• Title/Summary/Keyword: Loop-storage

Search Result 122, Processing Time 0.024 seconds

A Strategy for Balanced Power Regulation of Energy Storage Systems in a Distribution System during Closed-Loop Operation

  • Han, Yoon-Tak;Oh, Joon-Seok;Cha, Jae-Hun;An, Jae-Yun;Hyun, Seung-Yoon;Lee, Jong-Kwan;Seo, In-Yong;Kim, Jae-Eon
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.6
    • /
    • pp.2208-2218
    • /
    • 2017
  • To resolve overload in a distribution system, a distribution system operator (DSO) often performs a load transfer using normally open tie points and switches in the distribution line. During this process, the distribution system is momentarily operated in closed-loop operation. A closed-loop current in the distribution system can cause a power failure due to excess breaking current in the circuit breakers and reclosers. Therefore, it is necessary to calculate the closed-loop current exactly. However, if there are a large number of distributed generation (DG) systems in the distribution system, such as energy storage systems (ESS), they might obstruct the closed-loop operation based on bidirectional power flow. For quick and precise operation of a closed-loop system, the ESS has to regulate the power generation while satisfying closed-loop operation in the worst cases. We propose a strategy for balanced power regulation of an ESS. Simulations were carried out using PSCAD/EMTDC, and the results were compared with calculation results.

Islanded Microgrid Simulation using Hardware-in-the Loop Simulation (HILS) System based on OPAL-RT (OPAL-RT 기반의 Hardware-in-the-Loop Simulation (HILS) 시스템을 이용한 독립운전모드 마이크로그리드 시뮬레이션)

  • Yoo, Hyeong-Jun;Kim, Hak-Man
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.4
    • /
    • pp.566-572
    • /
    • 2013
  • A microgrid is a small scale power system. The microgrid is operated in two operation modes, the grid-connected mode and the islanded mode. In the islanded mode, the frequency of a microgrid should be maintained constantly. For this, the balance between power supply and power demand during islanded mode should be met. In general, energy storage systems (ESSs) are used to solve power imbalance. In this paper, the frequency control effect of a Lithium-ion battery energy storage system (Li-ion BESS) has been tested on the hardware-in-the loop simulation (HILS) system environment.

Cooling and Heating Energy Performance and Cost Analysis of Vertical Closed-loop Geothermal Heat Pump Coupled with Heat Storage Tank Compared to Conventional HVAC System (일반공조 시스템 대비 축열조와 연동된 수직밀폐형 지열히트펌프의 냉난방 에너지 성능 및 경제성 분석)

  • Kim, Min-Ji;Do, Sung-Lok;Choi, Jong-Min;Lee, Kwang Ho
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.11
    • /
    • pp.81-87
    • /
    • 2018
  • Among various types of geothermal heat pump systems, Vertical Closed-Loop Geothermal Heat Pump (VGSHP) has received increasing attention due to a variety of advantages such as the potential to be installed in a relatively small space and improved energy efficiency. In this research, the performance of VGSHP system coupled with heat storage tank was evaluated, by analyzing operational behavior of heat storage tank, the variations of heat pump energy performance due to the connection with heat storage tank, part load ratios characteristics of heat pump and the corresponding energy cost, compared to chiller and boiler based conventional system. The results of this study showed that the VGSHP system coupled with heat storage tank showed an energy saving effect of about 18% for cooling and about 73% for heating, and annual heating/cooling energy cost reduction of 43,000,000 KRW ($ 39,000), compared to the conventional air conditioning system. In addition, after considering both energy cost and initial investment cost including equipment, installation and auxiliary device expenses, payback period of approximately 11.8 years was required.

Always Metastable State True Random Number Generator

  • Seo, Hwa-Jeong;Kim, Ho-Won
    • Journal of information and communication convergence engineering
    • /
    • v.10 no.3
    • /
    • pp.253-257
    • /
    • 2012
  • This paper presents an efficient filtering system for a metastable state-based true random number generator. To output a result with high randomness, we use loop-storage for storing the value of metastability. During the metastable state, the output value is accumulated to the storage. When the non-metastable state arises, the stored metastable value will be used for output instead of the result of the non-metastable state. As a result, we can maintain high entropy together with the original throughput.

Disturbance estimation of optical disc by closed loop output estimator (페루프 외란 검출기를 통한 광디스크 외란 측정)

  • Park, Jin-Young;Chun, Chan-Ho;Jun, Hong-Gul;Lee, Moon-Noh;Hyunseok Yang;Park, Young-Pil
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11b
    • /
    • pp.1166-1171
    • /
    • 2001
  • The method for output disturbance estimation is proposed. In this method, output disturbance is estimated from the closed loop system dynamics using the output and control input signals. In the closed-loop output-disturbance estimator, precise system identification is required to reduce estimation error. The realization of estimator was done by the DSP board (DSPl103), and disturbance estimation in various environments was performed: change of rotation speed, media feature and spindle motor with (or without) auto-ball balancing system (ABS). From these experiments, the disturbance characteristics of ODD under various conditions are analyzed, and the desirable servo loop configuration based these results is proposed.

