2000
  • Membranes are widely used to separate target solute molecules such as proteins on the basis of their size in cell broth mixture to minimize the loss of target compounds. In this study, membrane separation system using ultrafilters of MWCO 100 K and 50 K, was operated for concentration and purification of microbial transglutaminase. Fermentation broth containing MTGase was prefiltered by using pore size 1.6 and $0.7\;{\mu}m$ pre-filter made of cellulose fiber and $0.45\;{\mu}m$ microfilter made of cellulose acetate. The prefiltered solution was concentrated by 100 K and 50 K ultrafilter. The final enzyme concentration was 1.29 units/ml and enzyme specific activity was 0.2 units/mg protein. This specific activity were 3.7 times higher than that of initial cell broth mixture. Membrane separation process of microfiltration and ultrafiltration was proved to be very economic, energy efficient and effective separation method used to concentrate MTGase.

  • PDF

Optimization of an Annular Fin with a Pipe of Variable Inner Radius for Fixed Fin Volume (고정된 휜 체적에 기준한 원관 내부반경이 변하는 환형 휜의 최적화)

  • Kang, Hyung-Suk
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.3
    • /
    • pp.229-235
    • /
    • 2010
  • Optimum values of fin performance and dimensions for an annular fin with a rectangular profile and a pipe with variable inner radius are determined by using a variable separation method. The range of ambient convection characteristic number that results in optimum heat loss is listed. The optimum heat loss, corresponding optimum fin effectiveness, fin length, and fin height are presented as a function of the inner radius of the pipe, inner fluid convection characteristic number, fin volume, and ambient convection characteristic number. One of the results shows that the optimum heat loss, fin effectiveness and fin length increase linearly with the inner radius of the pipe when both the fin volume and fin-base radius are fixed.

Optimization of an Annular Fin with Variable Pipe Inside Radius in the Heat Exchanger of Ground Source System (지열시스템의 열교환기에서 원 관 내부 반경이 변하는 환형 핀의 최적화)

  • Kang, Hyung-Suk
    • New & Renewable Energy
    • /
    • v.5 no.1
    • /
    • pp.40-46
    • /
    • 2009
  • Optimization of a rectangular profile annular fin with variable pipe inside radius is presented. This optimum procedure is based on fixed fin height and is made by using variables separation method. The optimum heat loss, corresponding optimum fin length and optimum fin efficiency are presented as a function of pipe inside radius, fin half height, inside fluid convection characteristic number and ambient convection characteristic number. One of results shows that the optimum fin length increases linearly with increase of pipe inside radius for fixed fin height and fin base radius.

  • PDF

2-Dimensional Performance Analysis of a Plate Fin (평판-핀의 2차원 성능 해석)

  • Kim, Yun-Ha;Kang, Hyung-Suk
    • Journal of Industrial Technology
    • /
    • v.20 no.B
    • /
    • pp.21-26
    • /
    • 2000
  • Heat loss, fin effectiveness and efficiency of a plate fin are investigated as a function of non-dimensional fin length and Biot number using a two-dimensional separation of variables method. The value of temperature of the left side is set to be different from that of the right side for this plate fin to satisfy the real physical condition. Also temperature distribution within this plate fin is listed. One of the results shows that the fin can be considered to be useful in view of fin effectiveness on the given range of Biot number when non-dimensional fin length is larger than 3.

  • PDF

Analysis of a Modified Plate Fin for Enhanced Performance of a Plate Fin Heat Exchanger (평판 핀 열교환기의 성능 향상을 위한 변형된 평판 핀에 대한 해석)

  • 김윤하;강형석
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.9 no.3
    • /
    • pp.84-91
    • /
    • 2001
  • Comparison between performance of a plate fin and that of a modified plate fin is investigated as a function of the position, the non-dimensional width and height of wings as well as the non-dimensional fin length using a two-dimensional separation of variables method. The ratio of the incremental rate of heat loss to that of the area of a modified plate fin is also presented as a function of the height of wings. The modified plate fin is made by attaching the wings to upper and lower sides of a plate fin. One of the results shows that performance of a modified plate fin is more improved as the wings approach left (higher) thermal reservoir.

  • PDF

Treatment of the cemental tear

  • Park, Ye-Sol;Lee, Jae-Hong;Jeong, Seong-Nyum
    • Oral Biology Research
    • /
    • v.42 no.4
    • /
    • pp.248-253
    • /
    • 2018
  • Cemental tears are uncommon form of root fracture that can lead to rapid localized periodontal attachment loss. Studies have described periodontal breakdown as being associated with the separation of the cementum from the underlying tooth structure. The aim of this case report is to assess the outcome of treatment of cemental tear with several surgical treatment regimens. Three patients with cemental tear were treated with different surgical method. In all three cases, the cemental tear occurred on maxillary right central incisors. In each case, the root fragment were removed, the localized defect was treated using different surgical methods including guided tissue regeneration and bone graft followed by scaling and root planting. In all three cases, symptoms subsided after the treatment and clinical attachment level was improved up to 2 mm at 3 month after surgery. Both conventional and regenerative periodontal surgery could achieve successful outcomes.