• Title/Summary/Keyword: Loop size

Search Result 461, Processing Time 0.029 seconds

High-$T_c$ 2nd-order SQUID Gradiometer for Use in Unshielded Environments (비차폐 환경에서의 고온초전도 SQUID 2차 미분기의 특성연구)

  • 박승문;강찬석;이순걸;유권규;김인선;박용기
    • Progress in Superconductivity
    • /
    • v.5 no.1
    • /
    • pp.50-54
    • /
    • 2003
  • We have fabricated $∂^2$$B_{z}$ /$∂x^2$ type planar gradiometers and studied their properties in operation under various field conditions. $YBa_2$$Cu_3$$O_{7}$ film was deposited on $SrTiO_3$ (100) substrate by a pulsed laser deposition (PLD) system and patterned into a device by the photolithography with ion milling technique. The device consists of 3 pickup loops designed symmetrically Inner dimension and the width of the square side loops are 3.6 mm and 1.2 mm, respectively, and the corresponding dimensions of the center loop are 2.0 mm and 1.13 mm. The length of baseline gradiometer is 5.8 mm. Step-edge junction width is 3.0 $\mu\textrm{m}$ and the hole size of the SQUID loop is 3 $\mu\textrm{m}$ ${\times}$ 52 $\mu\textrm{m}$. The SQUID inductance is estimated to be 35 pH. The device was formed on a 20 mm ${\times}$ 10 mm substrate. We have tested the behavior of the device in various field conditions. The unshielded gradiometer was stable under extremely hostile conditions on a laboratory bench. Noise level 0.45 pT/$\textrm{cm}^2$/(equation omitted)Hz and 0.84 pT/$\textrm{cm}^2$/(equation omitted)Hz at 1 Hz for the shielded and the unshielded cases, which correspond to equivalent field noises of 150 fT/(equation omitted)Hz and 280 fT/(equation omitted)Hz, respectively. In spite of the short baseline of 5.8 mm, the high common-mode-rejection-ratio of the gradiometer, $10^3$, allowed us to successfully record magnetocardiogram of a human subject, which demonstrates the feasibility of the design in biomagnetic studies.

  • PDF

Bile Duct Ligation and Insulin-like Growth Factor-I on the Ischemia-Reperfusion Injury of the Small Bowel (쥐에서 허혈-재관류 소장 손상에 대한 담관결찰 및 Insulin-like Growth Factor-I의 영향)

  • Cha, Je-Sun;Lee, Myung-Duk
    • Advances in pediatric surgery
    • /
    • v.3 no.2
    • /
    • pp.98-107
    • /
    • 1997
  • To determine whether bile juice exclusion can prevent the mucosal damage, and Insulin-like growth factor-I can promote mucosal regeneration in ischemia-reperfusion injury of the bowel, 39 weanling rats with 10 cm of Thiry-Vella loop were studied. Animal groups were; Control, BL(common bile duct ligation), IGF{insulin-like growth factor-I(IGF-I) infusion} and IGF-BL(combined treatment). IGF-I(1.5 mg/kg/day) was continuously delivered through a subcutaneously implanted miniosmotic pump. After 15 minutes of superior mesenteric artery clamping, a tissue specimen(P) was taken after 30 minutes of reperfusion. Intestinal continuity was restored to allow oral feeding. A specimen of main tract(M) and another of the Thiry-Vella loop(T) were collected for histomorphometry after 48 hours of reperfusion and free feeding. Villus size ratio(VSR), crypt depth(CD), crypt-depth/villus-height ratio(CVR) and injury score(IS) were measured in 15 consecutive villi. The postoperative mortalities of bile duct ligation groups(BL and IGF-BL) were higher than those of other groups. In control group, VSR of M was lower(P<0.05) than P or T, but not in the other groups. VSR of M in control was lower than those in other groups. CD of T in control, IGF and IGF-BL group were higher than those of M. CD of M and T showed gradual increments from control, IGF and IGF-BL group, respectively. CVR of M and T in IGF group were higher than those in control. CVR in IGF-BL group, T was higher than M, and M was higher than P. About IS, M of BL($20.1{\pm}2.5$) and IGF-BL($20.9{\pm}3.3$) groups were significantly lower than that of control($32.4{\pm}2.5$). These results suggest that the exclusion of bile juice reduces the severity of the reperfusion injury of the mucosa, by inability to activate pancreatic enzymes and IGF-I stimulates mucosal regeneration in injured bowel, and the effect is potentiated by bile juice exclusion.

