• Title/Summary/Keyword: Loop-shaping

Search Result 124, Processing Time 0.03 seconds

Automatic Blood Pressure Control Using PI Controller with $H_{\infty}$ Loop-Shaping

  • Han, Jeong-Yup;Lee, Sang-Kyung;Park, Hong-Bae
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.326-329
    • /
    • 2004
  • In this paper, we show a new form of blood pressure controller combined PI control with $H_{\infty}$ loop-shaping. Hypertensive patients or post-operative patients need to maintain normally blood pressure. Exact regulation of blood pressure is needed for maintaining variable blood pressure of preventing complications. The regulation of blood pressure is achieved by injecting drugs, and usually sodium nitroprusside is used as those kinds of drugs. It is necessary to control the infusion rate sodium-nitroprusside carefully to achieve the desired blood pressure. It has been known that regulation of blood pressure by automatic controller is more effective than regulation of blood pressure by human operators. The control of blood pressure has many constraints and uncertainties. Most of biological system has the time-varying variables and the side effects such as increased risk of sepsis and organ failure. To solve such a problem, we design a new robust PI controller using $H_{\infty}$ loop-shaping to decrease noise effects that come out from human body and errors for time delay. The system with designed controller shows more stable control of mean blood pressure and more robust performance for uncertainties. Validation methods for the control performance are confirmed to computer simulations.

  • PDF

Analysis of robust performance improvement using loop shaping and structured singular value (루프쉐이핑과 구조적 특이치를 이용한 견실성능 개선)

  • 방경호;오도창;박홍배
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.33B no.5
    • /
    • pp.17-24
    • /
    • 1996
  • In this paper, we present a robust performance improvement method for the NLCF(normalized left coprime factor) uncertain structure using loop shaping and the structure singular value. For this, we select weighting functions for a loop shaping considering condition numer, and transform the NLCF uncertain structure into the 4-block structure. However, we can't get a good performance on account of the restriction of weighting functions. To cope with this, we motivate the use of structured singular vlaue in the robust performance improvement procedure. After all, the robust performance improvement can be obtained by a factor W$_{a}$ and a scaling factor of D-K iteration.

  • PDF

Residual Vibration Control of Robot with Flexible Joints Using Input Shaping (입력 다듬기기법을 이용한 유연관절을 갖는 로봇의 잔류진동 제거)

  • 박주이;장평훈
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.11
    • /
    • pp.3066-3074
    • /
    • 1994
  • This paper addresses the residual vibration problem of robots due to joint flexibility excited by fast accelerations, which has not been easily solved with conventional closed loop controllers. In this paper, an open loop input shaping technique, proposed by singer, has been applied to a 3 DOF robot with joint flexibility. In conjunction to the technique, a closed loop controller based on time-delay controller was also used. The results of simulations and experiments showed that the technique is quite effective for suppressing the residual vibration.

Design of the Anti-windup and Bumpless Transfer Controller with Application to Nonlinear Boiler Systems (누적방지 무충돌 전환 제어기의 설계와 비선형 보일러 시스템 적용)

  • Lee, Young-Sam;Lee, Myung-Eui;Kwon, Oh-Kyu
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.6 no.4
    • /
    • pp.247-253
    • /
    • 2000
  • In this paper, we deal with the full range control problem of nonlinear boiler systems subject to complex actuator constraints. Firstly, $H\infty$ loop shaping design procedure[10] is used for the controller design. Secondly, modified high-gain feedback[11] for the loop shaping controller is adopted for the anti-windup function and the bumpless transfer technique between controllers is proposed for the full range control of nonlinear systems. Finally, the performance of the proposed controller is demonstrated through the simulation studies.

  • PDF

An anti-swing control for 2 axis overhead cranes (2축 천정 크레인의 무진동 제어)

  • 이호훈;조성근;정연우
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.1428-1431
    • /
    • 1996
  • This paper proposes an anti-swing control law for a 2 degrees of freedom overhead crane. The dynamic model of a 2 degrees of freedom crane is highly nonlinear and coupled. The model is linearized and decoupled for each degree of freedom of the crane for small motions of the load about the vertical. Then a decoupled anti-swing control law is designed for each degree of freedom of the crane based on the linearized model. The control law consists of a position control loop and an swing angle control loop. The position loop,. is designed based on the loop shaping method and the swing angle loop is designed via the root locus method. Finally, the proposed anti-swing control law is implemented and evaluated on a 2 degrees of freedom prototype crane.

  • PDF

Design and Performance Analysis of a Noncoherent Code Tracking Loop for 3GPP MODEM (3GPP 모뎀용 동기 추적회로의 설계 및 성능 분석)

  • 양연실;박형래
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.28 no.12A
    • /
    • pp.983-990
    • /
    • 2003
  • In this paper, a noncoherent code tracking loop is designed for 3GPP MODEM and its performance is analyzed in terms of steady-state jitter variance and transient response characteristics. An analytical closed-form formula for steady-state jitter variance is Int derived for AWGN environments as a general function of a pulse-shaping filter, timing offset, signal-to-interference ratio, and loop bandwidth, together with the analysis on the transient response characteristic of a tracking loop. Based on the analysis, the code tracking loop with variable loop bandwidth that is efficient for full digital H/W implementation is designed and its performance is compared with that of the code tracking loop with fixed loop bandwidth, along with the verification by computer simulations.

A Study on Power System Stability Enhancement by Robust Control of SPFC and Generators

  • Lee, Byung-Ha
    • KIEE International Transactions on Power Engineering
    • /
    • v.4A no.3
    • /
    • pp.109-114
    • /
    • 2004
  • In this paper, the H$\infty$ control method is applied in the control of SPFC and generators in order to obtain the robust stability performance of the power system. Moreover, a SPFC H$\infty$ controller based on loop shaping is designed to achieve first-rate tracking properties in addition to the robust stability. This robust control method is applied to a Ward and Hale 6-bus power system and the effects are analyzed. The MATLAB program is used for simulation of the robust controller.

Robust Control of Induction Motor with HTheory based on Loopshaping

  • Benderradji, Hadda;Chrifi-Alaoui, Larbi;Mahieddine-Mahmoud, Sofiane;Makouf, Abdessalam
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.2
    • /
    • pp.226-232
    • /
    • 2011
  • The $H_{\infty}$ approach, adopted in this paper, is based on loop shaping using a normalized coprime factor combined with a field-oriented control to control induction motor. We develop two loops. The first one, the inner loop, controls the stator current by $H{\infty}$ controller in order to obtain good performance. The second loop, the outer one, guarantees stability and tracking performance of speed and rotor flux using a proportional integral controller. When the rotor flux cannot be measured, we introduce a flux observer to estimate the rotor flux. Simulation and experimental results are presented to validate the effectiveness and the good performance of this control technique.