  • PDF

Implementation of Two TMS320F28335 based BESS Controllers for Microgrid and Control Performance Test in the Hardware-in-the-Loop Simulation System (마이크로그리드용 2기의 TMS320F28335 기반 BESS 제어기 구현 및 Hardware-in-the-Loop Simulation 시스템을 이용한 제어 성능 테스트)

  • Kim, Nam-Dae;Yoo, Hyeong-Jun;Kim, Hak-Man
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.4
    • /
    • pp.559-564
    • /
    • 2014
  • A microgrid as a small scale power system is operated by the grid-connected mode and islanded mode. It is anticipated that the battery energy storage system (BESS) is able to be applied to the microgrid for stable power control, such as tie-line and smoothing control in the grid-connected mode and voltage and frequency control in the islanded mode. In this paper, a digital signal processor (DSP), Two BESS controllers based on TMS320F28335 of a microgrid are implemented and are tested to show control performance in the hardware-in-the loop simulation (HILS) system.

Design of Disturbance Observer Using Robust Control Method for SPM-based Data Storage Systems (SPM-based Data Storage 시스템을 위한 강인 제어 시스템 설계 방식을 이용한 외란 관측 제어기 설계)

  • Moon, Jun;Lee, Choong-Woo;Chung, Chung-Choo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.1
    • /
    • pp.160-167
    • /
    • 2009
  • In this paper, we apply the robust disturbance observer (DOB) to a SPM-based data storage (SDS) system. In the SDS system, coupling dynamics and parameter uncertainties are obstacles to the precision tracking control. Although the DOB is known to be an effective method to reject disturbances, there has been no systematic design approach to how to design DOB parameters. In this paper, the robust DOB is formulated based on the robust stabilization of normalized coprime factor plant description and the $H{\infty}$ loop shaping method. From the simulation and experimental results. the improved robustness and performance are obtained by the proposed robust DOB.

Design of type 316L stainless steel 700 ℃ high-temperature piping

  • Hyeong-Yeon Lee;Hyeonil Kim;Jaehyuk Eoh
    • Nuclear Engineering and Technology
    • /
    • v.55 no.10
    • /
    • pp.3581-3590
    • /
    • 2023
  • High-temperature design evaluations were conducted on Type 316L stainless steel piping for a 700 ℃ large-capacity thermal energy storage verification test loop (TESET) under construction at KAERI. The hot leg piping with sodium coolant at 700 ℃ connects the main components of the loop heater, hot storage tank, and air-to-sodium heat exchanger. Currently, the design rules of ASME B31.1 and RCC-MRx provide design procedures for high-temperature piping in the creep range for Type 316L stainless steel. However, the design material properties around 700 ℃ are not available in those rules. Therefore, a number of material tests, including creep tests at various temperatures, were conducted to determine the insufficient material properties and relevant design coefficients so that high-temperature design on the 700 ℃ piping may be possible. It was shown that Type 316L stainless steel can be used in a 700 ℃ high-temperature piping system of Generation IV reactor systems or a renewable energy systems, such as thermal energy storage systems, for a limited operation time.

A Study on the Thermal Characteristics of Cheju Seasonal Installation (제주 태양열 계간 축열단지의 열적 특성에 관한 연구)

  • Han, Yu-Ri;Park, Youn-Cheol;Chun, Won-Gee;Kang, Yong-Heack;Lee, Sang-Nam
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.563-566
    • /
    • 2006
  • An investigation has been carried for the thermal characteristics of the seasonal storage installation in Cheju. It features the solar collector area of $340m^2$ and the storage capacity of $600m^3$. Four different types of solar collector systems are compared for their performance of collecting solar energy throughout the year. Of these, two are made of tubular shaped vacuum collectors and the others are flat plate collectors. Results indicate that each system could play an important role in exploiting solar energy depending on the temperature range in its operation. Especially, the vacuum collectors outperformed the others when the inlet temperatures of the collector loop were raised beyond $40m^2$. This became more conspicuous as the return temperatures from the storage tank rose reflecting the seasonal variation. Due to the large heat capacity of the storage tank, temperature changes were rather small compared to those in the collecting loop regardless of seasonal fluctuations.

  • PDF

Stability Control of Energy Storage Voltage Source Inverters in Isolated Power Systems

  • Hu, Jian;Fu, Lijun
    • Journal of Power Electronics
    • /
    • v.18 no.6
    • /
    • pp.1844-1854
    • /
    • 2018
  • Isolated power systems (IPS) are often characterized by a weak grid due to small power grids. The grid side voltage is no longer equivalent to an ideal voltage source of an infinitely big power grid. The conversion control of new energy sources, parameter perturbations as well as the load itself can easily cause the system voltage to oscillate or to become unstable. To solve this problem, increasing the energy-storage power sources is usually used to improve the reliability of a system. In order to provide support for the voltage, the energy-storage power source inverter needs an method to control the voltage source. Therefore, this paper has proposed the active damping control of a voltage source inverter (VSI) based on virtual compensation. By simplifying the VSI double closed-loop control, two feedback compensation channels have been constructed to reduce the VSI output impedance without changing the characteristics of the voltage gain of a system. This improvement allows systems to operate stably in a larger range. A frequency-domain analysis, and simulation and experimental results demonstrate the feasibility and effectiveness of the proposed method.