  • PDF

Noise Characteristics of 64-channel 2nd-order DROS Gradiometer System inside a Poorly Magnetically-shielded Room (저성능 자기차폐실에서 64채널 DROS 2차 미분계 시스템의 잡음 특성)

  • Kim, J.M.;Lee, Y.H.;Yu, K.K.;Kim, K.;Kwon, H.;Park, Y.K.;Sasada, Ichiro
    • Progress in Superconductivity
    • /
    • v.8 no.1
    • /
    • pp.33-39
    • /
    • 2006
  • We have developed a second-order double relaxation oscillation SQUID(DROS) gradiometer with a baseline of 35 mm, and constructed a poorly magnetically-shielded room(MSR) with an aluminum layer and permalloy layers for magnetocardiography(MCG). The 2nd-order DROS gradiometer has a noise level of 20 $fT/{\surd}Hz$ at 1 Hz and 8 $fT/{\surd}Hz$ at 200 Hz inside the heavily-shielded MSR with a shielding factor of $10^3$ at 1 Hz and $10^4-10^5$ at 100 Hz. The poorly-shielded MSR, built of a 12-mm-thick aluminum layer and 4-6 permalloy layers of 0.35 mm thickness, is 2.4mx2.4mx2.4m in size, and has a shielding factor of 40 at 1 Hz, $10^4$ at 100 Hz. Our 64-channel second-order gradiometer MCG system consists of 64 2nd-order DROS gradiometers, flux-locked loop electronics, and analog signal processors. With the 2nd-order DROS gradiometers and flux-locked loop electronics installed inside the poorly-shielded MSR, and with the analog signal processor installed outside it, the noise level was measured to be 20 $fT/{\surd}Hz$ at 1 Hz and 8 $fT/{\surd}Hz$ at 200 Hz on the average even though the MSR door is open. This result leads to a low noise level, low enough to obtain a human MCG at the same level as that measured in the heavily-shielded MSR. However, filters or active shielding is needed fur clear MCG when there is large low-frequency noise from heavy air conditioning or large ac power consumption near the poorly-shielded MSR.

  • PDF

A 12b 1kS/s 65uA 0.35um CMOS Algorithmic ADC for Sensor Interface in Ubiquitous Environments (유비쿼터스 환경에서의 센서 인터페이스를 위한 12비트 1kS/s 65uA 0.35um CMOS 알고리즈믹 A/D 변환기)

  • Lee, Myung-Hwan;Kim, Yong-Woo;Lee, Seung-Hoon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.45 no.3
    • /
    • pp.69-76
    • /
    • 2008
  • This work proposes a 12b 1kS/s 65uA 0.35um CMOS algorithmic ADC for sensor interface applications such as accelerometers and gyro sensors requiring high resolution, ultra-low power, and small size simultaneously. The proposed ADC is based on an algorithmic architecture with recycling techniques to optimize sampling rate, resolution, chip area, and power consumption. Two versions of ADCs are fabricated with a conventional open-loop sampling scheme and a closed-loop sampling scheme to investigate the effects of offset and 1/f noise during dynamic operation. Switched bias power-reduction techniques and bias circuit sharing reduce the power consumption of amplifiers in the SHA and MDAC. The current and voltage references are implemented on chip with optional of-chip voltage references for low-power SoC applications. The prototype ADC in a 0.35um 2P4M CMOS technology demonstrates a measured DNL and INL within 0.78LSB and 2.24LSB, and shows a maximum SNDR and SFDR of 60dB and 70dB in versionl, and 63dB and 75dB in version2 at 1kS/s. The versionl and version2 ADCs with an active die area of $0.78mm^2$ and $0.81mm^2$ consume 0.163mW and 0.176mW at 1kS/s and 2.5V, respectively.

Analysis of the Vent Path Through the Pressurizer Manway Under the Loss of Residual Heat Removal(RHR) System During Mid-Loop Operation in PWR (가압경수로 부분충수 운전중 잔열제거 (RHR)계통 상실시 가압기 통로를 통한 배출유로 특성 분석)

  • Ha, G.S.;Kim, W.S.;Chang, W.P.;Yoo, K.J.
    • Nuclear Engineering and Technology
    • /
    • v.27 no.6
    • /
    • pp.859-869
    • /
    • 1995
  • The present study is to understand the physical phenomena anticipated during the accident with RHR loss under mid-loop operation in a PWR and, at the same time, to examine the prediction capability of RELAP5/MOD3.1 on such an accident, by simulating an integral test relevant to this accident for reliable analysis in an actual PWR. The selected experiment, i.g. BETHSY Test 6.9a, represents the configuration with the pressurizer manway open and steam generators unavailable during the accident. Accordingly, the results of this ok are sure to contribute to understanding both the key events as well as the sensitive parameters, anticipated in the accident, for validity of the actual analysis. In the simulation result overall behavior as well as major phenomena observed in the experiment have been predicted reasonably by RELAP5/MOD3.1, however, the problem associated with enormous computing time .due to small time step size has been encountered. Besides, the code prediction of higher swollen level in the pressure vessel has given rise to overestimation of both pressurizer level and RCS pressure. Subsequently, overprediction of the break flow through the manway has led to earlier core uncovery than that in the experiment by about 400 seconds. As a whole, it is demonstrated from both the experiment and the analysis that gravity feed has not been sufficient to recover the core level and thus additional forced feed has been necessary in this configuration.

  • PDF

A Study on An Integrated GEO/TES with Geothermal Heat Exchanger and Thermal Ice Storage (지중열 교환기와 빙축열조(Thermal Ice Storage)를 연계시킨 통합 지중열-빙축열조 시스템(Integrated GEO/TES))

  • Lohrenz ED.;Hahn Jeongsang;Han Hyuk Sang;Hahn Chan;Kim Hyoung Soo
    • Economic and Environmental Geology
    • /
    • v.38 no.6 s.175
    • /
    • pp.717-729
    • /
    • 2005
  • Peak cooling load of large buildings is generally greater than their peak heating load. Internal and solar heat gains are used fur selection of adquate equipment in large building in cold winter climate like Canada and even Korea. The cost of geothermal heat exchanger to meet the cooling loads can increase the initial cost of ground source heat pump system to the extend less costly conventional system often chosen. Thermal ice storage system has been used for many years in Korea to reduce chiller capacity and shift Peak electrical time and demand. A distribution system designed to take advantage of heat extracted from the ice, and use of geothermal loop (geothermal heat exchanger) to heat as an alternate heat source and sink is well known to provide many benifits. The use of thermal energy storage (TES) reduces the heat pump capacity and peak cooling load needed in large building by as much as 40 to $60\%$ with less mechanical equipment and less space for mechanical room. Additionally TES can reduce the size and cost of the geothermal loop by 1/3 to 1/4 compared to ground coupled heat pump system that is designed to meet the peak heating and cooling load and also can eliminate difficuties of geothermal loop installation such as space requirements and thermal conditions of soil and rock at the urban area.

ITS2 DNA Sequence Analysis for Eight Species of Delphacid Planthoppers and a Loop-mediated Isothermal Amplification Method for the Brown Planthopper-specific Detection (멸구과 8종의 ITS2 DNA 염기서열 비교 분석과 고리매개등온증폭법(LAMP)을 이용한 벼멸구 특이 진단법)

  • Seo, Bo Yoon;Park, Chang Gyu;Koh, Young-Ho;Jung, Jin Kyo;Cho, Jumrae;Kang, Chanyeong
    • Korean journal of applied entomology
    • /
    • v.56 no.4
    • /
    • pp.377-385
    • /
    • 2017
  • Estimates of evolutionary sequence divergence and inference of a phylogenetic tree for eight delphacid planthopper species were based on the full-length nucleotide sequence of the internal transcribed spacer 2 (ITS2) region. Size of the ITS2 DNA sequence varied from 550 bp in Sogatella furcifera to 699 bp in Nilaparvata muiri. Nucleotide sequence distance ($d{\pm}S.E.$) was lowest between N. muiri and N. bakeri ($0.001{\pm}0.001$), and highest between Ecdelphax cervina and Stenocranus matsumurai ($0.579{\pm}0.021$). Sequence distance between N. lugens and other planthoppers ranged from $0.056{\pm}0.008$ (N. muiri) to $0.548{\pm}0.021$ (S. matsumurai). In the neighbor-joining phylogenetic tree, all planthoppers were clustered separately into a species group, except N. muiri and N. bakeri. The ITS2 nucleotide sequence of N. lugens was used to design four loop-mediated isothermal amplification (LAMP) primer sets (BPH-38, BPH-38-1, BPH-207, and BPH-92) for N. lugens species-specific detection. After the LAMP reaction of three rice planthoppers, N. lugens, S. furcifera, and Laodelphax striatellus, with the four LAMP primer sets for 60 min at $65^{\circ}C$, LAMP products were observed in the genomic DNA of N. lugens only. In the BPH-92 LAMP primer set, the fluorescence relative to that of the negative control differed according to the amount of DNA (0.1 ng, 10 ng, and 100 ng) and incubation duration (20 min, 30 min, 40 min, and 60 min). At $65^{\circ}C$ incubation, the difference was clearly observed after 40 min with 10 ng and100 ng, but with a 60-min incubation period, the minimum DNA needed was 0.1 ng. However, there was little difference in fluorescence among all DNA amounts tested with 20 or 30 min incubations.

Use of Minimal Spanning Trees on Self-Organizing Maps (자기조직도에서 최소생성나무의 활용)

  • Jang, Yoo-Jin;Huh, Myung-Hoe;Park, Mi-Ra
    • The Korean Journal of Applied Statistics
    • /
    • v.22 no.2
    • /
    • pp.415-424
    • /
    • 2009
  • As one of the unsupervised learning neural network methods, self-organizing maps(SOM) are applied to various fields. It reduces the dimension of multidimensional data by representing observations on the low dimensional manifold. On the other hand, the minimal spanning tree(MST) of a graph that achieves the most economic subset of edges connecting all components by a single open loop. In this study, we apply the MST technique to SOM with subnodes. We propose SOM's with embedded MST and a distance measure for optimum choice of the size and shape of the map. We demonstrate the method with Fisher's Iris data and a real gene expression data. Simulated data sets are also analyzed to check the validity of the proposed method.

Performance Analysis of Dual-Layer Differential Precoding Technique Using 8-PSK Constellation (8-PSK 성운을 이용하는 이중계층 차분 선부호화 기법의 성능 분석)

  • Park, Noe-Yoon;Kim, Young-Ju
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38A no.5
    • /
    • pp.401-408
    • /
    • 2013
  • Dual-layer differential codebook using 8-PSK (phase shift keying) constellation as its codeword elements, is proposed for Long term evolution (LTE) and/or LTE-Advanced systems. Due to the temporal correlation of the adjacent channel matrices, the consecutive precoding matrices are likely to be similar. This approach quantize only the differential information of the channel instead of the whole channel subspace, which virtually increase the codebook size to realize more accurate quantization of the channel. Especially, the proposed codebook has the same properties of LTE release-8 codebook that is, constant modulus, complexity reduction, and nested property. The mobile station can be designed by using less expensive non-linear amplifier utilizing constant modulus property. Computer simulations show that the capacity of the proposed dual-layer codebook performs almost 1.2dB better than those of any other non-differential codebooks with the same amount of feedback information.

Performance Evaluation of Hydrostatic Bearing Guided Rotary Table for Large Volume Multi-tasking Vertical Lathe (대형 복합수직선반 가공기용 유정압베어링 회전테이블 성능 실험 및 분석)

  • Shim, Jongyoup;Oh, Jeong-Seok;Park, Chun-Hong;Shin, Heung-Chul;Park, Woo-Sang;Kim, Min-Jae;Kim, Min-Soo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.31 no.7
    • /
    • pp.635-642
    • /
    • 2014
  • The large volume multi-tasking vertical lathe was developed for machining the bearing parts for a wind power generator. Although the machined part is large in size high precision tolerances are required recently. One of the most important components to achieve this mission is the rotating table which holds and supports the part to be machined. The oil hydrostatic bearing is adopted for the thrust bearing and the rolling bearing for the radial bearing. In this article experimental performance evaluation and its analysis results are presented. The rotational accuracy of the table is assessed and the frequency domain analysis for the structural loop is performed. And in order to evaluate the structural characteristic of table the moment load experiment is performed. The rotational error motion is measured as below 10 ${\mu}m$ for the radial and axial direction and 22,800 Nm/arcsec of moment stiffness is achieved for the rotary table.